Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bob1 +XWiki.Hunter - Content
-
... ... @@ -176,7 +176,7 @@ 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 178 178 179 -= Create communication with **Rockwell 179 += Create communication with Allen-Bradley(**Rockwell**)** PLC** = 180 180 181 181 == **DF1 Advanced Protocol** == 182 182 ... ... @@ -274,8 +274,12 @@ 274 274 (% style="text-align:center" %) 275 275 [[image:ABRS232.gif]] 276 276 277 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 277 +(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %) 278 +(% id="cke_bm_5621S" style="display:none" %)** ** 278 278 280 +== **MicroLogix Protocol** == 281 + 282 +(% class="wikigeneratedid" %) 279 279 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 280 280 281 281 **1)V-BOX setting** ... ... @@ -515,12 +515,17 @@ 515 515 ((( 516 516 The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. 517 517 522 +== **Allen-Bradley Ethernet DF1** == 518 518 519 -= **Allen-Bradley Ethernet DF1** = 520 - 521 521 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 522 522 526 += Create communication with **Crouzet PLC** = 523 523 528 +== **CROUZET M3 (FBD)** == 529 + 530 +**1)V-BOX setting** 531 + 532 + 524 524 = Create communication with **Siemens PLC** = 525 525 526 526 == **S7-200 Smart Ethernet Protocol** == ... ... @@ -737,7 +737,7 @@ 737 737 |14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70 738 738 |15|V|Bit|0-14697|DB1.DBX0.0|0x000000 739 739 740 - 749 +**PLC Settings in LOGO Software:** 741 741 742 742 Click [Tools]~-~-[Ethernet Connections],shown as below. 743 743 ... ... @@ -744,6 +744,57 @@ 744 744 (% style="text-align:center" %) 745 745 [[image:PIStudio.12\.PLC protocols.WebHome@12.PLC Protocol_html_8b9d2322edf89519.png]] 746 746 756 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 757 + 758 +(% style="text-align:center" %) 759 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228142937-4.png]] 760 + 761 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 762 + 763 +(% style="text-align:center" %) 764 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143047-5.png]] 765 + 766 + **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 767 + 768 +(% style="text-align:center" %) 769 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143246-6.png]] 770 + 771 +**V-BOX Communication Settings** 772 + 773 +Set PLC IP in [IP Address] settings; 774 + 775 +(% style="text-align:center" %) 776 +[[image:LldwDGntf4.png]] 777 + 778 +Enable V-BOX Ethernet in [Network]; 779 + 780 +(% style="text-align:center" %) 781 +[[image:WgvjfWbQif.png]] 782 + 783 +TSAP setting 784 + 785 +* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful. 786 + 787 +{{code language="LUA"}} 788 +function init.main() 789 +addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address 790 +addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address 791 +end 792 +{{/code}} 793 + 794 +Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 795 + 796 +**✎Note:** 797 + 798 +* **Communication port configuration: ** 799 +** Continuous length needs to be set to 0. 800 +** Integration interval needs to be set to 1. (no change may result in data errors) 801 +** Set Port and Device Station NO. 802 +** Other set as defaulted. 803 +* **Notes on the use of registers:** 804 +** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc. 805 +** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 ) 806 + 747 747 = Create communication with **Mitsubishi PLC** = 748 748 749 749 == **FX1S,1N,2N Serial Protocol** ==
- 0Il1q9GZgk.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.6 KB - Content
- LldwDGntf4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.3 KB - Content
- WgvjfWbQif.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.3 KB - Content