Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 191.2
edited by Hunter
on 2022/12/01 11:13
Change comment: There is no comment for this version
To version 179.1
edited by Hunter
on 2022/11/19 10:08
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -420,7 +420,7 @@
420 420  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
421 421  
422 422  
423 -= **Allen-Bradley Ethernet DF1** =
423 +== **Allen-Bradley Ethernet DF1** ==
424 424  
425 425  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
426 426  
... ... @@ -797,7 +797,7 @@
797 797  
798 798  **4)Configure the communication protocol**
799 799  
800 -[[image:image-20221119101946-2.png||height="395" width="695"]]
800 +[[image:image-20221116114106-1.png||height="397" width="701"]]
801 801  
802 802  == **FX5U Serial Protocol** ==
803 803  
... ... @@ -1090,12 +1090,6 @@
1090 1090  
1091 1091  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1092 1092  
1093 -== **Q12H Serial Protocol** ==
1094 -
1095 -This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
1096 -
1097 -[[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]
1098 -
1099 1099  == **QJ71E71 Ethernet Protocol** ==
1100 1100  
1101 1101  Mitsubishi QJ71E71 Ethernet communication module;
... ... @@ -1144,13 +1144,10 @@
1144 1144  
1145 1145  * Click [Ethernet/CC IE/MELSECNET];
1146 1146  * Please select [Ethernet] as network type;
1147 -* Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
1141 +* Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order);
1148 1148  * Select [Online] as Mode;
1149 -* [[image:image-20221119171343-2.png||height="341" width="587"]]
1150 1150  * Click [Operation setting] to set IP;
1151 1151  * Select [Binary Code] as [Communication Data Code];
1152 -* [[image:image-20221119171436-3.png||height="354" width="588"]]
1153 -* Click [Open setting]
1154 1154  * Set protocol: TCP;
1155 1155  * Set [unpassive] in [Open system];
1156 1156  * Set [receive] in [Fixed buffer];
... ... @@ -1157,16 +1157,14 @@
1157 1157  * Set [procedure Exist] in [Fixed buffer communication];
1158 1158  * Disable [Pairing open];
1159 1159  * Set [No confirm] in [Existence confirmation];
1160 -* Host station port number: 5009;
1151 +* Host station port number: 1025;
1161 1161  * Save settings;
1162 -* [[image:image-20221119171611-4.png||height="354" width="588"]]
1163 1163  * Download project into PLC and restart it
1164 1164  
1165 1165  **4)Configure the communication protocol**
1166 1166  
1167 -[[image:image-20221119171832-5.png||height="354" width="625"]]
1157 +[[image:image-20220825143728-1.png]]
1168 1168  
1169 -
1170 1170  **5)Cable Wiring**
1171 1171  
1172 1172  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
... ... @@ -1175,20 +1175,11 @@
1175 1175  
1176 1176  == **DVP Ethernet Protocol** ==
1177 1177  
1178 -Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE, DELTA DVPEN01-SL
1167 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1179 1179  
1180 -**1)V-BOX Settings**
1181 -
1182 -|=**Items**|=**Settings**|=**Note**
1183 -|Protocol|DELTA DVP MODBUS TCP|
1184 -|Connection|Ethernet|
1185 -|Port No.|502|
1186 -|Device No.|1|
1187 -|HMI No.|0|
1188 -
1189 1189  == **DVP serial protocol** ==
1190 1190  
1191 -[[Download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1171 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1192 1192  
1193 1193  == **AS Ethernet Protocol** ==
1194 1194  
... ... @@ -1356,7 +1356,7 @@
1356 1356  
1357 1357  **1)V-BOX Settings**
1358 1358  
1359 -Supported Series: Xinjie XD/XE Series PLC
1339 +Supported Series: Delta Xinjie XD/XE Series PLC
1360 1360  
1361 1361  |**Item**|**Settings**|**Note**
1362 1362  |Protocol|XINJE XD/XC MODBUS|
... ... @@ -1426,6 +1426,7 @@
1426 1426  
1427 1427  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1428 1428  
1409 +
1429 1429  = Create communication with **Schneider PLC** =
1430 1430  
1431 1431  == **Schneider MODBUS RTU** ==
image-20221119101759-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -62.1 KB
Content
image-20221119101946-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -68.7 KB
Content
image-20221119171318-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -90.3 KB
Content
image-20221119171343-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -90.3 KB
Content
image-20221119171436-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -43.4 KB
Content
image-20221119171611-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -23.1 KB
Content
image-20221119171832-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -69.6 KB
Content