Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 13 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bob1 +XWiki.Hunter - Content
-
... ... @@ -176,16 +176,118 @@ 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 178 178 179 -= Create communication with **Rockwell PLC** = 180 180 181 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 182 182 181 += Create communication with Allen-Bradley(**Rockwell**)** PLC** = 182 + 183 +== **DF1 Advanced Protocol** == 184 + 185 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 186 + 187 +**1) V-Box Settings** 188 + 189 +|=Item|=Recommended |=Note 190 +|=Protocol|Allen Bradley DF1 Advanced| 191 +|=Connection|RS232| 192 +|=Baud rate|19200| 193 +|=Stop bits|1| 194 +|=Data bits|8| 195 +|=Parity|None| 196 +|=PLC Station No.|1| 197 +|=HMI Station No.|0| 198 + 199 +**2) Address List** 200 + 201 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note 202 +|(% colspan="1" rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1 203 +|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0 204 +|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2 205 +|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3 206 +|BN|BNddddd.dd|0.0~~99255.15|((( 207 +Bit data file B0~~B99 208 + 209 +First two digits is for file number 210 + 211 +For example, BN13001.00 represents file number B13, address 001, the 0th bit. 212 +))) 213 +|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7 214 +|NN|NNddddd.dd|0.0~~99255.15|((( 215 +Integer data file bit format N0~~N99 216 + 217 +First two digits is for file number 218 + 219 +For example, NN13001.00 represents file number N13, address 001, the 0th bit. 220 +))) 221 +|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2 222 +|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value) 223 +|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value) 224 +|TNS|TNSddddd|0~~99255|((( 225 +Timer Preset Value 226 + 227 +First two digits is for file number 228 + 229 +For example, TNS99255 represents file number T99, address 255. 230 +))) 231 +|TNP|TNPddddd|0~~99255|((( 232 +Timer Accumulator Value 233 + 234 +First two digits is for file number 235 + 236 +For example, TNP99255 represents file number T99, address 255. 237 +))) 238 +|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value) 239 +|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value) 240 +|CNS|CNSddddd|0~~99255|((( 241 +Counter Preset Value 242 + 243 +First two digits is for file number 244 + 245 +For example, CNS99255 represents file number C99, address 255. 246 +))) 247 +|CNP|CNPddddd|0~~99255|((( 248 +Counter Accumulator Value 249 + 250 +First two digits is for file number 251 + 252 +For example, CNP99255 represents file number C99, address 255. 253 +))) 254 +|N7|N7ddd|0~~255|Only able to communicate with file number N7 255 +|NN|NNddd|0~~99255|((( 256 +Integer data file 257 + 258 +First two digits is for file number 259 + 260 +For example, NN99255 represents file number N99, address 255. 261 +))) 262 +|(% colspan="1" rowspan="3" %)Double Word|F8|F8ddd|0~~255|((( 263 +Only able to communicate with file number N7 264 +))) 265 +|FN|FNddddd|0~~99255|((( 266 +Floating point data file 267 + 268 +First two digits is for file number 269 + 270 +For example, FN99255 represents file number F99, address 255. 271 +))) 272 +|LN|LNddddd|0~~99255|Long 273 + 274 +**3) Cable Wiring** 275 + 276 +(% style="text-align:center" %) 277 +[[image:ABRS232.gif]] 278 + 279 +(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %) 280 +(% id="cke_bm_5621S" style="display:none" %)** ** 281 + 282 +== **MicroLogix Protocol** == 283 + 284 +(% class="wikigeneratedid" %) 183 183 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 184 184 185 185 **1)V-BOX setting** 186 186 187 187 |**Item**|**Settings**|**Note** 188 -|Protocol|Allen-Bradl ley DF1 Advanced|290 +|Protocol|Allen-Bradley DF1 Advanced| 189 189 |Connection|RS232| 190 190 |Baud rate|19200| 191 191 |Data bit|8| ... ... @@ -424,7 +424,11 @@ 424 424 425 425 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 426 426 529 += Create communication with **Crouzet PLC** = 427 427 531 +== **CROUZET M3 (FBD)** == 532 + 533 + 428 428 = Create communication with **Siemens PLC** = 429 429 430 430 == **S7-200 Smart Ethernet Protocol** == ... ... @@ -608,6 +608,97 @@ 608 608 609 609 [[image:image-20220824162342-2.png]] 610 610 717 +== **LOGO Ethernet Protocol** == 718 + 719 +Supported Series: Siemens Logo 0BA0, 0BA1 series 720 + 721 +**V-BOX Settings** 722 + 723 + 724 +|**Items**|**Settings**|**Note** 725 +|Protocol|Siemens LOGO| 726 +|Connection|Ethernet| 727 +|Port No.|102| 728 +|PLC station No.|2| 729 + 730 +**Address List** 731 + 732 + 733 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address** 734 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0 735 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000 736 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000 737 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000 738 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0 739 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770 740 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0 741 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180 742 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040 743 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000 744 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140 745 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280 746 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0 747 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70 748 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000 749 + 750 +**PLC Settings in LOGO Software:** 751 + 752 +Click [Tools]~-~-[Ethernet Connections],shown as below. 753 + 754 +(% style="text-align:center" %) 755 +[[image:PIStudio.12\.PLC protocols.WebHome@12.PLC Protocol_html_8b9d2322edf89519.png]] 756 + 757 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 758 + 759 +(% style="text-align:center" %) 760 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228142937-4.png]] 761 + 762 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 763 + 764 +(% style="text-align:center" %) 765 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143047-5.png]] 766 + 767 + **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 768 + 769 +(% style="text-align:center" %) 770 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143246-6.png]] 771 + 772 +**V-BOX Communication Settings** 773 + 774 +Set PLC IP in [IP Address] settings; 775 + 776 +(% style="text-align:center" %) 777 +[[image:LldwDGntf4.png]] 778 + 779 +Enable V-BOX Ethernet in [Network]; 780 + 781 +(% style="text-align:center" %) 782 +[[image:WgvjfWbQif.png]] 783 + 784 +TSAP setting 785 + 786 +* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful. 787 + 788 +{{code language="LUA"}} 789 +function init.main() 790 +addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address 791 +addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address 792 +end 793 +{{/code}} 794 + 795 +Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 796 + 797 +**✎Note:** 798 + 799 +* **Communication port configuration: ** 800 +** Continuous length needs to be set to 0. 801 +** Integration interval needs to be set to 1. (no change may result in data errors) 802 +** Set Port and Device Station NO. 803 +** Other set as defaulted. 804 +* **Notes on the use of registers:** 805 +** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc. 806 +** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 ) 807 + 611 611 = Create communication with **Mitsubishi PLC** = 612 612 613 613 == **FX1S,1N,2N Serial Protocol** == ... ... @@ -1175,12 +1175,105 @@ 1175 1175 1176 1176 == **DVP Ethernet Protocol** == 1177 1177 1178 - [[Downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]1375 +Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module 1179 1179 1377 +**1)V-BOX Settings** 1378 + 1379 +|=**Items**|=**Settings**|=**Note** 1380 +|Protocol|DELTA DVP MODBUS TCP| 1381 +|Connection|Ethernet| 1382 +|Port No.|502| 1383 +|Device No.|1| 1384 +|VBox Device No.|0| 1385 + 1386 +**2)Address List ** 1387 + 1388 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note** 1389 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOO|(% style="width:225px" %)0~~377| 1390 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOO|(% style="width:225px" %)0~~377| 1391 +|Bit|(% style="width:191px" %)M0|(% style="width:217px" %)M0|(% style="width:168px" %)M0DDDD|(% style="width:225px" %)0~~1535| 1392 +|Bit|(% style="width:191px" %)M1|(% style="width:217px" %)M1|(% style="width:168px" %)M1DDDD|(% style="width:225px" %)1536~~4096| 1393 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255| 1394 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~255| 1395 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDD|(% style="width:225px" %)0~~1023| 1396 +|Word|(% style="width:191px" %)D0|(% style="width:217px" %)D0|(% style="width:168px" %)D0DDDD|(% style="width:225px" %)0~~4095| 1397 +|Word|(% style="width:191px" %)D1|(% style="width:217px" %)D1|(% style="width:168px" %)D1DDDD|(% style="width:225px" %)4096~~11999| 1398 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255| 1399 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199| 1400 +|Double Word|(% style="width:191px" %)HC|(% style="width:217px" %)HC|(% style="width:168px" %)HCDDD|(% style="width:225px" %)200~~255| 1401 + 1402 +**3) PLC Setting:** 1403 + 1404 +~1. Create new project in Delta WPL Soft, and click Setting to open the communication settings: 1405 + 1406 +(% style="text-align:center" %) 1407 +[[image:DVPEthernetWPLSoft2.png]] 1408 + 1409 +2. Set up the communication type and PLC IP: 1410 + 1411 +(% style="text-align:center" %) 1412 +[[image:DVPEthernetSetup.png]] 1413 + 1414 +(% class="wikigeneratedid" %) 1415 +3. Click OK and save the settings. Then click Communication on toolbar, then click Transfer Setup to open new window: 1416 + 1417 +(% style="text-align:center" %) 1418 +[[image:DVPEthernetTransfer.png]] 1419 + 1420 +(% class="wikigeneratedid" %) 1421 +4. Select Communication Mode as PC => PLC to download or select PC <=PLC to upload: 1422 + 1423 +(% style="text-align:center" %) 1424 +[[image:DVPEthernetPLCtoPC.png]] 1425 + 1426 +5. Click Auto-Search Ethernet Module to find the PLC on the same LAN network: 1427 + 1428 +(% style="text-align:center" %) 1429 +[[image:DVPEthernetAutoSearch.png]] 1430 + 1431 +**4) V-BOX Setting:** 1432 + 1433 +Set the same IP address according to the setting from WPL Soft: 1434 + 1435 +(% style="text-align:center" %) 1436 +[[image:DVPEthernetVNETPortocol.png]] 1437 + 1180 1180 == **DVP serial protocol** == 1181 1181 1182 - [[Downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]1440 +Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX 1183 1183 1442 +**1)V-BOX Settings** 1443 + 1444 +|=**Items**|=**Settings**|=**Note** 1445 +|Protocol|DELTA DVP PROTOCOL| 1446 +|Connection|RS232| 1447 +|Baud Rate|9600| 1448 +|Stop Bit|1| 1449 +|Data Bit|7| 1450 +|Parity|EVEN| 1451 +|Device No.|1| 1452 + 1453 +(% class="wikigeneratedid" %) 1454 +**2)Address List** 1455 + 1456 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note** 1457 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOOOOO|(% style="width:225px" %)0~~303237| 1458 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOOOOO|(% style="width:225px" %)0~~303237| 1459 +|Bit|(% style="width:191px" %)M|(% style="width:217px" %)M|(% style="width:168px" %)MDDDDD|(% style="width:225px" %)0~~99999| 1460 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999| 1461 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)0~~99999| 1462 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDDD|(% style="width:225px" %)0~~99999| 1463 +|Word|(% style="width:191px" %)D|(% style="width:217px" %)D|(% style="width:168px" %)D DDDDD|(% style="width:225px" %)0~~99999| 1464 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999| 1465 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199| 1466 +|Double Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)200~~99999| 1467 + 1468 +(% class="wikigeneratedid" %) 1469 +**3)Wiring Diagram** 1470 + 1471 +(% style="text-align:center" %) 1472 +[[image:Delta DVP PROTOCOLSerial232.png]] 1473 + 1184 1184 == **AS Ethernet Protocol** == 1185 1185 1186 1186 **1)V-BOX Settings** ... ... @@ -1214,7 +1214,6 @@ 1214 1214 1215 1215 **3)Configure the communication protocol** 1216 1216 1217 - 1218 1218 [[image:image-20220831160010-4.png]] 1219 1219 1220 1220 **4)Cable Wiring** ... ... @@ -1347,7 +1347,7 @@ 1347 1347 1348 1348 **1)V-BOX Settings** 1349 1349 1350 -Supported Series: DeltaXinjie XD/XE Series PLC1639 +Supported Series: Xinjie XD/XE Series PLC 1351 1351 1352 1352 |**Item**|**Settings**|**Note** 1353 1353 |Protocol|XINJE XD/XC MODBUS| ... ... @@ -1417,7 +1417,6 @@ 1417 1417 1418 1418 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]] 1419 1419 1420 - 1421 1421 = Create communication with **Schneider PLC** = 1422 1422 1423 1423 == **Schneider MODBUS RTU** == ... ... @@ -1674,8 +1674,8 @@ 1674 1674 **address list** 1675 1675 1676 1676 (% class="table-bordered" %) 1677 -|** type**|**register**|**Function code and description**1678 -|(% rowspan="11" %) 词|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)1965 +|=(% scope="row" %)**Type**|=**Data Type**|=**Function code and description** 1966 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers) 1679 1679 |06 (write single register: write a binary value to a holding register) 1680 1680 |10 (write values to multiple addresses ) 1681 1681 |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) ... ... @@ -1714,7 +1714,7 @@ 1714 1714 1715 1715 **2)Address List** 1716 1716 1717 -|**Type**|** Register**|**Function code & Description**2005 +|=**Type**|=**Data Type**|=**Function code & Description** 1718 1718 |(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 1719 1719 |06 (write single register: write a binary value to a holding register) 1720 1720 |10 (write values to multiple addresses )
- 0Il1q9GZgk.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.6 KB - Content
- AB.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.3 KB - Content
- ABRS232.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.3 KB - Content
- DVPEthernetAutoSearch.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.6 KB - Content
- DVPEthernetPLCtoPC.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.9 KB - Content
- DVPEthernetSetup.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.9 KB - Content
- DVPEthernetTransfer.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +59.9 KB - Content
- DVPEthernetVNETPortocol.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.4 KB - Content
- DVPEthernetWPLSoft.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +97.5 KB - Content
- DVPEthernetWPLSoft2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +45.2 KB - Content
- Delta DVP PROTOCOLSerial232.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.7 KB - Content
- LldwDGntf4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.3 KB - Content
- WgvjfWbQif.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.3 KB - Content