Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 19.1
edited by Stone Wu
on 2022/08/01 10:01
Change comment: Renamed back-links.
To version 67.1
edited by Ben
on 2022/08/24 12:00
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.Ben
Content
... ... @@ -1,71 +1,240 @@
1 -= **1 General communication with PLC** =
1 += (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) =
2 2  
3 -== **Modbus RTU** ==
3 +== **LX3V Serial Protocol** ==
4 4  
5 -=== **V-BOX as master** ===
5 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
7 -Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
7 +**HMI Settings**
8 8  
9 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
9 +|**Item**|**Settings**|**Note**
10 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
11 +|Connection|RS422/RS485|
12 +|Baud rate|9600|
13 +|Data bit|7|
14 +|Parity|EVEN|
15 +|Stop bit|1|
16 +|PLC station No.|1|
10 10  
11 -(% style="text-align:center" %)
12 -[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
18 +**Address List**
13 13  
14 -=== **V-BOX as slave** ===
20 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
21 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
22 +|Y|Y|Y o|0~~303237|
23 +|M|M|M d|0~~99999|
24 +|T|T|T d|0~~99999|
25 +|C|C|C d|0~~99999|
26 +|S|S|S d|0~~99999|
27 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
28 +|Y|Y|Y o|0~~303237|
29 +|M|M|M d|0~~99999|
30 +|T|T|T d|0~~99999|
31 +|C|C|C d|0~~199|
32 +|D|D|D d|0~~7999|
33 +|S|S|S d|0~~99999|
34 +|SD|SD|SD d|8000~~9999|
15 15  
16 -Select the protocol “(% class="mark" %)**Modbus RTU Master**,
36 +**Cable Wiring**
17 17  
18 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
38 +* **RS422**
19 19  
20 -(% style="text-align:center" %)
21 -[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]]
40 + [[image:image-20220822172228-2.png]]
22 22  
23 -**Address List**
42 +== **LX5V Serial Protocol** ==
24 24  
25 -(% class="table-bordered" %)
26 -|**Type**|**Register**|**Function code & Description**
27 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
28 -|06 (write single register: write a binary value to a holding register)
29 -|10 (write values to multiple addresses )
30 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
31 -|06 (write single register: write a binary value to a holding register)
32 -|10 (write values to multiple addresses )
33 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
34 -|06 (write single register: write a binary value to a holding register)
35 -|10 (write values to multiple addresses )
36 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
37 -|10 (write values to multiple addresses )
38 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
39 -|05 (Force a single coil to force the on/off state of a logic coil)
40 -|0F (Write multiple bits, ie write continuously)
41 -|(% rowspan="3" %)1|02 (Read the input state)
42 -|05 (Force a single coil to force the on/off state of a logic coil)
43 -|0F (Write multiple bits)
44 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
45 -|05 (Force a single coil to force the on/off state of a logic coil)
46 -|0F (Write multiple bits)
47 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
48 -|0F (Write multiple bits)
44 +This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
49 49  
50 -== **WECON LX3V PLC** ==
46 +**Software configuration of PLC**
51 51  
52 -Select the protocol (% class="mark" %)"WECON LX3V"
48 +**1)PLC programming software**
53 53  
54 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity same with PLC.
50 +[[image:image-20220822172553-1.png]]
55 55  
56 -(% class="mark" %)WECON PLC RS422 port,default communication parameters is 9600,1,7,ZEVEN
52 +**2)New PLC project**
57 57  
54 +Click New Project and select the PLC model.
55 +
56 +[[image:image-20220822172623-2.png]]
57 +
58 +**3)Set Serial port parameters**
59 +
60 +Follow the steps below to configure Serial port parameters
61 +
62 +Baud rate:115200
63 +
64 +Data bit:8
65 +
66 +Stop bit:1
67 +
68 +Parity:No verification
69 +
70 +[[image:image-20220822172657-3.png]]
71 +
72 +**4)Registers list**
73 +
74 +[[image:image-20220822172730-4.png]]
75 +
76 +**V-BOX software configuration**
77 +
78 +**1)V-BOX programming software**
79 +
80 + [[image:image-20220824104124-1.png]]
81 +
82 +**2)V-NET add device**
83 +
84 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device.
85 +
86 +[[image:image-20220824104909-2.png]]
87 +
88 +
89 +**3)Set communication port parameters**
90 +
91 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
92 +
93 +Baud rate:115200
94 +
95 +Data bit:8
96 +
97 +Stop bit:1
98 +
99 +Parity:No verification
100 +
101 +[[image:image-20220811104012-1.png]]
102 +
103 +
104 +**hardware connection**
105 +
106 +**1)Hardware wiring diagram**
107 +
108 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
109 +
110 +
111 +
112 +[[image:image-20220811103005-4.png]]
113 +
114 +[[image:image-20220811103227-7.png]]
115 +
116 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
117 +
118 +== **LX5V-N Ethernet protocol** ==
119 +
120 + This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
121 +
122 +**Software configuration of PLC**
123 +
124 +**1)PLC programming software**
125 +
126 +[[image:image-20220810164710-1.png]]
127 +
128 +**2)New PLC project**
129 +
130 +Click New Project and select the PLC model.
131 +
132 +[[image:image-20220811115454-1.png]]
133 +
134 +**3)Set Ethernet port parameters**
135 +
136 +Follow the steps below to configure Ethernet parameters
137 +
138 +PLC IP address:192.168.39.200
139 +
140 +default gateway:192.168.39.1
141 +
142 +subnet mask:255.255.255.0
143 +
144 +[[image:image-20220811140530-2.png]]
145 +
146 +**4)Registers list**
147 +
148 +[[image:image-20220811102219-3.png]]
149 +
150 +**HMI software configuration**
151 +
152 +**1)HMI programming software**
153 +
154 + [[image:image-20220810171237-4.png]]
155 +
156 +**2)New HMI project**
157 +
158 +Click New Project and select the HMI model.
159 +
160 +[[image:image-20220810172010-5.png]]
161 +
162 +**3)Set communication port parameters**
163 +
164 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
165 +
166 +HMI IP address:192.168.39.201
167 +
168 +default gateway:192.168.39.1
169 +
170 +subnet mask:255.255.255.0
171 +
172 +[[image:image-20220811170753-2.png]]
173 +
174 +Next, click Communication Settings to configure the IP of the HMI communication object.
175 +
176 +[[image:image-20220811163047-1.png]]
177 +
178 +**hardware connection**
179 +
180 +**1)Hardware wiring diagram**
181 +
182 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
183 +
184 +[[image:image-20220811170248-1.png]]
185 +
186 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
187 +
58 58  (% style="text-align:center" %)
59 59  [[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
60 60  
61 -== **2 Communication with Allen-Bradley CompactLogix L1769** ==
191 += **Rockwell PLC** =
62 62  
193 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
194 +
195 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
196 +
197 +**HMI Settings**
198 +
199 +|**Item**|**Settings**|**Note**
200 +|Protocol|Allen-Bradlley MicroLogix|
201 +|Connection|RS232|
202 +|Baud rate|19200|
203 +|Data bit|8|
204 +|Parity|None|
205 +|Stop bit|1|
206 +|PLC station No.|1|
207 +
208 +**Address List**
209 +
210 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
211 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
212 +|O|O d.d|0.0~~255.15|
213 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
214 +|S|S d.d|0.0~~255.15|
215 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
216 +|(% rowspan="9" %)Word|S|S d|0~~255|
217 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
218 +|TP|TP nnhh|0~~ffff
219 +|CS|CS nnhh|0~~ffff
220 +|CP|CP nnhh|0~~ffff
221 +|N|N nnhh|0~~ffff
222 +|C|C nnhh|0~~ffff
223 +|T|T nnhh|0~~ffff
224 +|R|R nnhh|0~~ffff
225 +
226 +**Cable Wiring**
227 +
228 +[[image:image-20220824110724-1.png]]
229 +
230 +
231 +
232 +== **CompactLogix Protocol** ==
233 +
63 63  (((
64 64  (((
65 -This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
236 +This example introduces the establishment of Ethernet communication between Wecon V-box and CompactLogix L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
66 66  )))
67 -
68 -
69 69  )))
70 70  
71 71  (((
... ... @@ -199,7 +199,7 @@
199 199  
200 200  (((
201 201  (((
202 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   ​​​​​​​[[image:image-20220714162752-8.png]]
371 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
203 203  )))
204 204  
205 205  
... ... @@ -226,7 +226,7 @@
226 226  
227 227  
228 228  (((
229 -After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.​​​​​​​[[image:image-20220714162827-11.png]]
398 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]]
230 230  )))
231 231  
232 232  (% class="wikigeneratedid" id="HEngineeringproduction" %)
... ... @@ -260,48 +260,105 @@
260 260  [[image:image-20220714162856-13.png]]
261 261  
262 262  (((
263 -The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC.
432 +The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
433 +
434 +
435 +== **Allen-Bradley Ethernet DF1** ==
436 +
437 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
438 +
439 +
440 += **Siemens PLC** =
441 +
442 +== **S7-200 Smart Ethernet Protocol** ==
443 +
444 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
264 264  )))
265 265  )))
266 266  
267 -== **Siemens S7-1200** ==
448 +== **S7-1200 Ethernet Protocol** ==
268 268  
269 269  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
270 270  
271 -== **Allen-Bradley Ethernet DF1** ==
452 += **Mitsubishi PLC** =
272 272  
273 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
454 +== **Mitsubishi FX Series Protocol** ==
274 274  
275 -== **Communication with S7-200 Smart** ==
456 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
276 276  
277 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
458 += **Delta PLC** =
278 278  
279 -== **Delta DVP Ethernet** ==
460 +== **DVP Ethernet Protocol** ==
280 280  
281 281  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
282 282  
283 -== **Delta DVP Serial Protocol** ==
464 +== **DVP Serial Protocol** ==
284 284  
285 285  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
286 286  
287 -== **Communicate with Mitsubishi FX Series** ==
468 += **Omron PLC** =
288 288  
289 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
470 +== **CP1 Series Protocol** ==
290 290  
291 -== **Communicate with VB inverter** ==
472 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
292 292  
293 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
474 +== **CJ2M Series Protocol** ==
294 294  
295 -== **Omron CP1 Series** ==
476 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
296 296  
297 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
478 += **Modbus RTU** =
298 298  
299 -== **Omron CJ2M** ==
480 +== **V-BOX as master** ==
300 300  
301 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
482 +Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
302 302  
303 -= **2 User define protocol** =
484 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
304 304  
486 +(% style="text-align:center" %)
487 +[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
488 +
489 +== **V-BOX as slave** ==
490 +
491 +Select the protocol “(% class="mark" %)**Modbus RTU Master”**,
492 +
493 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
494 +
495 +(% style="text-align:center" %)
496 +[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]]
497 +
498 +**Address List**
499 +
500 +(% class="table-bordered" %)
501 +|**Type**|**Register**|**Function code & Description**
502 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
503 +|06 (write single register: write a binary value to a holding register)
504 +|10 (write values to multiple addresses )
505 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
506 +|06 (write single register: write a binary value to a holding register)
507 +|10 (write values to multiple addresses )
508 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
509 +|06 (write single register: write a binary value to a holding register)
510 +|10 (write values to multiple addresses )
511 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
512 +|10 (write values to multiple addresses )
513 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
514 +|05 (Force a single coil to force the on/off state of a logic coil)
515 +|0F (Write multiple bits, ie write continuously)
516 +|(% rowspan="3" %)1|02 (Read the input state)
517 +|05 (Force a single coil to force the on/off state of a logic coil)
518 +|0F (Write multiple bits)
519 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
520 +|05 (Force a single coil to force the on/off state of a logic coil)
521 +|0F (Write multiple bits)
522 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
523 +|0F (Write multiple bits)
524 +
525 +== **communicate with VB inverter** ==
526 +
527 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
528 +
529 += **User define protocol** =
530 +
305 305  More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
306 306  
307 307  == **Read the temperature sensor.** ==
image-20220820164423-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +18.4 KB
Content
image-20220822172124-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +38.7 KB
Content
image-20220822172228-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +48.8 KB
Content
image-20220822172553-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +19.9 KB
Content
image-20220822172623-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +111.2 KB
Content
image-20220822172657-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +141.6 KB
Content
image-20220822172730-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +130.7 KB
Content
image-20220824104124-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +14.6 KB
Content
image-20220824104909-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +278.8 KB
Content
image-20220824110724-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +79.1 KB
Content