Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 10 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -178,6 +178,102 @@ 178 178 179 179 = Create communication with **Rockwell PLC** = 180 180 181 +== **DF1 Advanced Protocol** == 182 + 183 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 184 + 185 +**1) V-Box Settings** 186 + 187 +|=Item|=Recommended |=Note 188 +|=Protocol|Allen Bradley DF1 Advanced| 189 +|=Connection|RS232| 190 +|=Baud rate|19200| 191 +|=Stop bits|1| 192 +|=Data bits|8| 193 +|=Parity|None| 194 +|=PLC Station No.|1| 195 +|=HMI Station No.|0| 196 + 197 +**2) Address List** 198 + 199 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note 200 +|(% colspan="1" rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1 201 +|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0 202 +|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2 203 +|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3 204 +|BN|BNddddd.dd|0.0~~99255.15|((( 205 +Bit data file B0~~B99 206 + 207 +First two digits is for file number 208 + 209 +For example, BN13001.00 represents file number B13, address 001, the 0th bit. 210 +))) 211 +|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7 212 +|NN|NNddddd.dd|0.0~~99255.15|((( 213 +Integer data file bit format N0~~N99 214 + 215 +First two digits is for file number 216 + 217 +For example, NN13001.00 represents file number N13, address 001, the 0th bit. 218 +))) 219 +|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2 220 +|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value) 221 +|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value) 222 +|TNS|TNSddddd|0~~99255|((( 223 +Timer Preset Value 224 + 225 +First two digits is for file number 226 + 227 +For example, TNS99255 represents file number T99, address 255. 228 +))) 229 +|TNP|TNPddddd|0~~99255|((( 230 +Timer Accumulator Value 231 + 232 +First two digits is for file number 233 + 234 +For example, TNP99255 represents file number T99, address 255. 235 +))) 236 +|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value) 237 +|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value) 238 +|CNS|CNSddddd|0~~99255|((( 239 +Counter Preset Value 240 + 241 +First two digits is for file number 242 + 243 +For example, CNS99255 represents file number C99, address 255. 244 +))) 245 +|CNP|CNPddddd|0~~99255|((( 246 +Counter Accumulator Value 247 + 248 +First two digits is for file number 249 + 250 +For example, CNP99255 represents file number C99, address 255. 251 +))) 252 +|N7|N7ddd|0~~255|Only able to communicate with file number N7 253 +|NN|NNddd|0~~99255|((( 254 +Integer data file 255 + 256 +First two digits is for file number 257 + 258 +For example, NN99255 represents file number N99, address 255. 259 +))) 260 +|(% colspan="1" rowspan="3" %)Double Word|F8|F8ddd|0~~255|((( 261 +Only able to communicate with file number N7 262 +))) 263 +|FN|FNddddd|0~~99255|((( 264 +Floating point data file 265 + 266 +First two digits is for file number 267 + 268 +For example, FN99255 represents file number F99, address 255. 269 +))) 270 +|LN|LNddddd|0~~99255|Long 271 + 272 +**3) Cable Wiring** 273 + 274 +(% style="text-align:center" %) 275 +[[image:ABRS232.gif]] 276 + 181 181 == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 182 182 183 183 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 ... ... @@ -185,7 +185,7 @@ 185 185 **1)V-BOX setting** 186 186 187 187 |**Item**|**Settings**|**Note** 188 -|Protocol|Allen-Bradl ley DF1 Advanced|284 +|Protocol|Allen-Bradley DF1 Advanced| 189 189 |Connection|RS232| 190 190 |Baud rate|19200| 191 191 |Data bit|8| ... ... @@ -608,6 +608,46 @@ 608 608 609 609 [[image:image-20220824162342-2.png]] 610 610 707 +== **LOGO Ethernet Protocol** == 708 + 709 +Supported Series: Siemens Logo 0BA0, 0BA1 series 710 + 711 +**V-BOX Settings** 712 + 713 + 714 +|**Items**|**Settings**|**Note** 715 +|Protocol|Siemens LOGO| 716 +|Connection|Ethernet| 717 +|Port No.|102| 718 +|PLC station No.|2| 719 + 720 +**Address List** 721 + 722 + 723 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address** 724 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0 725 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000 726 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000 727 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000 728 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0 729 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770 730 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0 731 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180 732 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040 733 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000 734 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140 735 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280 736 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0 737 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70 738 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000 739 + 740 + **PLC Settings in LOGO Software:** 741 + 742 +Click [Tools]~-~-[Ethernet Connections],shown as below. 743 + 744 +(% style="text-align:center" %) 745 +[[image:12.PLC Protocol_html_8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]] 746 + 611 611 = Create communication with **Mitsubishi PLC** = 612 612 613 613 == **FX1S,1N,2N Serial Protocol** == ... ... @@ -1175,12 +1175,105 @@ 1175 1175 1176 1176 == **DVP Ethernet Protocol** == 1177 1177 1178 - [[Downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]1314 +Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module 1179 1179 1316 +**1)V-BOX Settings** 1317 + 1318 +|=**Items**|=**Settings**|=**Note** 1319 +|Protocol|DELTA DVP MODBUS TCP| 1320 +|Connection|Ethernet| 1321 +|Port No.|502| 1322 +|Device No.|1| 1323 +|VBox Device No.|0| 1324 + 1325 +**2)Address List ** 1326 + 1327 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note** 1328 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOO|(% style="width:225px" %)0~~377| 1329 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOO|(% style="width:225px" %)0~~377| 1330 +|Bit|(% style="width:191px" %)M0|(% style="width:217px" %)M0|(% style="width:168px" %)M0DDDD|(% style="width:225px" %)0~~1535| 1331 +|Bit|(% style="width:191px" %)M1|(% style="width:217px" %)M1|(% style="width:168px" %)M1DDDD|(% style="width:225px" %)1536~~4096| 1332 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255| 1333 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~255| 1334 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDD|(% style="width:225px" %)0~~1023| 1335 +|Word|(% style="width:191px" %)D0|(% style="width:217px" %)D0|(% style="width:168px" %)D0DDDD|(% style="width:225px" %)0~~4095| 1336 +|Word|(% style="width:191px" %)D1|(% style="width:217px" %)D1|(% style="width:168px" %)D1DDDD|(% style="width:225px" %)4096~~11999| 1337 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255| 1338 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199| 1339 +|Double Word|(% style="width:191px" %)HC|(% style="width:217px" %)HC|(% style="width:168px" %)HCDDD|(% style="width:225px" %)200~~255| 1340 + 1341 +**3) PLC Setting:** 1342 + 1343 +~1. Create new project in Delta WPL Soft, and click Setting to open the communication settings: 1344 + 1345 +(% style="text-align:center" %) 1346 +[[image:DVPEthernetWPLSoft2.png]] 1347 + 1348 +2. Set up the communication type and PLC IP: 1349 + 1350 +(% style="text-align:center" %) 1351 +[[image:DVPEthernetSetup.png]] 1352 + 1353 +(% class="wikigeneratedid" %) 1354 +3. Click OK and save the settings. Then click Communication on toolbar, then click Transfer Setup to open new window: 1355 + 1356 +(% style="text-align:center" %) 1357 +[[image:DVPEthernetTransfer.png]] 1358 + 1359 +(% class="wikigeneratedid" %) 1360 +4. Select Communication Mode as PC => PLC to download or select PC <=PLC to upload: 1361 + 1362 +(% style="text-align:center" %) 1363 +[[image:DVPEthernetPLCtoPC.png]] 1364 + 1365 +5. Click Auto-Search Ethernet Module to find the PLC on the same LAN network: 1366 + 1367 +(% style="text-align:center" %) 1368 +[[image:DVPEthernetAutoSearch.png]] 1369 + 1370 +**4) V-BOX Setting:** 1371 + 1372 +Set the same IP address according to the setting from WPL Soft: 1373 + 1374 +(% style="text-align:center" %) 1375 +[[image:DVPEthernetVNETPortocol.png]] 1376 + 1180 1180 == **DVP serial protocol** == 1181 1181 1182 - [[Downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]1379 +Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX 1183 1183 1381 +**1)V-BOX Settings** 1382 + 1383 +|=**Items**|=**Settings**|=**Note** 1384 +|Protocol|DELTA DVP PROTOCOL| 1385 +|Connection|RS232| 1386 +|Baud Rate|9600| 1387 +|Stop Bit|1| 1388 +|Data Bit|7| 1389 +|Parity|EVEN| 1390 +|Device No.|1| 1391 + 1392 +(% class="wikigeneratedid" %) 1393 +**2)Address List** 1394 + 1395 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note** 1396 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOOOOO|(% style="width:225px" %)0~~303237| 1397 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOOOOO|(% style="width:225px" %)0~~303237| 1398 +|Bit|(% style="width:191px" %)M|(% style="width:217px" %)M|(% style="width:168px" %)MDDDDD|(% style="width:225px" %)0~~99999| 1399 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999| 1400 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)0~~99999| 1401 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDDD|(% style="width:225px" %)0~~99999| 1402 +|Word|(% style="width:191px" %)D|(% style="width:217px" %)D|(% style="width:168px" %)D DDDDD|(% style="width:225px" %)0~~99999| 1403 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999| 1404 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199| 1405 +|Double Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)200~~99999| 1406 + 1407 +(% class="wikigeneratedid" %) 1408 +**3)Wiring Diagram** 1409 + 1410 +(% style="text-align:center" %) 1411 +[[image:Delta DVP PROTOCOLSerial232.png]] 1412 + 1184 1184 == **AS Ethernet Protocol** == 1185 1185 1186 1186 **1)V-BOX Settings** ... ... @@ -1214,7 +1214,6 @@ 1214 1214 1215 1215 **3)Configure the communication protocol** 1216 1216 1217 - 1218 1218 [[image:image-20220831160010-4.png]] 1219 1219 1220 1220 **4)Cable Wiring** ... ... @@ -1673,8 +1673,8 @@ 1673 1673 **address list** 1674 1674 1675 1675 (% class="table-bordered" %) 1676 -|** type**|**register**|**Function code and description**1677 -|(% rowspan="11" %) 词|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)1904 +|=(% scope="row" %)**Type**|=**Data Type**|=**Function code and description** 1905 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers) 1678 1678 |06 (write single register: write a binary value to a holding register) 1679 1679 |10 (write values to multiple addresses ) 1680 1680 |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) ... ... @@ -1713,7 +1713,7 @@ 1713 1713 1714 1714 **2)Address List** 1715 1715 1716 -|**Type**|** Register**|**Function code & Description**1944 +|=**Type**|=**Data Type**|=**Function code & Description** 1717 1717 |(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 1718 1718 |06 (write single register: write a binary value to a holding register) 1719 1719 |10 (write values to multiple addresses )
- AB.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.3 KB - Content
- ABRS232.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.3 KB - Content
- DVPEthernetAutoSearch.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.6 KB - Content
- DVPEthernetPLCtoPC.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.9 KB - Content
- DVPEthernetSetup.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.9 KB - Content
- DVPEthernetTransfer.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +59.9 KB - Content
- DVPEthernetVNETPortocol.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.4 KB - Content
- DVPEthernetWPLSoft.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +97.5 KB - Content
- DVPEthernetWPLSoft2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +45.2 KB - Content
- Delta DVP PROTOCOLSerial232.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.7 KB - Content