Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 201.1
edited by Hunter
on 2023/01/15 16:36
Change comment: There is no comment for this version
To version 215.1
edited by Hunter
on 2023/03/18 15:43
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -176,8 +176,10 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 -= Create communication with **Rockwell PLC** =
180 180  
180 +
181 += Create communication with Allen-Bradley(**Rockwell**)** PLC** =
182 +
181 181  == **DF1 Advanced Protocol** ==
182 182  
183 183  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5
... ... @@ -274,8 +274,12 @@
274 274  (% style="text-align:center" %)
275 275  [[image:ABRS232.gif]]
276 276  
277 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
279 +(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %)
280 +(% id="cke_bm_5621S" style="display:none" %)** **
278 278  
282 +== **MicroLogix Protocol** ==
283 +
284 +(% class="wikigeneratedid" %)
279 279  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
280 280  
281 281  **1)V-BOX setting**
... ... @@ -520,7 +520,11 @@
520 520  
521 521  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
522 522  
529 += Create communication with **Crouzet PLC** =
523 523  
531 +== **CROUZET M3 (FBD)** ==
532 +
533 +
524 524  = Create communication with **Siemens PLC** =
525 525  
526 526  == **S7-200 Smart Ethernet Protocol** ==
... ... @@ -704,6 +704,97 @@
704 704  
705 705  [[image:image-20220824162342-2.png]]
706 706  
717 +== **LOGO Ethernet Protocol** ==
718 +
719 +Supported Series: Siemens Logo 0BA0, 0BA1 series
720 +
721 +**V-BOX Settings**
722 +
723 +
724 +|**Items**|**Settings**|**Note**
725 +|Protocol|Siemens LOGO|
726 +|Connection|Ethernet|
727 +|Port No.|102|
728 +|PLC station No.|2|
729 +
730 +**Address List**
731 +
732 +
733 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
734 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
735 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
736 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
737 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
738 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
739 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
740 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
741 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
742 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
743 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
744 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
745 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
746 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
747 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
748 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
749 +
750 +**PLC Settings in LOGO Software:**
751 +
752 +Click [Tools]~-~-[Ethernet Connections],shown as below.
753 +
754 +(% style="text-align:center" %)
755 +[[image:PIStudio.12\.PLC protocols.WebHome@12.PLC Protocol_html_8b9d2322edf89519.png]]
756 +
757 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
758 +
759 +(% style="text-align:center" %)
760 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228142937-4.png]]
761 +
762 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
763 +
764 +(% style="text-align:center" %)
765 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143047-5.png]]
766 +
767 + **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
768 +
769 +(% style="text-align:center" %)
770 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143246-6.png]]
771 +
772 +**V-BOX Communication Settings**
773 +
774 +Set PLC IP in [IP Address] settings;
775 +
776 +(% style="text-align:center" %)
777 +[[image:LldwDGntf4.png]]
778 +
779 +Enable V-BOX Ethernet in [Network];
780 +
781 +(% style="text-align:center" %)
782 +[[image:WgvjfWbQif.png]]
783 +
784 +TSAP setting
785 +
786 +* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful.
787 +
788 +{{code language="LUA"}}
789 +function init.main()
790 +addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
791 +addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
792 +end
793 +{{/code}}
794 +
795 +Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code.
796 +
797 +**✎Note:**
798 +
799 +* **Communication port configuration: **
800 +** Continuous length needs to be set to 0.
801 +** Integration interval needs to be set to 1. (no change may result in data errors)
802 +** Set Port and Device Station NO.
803 +** Other set as defaulted.
804 +* **Notes on the use of registers:**
805 +** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
806 +** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
807 +
707 707  = Create communication with **Mitsubishi PLC** =
708 708  
709 709  == **FX1S,1N,2N Serial Protocol** ==
0Il1q9GZgk.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +24.6 KB
Content
LldwDGntf4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +24.3 KB
Content
WgvjfWbQif.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +36.3 KB
Content