Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
To version 70.1
edited by Ben
on 2022/08/24 14:26
on 2022/08/24 14:26
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 18 added, 0 removed)
- image-20220820164423-1.png
- image-20220822172124-1.png
- image-20220822172228-2.png
- image-20220822172553-1.png
- image-20220822172623-2.png
- image-20220822172657-3.png
- image-20220822172730-4.png
- image-20220824104124-1.png
- image-20220824104909-2.png
- image-20220824110724-1.png
- image-20220824120406-1.png
- image-20220824120507-2.png
- image-20220824120524-3.png
- image-20220824120547-4.png
- image-20220824120614-5.png
- image-20220824142130-1.png
- image-20220824142546-2.png
- image-20220824142643-3.png
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.Ben - Content
-
... ... @@ -1,71 +1,243 @@ 1 -= **1GeneralcommunicationwithPLC** =1 += (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) = 2 2 3 -== ** ModbusRTU** ==3 +== **LX3V Serial Protocol** == 4 4 5 - ===**V-BOX asmaster**===5 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 7 - Select the protocol “(% class="mark" %)ModbusRTUSlave(All Fuction)”,7 +**HMI Settings** 8 8 9 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 9 +|**Item**|**Settings**|**Note** 10 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| 11 +|Connection|RS422/RS485| 12 +|Baud rate|9600| 13 +|Data bit|7| 14 +|Parity|EVEN| 15 +|Stop bit|1| 16 +|PLC station No.|1| 10 10 11 -(% style="text-align:center" %) 12 -[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 18 +**Address List** 13 13 14 -=== **V-BOX as slave** === 20 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 21 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237| 22 +|Y|Y|Y o|0~~303237| 23 +|M|M|M d|0~~99999| 24 +|T|T|T d|0~~99999| 25 +|C|C|C d|0~~99999| 26 +|S|S|S d|0~~99999| 27 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 28 +|Y|Y|Y o|0~~303237| 29 +|M|M|M d|0~~99999| 30 +|T|T|T d|0~~99999| 31 +|C|C|C d|0~~199| 32 +|D|D|D d|0~~7999| 33 +|S|S|S d|0~~99999| 34 +|SD|SD|SD d|8000~~9999| 15 15 16 - Select the protocol “(% class="mark" %)**Modbus RTU Master”**,36 +**Cable Wiring** 17 17 18 - (%class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity38 +* **RS422** 19 19 20 -(% style="text-align:center" %) 21 -[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 40 + [[image:image-20220824120614-5.png]] 22 22 23 -* *AddressList**42 +* **RS485** 24 24 25 -(% class="table-bordered" %) 26 -|**Type**|**Register**|**Function code & Description** 27 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 28 -|06 (write single register: write a binary value to a holding register) 29 -|10 (write values to multiple addresses ) 30 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 31 -|06 (write single register: write a binary value to a holding register) 32 -|10 (write values to multiple addresses ) 33 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 34 -|06 (write single register: write a binary value to a holding register) 35 -|10 (write values to multiple addresses ) 36 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 37 -|10 (write values to multiple addresses ) 38 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 39 -|05 (Force a single coil to force the on/off state of a logic coil) 40 -|0F (Write multiple bits, ie write continuously) 41 -|(% rowspan="3" %)1|02 (Read the input state) 42 -|05 (Force a single coil to force the on/off state of a logic coil) 43 -|0F (Write multiple bits) 44 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 45 -|05 (Force a single coil to force the on/off state of a logic coil) 46 -|0F (Write multiple bits) 47 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 48 -|0F (Write multiple bits) 44 + [[image:image-20220824120524-3.png]] 49 49 50 -== ** WECONLX3V PLC** ==46 +== **LX5V Serial Protocol** == 51 51 52 - Select the protocol(%class="mark"%)"WECONLX3V"48 +This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 53 53 54 - (% class="mark" %)thenset BaudRate,Port,Stop Bit,Data Bit,ParitysamewithPLC.50 +**Software configuration of PLC** 55 55 56 - (% class="mark" %)WECONPLCRS422port,default communicationparameters is 9600,1,7,ZEVEN52 +**1)PLC programming software** 57 57 54 +[[image:image-20220822172553-1.png]] 55 + 56 +**2)New PLC project** 57 + 58 +Click New Project and select the PLC model. 59 + 60 +[[image:image-20220822172623-2.png]] 61 + 62 +**3)Set Serial port parameters** 63 + 64 +Follow the steps below to configure Serial port parameters 65 + 66 +Baud rate:115200 67 + 68 +Data bit:8 69 + 70 +Stop bit:1 71 + 72 +Parity:No verification 73 + 74 +[[image:image-20220822172657-3.png]] 75 + 76 +**4)Registers list** 77 + 78 +[[image:image-20220822172730-4.png]] 79 + 80 +**V-BOX software configuration** 81 + 82 +**1)V-BOX programming software** 83 + 84 + [[image:image-20220824104124-1.png]] 85 + 86 +**2)V-NET add device** 87 + 88 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device. 89 + 90 +[[image:image-20220824104909-2.png]] 91 + 92 + 93 +**3)Set communication port parameters** 94 + 95 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. 96 + 97 +Baud rate:115200 98 + 99 +Data bit:8 100 + 101 +Stop bit:1 102 + 103 +Parity:No verification 104 + 105 +[[image:image-20220824142130-1.png]] 106 + 107 +**hardware connection** 108 + 109 +**1)Hardware wiring diagram** 110 + 111 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 112 + 113 +[[image:image-20220824142546-2.png]] 114 + 115 +[[image:image-20220824142643-3.png]] 116 + 117 + 118 + 119 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 120 + 121 +== **LX5V-N Ethernet protocol** == 122 + 123 + This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 124 + 125 +**Software configuration of PLC** 126 + 127 +**1)PLC programming software** 128 + 129 +[[image:image-20220810164710-1.png]] 130 + 131 +**2)New PLC project** 132 + 133 +Click New Project and select the PLC model. 134 + 135 +[[image:image-20220811115454-1.png]] 136 + 137 +**3)Set Ethernet port parameters** 138 + 139 +Follow the steps below to configure Ethernet parameters 140 + 141 +PLC IP address:192.168.39.200 142 + 143 +default gateway:192.168.39.1 144 + 145 +subnet mask:255.255.255.0 146 + 147 +[[image:image-20220811140530-2.png]] 148 + 149 +**4)Registers list** 150 + 151 +[[image:image-20220811102219-3.png]] 152 + 153 +**HMI software configuration** 154 + 155 +**1)HMI programming software** 156 + 157 + [[image:image-20220810171237-4.png]] 158 + 159 +**2)New HMI project** 160 + 161 +Click New Project and select the HMI model. 162 + 163 +[[image:image-20220810172010-5.png]] 164 + 165 +**3)Set communication port parameters** 166 + 167 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 168 + 169 +HMI IP address:192.168.39.201 170 + 171 +default gateway:192.168.39.1 172 + 173 +subnet mask:255.255.255.0 174 + 175 +[[image:image-20220811170753-2.png]] 176 + 177 +Next, click Communication Settings to configure the IP of the HMI communication object. 178 + 179 +[[image:image-20220811163047-1.png]] 180 + 181 +**hardware connection** 182 + 183 +**1)Hardware wiring diagram** 184 + 185 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 186 + 187 +[[image:image-20220811170248-1.png]] 188 + 189 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 190 + 58 58 (% style="text-align:center" %) 59 59 [[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]] 60 60 61 -= =**2 Communicationwith Allen-Bradley CompactLogixL1769** ==194 += **Rockwell PLC** = 62 62 196 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 197 + 198 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 199 + 200 +**HMI Settings** 201 + 202 +|**Item**|**Settings**|**Note** 203 +|Protocol|Allen-Bradlley MicroLogix| 204 +|Connection|RS232| 205 +|Baud rate|19200| 206 +|Data bit|8| 207 +|Parity|None| 208 +|Stop bit|1| 209 +|PLC station No.|1| 210 + 211 +**Address List** 212 + 213 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 214 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 215 +|O|O d.d|0.0~~255.15| 216 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 217 +|S|S d.d|0.0~~255.15| 218 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 219 +|(% rowspan="9" %)Word|S|S d|0~~255| 220 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 221 +|TP|TP nnhh|0~~ffff 222 +|CS|CS nnhh|0~~ffff 223 +|CP|CP nnhh|0~~ffff 224 +|N|N nnhh|0~~ffff 225 +|C|C nnhh|0~~ffff 226 +|T|T nnhh|0~~ffff 227 +|R|R nnhh|0~~ffff 228 + 229 +**Cable Wiring** 230 + 231 +[[image:image-20220824110724-1.png]] 232 + 233 + 234 + 235 +== **CompactLogix Protocol** == 236 + 63 63 ((( 64 64 ((( 65 -This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-BradleyL1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.239 +This example introduces the establishment of Ethernet communication between Wecon V-box and CompactLogix L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring. 66 66 ))) 67 - 68 - 69 69 ))) 70 70 71 71 ((( ... ... @@ -199,7 +199,7 @@ 199 199 200 200 ((( 201 201 ((( 202 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]]374 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] 203 203 ))) 204 204 205 205 ... ... @@ -226,7 +226,7 @@ 226 226 227 227 228 228 ((( 229 -After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label. [[image:image-20220714162827-11.png]]401 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]] 230 230 ))) 231 231 232 232 (% class="wikigeneratedid" id="HEngineeringproduction" %) ... ... @@ -260,48 +260,105 @@ 260 260 [[image:image-20220714162856-13.png]] 261 261 262 262 ((( 263 -The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC. 435 +The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. 436 + 437 + 438 +== **Allen-Bradley Ethernet DF1** == 439 + 440 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 441 + 442 + 443 += **Siemens PLC** = 444 + 445 +== **S7-200 Smart Ethernet Protocol** == 446 + 447 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 264 264 ))) 265 265 ))) 266 266 267 -== **S iemens S7-1200** ==451 +== **S7-1200 Ethernet Protocol** == 268 268 269 269 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 270 270 271 -= =**Allen-Bradley EthernetDF1** ==455 += **Mitsubishi PLC** = 272 272 273 - [[downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]457 +== **Mitsubishi FX Series Protocol** == 274 274 275 - ==**CommunicationwithS7-200mart** ==459 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]] 276 276 277 - [[downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]461 += **Delta PLC** = 278 278 279 -== **D elta DVP Ethernet** ==463 +== **DVP Ethernet Protocol** == 280 280 281 281 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 282 282 283 -== **D elta DVP Serial Protocol** ==467 +== **DVP Serial Protocol** == 284 284 285 285 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 286 286 287 -= =**Communicatewith Mitsubishi FX Series** ==471 += **Omron PLC** = 288 288 289 - [[downloadlink>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]473 +== **CP1 Series Protocol** == 290 290 291 - ==**CommunicatewithVB inverter** ==475 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 292 292 293 - [[downloadlink>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]477 +== **CJ2M Series Protocol** == 294 294 295 - ==**OmronP1 Series** ==479 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 296 296 297 - [[downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]481 += **Modbus RTU** = 298 298 299 -== **Omr on CJ2M** ==483 +== **V-BOX as master** == 300 300 301 - [[downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]485 +Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, 302 302 303 - =**2 Userdefineprotocol**=487 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 304 304 489 +(% style="text-align:center" %) 490 +[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 491 + 492 +== **V-BOX as slave** == 493 + 494 +Select the protocol “(% class="mark" %)**Modbus RTU Master”**, 495 + 496 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 497 + 498 +(% style="text-align:center" %) 499 +[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 500 + 501 +**Address List** 502 + 503 +(% class="table-bordered" %) 504 +|**Type**|**Register**|**Function code & Description** 505 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 506 +|06 (write single register: write a binary value to a holding register) 507 +|10 (write values to multiple addresses ) 508 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 509 +|06 (write single register: write a binary value to a holding register) 510 +|10 (write values to multiple addresses ) 511 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 512 +|06 (write single register: write a binary value to a holding register) 513 +|10 (write values to multiple addresses ) 514 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 515 +|10 (write values to multiple addresses ) 516 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 517 +|05 (Force a single coil to force the on/off state of a logic coil) 518 +|0F (Write multiple bits, ie write continuously) 519 +|(% rowspan="3" %)1|02 (Read the input state) 520 +|05 (Force a single coil to force the on/off state of a logic coil) 521 +|0F (Write multiple bits) 522 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 523 +|05 (Force a single coil to force the on/off state of a logic coil) 524 +|0F (Write multiple bits) 525 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 526 +|0F (Write multiple bits) 527 + 528 +== **communicate with VB inverter** == 529 + 530 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]] 531 + 532 += **User define protocol** = 533 + 305 305 More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]] 306 306 307 307 == **Read the temperature sensor.** ==
- image-20220820164423-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.4 KB - Content
- image-20220822172124-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.7 KB - Content
- image-20220822172228-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +48.8 KB - Content
- image-20220822172553-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.9 KB - Content
- image-20220822172623-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +111.2 KB - Content
- image-20220822172657-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +141.6 KB - Content
- image-20220822172730-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +130.7 KB - Content
- image-20220824104124-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.6 KB - Content
- image-20220824104909-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +278.8 KB - Content
- image-20220824110724-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +79.1 KB - Content
- image-20220824120406-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.9 KB - Content
- image-20220824120507-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.3 KB - Content
- image-20220824120524-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- image-20220824120547-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +49.2 KB - Content
- image-20220824120614-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +30.9 KB - Content
- image-20220824142130-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +122.2 KB - Content
- image-20220824142546-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +111.2 KB - Content
- image-20220824142643-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.3 KB - Content