Changes for page 1 Communication
Last modified by xingzhi lin on 2025/08/01 15:25
From version 204.1
edited by Bob
on 2023/02/02 11:19
on 2023/02/02 11:19
Change comment:
There is no comment for this version
To version 257.1
edited by Theodore Xu
on 2023/08/23 19:31
on 2023/08/23 19:31
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 49 added, 0 removed)
- 0Il1q9GZgk.png
- 1679563870401-671.png
- 1682233464031-639.png
- CCW.Shell_E5Cwj4tUL3.png
- ControlStarCommunicate.png
- ControlStarModbus.png
- ControlStarSystemBlock.png
- CrouzetRS232 VBox.png
- Emerson.png
- Ethernet.png
- HollySysRS232.png
- Hollysys LM Modbus RTU.gif
- Hollysys485-2.png
- Hollysys485box.png
- LinfeeTerminalDiagram.png
- LldwDGntf4.png
- MeterModbusAddr.png
- MeterModbusAllView.png
- MeterModbusBaud.png
- MeterModbusPara.png
- ModbusStationSettings.png
- Monitoringtaggreenlight.png
- V-NET_Client setting.png
- V-NET_Client_ADD.png
- V-NET_Client_KOR0AHEA4M.png
- V-NET_Client_TIiAymnjkx.png
- V-NET_Client_TNBuqy7T5r.png
- V-NET_Client_communication.png
- V-NET_Client_iKKKhcgxm1.png
- V-NET_Client_t2Rg2wpSoY.png
- VNETCommunicationtabmeter.png
- VNETModbusTagByteSettings.png
- VNETModbusTagSettings.png
- WgvjfWbQif.png
- conne ab plc.png
- export.png
- export1.png
- plc 软件.png
- project create.png
- software.png
- v-net client vers.png
- wire.png
- 企业微信截图_16889606174191.png
- 盒子创建英威腾.png
- 英威腾下载.png
- 英威腾创建1.png
- 英威腾创建2.png
- 英威腾创建3.png
- 英威腾软件.png
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bob1 +XWiki.AiXia - Content
-
... ... @@ -1,6 +1,6 @@ 1 -= Create communication withWECONPLC=1 += WECON = 2 2 3 -== **LX3V Serial Protocol** ==3 +== **LX3V Serial ** == 4 4 5 5 Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 ... ... @@ -48,7 +48,7 @@ 48 48 49 49 [[image:image-20220824120524-3.png]] 50 50 51 -== **LX5V Serial Protocol** ==51 +== **LX5V Serial ** == 52 52 53 53 This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. 54 54 ... ... @@ -118,7 +118,7 @@ 118 118 119 119 The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC. 120 120 121 -== **LX5V-N Ethernet protocol** ==121 +== **LX5V-N Ethernet ** == 122 122 123 123 This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. 124 124 ... ... @@ -176,9 +176,9 @@ 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 178 178 179 -= Create communication with**RockwellPLC** =179 += Allen-Bradley(**Rockwell**) = 180 180 181 -== **DF1 Advanced Protocol** ==181 +== **DF1 Advanced Serial** == 182 182 183 183 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 184 184 ... ... @@ -274,8 +274,12 @@ 274 274 (% style="text-align:center" %) 275 275 [[image:ABRS232.gif]] 276 276 277 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 277 +(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %) 278 +(% id="cke_bm_5621S" style="display:none" %)** ** 278 278 280 +== **MicroLogix Serial** == 281 + 282 +(% class="wikigeneratedid" %) 279 279 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 280 280 281 281 **1)V-BOX setting** ... ... @@ -313,7 +313,7 @@ 313 313 314 314 [[image:image-20220824110724-1.png]] 315 315 316 -== **Micro850_FreeTag Protocol** ==320 +== **Micro850_FreeTag Ethernet** == 317 317 318 318 ((( 319 319 ((( ... ... @@ -516,20 +516,293 @@ 516 516 The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. 517 517 518 518 519 -= ** Allen-BradleyEthernetDF1** =523 +== **Micro850_FreeTag Ethernet(new)** == 520 520 525 +This example introduces the establishment of Ethernet communication between Wecon V-box and 2080-LC50-48QWB,Micro850. It is introduced through three parts: PLC software configuration, V-box software configuration. 526 + 527 +(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %) 528 +((( 529 +**Software configuration of PLC** 530 +))) 531 + 532 +(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %) 533 +((( 534 +**1)PLC programming software:Connected Components Workbench™** 535 + 536 +(% style="text-align:center" %) 537 +[[image:software.png]] 538 + 539 +**2)New PLC project** 540 + 541 +Click New Project and select the PLC model. 542 + 543 +(% style="text-align:center" %) 544 +[[image:project create.png]] 545 + 546 +**3)Set Ethernet parameters** 547 + 548 +Follow the steps below to configure Ethernet parameters 549 + 550 +PLC IP address:192.168.39.56 551 + 552 +default gateway:192.168.39.1 553 + 554 +subnet mask:255.255.255.0 555 + 556 +(% style="text-align:center" %) 557 +[[image:Ethernet.png]] 558 + 559 +**4)connect PLC** 560 + 561 +**When downloading the setting, need to change the status of the PLC to PRG** 562 + 563 +(% style="text-align:center" %) 564 +[[image:conne ab plc.png]] 565 + 566 +**V-box software configuration** 567 + 568 +**1)V-box programming software** 569 + 570 +(% style="text-align:center" %) 571 +[[image:v-net client vers.png]] 572 + 573 +**2)Set communication port parameters** 574 + 575 +In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol. 576 + 577 +(% style="text-align:center" %) 578 +[[image:V-NET_Client_t2Rg2wpSoY.png]] 579 + 580 +The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. 581 + 582 +(% style="text-align:center" %) 583 +[[image:V-NET_Client_communication.png]] 584 + 585 +Export variables from PLC, select CSV file, comma delimited.(% id="cke_bm_1950S" style="display:none" %) 586 + 587 +(% style="text-align:center" %) 588 +[[image:export1.png]] 589 + 590 +(% style="text-align:center" %) 591 +[[image:CCW.Shell_E5Cwj4tUL3.png]] 592 + 593 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png"]]icon add label. 594 + 595 +(% style="text-align:center" %) 596 +[[image:V-NET_Client_TNBuqy7T5r.png]] 597 + 598 +**3)Engineering production** 599 + 600 +According to your own needs, use the V-NET client software to edit the required data monitoring points. 601 + 602 +(% style="text-align:center" %) 603 +[[image:V-NET_Client_KOR0AHEA4M.png]] 604 + 605 + 606 +))) 607 + 608 +== **Ethernet DF1 Protocol** == 609 + 521 521 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 522 522 612 += Create communication with **Crouzet PLC** = 523 523 524 -= C reatecommunicationwith**SiemensPLC**=614 +== **CROUZET M3 (FBD)** == 525 525 526 - == **S7-200 SmartEthernet Protocol**==616 +Support Series: Crouzet Millenium 3 CD12/CB12 527 527 528 - [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]618 +**1)V-BOX setting** 529 529 620 +|=Item|=Recommended |=Note 621 +|=Protocol|CROUZET M3 (FBD)| 622 +|=Connection|RS232| 623 +|=Baud rate|115200| 624 +|=Stop bits|1| 625 +|=Data bits|7| 626 +|=Parity|EVEN| 530 530 531 - ==**S7-300 EthernetProtocol**==628 +**2)Address List** 532 532 630 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note 631 +|(% rowspan="4" %)Bit|I|I DD|1~~99|Input 632 +|SLIBit|SLIBit DD.dd|1.0~~24.15|Serial Link Input 633 +|SLOBit|SLOBit DD.dd|25.0~~48.15|Serial Link Output(Read only) 634 +|State|State D|1~~1|PLC state(Read only) 635 +|(% rowspan="5" %)Word|AI|AI DD|1~~99|Analog Input 636 +|SLIn|SLIn DD|1~~24|Serial Link Input 637 +|SLOut|SLOut DD|25~~48|Serial Link Output(Read only) 638 +|Time|Time D|1~~6|((( 639 +Time1: Second 640 + 641 +Time2: Minute 642 + 643 +Time3: Hour 644 + 645 +Time4: Day 646 + 647 +Time5: Month 648 + 649 +Time6: Year 650 +))) 651 +|Order|Order D|1~~1|((( 652 +Running command(Write only) 653 + 654 +~=2: Run mode; =1: Stop mode; 655 +))) 656 + 657 +**3)Cable Wiring** 658 + 659 +(% style="text-align:center" %) 660 +[[image:CrouzetRS232 VBox.png]] 661 + 662 +{{info}} 663 +**✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details. 664 +{{/info}} 665 + 666 += EMERSON = 667 + 668 += **RTU Slave ** = 669 + 670 +Supported series: EC10 series 671 + 672 +**1)V-BOX setting** 673 + 674 +|**Items**|**Settings**|**Note** 675 +|Protocol|Emerson 984 RTU Slave MODBUS| 676 +|Connection|RS485| 677 +|Baud rate|19200| 678 +|Data bit|8| 679 +|Parity|EVEN| 680 +|Stop bit|1| 681 +|Device station No.|1|Need to be same as the PLC setting 682 + 683 +(% class="wikigeneratedid" %) 684 +**2)PLC Setting** 685 + 686 +(% class="wikigeneratedid" %) 687 +Remember to use the Control Star to enable the Modbus RTU communication for port 1 in system block before dowload into PLC. 688 + 689 +(% style="text-align:center" %) 690 +[[image:ControlStarSystemBlock.png]] 691 + 692 +(% style="text-align:center" %) 693 +[[image:ControlStarCommunicate.png]] 694 + 695 +(% style="text-align:center" %) 696 +[[image:ControlStarModbus.png]] 697 + 698 +(% class="wikigeneratedid" %) 699 +**3)Address List** 700 + 701 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 702 +|(% colspan="1" rowspan="12" %)Bit|Y|YOOO|0~~377| 703 +|X|XOOO|0~~377| 704 +|M0|M0DDDD|0~~2047| 705 +|M1|M1DDDDD|2048~~10239| 706 +|SM0|SM0DDD|0~~255| 707 +|SM1|SM1DDD|256~~511| 708 +|S0|S0DDDD|0~~1023| 709 +|S1|S1DDDD|1024~~4095| 710 +|T0|T0DDD|0~~255| 711 +|T1|T1DDD|256~~511| 712 +|C0|C0DDD|0~~255| 713 +|C1|C1DDD|256~~306| 714 +|(% colspan="1" rowspan="7" %)Word|D|DDDDD|0~~7999| 715 +|Z|ZDD|0~~15| 716 +|TW0|TW0DDD|0~~255| 717 +|TW1|TW1DDD|256~~511| 718 +|SD0|SD0DDD|0~~255| 719 +|SD1|SD1DDD|256~~511| 720 +|CW|CWDDD|0~~306| 721 +|(% colspan="1" rowspan="2" %)Double Word|CW0|CW0DDD|200~~255| 722 +|CW1|CW1DDDDD|256~~99999| 723 + 724 +**4) Cable Wiring** 725 + 726 +(% style="text-align:center" %) 727 +[[image:Emerson.png]] 728 + 729 += HollySys PLC = 730 + 731 +== **LK Modbus RTU ** == 732 + 733 +Supported Series: HollySys LK series PLC 734 + 735 +**1)V-BOX setting** 736 + 737 +|**Items**|**Settings**|**Note** 738 +|Protocol|HollySys LK Modbus RTU| 739 +|Connection|RS485| 740 +|Baud rate|38400| 741 +|Data bit|8| 742 +|Parity|None| 743 +|Stop bit|1| 744 +|Device station No.|1| 745 + 746 +**2)Address List** 747 + 748 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** 749 +|Bit|QX|QXDDDDD.dd|0~~65535.15| 750 +|Bit|IX|IXDDDDD.dd|0~~65535.15| 751 +|Bit|MX|MXDDDDD.dd|0~~65535.15| 752 +|Word|QW|QWDDDDD|0~~99999| 753 +|Word|IW|IWDDDDD|0~~99999| 754 +|Word|MW|MWDDDDD|0~~99999| 755 +|Word|MD|MDDDDDD|0~~99999| 756 + 757 +**3)Cable Wiring** 758 + 759 +(% style="text-align:center" %) 760 +[[image:Hollysys485-2.png]] 761 + 762 +== **LM Modbus RTU** == 763 + 764 +(% class="wikigeneratedid" %) 765 +Supported Series: HollySys LM3109/LM3107 PLC 766 + 767 +(% class="wikigeneratedid" %) 768 +**1)V-BOX setting** 769 + 770 +|(% style="width:208px" %)**Items**|(% style="width:310px" %)**Settings**|(% style="width:365px" %)**Optional**|(% style="width:152px" %)**Note** 771 +|(% style="width:208px" %)Protocol|(% style="width:310px" %)HollySys LM Modbus RTU|(% style="width:365px" %)HollySys LM Modbus RTU|(% style="width:152px" %) 772 +|(% style="width:208px" %)Connection|(% style="width:310px" %)RS232|(% style="width:365px" %)RS485|(% style="width:152px" %) 773 +|(% style="width:208px" %)Baud rate|(% style="width:310px" %)38400|(% style="width:365px" %)38400|(% style="width:152px" %) 774 +|(% style="width:208px" %)Data bit|(% style="width:310px" %)8|(% style="width:365px" %)8|(% style="width:152px" %) 775 +|(% style="width:208px" %)Parity|(% style="width:310px" %)None|(% style="width:365px" %)None|(% style="width:152px" %) 776 +|(% style="width:208px" %)Stop bit|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %) 777 +|(% style="width:208px" %)Device station No.|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %) 778 + 779 +**2)Address List** 780 + 781 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** 782 +|Bit|QX|QXDDDDD.o|0~~99999.7| 783 +|Bit|IX|IXDDDDD.o|0~~99999.7| 784 +|Bit|MX|MXDDDDD.o|0~~99999.7| 785 +|Word|QW|QWDDDDD|0~~99999| 786 +|Word|IW|IWDDDDD|0~~99999| 787 +|Word|MW|MWDDDDD|0~~99999| 788 +|Word|MD|MDDDDDD|0~~99999| 789 + 790 +**Cable Wiring** 791 + 792 +RS232 793 + 794 +(% style="text-align:center" %) 795 +[[image:HollySysRS232.png]] 796 + 797 +RS485 798 + 799 +(% style="text-align:center" %) 800 +[[image:Hollysys LM Modbus RTU.gif]] 801 + 802 += **Siemens ** = 803 + 804 +== **S7-200 Smart Ethernet ** == 805 + 806 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 807 + 808 +== **S7-300 Ethernet ** == 809 + 533 533 Supported Series: Siemens S7-300 series PLC 534 534 535 535 **1)V-BOX setting** ... ... @@ -586,11 +586,11 @@ 586 586 ))) 587 587 ))) 588 588 589 -== **S7-1200 Ethernet Protocol** ==866 +== **S7-1200 Ethernet ** == 590 590 591 591 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 592 592 593 -== **S7-XXX Ethernet Protocol** ==870 +== **S7-XXX Ethernet l** == 594 594 595 595 Supported Series: Siemens S7-400, S7-1200 and S7-1500 596 596 ... ... @@ -704,12 +704,101 @@ 704 704 705 705 [[image:image-20220824162342-2.png]] 706 706 707 -== **LOGO Ethernet Protocol** ==984 +== **LOGO Ethernet ** == 708 708 709 - = Createcommunicationwith**Mitsubishi PLC** =986 +Supported Series: Siemens Logo 0BA0, 0BA1 series 710 710 711 - ==**FX1S,1N,2NSerial Protocol**==988 +**V-BOX Settings** 712 712 990 + 991 +|**Items**|**Settings**|**Note** 992 +|Protocol|Siemens LOGO| 993 +|Connection|Ethernet| 994 +|Port No.|102| 995 +|PLC station No.|2| 996 + 997 +**Address List** 998 + 999 + 1000 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address** 1001 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0 1002 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000 1003 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000 1004 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000 1005 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0 1006 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770 1007 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0 1008 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180 1009 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040 1010 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000 1011 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140 1012 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280 1013 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0 1014 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70 1015 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000 1016 + 1017 +**PLC Settings in LOGO Software:** 1018 + 1019 +Click [Tools]~-~-[Ethernet Connections],shown as below. 1020 + 1021 +(% style="text-align:center" %) 1022 +[[image:PIStudio.12\.PLC protocols.WebHome@12.PLC Protocol_html_8b9d2322edf89519.png]] 1023 + 1024 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 1025 + 1026 +(% style="text-align:center" %) 1027 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228142937-4.png]] 1028 + 1029 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 1030 + 1031 +(% style="text-align:center" %) 1032 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143047-5.png]] 1033 + 1034 + **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 1035 + 1036 +(% style="text-align:center" %) 1037 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143246-6.png]] 1038 + 1039 +**V-BOX Communication Settings** 1040 + 1041 +Set PLC IP in [IP Address] settings; 1042 + 1043 +(% style="text-align:center" %) 1044 +[[image:LldwDGntf4.png]] 1045 + 1046 +Enable V-BOX Ethernet in [Network]; 1047 + 1048 +(% style="text-align:center" %) 1049 +[[image:WgvjfWbQif.png]] 1050 + 1051 +TSAP setting 1052 + 1053 +* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful. 1054 + 1055 +{{code language="LUA"}} 1056 +function init.main() 1057 +addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address 1058 +addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address 1059 +end 1060 +{{/code}} 1061 + 1062 +Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 1063 + 1064 +**✎Note:** 1065 + 1066 +* **Communication port configuration: ** 1067 +** Continuous length needs to be set to 0. 1068 +** Integration interval needs to be set to 1. (no change may result in data errors) 1069 +** Set Port and Device Station NO. 1070 +** Other set as defaulted. 1071 +* **Notes on the use of registers:** 1072 +** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc. 1073 +** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 ) 1074 + 1075 += **Mitsubishi ** = 1076 + 1077 +== **FX1S,1N,2N Serial ** == 1078 + 713 713 Supported Series: Mitsubishi FX1S, FX1N, FX2N series 714 714 715 715 **1)V-BOX Settings** ... ... @@ -755,7 +755,7 @@ 755 755 [[image:image-20220825100845-4.png]] 756 756 757 757 758 -== **FX3U,3G,3GA Serial Protocol** ==1124 +== **FX3U,3G,3GA Serial ** == 759 759 760 760 Supported Series: Mitsubishi FX3U, FX3G, FX3GA series 761 761 ... ... @@ -802,7 +802,7 @@ 802 802 [[image:image-20220825100845-4.png]] 803 803 804 804 805 -== **FX3U Ethernet Protocol** ==1171 +== **FX3U Ethernet ** == 806 806 807 807 Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L 808 808 ... ... @@ -897,7 +897,7 @@ 897 897 898 898 [[image:image-20221119101946-2.png||height="395" width="695"]] 899 899 900 -== **FX5U Serial Protocol** ==1266 +== **FX5U Serial ** == 901 901 902 902 Mitsubishi FX5U series PLC 903 903 ... ... @@ -979,7 +979,7 @@ 979 979 980 980 [[image:image-20220825105533-3.png]] 981 981 982 -== **FX5U Ethernet Protocol** ==1348 +== **FX5U Ethernet ** == 983 983 984 984 Mitsubishi FX5U series PLC 985 985 ... ... @@ -1055,7 +1055,7 @@ 1055 1055 1056 1056 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1057 1057 1058 -== **L02 Serial Protocol** ==1424 +== **L02 Serial ** == 1059 1059 1060 1060 Mitsubishi L02 series CPU built-in serial port. 1061 1061 ... ... @@ -1115,7 +1115,7 @@ 1115 1115 1116 1116 [[image:image-20220825160820-4.png]] 1117 1117 1118 -== **L02 Ethernet Protocol** ==1484 +== **L02 Ethernet ** == 1119 1119 1120 1120 Mitsubishi L series CPU built-in Ethernet port. 1121 1121 ... ... @@ -1188,13 +1188,13 @@ 1188 1188 1189 1189 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1190 1190 1191 -== **Q12H Serial Protocol** ==1557 +== **Q12H Serial ** == 1192 1192 1193 1193 This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol 1194 1194 1195 1195 [[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]] 1196 1196 1197 -== **QJ71E71 Ethernet Protocol** ==1563 +== **QJ71E71 Ethernet ** == 1198 1198 1199 1199 Mitsubishi QJ71E71 Ethernet communication module; 1200 1200 ... ... @@ -1269,9 +1269,9 @@ 1269 1269 1270 1270 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]] 1271 1271 1272 -= Create communication with**DeltaPLC** =1638 += **Delta** = 1273 1273 1274 -== **DVP Ethernet Protocol** ==1640 +== **DVP Ethernet** == 1275 1275 1276 1276 Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module 1277 1277 ... ... @@ -1336,7 +1336,7 @@ 1336 1336 (% style="text-align:center" %) 1337 1337 [[image:DVPEthernetVNETPortocol.png]] 1338 1338 1339 -== **DVP serial protocol** ==1705 +== **DVP serial** == 1340 1340 1341 1341 Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX 1342 1342 ... ... @@ -1372,7 +1372,7 @@ 1372 1372 (% style="text-align:center" %) 1373 1373 [[image:Delta DVP PROTOCOLSerial232.png]] 1374 1374 1375 -== **AS Ethernet Protocol** ==1741 +== **AS Ethernet** == 1376 1376 1377 1377 **1)V-BOX Settings** 1378 1378 ... ... @@ -1417,19 +1417,18 @@ 1417 1417 1418 1418 [[image:image-20220831155157-3.png]] 1419 1419 1420 -= Create communication with**OmronPLC** =1786 += **Omron** = 1421 1421 1422 -== **CP1 Series Protocol** ==1788 +== **CP1 Series** == 1423 1423 1424 -[[ 下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]1790 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 1425 1425 1426 -== **CP2M Series Protocol** ==1792 +== **CP2M Series** == 1427 1427 1428 -[[ 下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]1794 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 1429 1429 1796 +== **EC55 Series ** == 1430 1430 1431 -== **EC55 Series Protocol** == 1432 - 1433 1433 Supported device: EC55 temperature instrument 1434 1434 1435 1435 **1)V-BOX Settings** ... ... @@ -1489,9 +1489,9 @@ 1489 1489 * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests. 1490 1490 * [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written. 1491 1491 1492 -= Create communication withXinje** PLC**=1857 += Xinje = 1493 1493 1494 -== **XC serial protocol** ==1859 +== **XC serial** == 1495 1495 1496 1496 **1)V-BOX Settings** 1497 1497 ... ... @@ -1533,7 +1533,7 @@ 1533 1533 1534 1534 [[image:image-20220831163441-4.png]] 1535 1535 1536 -== **XD serial protocol** ==1901 +== **XD serial** == 1537 1537 1538 1538 **1)V-BOX Settings** 1539 1539 ... ... @@ -1607,7 +1607,7 @@ 1607 1607 1608 1608 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]] 1609 1609 1610 -= Create communication with**SchneiderPLC** =1975 += **Schneider** = 1611 1611 1612 1612 == **Schneider MODBUS RTU** == 1613 1613 ... ... @@ -1641,7 +1641,7 @@ 1641 1641 1642 1642 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]] 1643 1643 1644 -= Create communication withInovance** PLC**=2009 += Inovance = 1645 1645 1646 1646 == **H3U serial protocol** == 1647 1647 ... ... @@ -1693,9 +1693,9 @@ 1693 1693 1694 1694 [[image:image-20220831164731-4.png]] 1695 1695 1696 -= Create communication withPanasonic** PLC**=2061 += Panasonic = 1697 1697 1698 -== **FP serial protocol** ==2063 +== **FP serial** == 1699 1699 1700 1700 **1)V-BOX Settings** 1701 1701 ... ... @@ -1743,9 +1743,9 @@ 1743 1743 1744 1744 [[image:image-20220831165008-1.png]] 1745 1745 1746 -= Create communication withLS** PLC**=2111 += LS = 1747 1747 1748 -== **XBC serial protocol** ==2113 +== **XBC serial** == 1749 1749 1750 1750 **1)V-BOX Settings** 1751 1751 ... ... @@ -1797,7 +1797,7 @@ 1797 1797 1798 1798 [[image:image-20220831170215-2.png]] 1799 1799 1800 -== **XGK FEnet Ethernet protocol** ==2165 +== **XGK FEnet Ethernet** == 1801 1801 1802 1802 Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 1803 1803 ... ... @@ -1840,8 +1840,76 @@ 1840 1840 1841 1841 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1842 1842 1843 -= Createcommunication with **Modbus **=2208 += INVT = 1844 1844 2210 +**1)V-BOX setting** 2211 + 2212 +|**Item**|**Settings**|**Note** 2213 +|Protocol|INVT_IVC2L| 2214 +|Connection|RS232| 2215 +|Baud rate|19200| 2216 +|Data bit|8| 2217 +|Parity|EVEN| 2218 +|Stop bit|1| 2219 +|PLC station No.|1 2220 + 2221 +**2)Address List** 2222 + 2223 + 2224 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 2225 +|(% colspan="1" rowspan="7" %)Bit|X|XOOO|0~~377| 2226 +|Y|YOOO|0~~377| 2227 +|M|MDDDD|0~~1999| 2228 +|SM|SMDDD|0~~255| 2229 +|S|SDDD|0~~991| 2230 +|T|TDDD|0~~255| 2231 +|C|CDDD|0~~255| 2232 +|(% rowspan="5" %)Word|D|DDDDD|0~~7999| 2233 +|SD|SDDDD|0~~255| 2234 +|Z|ZDD|0~~15| 2235 +|T|TDDD|0~~255| 2236 +|C|CDDD|0~~199| 2237 +|Double word|C|CDDD|200~~255| 2238 + 2239 +**3)Communication Settings** 2240 + 2241 +(% style="text-align:center" %) 2242 +[[image:盒子创建英威腾.png]] 2243 + 2244 +**4)PLC software** 2245 + 2246 +(% style="text-align:center" %) 2247 +[[image:英威腾软件.png]] 2248 + 2249 +**5)PLC setting ** 2250 + 2251 +Open the INVI plc software, create a new project or open a project that has already been created 2252 + 2253 +(% style="text-align:center" %) 2254 +[[image:英威腾创建1.png]] 2255 + 2256 +Configure serial port parameters. 2257 + 2258 +(% style="text-align:center" %) 2259 +[[image:英威腾创建2.png]] 2260 + 2261 +PC connect PLC 2262 + 2263 +(% style="text-align:center" %) 2264 +[[image:英威腾创建3.png]] 2265 + 2266 +Download 2267 + 2268 +(% style="text-align:center" %) 2269 +[[image:英威腾下载.png]] 2270 + 2271 +**6)Cable Wiring** 2272 + 2273 +(% style="text-align:center" %) 2274 +[[image:wire.png]] 2275 + 2276 += **Modbus ** = 2277 + 1845 1845 == **MODBUS RTU Slave (All function)** == 1846 1846 1847 1847 Select the protocol "Modbus RTU Slave (All Fuction)", ... ... @@ -1851,6 +1851,86 @@ 1851 1851 (% style="text-align:center" %) 1852 1852 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 1853 1853 2287 +== **Modbus Meter** == 2288 + 2289 +The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication. 2290 + 2291 +~1. Wiring the RS485 cable first. Because the pin 58 is A, the pin 59 is B for meter. Here we use the COM1 to connect. So the diagram like follows: 2292 + 2293 +(% style="text-align:center" %) 2294 +[[image:LinfeeTerminalDiagram.png]] 2295 + 2296 +2. Check the specific Modbus parameter in the communication menu from LED display. 2297 + 2298 +So from the following pictures, we can know the Meter Address is 85, Baud rate is 9600, CRC None. 2299 + 2300 +{{info}} 2301 +**✎Note: **Meter address usually corresponding to the Modbus Slave Station No. on the Modbus communication. 2302 +{{/info}} 2303 + 2304 +(% style="text-align:center" %) 2305 +[[image:MeterModbusAllView.png]] 2306 + 2307 +(% class="wikigeneratedid" %) 2308 +3. Set up the communication in the Configuration tab. 2309 + 2310 +(% class="wikigeneratedid" %) 2311 +Select the protocol as **ModBus RTU Slave (All Function)**. And set the communication parameters like below. 2312 + 2313 +(% style="text-align:center" %) 2314 +[[image:VNETCommunicationtabmeter.png]] 2315 + 2316 +(% class="wikigeneratedid" %) 2317 +4. Create new real-time monitoring tag accroding to Modbus manual 2318 + 2319 +(% class="wikigeneratedid" %) 2320 +Enter the address we want to read from the meter. The following table is intercept part of the manual for Linfee Modbus manual. 2321 + 2322 +(% class="wikigeneratedid" %) 2323 +**0x03/0x04 command data register address**: 2324 + 2325 +(% style="width:1142.22px" %) 2326 +|(% style="display:none" %) |=(% colspan="2" rowspan="1" style="width: 165px;" %)Address(% style="display:none" %) |=Description|=Data Format|=(% style="width: 254px;" %)Data Length(Word)|=(% style="width: 282px;" %)Remark 2327 +|(%%)(% style="display:none" %) (%%) HEX|(% style="width:107px" %)DEC|(%%)(% style="display:none" %) (%%) |(% style="width:100px" %) |(%%)(% style="display:none" %) (%%) |(% style="width:318px" %) 2328 +|(% style="width:107px" %)0x00|(% style="width:100px" %)0|Reserved| | |(% style="width:318px" %) 2329 +|(% style="width:107px" %)0x02|(% style="width:100px" %)2|Reserved| | |(% style="width:318px" %) 2330 +|(% style="width:107px" %)0x04|(% style="width:100px" %)4|Reserved| | |(% style="width:318px" %) 2331 +|(% style="width:107px" %)0x06|(% style="width:100px" %)6|Ua|float|2|(% style="width:318px" %)Phase Voltage data, Unit V 2332 +|(% style="width:107px" %)0x08|(% style="width:100px" %)8|Ub|float|2|(% style="width:318px" %)Phase Voltage data, Unit V 2333 +|(% style="width:107px" %)0x0A|(% style="width:100px" %)10|Uc|float|2|(% style="width:318px" %)Phase Voltage data, Unit V 2334 +|(% style="width:107px" %)0x0C|(% style="width:100px" %)12|Uab|float|2|(% style="width:318px" %)Line Voltage data, Unit V 2335 +|(% style="width:107px" %)0x0E|(% style="width:100px" %)14|Ubc|float|2|(% style="width:318px" %)Line Voltage data, Unit V 2336 +|(% style="width:107px" %)0x10|(% style="width:100px" %)16|Uca|float|2|(% style="width:318px" %)Line Voltage data, Unit V 2337 +|(% style="width:107px" %)0x12|(% style="width:100px" %)18|Ia|float|2|(% style="width:318px" %)Phase Current data, Unit A 2338 +|(% style="width:107px" %)0x14|(% style="width:100px" %)20|Ib|float|2|(% style="width:318px" %)Phase Current data, Unit A 2339 +|(% style="width:107px" %)0x16|(% style="width:100px" %)22|Ic|float|2|(% style="width:318px" %)Phase Current data, Unit A 2340 + 2341 +{{info}} 2342 +**✎Note: **We usually use the Data Type 4 for read the Modbus registers(Function Code 03) 2343 +{{/info}} 2344 + 2345 +For example, here we want to read the Phase Voltage Ua (Modbus offset 0006), the Modbus register main No. requires input decimal number, and check whether the actual address has one address offset, so the tag configured like the following screenshot: 2346 + 2347 +(% style="text-align:center" %) 2348 +[[image:VNETModbusTagSettings.png]] 2349 + 2350 +(% style="text-align:center" %) 2351 +[[image:VNETModbusTagByteSettings.png]] 2352 + 2353 +{{info}} 2354 +**✎Note: **If the read value is incorrect, please check whether need to change the Byte order. 2355 +{{/info}} 2356 + 2357 +Set the Modbus Slave Station No. 2358 + 2359 +(% style="text-align:center" %) 2360 +[[image:ModbusStationSettings.png]] 2361 + 2362 +If the communication is setup successfully, the tag will show green light. 2363 + 2364 +(% style="text-align:center" %) 2365 +[[image:Monitoringtaggreenlight.png]] 2366 + 1854 1854 == **MODBUS RTU Master** == 1855 1855 1856 1856 Select the protocol "Modbus RTU Master",
- 0Il1q9GZgk.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.6 KB - Content
- 1679563870401-671.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +39.3 KB - Content
- 1682233464031-639.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.9 KB - Content
- CCW.Shell_E5Cwj4tUL3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.1 KB - Content
- ControlStarCommunicate.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.0 KB - Content
- ControlStarModbus.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content
- ControlStarSystemBlock.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.3 KB - Content
- CrouzetRS232 VBox.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.9 KB - Content
- Emerson.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- Ethernet.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +45.5 KB - Content
- HollySysRS232.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.4 KB - Content
- Hollysys LM Modbus RTU.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.1 KB - Content
- Hollysys485-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.5 KB - Content
- Hollysys485box.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.4 KB - Content
- LinfeeTerminalDiagram.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.6 KB - Content
- LldwDGntf4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.3 KB - Content
- MeterModbusAddr.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +562.5 KB - Content
- MeterModbusAllView.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.6 MB - Content
- MeterModbusBaud.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +444.0 KB - Content
- MeterModbusPara.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +532.0 KB - Content
- ModbusStationSettings.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.8 KB - Content
- Monitoringtaggreenlight.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.5 KB - Content
- V-NET_Client setting.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +41.9 KB - Content
- V-NET_Client_ADD.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.4 KB - Content
- V-NET_Client_KOR0AHEA4M.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.2 KB - Content
- V-NET_Client_TIiAymnjkx.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.8 KB - Content
- V-NET_Client_TNBuqy7T5r.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.7 KB - Content
- V-NET_Client_communication.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +25.5 KB - Content
- V-NET_Client_iKKKhcgxm1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.9 KB - Content
- V-NET_Client_t2Rg2wpSoY.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +53.7 KB - Content
- VNETCommunicationtabmeter.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.0 KB - Content
- VNETModbusTagByteSettings.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.2 KB - Content
- VNETModbusTagSettings.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.7 KB - Content
- WgvjfWbQif.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.3 KB - Content
- conne ab plc.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.1 KB - Content
- export.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +115.2 KB - Content
- export1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +115.2 KB - Content
- plc 软件.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +106.8 KB - Content
- project create.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.5 KB - Content
- software.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +25.8 KB - Content
- v-net client vers.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.1 KB - Content
- wire.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +137.2 KB - Content
- 企业微信截图_16889606174191.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.7 KB - Content
- 盒子创建英威腾.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +86.5 KB - Content
- 英威腾下载.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +49.0 KB - Content
- 英威腾创建1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.7 KB - Content
- 英威腾创建2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +115.7 KB - Content
- 英威腾创建3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.6 KB - Content
- 英威腾软件.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.6 KB - Content