Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
To version 38.1
edited by Ben
on 2022/08/24 11:20
on 2022/08/24 11:20
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 10 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.Ben - Content
-
... ... @@ -1,7 +1,5 @@ 1 -= ** 1 General communicationwith PLC** =1 += **Modbus RTU** = 2 2 3 -== **Modbus RTU** == 4 - 5 5 === **V-BOX as master** === 6 6 7 7 Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, ... ... @@ -47,22 +47,256 @@ 47 47 |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 48 48 |0F (Write multiple bits) 49 49 50 -= =**WECONLX3VPLC** ==48 += **WECON PLC** = 51 51 52 - Select the protocol (% class="mark"%)"WECONLX3V"50 +== **V-BOX 和维控 LX3V 串行通信** == 53 53 54 - (% class="mark" %)thenset BaudRate,Port,Stop Bit,DataBit,ParitysamewithPLC.52 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 55 55 56 - (%class="mark" %)WECON PLC RS422 port,defaultcommunicationparametersis 9600,1,7,ZEVEN54 +**HMI Settings** 57 57 56 +|**Item**|**Settings**|**Note** 57 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| 58 +|Connection|RS422/RS485| 59 +|Baud rate|9600| 60 +|Data bit|7| 61 +|Parity|EVEN| 62 +|Stop bit|1| 63 +|PLC station No.|1| 64 + 65 +**Address List** 66 + 67 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 68 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237| 69 +|Y|Y|Y o|0~~303237| 70 +|M|M|M d|0~~99999| 71 +|T|T|T d|0~~99999| 72 +|C|C|C d|0~~99999| 73 +|S|S|S d|0~~99999| 74 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 75 +|Y|Y|Y o|0~~303237| 76 +|M|M|M d|0~~99999| 77 +|T|T|T d|0~~99999| 78 +|C|C|C d|0~~199| 79 +|D|D|D d|0~~7999| 80 +|S|S|S d|0~~99999| 81 +|SD|SD|SD d|8000~~9999| 82 + 83 +**Cable Wiring** 84 + 85 +* **RS485** 86 + 87 + [[image:image-20220822172124-1.png]] 88 + 89 +* **RS422** 90 + 91 + [[image:image-20220822172228-2.png]] 92 + 93 + 94 +**✎Note:** 95 + 96 +* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) . 97 +* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual. 98 + 99 +[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 100 + 101 + 102 +== **V-BOX and Wecon LX5V serial communication** == 103 + 104 +This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 105 + 106 +**Software configuration of PLC** 107 + 108 +**1)PLC programming software** 109 + 110 +[[image:image-20220822172553-1.png]] 111 + 112 +**2)New PLC project** 113 + 114 +Click New Project and select the PLC model. 115 + 116 +[[image:image-20220822172623-2.png]] 117 + 118 +**3)Set Serial port parameters** 119 + 120 +Follow the steps below to configure Serial port parameters 121 + 122 +Baud rate:115200 123 + 124 +Data bit:8 125 + 126 +Stop bit:1 127 + 128 +Parity:No verification 129 + 130 +[[image:image-20220822172657-3.png]] 131 + 132 +**4)Registers list** 133 + 134 +[[image:image-20220822172730-4.png]] 135 + 136 +**V-BOX software configuration** 137 + 138 +**1)V-BOX programming software** 139 + 140 + [[image:image-20220824104124-1.png]] 141 + 142 +**2)V-NET add device** 143 + 144 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device. 145 + 146 +[[image:image-20220824104909-2.png]] 147 + 148 + 149 +**3)Set communication port parameters** 150 + 151 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. 152 + 153 +Baud rate:115200 154 + 155 +Data bit:8 156 + 157 +Stop bit:1 158 + 159 +Parity:No verification 160 + 161 +[[image:image-20220811104012-1.png]] 162 + 163 + 164 +**hardware connection** 165 + 166 +**1)Hardware wiring diagram** 167 + 168 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 169 + 170 + 171 + 172 +[[image:image-20220811103005-4.png]] 173 + 174 +[[image:image-20220811103227-7.png]] 175 + 176 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 177 + 178 +== **V-BOX and Wecon LX5V-N Ethernet communication** == 179 + 180 + This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 181 + 182 +**Software configuration of PLC** 183 + 184 +**1)PLC programming software** 185 + 186 +[[image:image-20220810164710-1.png]] 187 + 188 +**2)New PLC project** 189 + 190 +Click New Project and select the PLC model. 191 + 192 +[[image:image-20220811115454-1.png]] 193 + 194 +**3)Set Ethernet port parameters** 195 + 196 +Follow the steps below to configure Ethernet parameters 197 + 198 +PLC IP address:192.168.39.200 199 + 200 +default gateway:192.168.39.1 201 + 202 +subnet mask:255.255.255.0 203 + 204 +[[image:image-20220811140530-2.png]] 205 + 206 +**4)Registers list** 207 + 208 +[[image:image-20220811102219-3.png]] 209 + 210 +**HMI software configuration** 211 + 212 +**1)HMI programming software** 213 + 214 + [[image:image-20220810171237-4.png]] 215 + 216 +**2)New HMI project** 217 + 218 +Click New Project and select the HMI model. 219 + 220 +[[image:image-20220810172010-5.png]] 221 + 222 +**3)Set communication port parameters** 223 + 224 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 225 + 226 +HMI IP address:192.168.39.201 227 + 228 +default gateway:192.168.39.1 229 + 230 +subnet mask:255.255.255.0 231 + 232 +[[image:image-20220811170753-2.png]] 233 + 234 +Next, click Communication Settings to configure the IP of the HMI communication object. 235 + 236 +[[image:image-20220811163047-1.png]] 237 + 238 +**hardware connection** 239 + 240 +**1)Hardware wiring diagram** 241 + 242 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 243 + 244 +[[image:image-20220811170248-1.png]] 245 + 246 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 247 + 58 58 (% style="text-align:center" %) 59 59 [[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]] 60 60 61 -= =**2 Communicationwith Allen-Bradley CompactLogixL1769** ==251 += **Rockwell PLC** = 62 62 253 + 254 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix** == 255 + 256 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 257 + 258 +**HMI Settings** 259 + 260 +|**Item**|**Settings**|**Note** 261 +|Protocol|Allen-Bradlley MicroLogix| 262 +|Connection|RS232| 263 +|Baud rate|19200| 264 +|Data bit|8| 265 +|Parity|None| 266 +|Stop bit|1| 267 +|PLC station No.|1| 268 + 269 +**Address List** 270 + 271 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 272 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 273 +|O|O d.d|0.0~~255.15| 274 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 275 +|S|S d.d|0.0~~255.15| 276 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 277 +|(% rowspan="9" %)Word|S|S d|0~~255| 278 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 279 +|TP|TP nnhh|0~~ffff 280 +|CS|CS nnhh|0~~ffff 281 +|CP|CP nnhh|0~~ffff 282 +|N|N nnhh|0~~ffff 283 +|C|C nnhh|0~~ffff 284 +|T|T nnhh|0~~ffff 285 +|R|R nnhh|0~~ffff 286 + 287 +**Cable Wiring** 288 + 289 +[[image:image-20220824110724-1.png]] 290 + 291 + 292 + 293 +== **CompactLogix** == 294 + 63 63 ((( 64 64 ((( 65 -This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-BradleyL1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.297 +This example introduces the establishment of Ethernet communication between Wecon V-box and CompactLogix L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring. 66 66 ))) 67 67 68 68 ... ... @@ -199,7 +199,7 @@ 199 199 200 200 ((( 201 201 ((( 202 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]]434 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] 203 203 ))) 204 204 205 205 ... ... @@ -226,7 +226,7 @@ 226 226 227 227 228 228 ((( 229 -After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label. [[image:image-20220714162827-11.png]]461 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]] 230 230 ))) 231 231 232 232 (% class="wikigeneratedid" id="HEngineeringproduction" %) ... ... @@ -261,6 +261,15 @@ 261 261 262 262 ((( 263 263 The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC. 496 + 497 +== == 498 + 499 +== **Allen-Bradley Ethernet DF1** == 500 + 501 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 502 + 503 + 504 += **Siemens PLC** = 264 264 ))) 265 265 ))) 266 266 ... ... @@ -268,14 +268,12 @@ 268 268 269 269 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 270 270 271 -== **Allen-Bradley Ethernet DF1** == 272 - 273 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 274 - 275 275 == **Communication with S7-200 Smart** == 276 276 277 277 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 278 278 516 += **Delta PLC** = 517 + 279 279 == **Delta DVP Ethernet** == 280 280 281 281 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
- image-20220820164423-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.4 KB - Content
- image-20220822172124-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.7 KB - Content
- image-20220822172228-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +48.8 KB - Content
- image-20220822172553-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.9 KB - Content
- image-20220822172623-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +111.2 KB - Content
- image-20220822172657-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +141.6 KB - Content
- image-20220822172730-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +130.7 KB - Content
- image-20220824104124-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.6 KB - Content
- image-20220824104909-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +278.8 KB - Content
- image-20220824110724-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +79.1 KB - Content