Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Bob - Content
-
... ... @@ -178,6 +178,102 @@ 178 178 179 179 = Create communication with **Rockwell PLC** = 180 180 181 +== **DF1 Advanced Protocol** == 182 + 183 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 184 + 185 +**1) V-Box Settings** 186 + 187 +|=Item|=Recommended |=Note 188 +|=Protocol|Allen Bradley DF1 Advanced| 189 +|=Connection|RS232| 190 +|=Baud rate|19200| 191 +|=Stop bits|1| 192 +|=Data bits|8| 193 +|=Parity|None| 194 +|=PLC Station No.|1| 195 +|=HMI Station No.|0| 196 + 197 +**2) Address List** 198 + 199 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note 200 +|(% colspan="1" rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1 201 +|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0 202 +|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2 203 +|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3 204 +|BN|BNddddd.dd|0.0~~99255.15|((( 205 +Bit data file B0~~B99 206 + 207 +First two digits is for file number 208 + 209 +For example, BN13001.00 represents file number B13, address 001, the 0th bit. 210 +))) 211 +|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7 212 +|NN|NNddddd.dd|0.0~~99255.15|((( 213 +Integer data file bit format N0~~N99 214 + 215 +First two digits is for file number 216 + 217 +For example, NN13001.00 represents file number N13, address 001, the 0th bit. 218 +))) 219 +|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2 220 +|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value) 221 +|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value) 222 +|TNS|TNSddddd|0~~99255|((( 223 +Timer Preset Value 224 + 225 +First two digits is for file number 226 + 227 +For example, TNS99255 represents file number T99, address 255. 228 +))) 229 +|TNP|TNPddddd|0~~99255|((( 230 +Timer Accumulator Value 231 + 232 +First two digits is for file number 233 + 234 +For example, TNP99255 represents file number T99, address 255. 235 +))) 236 +|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value) 237 +|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value) 238 +|CNS|CNSddddd|0~~99255|((( 239 +Counter Preset Value 240 + 241 +First two digits is for file number 242 + 243 +For example, CNS99255 represents file number C99, address 255. 244 +))) 245 +|CNP|CNPddddd|0~~99255|((( 246 +Counter Accumulator Value 247 + 248 +First two digits is for file number 249 + 250 +For example, CNP99255 represents file number C99, address 255. 251 +))) 252 +|N7|N7ddd|0~~255|Only able to communicate with file number N7 253 +|NN|NNddd|0~~99255|((( 254 +Integer data file 255 + 256 +First two digits is for file number 257 + 258 +For example, NN99255 represents file number N99, address 255. 259 +))) 260 +|(% colspan="1" rowspan="3" %)Double Word|F8|F8ddd|0~~255|((( 261 +Only able to communicate with file number N7 262 +))) 263 +|FN|FNddddd|0~~99255|((( 264 +Floating point data file 265 + 266 +First two digits is for file number 267 + 268 +For example, FN99255 represents file number F99, address 255. 269 +))) 270 +|LN|LNddddd|0~~99255|Long 271 + 272 +**3) Cable Wiring** 273 + 274 +(% style="text-align:center" %) 275 +[[image:ABRS232.gif]] 276 + 181 181 == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 182 182 183 183 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 ... ... @@ -185,7 +185,7 @@ 185 185 **1)V-BOX setting** 186 186 187 187 |**Item**|**Settings**|**Note** 188 -|Protocol|Allen-Bradl ley DF1 Advanced|284 +|Protocol|Allen-Bradley DF1 Advanced| 189 189 |Connection|RS232| 190 190 |Baud rate|19200| 191 191 |Data bit|8| ... ... @@ -608,6 +608,8 @@ 608 608 609 609 [[image:image-20220824162342-2.png]] 610 610 707 +== **LOGO Ethernet Protocol** == 708 + 611 611 = Create communication with **Mitsubishi PLC** = 612 612 613 613 == **FX1S,1N,2N Serial Protocol** == ... ... @@ -1175,7 +1175,7 @@ 1175 1175 1176 1176 == **DVP Ethernet Protocol** == 1177 1177 1178 -Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE, DELTA DVPEN01-SL 1276 +Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module 1179 1179 1180 1180 **1)V-BOX Settings** 1181 1181 ... ... @@ -1188,19 +1188,19 @@ 1188 1188 1189 1189 **2)Address List ** 1190 1190 1191 -|=**Type**|=(% style="width: 215px;" %)**Device registers**|=(% style="width: 237px;" %)**VBox registers**|=(% style="width:214px;" %)**Format**|=**Range**|=**Note**1192 -|Bit|(% style="width: 215px" %)X|(% style="width:237px" %)X|(% style="width:214px" %)X OOO|0~~377|1193 -|Bit|(% style="width: 215px" %)Y|(% style="width:237px" %)Y|(% style="width:214px" %)Y OOO|0~~377|1194 -|Bit|(% style="width: 215px" %)M0|(% style="width:237px" %)M0|(% style="width:214px" %)M0DDDD|0~~1535|1195 -|Bit|(% style="width: 215px" %)M1|(% style="width:237px" %)M1|(% style="width:214px" %)M1DDDD|1536~~4096|1196 -|Bit|(% style="width: 215px" %)T|(% style="width:237px" %)T|(% style="width:214px" %)TDDD|0~~255|1197 -|Bit|(% style="width: 215px" %)C|(% style="width:237px" %)C|(% style="width:214px" %)CDDD|0~~255|1198 -|Bit|(% style="width: 215px" %)S|(% style="width:237px" %)S|(% style="width:214px" %)SDDDD|0~~1023|1199 -|Word|(% style="width: 215px" %)D0|(% style="width:237px" %)D0|(% style="width:214px" %)D0DDDD|0~~4095|1200 -|Word|(% style="width: 215px" %)D1|(% style="width:237px" %)D1|(% style="width:214px" %)D1DDDD|4096~~11999|1201 -|Word|(% style="width: 215px" %)T|(% style="width:237px" %)T|(% style="width:214px" %)TDDD|0~~255|1202 -|Word|(% style="width: 215px" %)C|(% style="width:237px" %)C|(% style="width:214px" %)CDDD|0~~199|1203 -|Double Word|(% style="width: 215px" %)HC|(% style="width:237px" %)HC|(% style="width:214px" %)HCDDD|200~~255|1289 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note** 1290 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOO|(% style="width:225px" %)0~~377| 1291 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOO|(% style="width:225px" %)0~~377| 1292 +|Bit|(% style="width:191px" %)M0|(% style="width:217px" %)M0|(% style="width:168px" %)M0DDDD|(% style="width:225px" %)0~~1535| 1293 +|Bit|(% style="width:191px" %)M1|(% style="width:217px" %)M1|(% style="width:168px" %)M1DDDD|(% style="width:225px" %)1536~~4096| 1294 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255| 1295 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~255| 1296 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDD|(% style="width:225px" %)0~~1023| 1297 +|Word|(% style="width:191px" %)D0|(% style="width:217px" %)D0|(% style="width:168px" %)D0DDDD|(% style="width:225px" %)0~~4095| 1298 +|Word|(% style="width:191px" %)D1|(% style="width:217px" %)D1|(% style="width:168px" %)D1DDDD|(% style="width:225px" %)4096~~11999| 1299 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255| 1300 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199| 1301 +|Double Word|(% style="width:191px" %)HC|(% style="width:217px" %)HC|(% style="width:168px" %)HCDDD|(% style="width:225px" %)200~~255| 1204 1204 1205 1205 **3) PLC Setting:** 1206 1206 ... ... @@ -1226,10 +1226,54 @@ 1226 1226 (% style="text-align:center" %) 1227 1227 [[image:DVPEthernetPLCtoPC.png]] 1228 1228 1327 +5. Click Auto-Search Ethernet Module to find the PLC on the same LAN network: 1328 + 1329 +(% style="text-align:center" %) 1330 +[[image:DVPEthernetAutoSearch.png]] 1331 + 1332 +**4) V-BOX Setting:** 1333 + 1334 +Set the same IP address according to the setting from WPL Soft: 1335 + 1336 +(% style="text-align:center" %) 1337 +[[image:DVPEthernetVNETPortocol.png]] 1338 + 1229 1229 == **DVP serial protocol** == 1230 1230 1231 - [[Downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]1341 +Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX 1232 1232 1343 +**1)V-BOX Settings** 1344 + 1345 +|=**Items**|=**Settings**|=**Note** 1346 +|Protocol|DELTA DVP PROTOCOL| 1347 +|Connection|RS232| 1348 +|Baud Rate|9600| 1349 +|Stop Bit|1| 1350 +|Data Bit|7| 1351 +|Parity|EVEN| 1352 +|Device No.|1| 1353 + 1354 +(% class="wikigeneratedid" %) 1355 +**2)Address List** 1356 + 1357 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note** 1358 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOOOOO|(% style="width:225px" %)0~~303237| 1359 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOOOOO|(% style="width:225px" %)0~~303237| 1360 +|Bit|(% style="width:191px" %)M|(% style="width:217px" %)M|(% style="width:168px" %)MDDDDD|(% style="width:225px" %)0~~99999| 1361 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999| 1362 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)0~~99999| 1363 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDDD|(% style="width:225px" %)0~~99999| 1364 +|Word|(% style="width:191px" %)D|(% style="width:217px" %)D|(% style="width:168px" %)D DDDDD|(% style="width:225px" %)0~~99999| 1365 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999| 1366 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199| 1367 +|Double Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)200~~99999| 1368 + 1369 +(% class="wikigeneratedid" %) 1370 +**3)Wiring Diagram** 1371 + 1372 +(% style="text-align:center" %) 1373 +[[image:Delta DVP PROTOCOLSerial232.png]] 1374 + 1233 1233 == **AS Ethernet Protocol** == 1234 1234 1235 1235 **1)V-BOX Settings** ... ... @@ -1721,8 +1721,8 @@ 1721 1721 **address list** 1722 1722 1723 1723 (% class="table-bordered" %) 1724 -|** type**|**register**|**Function code and description**1725 -|(% rowspan="11" %) 词|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)1866 +|=(% scope="row" %)**Type**|=**Data Type**|=**Function code and description** 1867 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers) 1726 1726 |06 (write single register: write a binary value to a holding register) 1727 1727 |10 (write values to multiple addresses ) 1728 1728 |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) ... ... @@ -1761,7 +1761,7 @@ 1761 1761 1762 1762 **2)Address List** 1763 1763 1764 -|**Type**|** Register**|**Function code & Description**1906 +|=**Type**|=**Data Type**|=**Function code & Description** 1765 1765 |(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 1766 1766 |06 (write single register: write a binary value to a holding register) 1767 1767 |10 (write values to multiple addresses )
- AB.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.3 KB - Content
- ABRS232.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.3 KB - Content
- DVPEthernetAutoSearch.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.6 KB - Content
- DVPEthernetVNETPortocol.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.4 KB - Content
- Delta DVP PROTOCOLSerial232.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.7 KB - Content