Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -178,102 +178,6 @@ 178 178 179 179 = Create communication with **Rockwell PLC** = 180 180 181 -== **DF1 Advanced Protocol** == 182 - 183 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 184 - 185 -**1) V-Box Settings** 186 - 187 -|=Item|=Recommended |=Note 188 -|=Protocol|Allen Bradley DF1 Advanced| 189 -|=Connection|RS232| 190 -|=Baud rate|19200| 191 -|=Stop bits|1| 192 -|=Data bits|8| 193 -|=Parity|None| 194 -|=PLC Station No.|1| 195 -|=HMI Station No.|0| 196 - 197 -**2) Address List** 198 - 199 -|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note 200 -|(% colspan="1" rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1 201 -|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0 202 -|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2 203 -|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3 204 -|BN|BNddddd.dd|0.0~~99255.15|((( 205 -Bit data file B0~~B99 206 - 207 -First two digits is for file number 208 - 209 -For example, BN13001.00 represents file number B13, address 001, the 0th bit. 210 -))) 211 -|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7 212 -|NN|NNddddd.dd|0.0~~99255.15|((( 213 -Integer data file bit format N0~~N99 214 - 215 -First two digits is for file number 216 - 217 -For example, NN13001.00 represents file number N13, address 001, the 0th bit. 218 -))) 219 -|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2 220 -|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value) 221 -|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value) 222 -|TNS|TNSddddd|0~~99255|((( 223 -Timer Preset Value 224 - 225 -First two digits is for file number 226 - 227 -For example, TNS99255 represents file number T99, address 255. 228 -))) 229 -|TNP|TNPddddd|0~~99255|((( 230 -Timer Accumulator Value 231 - 232 -First two digits is for file number 233 - 234 -For example, TNP99255 represents file number T99, address 255. 235 -))) 236 -|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value) 237 -|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value) 238 -|CNS|CNSddddd|0~~99255|((( 239 -Counter Preset Value 240 - 241 -First two digits is for file number 242 - 243 -For example, CNS99255 represents file number C99, address 255. 244 -))) 245 -|CNP|CNPddddd|0~~99255|((( 246 -Counter Accumulator Value 247 - 248 -First two digits is for file number 249 - 250 -For example, CNP99255 represents file number C99, address 255. 251 -))) 252 -|N7|N7ddd|0~~255|Only able to communicate with file number N7 253 -|NN|NNddd|0~~99255|((( 254 -Integer data file 255 - 256 -First two digits is for file number 257 - 258 -For example, NN99255 represents file number N99, address 255. 259 -))) 260 -|(% colspan="1" rowspan="3" %)Double Word|F8|F8ddd|0~~255|((( 261 -Only able to communicate with file number N7 262 -))) 263 -|FN|FNddddd|0~~99255|((( 264 -Floating point data file 265 - 266 -First two digits is for file number 267 - 268 -For example, FN99255 represents file number F99, address 255. 269 -))) 270 -|LN|LNddddd|0~~99255|Long 271 - 272 -**3) Cable Wiring** 273 - 274 -(% style="text-align:center" %) 275 -[[image:ABRS232.gif]] 276 - 277 277 == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 278 278 279 279 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 ... ... @@ -281,7 +281,7 @@ 281 281 **1)V-BOX setting** 282 282 283 283 |**Item**|**Settings**|**Note** 284 -|Protocol|Allen-Bradley DF1 Advanced| 188 +|Protocol|Allen-Bradlley DF1 Advanced| 285 285 |Connection|RS232| 286 286 |Baud rate|19200| 287 287 |Data bit|8| ... ... @@ -1861,7 +1861,7 @@ 1861 1861 **address list** 1862 1862 1863 1863 (% class="table-bordered" %) 1864 -| =(% scope="row" %)**Type**|=**Data Type**|=**Function code and description**1768 +|**Type**|**Data Type**|**Function code and description** 1865 1865 |(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers) 1866 1866 |06 (write single register: write a binary value to a holding register) 1867 1867 |10 (write values to multiple addresses ) ... ... @@ -1901,7 +1901,7 @@ 1901 1901 1902 1902 **2)Address List** 1903 1903 1904 -| =**Type**|=**Data Type**|=**Function code & Description**1808 +|**Type**|**Register**|**Function code & Description** 1905 1905 |(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 1906 1906 |06 (write single register: write a binary value to a holding register) 1907 1907 |10 (write values to multiple addresses )
- AB.gif
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -7.3 KB - Content
- ABRS232.gif
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -7.3 KB - Content