Changes for page 1 Communication

Last modified by xingzhi lin on 2025/08/01 15:25

From version 204.1
edited by Bob
on 2023/02/02 11:19
Change comment: There is no comment for this version
To version 258.1
edited by Theodore Xu
on 2023/08/23 19:34
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bob
1 +XWiki.AiXia
Content
... ... @@ -1,6 +1,6 @@
1 -= Create communication with WECON PLC =
1 += WECON =
2 2  
3 -== **LX3V Serial Protocol** ==
3 +== **LX3V Serial ** ==
4 4  
5 5  Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
... ... @@ -48,7 +48,7 @@
48 48  
49 49   [[image:image-20220824120524-3.png]]
50 50  
51 -== **LX5V Serial Protocol** ==
51 +== **LX5V Serial ** ==
52 52  
53 53  This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
54 54  
... ... @@ -118,7 +118,7 @@
118 118  
119 119  The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC.
120 120  
121 -== **LX5V-N Ethernet protocol** ==
121 +== **LX5V-N Ethernet ** ==
122 122  
123 123  This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
124 124  
... ... @@ -176,9 +176,9 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 -= Create communication with **Rockwell PLC** =
179 += Allen-Bradley(**Rockwell**) =
180 180  
181 -== **DF1 Advanced Protocol** ==
181 +== **DF1 Advanced  Serial** ==
182 182  
183 183  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5
184 184  
... ... @@ -274,8 +274,12 @@
274 274  (% style="text-align:center" %)
275 275  [[image:ABRS232.gif]]
276 276  
277 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
277 +(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %)
278 +(% id="cke_bm_5621S" style="display:none" %)** **
278 278  
280 +== **MicroLogix Serial** ==
281 +
282 +(% class="wikigeneratedid" %)
279 279  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
280 280  
281 281  **1)V-BOX setting**
... ... @@ -313,7 +313,7 @@
313 313  
314 314  [[image:image-20220824110724-1.png]]
315 315  
316 -== **Micro850_FreeTag Protocol** ==
320 +== **Micro850_FreeTag Ethernet** ==
317 317  
318 318  (((
319 319  (((
... ... @@ -516,20 +516,293 @@
516 516  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
517 517  
518 518  
519 -= **Allen-Bradley Ethernet DF1** =
523 +== **Micro850_FreeTag Ethernet(new)** ==
520 520  
525 +This example introduces the establishment of Ethernet communication between Wecon V-box and 2080-LC50-48QWB,Micro850. It is introduced through three parts: PLC software configuration, V-box software configuration.
526 +
527 +(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
528 +(((
529 +**Software configuration of PLC**
530 +)))
531 +
532 +(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %)
533 +(((
534 +**1)PLC programming software:Connected Components Workbench™**
535 +
536 +(% style="text-align:center" %)
537 +[[image:software.png]]
538 +
539 +**2)New PLC project**
540 +
541 +Click New Project and select the PLC model.
542 +
543 +(% style="text-align:center" %)
544 +[[image:project create.png]]
545 +
546 +**3)Set Ethernet parameters**
547 +
548 +Follow the steps below to configure Ethernet parameters
549 +
550 +PLC IP address:192.168.39.56
551 +
552 +default gateway:192.168.39.1
553 +
554 +subnet mask:255.255.255.0
555 +
556 +(% style="text-align:center" %)
557 +[[image:Ethernet.png]]
558 +
559 +**4)connect PLC**
560 +
561 +**When downloading the setting, need to change the status of the PLC to PRG**
562 +
563 +(% style="text-align:center" %)
564 +[[image:conne ab plc.png]]
565 +
566 +**V-box software configuration**
567 +
568 +**1)V-box programming software**
569 +
570 +(% style="text-align:center" %)
571 +[[image:v-net client vers.png]]
572 +
573 +**2)Set communication port parameters**
574 +
575 +In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
576 +
577 +(% style="text-align:center" %)
578 +[[image:V-NET_Client_t2Rg2wpSoY.png]]
579 +
580 +The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
581 +
582 +(% style="text-align:center" %)
583 +[[image:V-NET_Client_communication.png]]
584 +
585 +Export variables from PLC, select CSV file, comma delimited.(% id="cke_bm_1950S" style="display:none" %)
586 +
587 +(% style="text-align:center" %)
588 +[[image:export1.png]]
589 +
590 +(% style="text-align:center" %)
591 +[[image:CCW.Shell_E5Cwj4tUL3.png]]
592 +
593 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png"]]icon add label.
594 +
595 +(% style="text-align:center" %)
596 +[[image:V-NET_Client_TNBuqy7T5r.png]]
597 +
598 +**3)Engineering production**
599 +
600 +According to your own needs, use the V-NET client software to edit the required data monitoring points.
601 +
602 +(% style="text-align:center" %)
603 +[[image:V-NET_Client_KOR0AHEA4M.png]]
604 +
605 +
606 +)))
607 +
608 +== **Ethernet DF1** ==
609 +
521 521  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
522 522  
612 += **Crouzet PLC** =
523 523  
524 -= Create communication with **Siemens PLC** =
614 +== **CROUZET M3 (FBD) Serial** ==
525 525  
526 -== **S7-200 Smart Ethernet Protocol** ==
616 +Support Series: Crouzet Millenium 3 CD12/CB12
527 527  
528 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
618 +**1)V-BOX setting**
529 529  
620 +|=Item|=Recommended |=Note
621 +|=Protocol|CROUZET M3 (FBD)|
622 +|=Connection|RS232|
623 +|=Baud rate|115200|
624 +|=Stop bits|1|
625 +|=Data bits|7|
626 +|=Parity|EVEN|
530 530  
531 -== **S7-300 Ethernet Protocol** ==
628 +**2)Address List**
532 532  
630 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note
631 +|(% rowspan="4" %)Bit|I|I DD|1~~99|Input
632 +|SLIBit|SLIBit DD.dd|1.0~~24.15|Serial Link Input
633 +|SLOBit|SLOBit DD.dd|25.0~~48.15|Serial Link Output(Read only)
634 +|State|State D|1~~1|PLC state(Read only)
635 +|(% rowspan="5" %)Word|AI|AI DD|1~~99|Analog Input
636 +|SLIn|SLIn DD|1~~24|Serial Link Input
637 +|SLOut|SLOut DD|25~~48|Serial Link Output(Read only)
638 +|Time|Time D|1~~6|(((
639 +Time1: Second
640 +
641 +Time2: Minute
642 +
643 +Time3: Hour
644 +
645 +Time4: Day
646 +
647 +Time5: Month
648 +
649 +Time6: Year
650 +)))
651 +|Order|Order D|1~~1|(((
652 +Running command(Write only)
653 +
654 +~=2: Run mode; =1: Stop mode;
655 +)))
656 +
657 +**3)Cable Wiring**
658 +
659 +(% style="text-align:center" %)
660 +[[image:CrouzetRS232 VBox.png]]
661 +
662 +{{info}}
663 +**✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details.
664 +{{/info}}
665 +
666 += EMERSON =
667 +
668 += **RTU Slave ** =
669 +
670 +Supported series: EC10 series
671 +
672 +**1)V-BOX setting**
673 +
674 +|**Items**|**Settings**|**Note**
675 +|Protocol|Emerson 984 RTU Slave MODBUS|
676 +|Connection|RS485|
677 +|Baud rate|19200|
678 +|Data bit|8|
679 +|Parity|EVEN|
680 +|Stop bit|1|
681 +|Device station No.|1|Need to be same as the PLC setting
682 +
683 +(% class="wikigeneratedid" %)
684 +**2)PLC Setting**
685 +
686 +(% class="wikigeneratedid" %)
687 +Remember to use the Control Star to enable the Modbus RTU communication for port 1 in system block before dowload into PLC.
688 +
689 +(% style="text-align:center" %)
690 +[[image:ControlStarSystemBlock.png]]
691 +
692 +(% style="text-align:center" %)
693 +[[image:ControlStarCommunicate.png]]
694 +
695 +(% style="text-align:center" %)
696 +[[image:ControlStarModbus.png]]
697 +
698 +(% class="wikigeneratedid" %)
699 +**3)Address List**
700 +
701 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
702 +|(% colspan="1" rowspan="12" %)Bit|Y|YOOO|0~~377|
703 +|X|XOOO|0~~377|
704 +|M0|M0DDDD|0~~2047|
705 +|M1|M1DDDDD|2048~~10239|
706 +|SM0|SM0DDD|0~~255|
707 +|SM1|SM1DDD|256~~511|
708 +|S0|S0DDDD|0~~1023|
709 +|S1|S1DDDD|1024~~4095|
710 +|T0|T0DDD|0~~255|
711 +|T1|T1DDD|256~~511|
712 +|C0|C0DDD|0~~255|
713 +|C1|C1DDD|256~~306|
714 +|(% colspan="1" rowspan="7" %)Word|D|DDDDD|0~~7999|
715 +|Z|ZDD|0~~15|
716 +|TW0|TW0DDD|0~~255|
717 +|TW1|TW1DDD|256~~511|
718 +|SD0|SD0DDD|0~~255|
719 +|SD1|SD1DDD|256~~511|
720 +|CW|CWDDD|0~~306|
721 +|(% colspan="1" rowspan="2" %)Double Word|CW0|CW0DDD|200~~255|
722 +|CW1|CW1DDDDD|256~~99999|
723 +
724 +**4) Cable Wiring**
725 +
726 +(% style="text-align:center" %)
727 +[[image:Emerson.png]]
728 +
729 += HollySys PLC =
730 +
731 +== **LK Modbus RTU ** ==
732 +
733 +Supported Series: HollySys LK series PLC
734 +
735 +**1)V-BOX setting**
736 +
737 +|**Items**|**Settings**|**Note**
738 +|Protocol|HollySys LK Modbus RTU|
739 +|Connection|RS485|
740 +|Baud rate|38400|
741 +|Data bit|8|
742 +|Parity|None|
743 +|Stop bit|1|
744 +|Device station No.|1|
745 +
746 +**2)Address List**
747 +
748 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
749 +|Bit|QX|QXDDDDD.dd|0~~65535.15|
750 +|Bit|IX|IXDDDDD.dd|0~~65535.15|
751 +|Bit|MX|MXDDDDD.dd|0~~65535.15|
752 +|Word|QW|QWDDDDD|0~~99999|
753 +|Word|IW|IWDDDDD|0~~99999|
754 +|Word|MW|MWDDDDD|0~~99999|
755 +|Word|MD|MDDDDDD|0~~99999|
756 +
757 +**3)Cable Wiring**
758 +
759 +(% style="text-align:center" %)
760 +[[image:Hollysys485-2.png]]
761 +
762 +== **LM Modbus RTU** ==
763 +
764 +(% class="wikigeneratedid" %)
765 +Supported Series: HollySys LM3109/LM3107 PLC
766 +
767 +(% class="wikigeneratedid" %)
768 +**1)V-BOX setting**
769 +
770 +|(% style="width:208px" %)**Items**|(% style="width:310px" %)**Settings**|(% style="width:365px" %)**Optional**|(% style="width:152px" %)**Note**
771 +|(% style="width:208px" %)Protocol|(% style="width:310px" %)HollySys LM Modbus RTU|(% style="width:365px" %)HollySys LM Modbus RTU|(% style="width:152px" %)
772 +|(% style="width:208px" %)Connection|(% style="width:310px" %)RS232|(% style="width:365px" %)RS485|(% style="width:152px" %)
773 +|(% style="width:208px" %)Baud rate|(% style="width:310px" %)38400|(% style="width:365px" %)38400|(% style="width:152px" %)
774 +|(% style="width:208px" %)Data bit|(% style="width:310px" %)8|(% style="width:365px" %)8|(% style="width:152px" %)
775 +|(% style="width:208px" %)Parity|(% style="width:310px" %)None|(% style="width:365px" %)None|(% style="width:152px" %)
776 +|(% style="width:208px" %)Stop bit|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
777 +|(% style="width:208px" %)Device station No.|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
778 +
779 +**2)Address List**
780 +
781 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
782 +|Bit|QX|QXDDDDD.o|0~~99999.7|
783 +|Bit|IX|IXDDDDD.o|0~~99999.7|
784 +|Bit|MX|MXDDDDD.o|0~~99999.7|
785 +|Word|QW|QWDDDDD|0~~99999|
786 +|Word|IW|IWDDDDD|0~~99999|
787 +|Word|MW|MWDDDDD|0~~99999|
788 +|Word|MD|MDDDDDD|0~~99999|
789 +
790 +**Cable Wiring**
791 +
792 +RS232
793 +
794 +(% style="text-align:center" %)
795 +[[image:HollySysRS232.png]]
796 +
797 +RS485
798 +
799 +(% style="text-align:center" %)
800 +[[image:Hollysys LM Modbus RTU.gif]]
801 +
802 += **Siemens ** =
803 +
804 +== **S7-200 Smart Ethernet ** ==
805 +
806 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
807 +
808 +== **S7-300 Ethernet ** ==
809 +
533 533  Supported Series: Siemens S7-300 series PLC
534 534  
535 535  **1)V-BOX setting**
... ... @@ -586,11 +586,11 @@
586 586  )))
587 587  )))
588 588  
589 -== **S7-1200 Ethernet Protocol** ==
866 +== **S7-1200 Ethernet ** ==
590 590  
591 591  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
592 592  
593 -== **S7-XXX Ethernet Protocol** ==
870 +== **S7-XXX Ethernet l** ==
594 594  
595 595  Supported Series: Siemens S7-400, S7-1200 and S7-1500
596 596  
... ... @@ -704,12 +704,101 @@
704 704  
705 705  [[image:image-20220824162342-2.png]]
706 706  
707 -== **LOGO Ethernet Protocol** ==
984 +== **LOGO Ethernet ** ==
708 708  
709 -= Create communication with **Mitsubishi PLC** =
986 +Supported Series: Siemens Logo 0BA0, 0BA1 series
710 710  
711 -== **FX1S,1N,2N Serial Protocol** ==
988 +**V-BOX Settings**
712 712  
990 +
991 +|**Items**|**Settings**|**Note**
992 +|Protocol|Siemens LOGO|
993 +|Connection|Ethernet|
994 +|Port No.|102|
995 +|PLC station No.|2|
996 +
997 +**Address List**
998 +
999 +
1000 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
1001 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
1002 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
1003 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
1004 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
1005 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
1006 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
1007 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
1008 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
1009 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
1010 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
1011 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
1012 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
1013 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
1014 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
1015 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
1016 +
1017 +**PLC Settings in LOGO Software:**
1018 +
1019 +Click [Tools]~-~-[Ethernet Connections],shown as below.
1020 +
1021 +(% style="text-align:center" %)
1022 +[[image:PIStudio.12\.PLC protocols.WebHome@12.PLC Protocol_html_8b9d2322edf89519.png]]
1023 +
1024 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
1025 +
1026 +(% style="text-align:center" %)
1027 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228142937-4.png]]
1028 +
1029 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
1030 +
1031 +(% style="text-align:center" %)
1032 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143047-5.png]]
1033 +
1034 + **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
1035 +
1036 +(% style="text-align:center" %)
1037 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143246-6.png]]
1038 +
1039 +**V-BOX Communication Settings**
1040 +
1041 +Set PLC IP in [IP Address] settings;
1042 +
1043 +(% style="text-align:center" %)
1044 +[[image:LldwDGntf4.png]]
1045 +
1046 +Enable V-BOX Ethernet in [Network];
1047 +
1048 +(% style="text-align:center" %)
1049 +[[image:WgvjfWbQif.png]]
1050 +
1051 +TSAP setting
1052 +
1053 +* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful.
1054 +
1055 +{{code language="LUA"}}
1056 +function init.main()
1057 +addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
1058 +addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
1059 +end
1060 +{{/code}}
1061 +
1062 +Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code.
1063 +
1064 +**✎Note:**
1065 +
1066 +* **Communication port configuration: **
1067 +** Continuous length needs to be set to 0.
1068 +** Integration interval needs to be set to 1. (no change may result in data errors)
1069 +** Set Port and Device Station NO.
1070 +** Other set as defaulted.
1071 +* **Notes on the use of registers:**
1072 +** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
1073 +** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
1074 +
1075 += **Mitsubishi ** =
1076 +
1077 +== **FX1S,1N,2N Serial ** ==
1078 +
713 713  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
714 714  
715 715  **1)V-BOX Settings**
... ... @@ -755,7 +755,7 @@
755 755  [[image:image-20220825100845-4.png]]
756 756  
757 757  
758 -== **FX3U,3G,3GA Serial Protocol** ==
1124 +== **FX3U,3G,3GA Serial ** ==
759 759  
760 760  Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
761 761  
... ... @@ -802,7 +802,7 @@
802 802  [[image:image-20220825100845-4.png]]
803 803  
804 804  
805 -== **FX3U Ethernet Protocol** ==
1171 +== **FX3U Ethernet ** ==
806 806  
807 807  Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
808 808  
... ... @@ -897,7 +897,7 @@
897 897  
898 898  [[image:image-20221119101946-2.png||height="395" width="695"]]
899 899  
900 -== **FX5U Serial Protocol** ==
1266 +== **FX5U Serial ** ==
901 901  
902 902  Mitsubishi FX5U series PLC
903 903  
... ... @@ -979,7 +979,7 @@
979 979  
980 980  [[image:image-20220825105533-3.png]]
981 981  
982 -== **FX5U Ethernet Protocol** ==
1348 +== **FX5U Ethernet ** ==
983 983  
984 984  Mitsubishi FX5U series PLC
985 985  
... ... @@ -1055,7 +1055,7 @@
1055 1055  
1056 1056  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1057 1057  
1058 -== **L02 Serial Protocol** ==
1424 +== **L02 Serial ** ==
1059 1059  
1060 1060  Mitsubishi L02 series CPU built-in serial port.
1061 1061  
... ... @@ -1115,7 +1115,7 @@
1115 1115  
1116 1116  [[image:image-20220825160820-4.png]]
1117 1117  
1118 -== **L02 Ethernet Protocol** ==
1484 +== **L02 Ethernet ** ==
1119 1119  
1120 1120  Mitsubishi L series CPU built-in Ethernet port.
1121 1121  
... ... @@ -1188,13 +1188,13 @@
1188 1188  
1189 1189  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1190 1190  
1191 -== **Q12H Serial Protocol** ==
1557 +== **Q12H Serial ** ==
1192 1192  
1193 1193  This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
1194 1194  
1195 1195  [[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]
1196 1196  
1197 -== **QJ71E71 Ethernet Protocol** ==
1563 +== **QJ71E71 Ethernet ** ==
1198 1198  
1199 1199  Mitsubishi QJ71E71 Ethernet communication module;
1200 1200  
... ... @@ -1269,9 +1269,9 @@
1269 1269  
1270 1270  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
1271 1271  
1272 -= Create communication with **Delta PLC** =
1638 += **Delta** =
1273 1273  
1274 -== **DVP Ethernet Protocol** ==
1640 +== **DVP Ethernet** ==
1275 1275  
1276 1276  Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module
1277 1277  
... ... @@ -1336,7 +1336,7 @@
1336 1336  (% style="text-align:center" %)
1337 1337  [[image:DVPEthernetVNETPortocol.png]]
1338 1338  
1339 -== **DVP serial protocol** ==
1705 +== **DVP serial** ==
1340 1340  
1341 1341  Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX
1342 1342  
... ... @@ -1372,7 +1372,7 @@
1372 1372  (% style="text-align:center" %)
1373 1373  [[image:Delta DVP PROTOCOLSerial232.png]]
1374 1374  
1375 -== **AS Ethernet Protocol** ==
1741 +== **AS Ethernet** ==
1376 1376  
1377 1377  **1)V-BOX Settings**
1378 1378  
... ... @@ -1417,19 +1417,18 @@
1417 1417  
1418 1418  [[image:image-20220831155157-3.png]]
1419 1419  
1420 -= Create communication with **Omron PLC** =
1786 += **Omron** =
1421 1421  
1422 -== **CP1 Series Protocol ** ==
1788 +== **CP1 Series** ==
1423 1423  
1424 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1790 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1425 1425  
1426 -== **CP2M Series Protocol** ==
1792 +== **CP2M Series** ==
1427 1427  
1428 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1794 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1429 1429  
1796 +== **EC55 Series ** ==
1430 1430  
1431 -== **EC55 Series Protocol** ==
1432 -
1433 1433  Supported device: EC55 temperature instrument
1434 1434  
1435 1435  **1)V-BOX Settings**
... ... @@ -1489,9 +1489,9 @@
1489 1489  * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1490 1490  * [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1491 1491  
1492 -= Create communication with Xinje** PLC** =
1857 += Xinje =
1493 1493  
1494 -== **XC serial protocol** ==
1859 +== **XC serial** ==
1495 1495  
1496 1496  **1)V-BOX Settings**
1497 1497  
... ... @@ -1533,7 +1533,7 @@
1533 1533  
1534 1534  [[image:image-20220831163441-4.png]]
1535 1535  
1536 -== **XD serial protocol** ==
1901 +== **XD serial** ==
1537 1537  
1538 1538  **1)V-BOX Settings**
1539 1539  
... ... @@ -1607,7 +1607,7 @@
1607 1607  
1608 1608  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1609 1609  
1610 -= Create communication with **Schneider PLC** =
1975 += **Schneider** =
1611 1611  
1612 1612  == **Schneider MODBUS RTU** ==
1613 1613  
... ... @@ -1641,9 +1641,9 @@
1641 1641  
1642 1642  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
1643 1643  
1644 -= Create communication with Inovance** PLC** =
2009 += Inovance =
1645 1645  
1646 -== **H3U serial protocol** ==
2011 +== **H3U serial** ==
1647 1647  
1648 1648  **1)V-BOX Settings**
1649 1649  
... ... @@ -1693,9 +1693,9 @@
1693 1693  
1694 1694  [[image:image-20220831164731-4.png]]
1695 1695  
1696 -= Create communication with Panasonic** PLC** =
2061 += Panasonic =
1697 1697  
1698 -== **FP serial protocol** ==
2063 +== **FP serial** ==
1699 1699  
1700 1700  **1)V-BOX Settings**
1701 1701  
... ... @@ -1743,9 +1743,9 @@
1743 1743  
1744 1744  [[image:image-20220831165008-1.png]]
1745 1745  
1746 -= Create communication with LS** PLC** =
2111 += LS =
1747 1747  
1748 -== **XBC serial protocol** ==
2113 +== **XBC serial** ==
1749 1749  
1750 1750  **1)V-BOX Settings**
1751 1751  
... ... @@ -1797,7 +1797,7 @@
1797 1797  
1798 1798  [[image:image-20220831170215-2.png]]
1799 1799  
1800 -== **XGK FEnet Ethernet protocol** ==
2165 +== **XGK FEnet Ethernet** ==
1801 1801  
1802 1802  Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1803 1803  
... ... @@ -1840,8 +1840,76 @@
1840 1840  
1841 1841  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1842 1842  
1843 -= Create communication with **Modbus ** =
2208 += INVT =
1844 1844  
2210 +**1)V-BOX setting**
2211 +
2212 +|**Item**|**Settings**|**Note**
2213 +|Protocol|INVT_IVC2L|
2214 +|Connection|RS232|
2215 +|Baud rate|19200|
2216 +|Data bit|8|
2217 +|Parity|EVEN|
2218 +|Stop bit|1|
2219 +|PLC station No.|1
2220 +
2221 +**2)Address List**
2222 +
2223 +
2224 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
2225 +|(% colspan="1" rowspan="7" %)Bit|X|XOOO|0~~377|
2226 +|Y|YOOO|0~~377|
2227 +|M|MDDDD|0~~1999|
2228 +|SM|SMDDD|0~~255|
2229 +|S|SDDD|0~~991|
2230 +|T|TDDD|0~~255|
2231 +|C|CDDD|0~~255|
2232 +|(% rowspan="5" %)Word|D|DDDDD|0~~7999|
2233 +|SD|SDDDD|0~~255|
2234 +|Z|ZDD|0~~15|
2235 +|T|TDDD|0~~255|
2236 +|C|CDDD|0~~199|
2237 +|Double word|C|CDDD|200~~255|
2238 +
2239 +**3)Communication Settings**
2240 +
2241 +(% style="text-align:center" %)
2242 +[[image:盒子创建英威腾.png]]
2243 +
2244 +**4)PLC software**
2245 +
2246 +(% style="text-align:center" %)
2247 +[[image:英威腾软件.png]]
2248 +
2249 +**5)PLC setting **
2250 +
2251 +Open the INVI plc software, create a new project or open a project that has already been created
2252 +
2253 +(% style="text-align:center" %)
2254 +[[image:英威腾创建1.png]]
2255 +
2256 +Configure serial port parameters.
2257 +
2258 +(% style="text-align:center" %)
2259 +[[image:英威腾创建2.png]]
2260 +
2261 +PC connect PLC
2262 +
2263 +(% style="text-align:center" %)
2264 +[[image:英威腾创建3.png]]
2265 +
2266 +Download
2267 +
2268 +(% style="text-align:center" %)
2269 +[[image:英威腾下载.png]]
2270 +
2271 +**6)Cable Wiring**
2272 +
2273 +(% style="text-align:center" %)
2274 +[[image:wire.png]]
2275 +
2276 += **Modbus ** =
2277 +
1845 1845  == **MODBUS RTU Slave (All function)** ==
1846 1846  
1847 1847  Select the protocol "Modbus RTU Slave (All Fuction)",
... ... @@ -1851,6 +1851,86 @@
1851 1851  (% style="text-align:center" %)
1852 1852  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
1853 1853  
2287 +== **Modbus Meter** ==
2288 +
2289 +The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication.
2290 +
2291 +~1. Wiring the RS485 cable first. Because the pin 58 is A, the pin 59 is B for meter. Here we use the COM1 to connect. So the diagram like follows:
2292 +
2293 +(% style="text-align:center" %)
2294 +[[image:LinfeeTerminalDiagram.png]]
2295 +
2296 +2. Check the specific Modbus parameter in the communication menu from LED display.
2297 +
2298 +So from the following pictures, we can know the Meter Address is 85, Baud rate is 9600, CRC None.
2299 +
2300 +{{info}}
2301 +**✎Note: **Meter address usually corresponding to the Modbus Slave Station No. on the Modbus communication.
2302 +{{/info}}
2303 +
2304 +(% style="text-align:center" %)
2305 +[[image:MeterModbusAllView.png]]
2306 +
2307 +(% class="wikigeneratedid" %)
2308 +3. Set up the communication in the Configuration tab.
2309 +
2310 +(% class="wikigeneratedid" %)
2311 +Select the protocol as **ModBus RTU Slave (All Function)**. And set the communication parameters like below.
2312 +
2313 +(% style="text-align:center" %)
2314 +[[image:VNETCommunicationtabmeter.png]]
2315 +
2316 +(% class="wikigeneratedid" %)
2317 +4. Create new real-time monitoring tag accroding to Modbus manual
2318 +
2319 +(% class="wikigeneratedid" %)
2320 +Enter the address we want to read from the meter. The following table is intercept part of the manual for Linfee Modbus manual.
2321 +
2322 +(% class="wikigeneratedid" %)
2323 +**0x03/0x04 command data register address**:
2324 +
2325 +(% style="width:1142.22px" %)
2326 +|(% style="display:none" %) |=(% colspan="2" rowspan="1" style="width: 165px;" %)Address(% style="display:none" %) |=Description|=Data Format|=(% style="width: 254px;" %)Data Length(Word)|=(% style="width: 282px;" %)Remark
2327 +|(%%)(% style="display:none" %) (%%) HEX|(% style="width:107px" %)DEC|(%%)(% style="display:none" %) (%%) |(% style="width:100px" %) |(%%)(% style="display:none" %) (%%) |(% style="width:318px" %)
2328 +|(% style="width:107px" %)0x00|(% style="width:100px" %)0|Reserved| | |(% style="width:318px" %)
2329 +|(% style="width:107px" %)0x02|(% style="width:100px" %)2|Reserved| | |(% style="width:318px" %)
2330 +|(% style="width:107px" %)0x04|(% style="width:100px" %)4|Reserved| | |(% style="width:318px" %)
2331 +|(% style="width:107px" %)0x06|(% style="width:100px" %)6|Ua|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2332 +|(% style="width:107px" %)0x08|(% style="width:100px" %)8|Ub|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2333 +|(% style="width:107px" %)0x0A|(% style="width:100px" %)10|Uc|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2334 +|(% style="width:107px" %)0x0C|(% style="width:100px" %)12|Uab|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2335 +|(% style="width:107px" %)0x0E|(% style="width:100px" %)14|Ubc|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2336 +|(% style="width:107px" %)0x10|(% style="width:100px" %)16|Uca|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2337 +|(% style="width:107px" %)0x12|(% style="width:100px" %)18|Ia|float|2|(% style="width:318px" %)Phase Current data, Unit A
2338 +|(% style="width:107px" %)0x14|(% style="width:100px" %)20|Ib|float|2|(% style="width:318px" %)Phase Current data, Unit A
2339 +|(% style="width:107px" %)0x16|(% style="width:100px" %)22|Ic|float|2|(% style="width:318px" %)Phase Current data, Unit A
2340 +
2341 +{{info}}
2342 +**✎Note: **We usually use the Data Type 4 for read the Modbus registers(Function Code 03)
2343 +{{/info}}
2344 +
2345 +For example, here we want to read the Phase Voltage Ua (Modbus offset 0006), the Modbus register main No. requires input decimal number, and check whether the actual address has one address offset, so the tag configured like the following screenshot:
2346 +
2347 +(% style="text-align:center" %)
2348 +[[image:VNETModbusTagSettings.png]]
2349 +
2350 +(% style="text-align:center" %)
2351 +[[image:VNETModbusTagByteSettings.png]]
2352 +
2353 +{{info}}
2354 +**✎Note: **If the read value is incorrect, please check whether need to change the Byte order.
2355 +{{/info}}
2356 +
2357 +Set the Modbus Slave Station No.
2358 +
2359 +(% style="text-align:center" %)
2360 +[[image:ModbusStationSettings.png]]
2361 +
2362 +If the communication is setup successfully, the tag will show green light.
2363 +
2364 +(% style="text-align:center" %)
2365 +[[image:Monitoringtaggreenlight.png]]
2366 +
1854 1854  == **MODBUS RTU Master** ==
1855 1855  
1856 1856  Select the protocol "Modbus RTU Master",
0Il1q9GZgk.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +24.6 KB
Content
1679563870401-671.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +39.3 KB
Content
1682233464031-639.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +15.9 KB
Content
CCW.Shell_E5Cwj4tUL3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +27.1 KB
Content
ControlStarCommunicate.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +26.0 KB
Content
ControlStarModbus.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content
ControlStarSystemBlock.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +46.3 KB
Content
CrouzetRS232 VBox.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +14.9 KB
Content
Emerson.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
Ethernet.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +45.5 KB
Content
HollySysRS232.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +10.4 KB
Content
Hollysys LM Modbus RTU.gif
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.1 KB
Content
Hollysys485-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.5 KB
Content
Hollysys485box.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.4 KB
Content
LinfeeTerminalDiagram.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content
LldwDGntf4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +24.3 KB
Content
MeterModbusAddr.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +562.5 KB
Content
MeterModbusAllView.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +1.6 MB
Content
MeterModbusBaud.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +444.0 KB
Content
MeterModbusPara.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +532.0 KB
Content
ModbusStationSettings.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +35.8 KB
Content
Monitoringtaggreenlight.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.5 KB
Content
V-NET_Client setting.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +41.9 KB
Content
V-NET_Client_ADD.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +51.4 KB
Content
V-NET_Client_KOR0AHEA4M.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +14.2 KB
Content
V-NET_Client_TIiAymnjkx.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +12.8 KB
Content
V-NET_Client_TNBuqy7T5r.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +26.7 KB
Content
V-NET_Client_communication.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +25.5 KB
Content
V-NET_Client_iKKKhcgxm1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +35.9 KB
Content
V-NET_Client_t2Rg2wpSoY.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +53.7 KB
Content
VNETCommunicationtabmeter.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +31.0 KB
Content
VNETModbusTagByteSettings.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +31.2 KB
Content
VNETModbusTagSettings.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +35.7 KB
Content
WgvjfWbQif.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +36.3 KB
Content
conne ab plc.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +43.1 KB
Content
export.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +115.2 KB
Content
export1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +115.2 KB
Content
plc 软件.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +106.8 KB
Content
project create.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +65.5 KB
Content
software.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +25.8 KB
Content
v-net client vers.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +13.1 KB
Content
wire.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +137.2 KB
Content
企业微信截图_16889606174191.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +20.7 KB
Content
盒子创建英威腾.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +86.5 KB
Content
英威腾下载.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +49.0 KB
Content
英威腾创建1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +36.7 KB
Content
英威腾创建2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +115.7 KB
Content
英威腾创建3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +76.6 KB
Content
英威腾软件.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +52.6 KB
Content