Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 205.1
edited by Bob
on 2023/02/02 11:23
Change comment: There is no comment for this version
To version 192.1
edited by Hunter
on 2022/12/01 16:28
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bob
1 +XWiki.Hunter
Content
... ... @@ -178,102 +178,6 @@
178 178  
179 179  = Create communication with **Rockwell PLC** =
180 180  
181 -== **DF1 Advanced Protocol** ==
182 -
183 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5
184 -
185 -**1) V-Box Settings**
186 -
187 -|=Item|=Recommended |=Note
188 -|=Protocol|Allen Bradley DF1 Advanced|
189 -|=Connection|RS232|
190 -|=Baud rate|19200|
191 -|=Stop bits|1|
192 -|=Data bits|8|
193 -|=Parity|None|
194 -|=PLC Station No.|1|
195 -|=HMI Station No.|0|
196 -
197 -**2) Address List**
198 -
199 -|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note
200 -|(% colspan="1" rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1
201 -|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0
202 -|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2
203 -|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3
204 -|BN|BNddddd.dd|0.0~~99255.15|(((
205 -Bit data file B0~~B99
206 -
207 -First two digits is for file number
208 -
209 -For example, BN13001.00 represents file number B13, address 001, the 0th bit.
210 -)))
211 -|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7
212 -|NN|NNddddd.dd|0.0~~99255.15|(((
213 -Integer data file bit format N0~~N99
214 -
215 -First two digits is for file number
216 -
217 -For example, NN13001.00 represents file number N13, address 001, the 0th bit.
218 -)))
219 -|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2
220 -|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value)
221 -|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value)
222 -|TNS|TNSddddd|0~~99255|(((
223 -Timer Preset Value
224 -
225 -First two digits is for file number
226 -
227 -For example, TNS99255 represents file number T99, address 255.
228 -)))
229 -|TNP|TNPddddd|0~~99255|(((
230 -Timer Accumulator Value
231 -
232 -First two digits is for file number
233 -
234 -For example, TNP99255 represents file number T99, address 255.
235 -)))
236 -|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value)
237 -|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value)
238 -|CNS|CNSddddd|0~~99255|(((
239 -Counter Preset Value
240 -
241 -First two digits is for file number
242 -
243 -For example, CNS99255 represents file number C99, address 255.
244 -)))
245 -|CNP|CNPddddd|0~~99255|(((
246 -Counter Accumulator Value
247 -
248 -First two digits is for file number
249 -
250 -For example, CNP99255 represents file number C99, address 255.
251 -)))
252 -|N7|N7ddd|0~~255|Only able to communicate with file number N7
253 -|NN|NNddd|0~~99255|(((
254 -Integer data file
255 -
256 -First two digits is for file number
257 -
258 -For example, NN99255 represents file number N99, address 255.
259 -)))
260 -|(% colspan="1" rowspan="3" %)Double Word|F8|F8ddd|0~~255|(((
261 -Only able to communicate with file number N7
262 -)))
263 -|FN|FNddddd|0~~99255|(((
264 -Floating point data file
265 -
266 -First two digits is for file number
267 -
268 -For example, FN99255 represents file number F99, address 255.
269 -)))
270 -|LN|LNddddd|0~~99255|Long
271 -
272 -**3) Cable Wiring**
273 -
274 -(% style="text-align:center" %)
275 -[[image:ABRS232.gif]]
276 -
277 277  == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
278 278  
279 279  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
... ... @@ -281,7 +281,7 @@
281 281  **1)V-BOX setting**
282 282  
283 283  |**Item**|**Settings**|**Note**
284 -|Protocol|Allen-Bradley DF1 Advanced|
188 +|Protocol|Allen-Bradlley DF1 Advanced|
285 285  |Connection|RS232|
286 286  |Baud rate|19200|
287 287  |Data bit|8|
... ... @@ -704,46 +704,6 @@
704 704  
705 705  [[image:image-20220824162342-2.png]]
706 706  
707 -== **LOGO Ethernet Protocol** ==
708 -
709 -Supported Series: Siemens Logo 0BA0, 0BA1 series
710 -
711 -**V-BOX Settings**
712 -
713 -
714 -|**Items**|**Settings**|**Note**
715 -|Protocol|Siemens LOGO|
716 -|Connection|Ethernet|
717 -|Port No.|102|
718 -|PLC station No.|2|
719 -
720 -**Address List**
721 -
722 -
723 -|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
724 -|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
725 -|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
726 -|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
727 -|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
728 -|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
729 -|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
730 -|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
731 -|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
732 -|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
733 -|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
734 -|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
735 -|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
736 -|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
737 -|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
738 -|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
739 -
740 - **PLC Settings in LOGO Software:**
741 -
742 -Click [Tools]~-~-[Ethernet Connections],shown as below.
743 -
744 -(% style="text-align:center" %)
745 -[[image:12.PLC Protocol_html_8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]]
746 -
747 747  = Create communication with **Mitsubishi PLC** =
748 748  
749 749  == **FX1S,1N,2N Serial Protocol** ==
... ... @@ -1311,7 +1311,7 @@
1311 1311  
1312 1312  == **DVP Ethernet Protocol** ==
1313 1313  
1314 -Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module
1178 +Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE, DELTA DVPEN01-SL
1315 1315  
1316 1316  **1)V-BOX Settings**
1317 1317  
... ... @@ -1324,19 +1324,19 @@
1324 1324  
1325 1325  **2)Address List **
1326 1326  
1327 -|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note**
1328 -|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOO|(% style="width:225px" %)0~~377|
1329 -|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOO|(% style="width:225px" %)0~~377|
1330 -|Bit|(% style="width:191px" %)M0|(% style="width:217px" %)M0|(% style="width:168px" %)M0DDDD|(% style="width:225px" %)0~~1535|
1331 -|Bit|(% style="width:191px" %)M1|(% style="width:217px" %)M1|(% style="width:168px" %)M1DDDD|(% style="width:225px" %)1536~~4096|
1332 -|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255|
1333 -|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~255|
1334 -|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDD|(% style="width:225px" %)0~~1023|
1335 -|Word|(% style="width:191px" %)D0|(% style="width:217px" %)D0|(% style="width:168px" %)D0DDDD|(% style="width:225px" %)0~~4095|
1336 -|Word|(% style="width:191px" %)D1|(% style="width:217px" %)D1|(% style="width:168px" %)D1DDDD|(% style="width:225px" %)4096~~11999|
1337 -|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255|
1338 -|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199|
1339 -|Double Word|(% style="width:191px" %)HC|(% style="width:217px" %)HC|(% style="width:168px" %)HCDDD|(% style="width:225px" %)200~~255|
1191 +|=**Type**|=(% style="width: 215px;" %)**Device registers**|=(% style="width: 237px;" %)**VBox registers**|=(% style="width: 214px;" %)**Format**|=**Range**|=**Note**
1192 +|Bit|(% style="width:215px" %)X|(% style="width:237px" %)X|(% style="width:214px" %)X OOO|0~~377|
1193 +|Bit|(% style="width:215px" %)Y|(% style="width:237px" %)Y|(% style="width:214px" %)Y OOO|0~~377|
1194 +|Bit|(% style="width:215px" %)M0|(% style="width:237px" %)M0|(% style="width:214px" %)M0DDDD|0~~1535|
1195 +|Bit|(% style="width:215px" %)M1|(% style="width:237px" %)M1|(% style="width:214px" %)M1DDDD|1536~~4096|
1196 +|Bit|(% style="width:215px" %)T|(% style="width:237px" %)T|(% style="width:214px" %)TDDD|0~~255|
1197 +|Bit|(% style="width:215px" %)C|(% style="width:237px" %)C|(% style="width:214px" %)CDDD|0~~255|
1198 +|Bit|(% style="width:215px" %)S|(% style="width:237px" %)S|(% style="width:214px" %)SDDDD|0~~1023|
1199 +|Word|(% style="width:215px" %)D0|(% style="width:237px" %)D0|(% style="width:214px" %)D0DDDD|0~~4095|
1200 +|Word|(% style="width:215px" %)D1|(% style="width:237px" %)D1|(% style="width:214px" %)D1DDDD|4096~~11999|
1201 +|Word|(% style="width:215px" %)T|(% style="width:237px" %)T|(% style="width:214px" %)TDDD|0~~255|
1202 +|Word|(% style="width:215px" %)C|(% style="width:237px" %)C|(% style="width:214px" %)CDDD|0~~199|
1203 +|Double Word|(% style="width:215px" %)HC|(% style="width:237px" %)HC|(% style="width:214px" %)HCDDD|200~~255|
1340 1340  
1341 1341  **3) PLC Setting:**
1342 1342  
... ... @@ -1376,40 +1376,8 @@
1376 1376  
1377 1377  == **DVP serial protocol** ==
1378 1378  
1379 -Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX
1243 +[[Download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1380 1380  
1381 -**1)V-BOX Settings**
1382 -
1383 -|=**Items**|=**Settings**|=**Note**
1384 -|Protocol|DELTA DVP PROTOCOL|
1385 -|Connection|RS232|
1386 -|Baud Rate|9600|
1387 -|Stop Bit|1|
1388 -|Data Bit|7|
1389 -|Parity|EVEN|
1390 -|Device No.|1|
1391 -
1392 -(% class="wikigeneratedid" %)
1393 -**2)Address List**
1394 -
1395 -|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note**
1396 -|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOOOOO|(% style="width:225px" %)0~~303237|
1397 -|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOOOOO|(% style="width:225px" %)0~~303237|
1398 -|Bit|(% style="width:191px" %)M|(% style="width:217px" %)M|(% style="width:168px" %)MDDDDD|(% style="width:225px" %)0~~99999|
1399 -|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999|
1400 -|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)0~~99999|
1401 -|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDDD|(% style="width:225px" %)0~~99999|
1402 -|Word|(% style="width:191px" %)D|(% style="width:217px" %)D|(% style="width:168px" %)D DDDDD|(% style="width:225px" %)0~~99999|
1403 -|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999|
1404 -|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199|
1405 -|Double Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)200~~99999|
1406 -
1407 -(% class="wikigeneratedid" %)
1408 -**3)Wiring Diagram**
1409 -
1410 -(% style="text-align:center" %)
1411 -[[image:Delta DVP PROTOCOLSerial232.png]]
1412 -
1413 1413  == **AS Ethernet Protocol** ==
1414 1414  
1415 1415  **1)V-BOX Settings**
... ... @@ -1901,8 +1901,8 @@
1901 1901  **address list**
1902 1902  
1903 1903  (% class="table-bordered" %)
1904 -|=(% scope="row" %)**Type**|=**Data Type**|=**Function code and description**
1905 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)
1736 +|**type**|**register**|**Function code and description**
1737 +|(% rowspan="11" %)|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)
1906 1906  |06 (write single register: write a binary value to a holding register)
1907 1907  |10 (write values to multiple addresses )
1908 1908  |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
... ... @@ -1941,7 +1941,7 @@
1941 1941  
1942 1942  **2)Address List**
1943 1943  
1944 -|=**Type**|=**Data Type**|=**Function code & Description**
1776 +|**Type**|**Register**|**Function code & Description**
1945 1945  |(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1946 1946  |06 (write single register: write a binary value to a holding register)
1947 1947  |10 (write values to multiple addresses )
AB.gif
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -7.3 KB
Content
ABRS232.gif
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -7.3 KB
Content
Delta DVP PROTOCOLSerial232.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -10.7 KB
Content