Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -176,16 +176,118 @@ 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 178 178 179 -= Create communication with **Rockwell PLC** = 180 180 181 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 182 182 181 += Create communication with Allen-Bradley(**Rockwell**)** PLC** = 182 + 183 +== **DF1 Advanced Protocol** == 184 + 185 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 186 + 187 +**1) V-Box Settings** 188 + 189 +|=Item|=Recommended |=Note 190 +|=Protocol|Allen Bradley DF1 Advanced| 191 +|=Connection|RS232| 192 +|=Baud rate|19200| 193 +|=Stop bits|1| 194 +|=Data bits|8| 195 +|=Parity|None| 196 +|=PLC Station No.|1| 197 +|=HMI Station No.|0| 198 + 199 +**2) Address List** 200 + 201 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note 202 +|(% colspan="1" rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1 203 +|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0 204 +|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2 205 +|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3 206 +|BN|BNddddd.dd|0.0~~99255.15|((( 207 +Bit data file B0~~B99 208 + 209 +First two digits is for file number 210 + 211 +For example, BN13001.00 represents file number B13, address 001, the 0th bit. 212 +))) 213 +|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7 214 +|NN|NNddddd.dd|0.0~~99255.15|((( 215 +Integer data file bit format N0~~N99 216 + 217 +First two digits is for file number 218 + 219 +For example, NN13001.00 represents file number N13, address 001, the 0th bit. 220 +))) 221 +|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2 222 +|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value) 223 +|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value) 224 +|TNS|TNSddddd|0~~99255|((( 225 +Timer Preset Value 226 + 227 +First two digits is for file number 228 + 229 +For example, TNS99255 represents file number T99, address 255. 230 +))) 231 +|TNP|TNPddddd|0~~99255|((( 232 +Timer Accumulator Value 233 + 234 +First two digits is for file number 235 + 236 +For example, TNP99255 represents file number T99, address 255. 237 +))) 238 +|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value) 239 +|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value) 240 +|CNS|CNSddddd|0~~99255|((( 241 +Counter Preset Value 242 + 243 +First two digits is for file number 244 + 245 +For example, CNS99255 represents file number C99, address 255. 246 +))) 247 +|CNP|CNPddddd|0~~99255|((( 248 +Counter Accumulator Value 249 + 250 +First two digits is for file number 251 + 252 +For example, CNP99255 represents file number C99, address 255. 253 +))) 254 +|N7|N7ddd|0~~255|Only able to communicate with file number N7 255 +|NN|NNddd|0~~99255|((( 256 +Integer data file 257 + 258 +First two digits is for file number 259 + 260 +For example, NN99255 represents file number N99, address 255. 261 +))) 262 +|(% colspan="1" rowspan="3" %)Double Word|F8|F8ddd|0~~255|((( 263 +Only able to communicate with file number N7 264 +))) 265 +|FN|FNddddd|0~~99255|((( 266 +Floating point data file 267 + 268 +First two digits is for file number 269 + 270 +For example, FN99255 represents file number F99, address 255. 271 +))) 272 +|LN|LNddddd|0~~99255|Long 273 + 274 +**3) Cable Wiring** 275 + 276 +(% style="text-align:center" %) 277 +[[image:ABRS232.gif]] 278 + 279 +(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %) 280 +(% id="cke_bm_5621S" style="display:none" %)** ** 281 + 282 +== **MicroLogix Protocol** == 283 + 284 +(% class="wikigeneratedid" %) 183 183 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 184 184 185 185 **1)V-BOX setting** 186 186 187 187 |**Item**|**Settings**|**Note** 188 -|Protocol|Allen-Bradl ley DF1 Advanced|290 +|Protocol|Allen-Bradley DF1 Advanced| 189 189 |Connection|RS232| 190 190 |Baud rate|19200| 191 191 |Data bit|8| ... ... @@ -424,7 +424,13 @@ 424 424 425 425 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 426 426 529 += Create communication with **Crouzet PLC** = 427 427 531 +== **CROUZET M3 (FBD)** == 532 + 533 +**1)V-BOX setting** 534 + 535 + 428 428 = Create communication with **Siemens PLC** = 429 429 430 430 == **S7-200 Smart Ethernet Protocol** == ... ... @@ -608,6 +608,97 @@ 608 608 609 609 [[image:image-20220824162342-2.png]] 610 610 719 +== **LOGO Ethernet Protocol** == 720 + 721 +Supported Series: Siemens Logo 0BA0, 0BA1 series 722 + 723 +**V-BOX Settings** 724 + 725 + 726 +|**Items**|**Settings**|**Note** 727 +|Protocol|Siemens LOGO| 728 +|Connection|Ethernet| 729 +|Port No.|102| 730 +|PLC station No.|2| 731 + 732 +**Address List** 733 + 734 + 735 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address** 736 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0 737 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000 738 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000 739 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000 740 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0 741 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770 742 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0 743 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180 744 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040 745 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000 746 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140 747 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280 748 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0 749 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70 750 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000 751 + 752 +**PLC Settings in LOGO Software:** 753 + 754 +Click [Tools]~-~-[Ethernet Connections],shown as below. 755 + 756 +(% style="text-align:center" %) 757 +[[image:PIStudio.12\.PLC protocols.WebHome@12.PLC Protocol_html_8b9d2322edf89519.png]] 758 + 759 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 760 + 761 +(% style="text-align:center" %) 762 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228142937-4.png]] 763 + 764 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 765 + 766 +(% style="text-align:center" %) 767 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143047-5.png]] 768 + 769 + **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 770 + 771 +(% style="text-align:center" %) 772 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143246-6.png]] 773 + 774 +**V-BOX Communication Settings** 775 + 776 +Set PLC IP in [IP Address] settings; 777 + 778 +(% style="text-align:center" %) 779 +[[image:LldwDGntf4.png]] 780 + 781 +Enable V-BOX Ethernet in [Network]; 782 + 783 +(% style="text-align:center" %) 784 +[[image:WgvjfWbQif.png]] 785 + 786 +TSAP setting 787 + 788 +* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful. 789 + 790 +{{code language="LUA"}} 791 +function init.main() 792 +addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address 793 +addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address 794 +end 795 +{{/code}} 796 + 797 +Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 798 + 799 +**✎Note:** 800 + 801 +* **Communication port configuration: ** 802 +** Continuous length needs to be set to 0. 803 +** Integration interval needs to be set to 1. (no change may result in data errors) 804 +** Set Port and Device Station NO. 805 +** Other set as defaulted. 806 +* **Notes on the use of registers:** 807 +** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc. 808 +** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 ) 809 + 611 611 = Create communication with **Mitsubishi PLC** = 612 612 613 613 == **FX1S,1N,2N Serial Protocol** == ... ... @@ -1175,7 +1175,7 @@ 1175 1175 1176 1176 == **DVP Ethernet Protocol** == 1177 1177 1178 -Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE, DELTA DVPEN01-SL 1377 +Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module 1179 1179 1180 1180 **1)V-BOX Settings** 1181 1181 ... ... @@ -1188,19 +1188,19 @@ 1188 1188 1189 1189 **2)Address List ** 1190 1190 1191 -|=**Type**|=(% style="width: 215px;" %)**Device registers**|=(% style="width: 237px;" %)**VBox registers**|=(% style="width:214px;" %)**Format**|=**Range**|=**Note**1192 -|Bit|(% style="width: 215px" %)X|(% style="width:237px" %)X|(% style="width:214px" %)X OOO|0~~377|1193 -|Bit|(% style="width: 215px" %)Y|(% style="width:237px" %)Y|(% style="width:214px" %)Y OOO|0~~377|1194 -|Bit|(% style="width: 215px" %)M0|(% style="width:237px" %)M0|(% style="width:214px" %)M0DDDD|0~~1535|1195 -|Bit|(% style="width: 215px" %)M1|(% style="width:237px" %)M1|(% style="width:214px" %)M1DDDD|1536~~4096|1196 -|Bit|(% style="width: 215px" %)T|(% style="width:237px" %)T|(% style="width:214px" %)TDDD|0~~255|1197 -|Bit|(% style="width: 215px" %)C|(% style="width:237px" %)C|(% style="width:214px" %)CDDD|0~~255|1198 -|Bit|(% style="width: 215px" %)S|(% style="width:237px" %)S|(% style="width:214px" %)SDDDD|0~~1023|1199 -|Word|(% style="width: 215px" %)D0|(% style="width:237px" %)D0|(% style="width:214px" %)D0DDDD|0~~4095|1200 -|Word|(% style="width: 215px" %)D1|(% style="width:237px" %)D1|(% style="width:214px" %)D1DDDD|4096~~11999|1201 -|Word|(% style="width: 215px" %)T|(% style="width:237px" %)T|(% style="width:214px" %)TDDD|0~~255|1202 -|Word|(% style="width: 215px" %)C|(% style="width:237px" %)C|(% style="width:214px" %)CDDD|0~~199|1203 -|Double Word|(% style="width: 215px" %)HC|(% style="width:237px" %)HC|(% style="width:214px" %)HCDDD|200~~255|1390 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note** 1391 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOO|(% style="width:225px" %)0~~377| 1392 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOO|(% style="width:225px" %)0~~377| 1393 +|Bit|(% style="width:191px" %)M0|(% style="width:217px" %)M0|(% style="width:168px" %)M0DDDD|(% style="width:225px" %)0~~1535| 1394 +|Bit|(% style="width:191px" %)M1|(% style="width:217px" %)M1|(% style="width:168px" %)M1DDDD|(% style="width:225px" %)1536~~4096| 1395 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255| 1396 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~255| 1397 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDD|(% style="width:225px" %)0~~1023| 1398 +|Word|(% style="width:191px" %)D0|(% style="width:217px" %)D0|(% style="width:168px" %)D0DDDD|(% style="width:225px" %)0~~4095| 1399 +|Word|(% style="width:191px" %)D1|(% style="width:217px" %)D1|(% style="width:168px" %)D1DDDD|(% style="width:225px" %)4096~~11999| 1400 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255| 1401 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199| 1402 +|Double Word|(% style="width:191px" %)HC|(% style="width:217px" %)HC|(% style="width:168px" %)HCDDD|(% style="width:225px" %)200~~255| 1204 1204 1205 1205 **3) PLC Setting:** 1206 1206 ... ... @@ -1233,12 +1233,47 @@ 1233 1233 1234 1234 **4) V-BOX Setting:** 1235 1235 1236 - 1435 +Set the same IP address according to the setting from WPL Soft: 1237 1237 1437 +(% style="text-align:center" %) 1438 +[[image:DVPEthernetVNETPortocol.png]] 1439 + 1238 1238 == **DVP serial protocol** == 1239 1239 1240 - [[Downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]1442 +Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX 1241 1241 1444 +**1)V-BOX Settings** 1445 + 1446 +|=**Items**|=**Settings**|=**Note** 1447 +|Protocol|DELTA DVP PROTOCOL| 1448 +|Connection|RS232| 1449 +|Baud Rate|9600| 1450 +|Stop Bit|1| 1451 +|Data Bit|7| 1452 +|Parity|EVEN| 1453 +|Device No.|1| 1454 + 1455 +(% class="wikigeneratedid" %) 1456 +**2)Address List** 1457 + 1458 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note** 1459 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOOOOO|(% style="width:225px" %)0~~303237| 1460 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOOOOO|(% style="width:225px" %)0~~303237| 1461 +|Bit|(% style="width:191px" %)M|(% style="width:217px" %)M|(% style="width:168px" %)MDDDDD|(% style="width:225px" %)0~~99999| 1462 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999| 1463 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)0~~99999| 1464 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDDD|(% style="width:225px" %)0~~99999| 1465 +|Word|(% style="width:191px" %)D|(% style="width:217px" %)D|(% style="width:168px" %)D DDDDD|(% style="width:225px" %)0~~99999| 1466 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999| 1467 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199| 1468 +|Double Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)200~~99999| 1469 + 1470 +(% class="wikigeneratedid" %) 1471 +**3)Wiring Diagram** 1472 + 1473 +(% style="text-align:center" %) 1474 +[[image:Delta DVP PROTOCOLSerial232.png]] 1475 + 1242 1242 == **AS Ethernet Protocol** == 1243 1243 1244 1244 **1)V-BOX Settings** ... ... @@ -1730,8 +1730,8 @@ 1730 1730 **address list** 1731 1731 1732 1732 (% class="table-bordered" %) 1733 -|** type**|**register**|**Function code and description**1734 -|(% rowspan="11" %) 词|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)1967 +|=(% scope="row" %)**Type**|=**Data Type**|=**Function code and description** 1968 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers) 1735 1735 |06 (write single register: write a binary value to a holding register) 1736 1736 |10 (write values to multiple addresses ) 1737 1737 |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) ... ... @@ -1770,7 +1770,7 @@ 1770 1770 1771 1771 **2)Address List** 1772 1772 1773 -|**Type**|** Register**|**Function code & Description**2007 +|=**Type**|=**Data Type**|=**Function code & Description** 1774 1774 |(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 1775 1775 |06 (write single register: write a binary value to a holding register) 1776 1776 |10 (write values to multiple addresses )
- 0Il1q9GZgk.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.6 KB - Content
- AB.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.3 KB - Content
- ABRS232.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.3 KB - Content
- DVPEthernetVNETPortocol.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.4 KB - Content
- Delta DVP PROTOCOLSerial232.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.7 KB - Content
- LldwDGntf4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.3 KB - Content
- WgvjfWbQif.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.3 KB - Content