Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 10 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -178,6 +178,102 @@ 178 178 179 179 = Create communication with **Rockwell PLC** = 180 180 181 +== **DF1 Advanced Protocol** == 182 + 183 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 184 + 185 +**1) V-Box Settings** 186 + 187 +|=Item|=Recommended |=Note 188 +|=Protocol|Allen Bradley DF1 Advanced| 189 +|=Connection|RS232| 190 +|=Baud rate|19200| 191 +|=Stop bits|1| 192 +|=Data bits|8| 193 +|=Parity|None| 194 +|=PLC Station No.|1| 195 +|=HMI Station No.|0| 196 + 197 +**2) Address List** 198 + 199 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note 200 +|(% colspan="1" rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1 201 +|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0 202 +|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2 203 +|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3 204 +|BN|BNddddd.dd|0.0~~99255.15|((( 205 +Bit data file B0~~B99 206 + 207 +First two digits is for file number 208 + 209 +For example, BN13001.00 represents file number B13, address 001, the 0th bit. 210 +))) 211 +|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7 212 +|NN|NNddddd.dd|0.0~~99255.15|((( 213 +Integer data file bit format N0~~N99 214 + 215 +First two digits is for file number 216 + 217 +For example, NN13001.00 represents file number N13, address 001, the 0th bit. 218 +))) 219 +|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2 220 +|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value) 221 +|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value) 222 +|TNS|TNSddddd|0~~99255|((( 223 +Timer Preset Value 224 + 225 +First two digits is for file number 226 + 227 +For example, TNS99255 represents file number T99, address 255. 228 +))) 229 +|TNP|TNPddddd|0~~99255|((( 230 +Timer Accumulator Value 231 + 232 +First two digits is for file number 233 + 234 +For example, TNP99255 represents file number T99, address 255. 235 +))) 236 +|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value) 237 +|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value) 238 +|CNS|CNSddddd|0~~99255|((( 239 +Counter Preset Value 240 + 241 +First two digits is for file number 242 + 243 +For example, CNS99255 represents file number C99, address 255. 244 +))) 245 +|CNP|CNPddddd|0~~99255|((( 246 +Counter Accumulator Value 247 + 248 +First two digits is for file number 249 + 250 +For example, CNP99255 represents file number C99, address 255. 251 +))) 252 +|N7|N7ddd|0~~255|Only able to communicate with file number N7 253 +|NN|NNddd|0~~99255|((( 254 +Integer data file 255 + 256 +First two digits is for file number 257 + 258 +For example, NN99255 represents file number N99, address 255. 259 +))) 260 +|(% colspan="1" rowspan="3" %)Double Word|F8|F8ddd|0~~255|((( 261 +Only able to communicate with file number N7 262 +))) 263 +|FN|FNddddd|0~~99255|((( 264 +Floating point data file 265 + 266 +First two digits is for file number 267 + 268 +For example, FN99255 represents file number F99, address 255. 269 +))) 270 +|LN|LNddddd|0~~99255|Long 271 + 272 +**3) Cable Wiring** 273 + 274 +(% style="text-align:center" %) 275 +[[image:ABRS232.gif]] 276 + 181 181 == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 182 182 183 183 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 ... ... @@ -185,7 +185,7 @@ 185 185 **1)V-BOX setting** 186 186 187 187 |**Item**|**Settings**|**Note** 188 -|Protocol|Allen-Bradl ley DF1 Advanced|284 +|Protocol|Allen-Bradley DF1 Advanced| 189 189 |Connection|RS232| 190 190 |Baud rate|19200| 191 191 |Data bit|8| ... ... @@ -1175,7 +1175,7 @@ 1175 1175 1176 1176 == **DVP Ethernet Protocol** == 1177 1177 1178 -Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE, DELTA DVPEN01-SL 1274 +Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module 1179 1179 1180 1180 **1)V-BOX Settings** 1181 1181 ... ... @@ -1188,21 +1188,92 @@ 1188 1188 1189 1189 **2)Address List ** 1190 1190 1191 -|=**Type**|=(% style="width: 215px;" %)**Device registers**|=(% style="width: 237px;" %)**VBox registers**|=(% style="width: 214px;" %)**Format**|=**Range**|=**Note** 1192 -|Bit|(% style="width:215px" %)X|(% style="width:237px" %)X|(% style="width:214px" %)X OOO|0~~377| 1193 -|Bit|(% style="width:215px" %)Y|(% style="width:237px" %)Y|(% style="width:214px" %)Y OOO|0~~377| 1194 -|Bit|(% style="width:215px" %)M0|(% style="width:237px" %)M0|(% style="width:214px" %)M0DDDD|0~~1535| 1195 -|Bit|(% style="width:215px" %)M1|(% style="width:237px" %)M1|(% style="width:214px" %)M1DDDD|1536~~4096| 1196 -|Bit|(% style="width:215px" %)T|(% style="width:237px" %)T|(% style="width:214px" %)TDDD|0~~255| 1197 -|Bit|(% style="width:215px" %)C|(% style="width:237px" %)C|(% style="width:214px" %)CDDD|0~~255| 1198 -|Bit|(% style="width:215px" %)S|(% style="width:237px" %)S|(% style="width:214px" %)SDDDD|0~~1023| 1199 -|Word|(% style="width:215px" %)D0|(% style="width:237px" %)D0|(% style="width:214px" %)D0DDDD|0~~4095| 1200 -| |(% style="width:215px" %) |(% style="width:237px" %) |(% style="width:214px" %) | | 1287 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note** 1288 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOO|(% style="width:225px" %)0~~377| 1289 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOO|(% style="width:225px" %)0~~377| 1290 +|Bit|(% style="width:191px" %)M0|(% style="width:217px" %)M0|(% style="width:168px" %)M0DDDD|(% style="width:225px" %)0~~1535| 1291 +|Bit|(% style="width:191px" %)M1|(% style="width:217px" %)M1|(% style="width:168px" %)M1DDDD|(% style="width:225px" %)1536~~4096| 1292 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255| 1293 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~255| 1294 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDD|(% style="width:225px" %)0~~1023| 1295 +|Word|(% style="width:191px" %)D0|(% style="width:217px" %)D0|(% style="width:168px" %)D0DDDD|(% style="width:225px" %)0~~4095| 1296 +|Word|(% style="width:191px" %)D1|(% style="width:217px" %)D1|(% style="width:168px" %)D1DDDD|(% style="width:225px" %)4096~~11999| 1297 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255| 1298 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199| 1299 +|Double Word|(% style="width:191px" %)HC|(% style="width:217px" %)HC|(% style="width:168px" %)HCDDD|(% style="width:225px" %)200~~255| 1201 1201 1301 +**3) PLC Setting:** 1302 + 1303 +~1. Create new project in Delta WPL Soft, and click Setting to open the communication settings: 1304 + 1305 +(% style="text-align:center" %) 1306 +[[image:DVPEthernetWPLSoft2.png]] 1307 + 1308 +2. Set up the communication type and PLC IP: 1309 + 1310 +(% style="text-align:center" %) 1311 +[[image:DVPEthernetSetup.png]] 1312 + 1313 +(% class="wikigeneratedid" %) 1314 +3. Click OK and save the settings. Then click Communication on toolbar, then click Transfer Setup to open new window: 1315 + 1316 +(% style="text-align:center" %) 1317 +[[image:DVPEthernetTransfer.png]] 1318 + 1319 +(% class="wikigeneratedid" %) 1320 +4. Select Communication Mode as PC => PLC to download or select PC <=PLC to upload: 1321 + 1322 +(% style="text-align:center" %) 1323 +[[image:DVPEthernetPLCtoPC.png]] 1324 + 1325 +5. Click Auto-Search Ethernet Module to find the PLC on the same LAN network: 1326 + 1327 +(% style="text-align:center" %) 1328 +[[image:DVPEthernetAutoSearch.png]] 1329 + 1330 +**4) V-BOX Setting:** 1331 + 1332 +Set the same IP address according to the setting from WPL Soft: 1333 + 1334 +(% style="text-align:center" %) 1335 +[[image:DVPEthernetVNETPortocol.png]] 1336 + 1202 1202 == **DVP serial protocol** == 1203 1203 1204 - [[Downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]1339 +Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX 1205 1205 1341 +**1)V-BOX Settings** 1342 + 1343 +|=**Items**|=**Settings**|=**Note** 1344 +|Protocol|DELTA DVP PROTOCOL| 1345 +|Connection|RS232| 1346 +|Baud Rate|9600| 1347 +|Stop Bit|1| 1348 +|Data Bit|7| 1349 +|Parity|EVEN| 1350 +|Device No.|1| 1351 + 1352 +(% class="wikigeneratedid" %) 1353 +**2)Address List** 1354 + 1355 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note** 1356 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOOOOO|(% style="width:225px" %)0~~303237| 1357 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOOOOO|(% style="width:225px" %)0~~303237| 1358 +|Bit|(% style="width:191px" %)M|(% style="width:217px" %)M|(% style="width:168px" %)MDDDDD|(% style="width:225px" %)0~~99999| 1359 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999| 1360 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)0~~99999| 1361 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDDD|(% style="width:225px" %)0~~99999| 1362 +|Word|(% style="width:191px" %)D|(% style="width:217px" %)D|(% style="width:168px" %)D DDDDD|(% style="width:225px" %)0~~99999| 1363 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999| 1364 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199| 1365 +|Double Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)200~~99999| 1366 + 1367 +(% class="wikigeneratedid" %) 1368 +**3)Wiring Diagram** 1369 + 1370 +(% style="text-align:center" %) 1371 +[[image:Delta DVP PROTOCOLSerial232.png]] 1372 + 1206 1206 == **AS Ethernet Protocol** == 1207 1207 1208 1208 **1)V-BOX Settings** ... ... @@ -1236,7 +1236,6 @@ 1236 1236 1237 1237 **3)Configure the communication protocol** 1238 1238 1239 - 1240 1240 [[image:image-20220831160010-4.png]] 1241 1241 1242 1242 **4)Cable Wiring** ... ... @@ -1695,8 +1695,8 @@ 1695 1695 **address list** 1696 1696 1697 1697 (% class="table-bordered" %) 1698 -|** type**|**register**|**Function code and description**1699 -|(% rowspan="11" %) 词|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)1864 +|=(% scope="row" %)**Type**|=**Data Type**|=**Function code and description** 1865 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers) 1700 1700 |06 (write single register: write a binary value to a holding register) 1701 1701 |10 (write values to multiple addresses ) 1702 1702 |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) ... ... @@ -1735,7 +1735,7 @@ 1735 1735 1736 1736 **2)Address List** 1737 1737 1738 -|**Type**|** Register**|**Function code & Description**1904 +|=**Type**|=**Data Type**|=**Function code & Description** 1739 1739 |(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 1740 1740 |06 (write single register: write a binary value to a holding register) 1741 1741 |10 (write values to multiple addresses )
- AB.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.3 KB - Content
- ABRS232.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.3 KB - Content
- DVPEthernetAutoSearch.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.6 KB - Content
- DVPEthernetPLCtoPC.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.9 KB - Content
- DVPEthernetSetup.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.9 KB - Content
- DVPEthernetTransfer.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +59.9 KB - Content
- DVPEthernetVNETPortocol.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.4 KB - Content
- DVPEthernetWPLSoft.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +97.5 KB - Content
- DVPEthernetWPLSoft2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +45.2 KB - Content
- Delta DVP PROTOCOLSerial232.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.7 KB - Content