Changes for page 1 Communication
Last modified by xingzhi lin on 2025/08/01 15:25
From version 206.1
edited by Bob
on 2023/02/02 11:24
on 2023/02/02 11:24
Change comment:
There is no comment for this version
To version 259.1
edited by Theodore Xu
on 2023/08/23 19:35
on 2023/08/23 19:35
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 49 added, 0 removed)
- 0Il1q9GZgk.png
- 1679563870401-671.png
- 1682233464031-639.png
- CCW.Shell_E5Cwj4tUL3.png
- ControlStarCommunicate.png
- ControlStarModbus.png
- ControlStarSystemBlock.png
- CrouzetRS232 VBox.png
- Emerson.png
- Ethernet.png
- HollySysRS232.png
- Hollysys LM Modbus RTU.gif
- Hollysys485-2.png
- Hollysys485box.png
- LinfeeTerminalDiagram.png
- LldwDGntf4.png
- MeterModbusAddr.png
- MeterModbusAllView.png
- MeterModbusBaud.png
- MeterModbusPara.png
- ModbusStationSettings.png
- Monitoringtaggreenlight.png
- V-NET_Client setting.png
- V-NET_Client_ADD.png
- V-NET_Client_KOR0AHEA4M.png
- V-NET_Client_TIiAymnjkx.png
- V-NET_Client_TNBuqy7T5r.png
- V-NET_Client_communication.png
- V-NET_Client_iKKKhcgxm1.png
- V-NET_Client_t2Rg2wpSoY.png
- VNETCommunicationtabmeter.png
- VNETModbusTagByteSettings.png
- VNETModbusTagSettings.png
- WgvjfWbQif.png
- conne ab plc.png
- export.png
- export1.png
- plc 软件.png
- project create.png
- software.png
- v-net client vers.png
- wire.png
- 企业微信截图_16889606174191.png
- 盒子创建英威腾.png
- 英威腾下载.png
- 英威腾创建1.png
- 英威腾创建2.png
- 英威腾创建3.png
- 英威腾软件.png
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bob1 +XWiki.AiXia - Content
-
... ... @@ -1,6 +1,6 @@ 1 -= Create communication withWECONPLC=1 += WECON = 2 2 3 -== **LX3V Serial Protocol** ==3 +== **LX3V Serial ** == 4 4 5 5 Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 ... ... @@ -48,7 +48,7 @@ 48 48 49 49 [[image:image-20220824120524-3.png]] 50 50 51 -== **LX5V Serial Protocol** ==51 +== **LX5V Serial ** == 52 52 53 53 This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. 54 54 ... ... @@ -118,7 +118,7 @@ 118 118 119 119 The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC. 120 120 121 -== **LX5V-N Ethernet protocol** ==121 +== **LX5V-N Ethernet ** == 122 122 123 123 This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. 124 124 ... ... @@ -176,9 +176,9 @@ 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 178 178 179 -= Create communication with**RockwellPLC** =179 += Allen-Bradley(**Rockwell**) = 180 180 181 -== **DF1 Advanced Protocol** ==181 +== **DF1 Advanced Serial** == 182 182 183 183 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 184 184 ... ... @@ -274,8 +274,12 @@ 274 274 (% style="text-align:center" %) 275 275 [[image:ABRS232.gif]] 276 276 277 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 277 +(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %) 278 +(% id="cke_bm_5621S" style="display:none" %)** ** 278 278 280 +== **MicroLogix Serial** == 281 + 282 +(% class="wikigeneratedid" %) 279 279 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 280 280 281 281 **1)V-BOX setting** ... ... @@ -313,7 +313,7 @@ 313 313 314 314 [[image:image-20220824110724-1.png]] 315 315 316 -== **Micro850_FreeTag Protocol** ==320 +== **Micro850_FreeTag Ethernet** == 317 317 318 318 ((( 319 319 ((( ... ... @@ -516,20 +516,293 @@ 516 516 The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. 517 517 518 518 519 -= ** Allen-BradleyEthernetDF1** =523 +== **Micro850_FreeTag Ethernet(new)** == 520 520 525 +This example introduces the establishment of Ethernet communication between Wecon V-box and 2080-LC50-48QWB,Micro850. It is introduced through three parts: PLC software configuration, V-box software configuration. 526 + 527 +(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %) 528 +((( 529 +**Software configuration of PLC** 530 +))) 531 + 532 +(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %) 533 +((( 534 +**1)PLC programming software:Connected Components Workbench™** 535 + 536 +(% style="text-align:center" %) 537 +[[image:software.png]] 538 + 539 +**2)New PLC project** 540 + 541 +Click New Project and select the PLC model. 542 + 543 +(% style="text-align:center" %) 544 +[[image:project create.png]] 545 + 546 +**3)Set Ethernet parameters** 547 + 548 +Follow the steps below to configure Ethernet parameters 549 + 550 +PLC IP address:192.168.39.56 551 + 552 +default gateway:192.168.39.1 553 + 554 +subnet mask:255.255.255.0 555 + 556 +(% style="text-align:center" %) 557 +[[image:Ethernet.png]] 558 + 559 +**4)connect PLC** 560 + 561 +**When downloading the setting, need to change the status of the PLC to PRG** 562 + 563 +(% style="text-align:center" %) 564 +[[image:conne ab plc.png]] 565 + 566 +**V-box software configuration** 567 + 568 +**1)V-box programming software** 569 + 570 +(% style="text-align:center" %) 571 +[[image:v-net client vers.png]] 572 + 573 +**2)Set communication port parameters** 574 + 575 +In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol. 576 + 577 +(% style="text-align:center" %) 578 +[[image:V-NET_Client_t2Rg2wpSoY.png]] 579 + 580 +The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. 581 + 582 +(% style="text-align:center" %) 583 +[[image:V-NET_Client_communication.png]] 584 + 585 +Export variables from PLC, select CSV file, comma delimited.(% id="cke_bm_1950S" style="display:none" %) 586 + 587 +(% style="text-align:center" %) 588 +[[image:export1.png]] 589 + 590 +(% style="text-align:center" %) 591 +[[image:CCW.Shell_E5Cwj4tUL3.png]] 592 + 593 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png"]]icon add label. 594 + 595 +(% style="text-align:center" %) 596 +[[image:V-NET_Client_TNBuqy7T5r.png]] 597 + 598 +**3)Engineering production** 599 + 600 +According to your own needs, use the V-NET client software to edit the required data monitoring points. 601 + 602 +(% style="text-align:center" %) 603 +[[image:V-NET_Client_KOR0AHEA4M.png]] 604 + 605 + 606 +))) 607 + 608 +== **Ethernet DF1** == 609 + 521 521 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 522 522 612 += **Crouzet PLC** = 523 523 524 -= C reatecommunicationwith **Siemens PLC** =614 +== **CROUZET M3 (FBD) Serial** == 525 525 526 - == **S7-200 SmartEthernet Protocol**==616 +Support Series: Crouzet Millenium 3 CD12/CB12 527 527 528 - [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]618 +**1)V-BOX setting** 529 529 620 +|=Item|=Recommended |=Note 621 +|=Protocol|CROUZET M3 (FBD)| 622 +|=Connection|RS232| 623 +|=Baud rate|115200| 624 +|=Stop bits|1| 625 +|=Data bits|7| 626 +|=Parity|EVEN| 530 530 531 - ==**S7-300 EthernetProtocol**==628 +**2)Address List** 532 532 630 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note 631 +|(% rowspan="4" %)Bit|I|I DD|1~~99|Input 632 +|SLIBit|SLIBit DD.dd|1.0~~24.15|Serial Link Input 633 +|SLOBit|SLOBit DD.dd|25.0~~48.15|Serial Link Output(Read only) 634 +|State|State D|1~~1|PLC state(Read only) 635 +|(% rowspan="5" %)Word|AI|AI DD|1~~99|Analog Input 636 +|SLIn|SLIn DD|1~~24|Serial Link Input 637 +|SLOut|SLOut DD|25~~48|Serial Link Output(Read only) 638 +|Time|Time D|1~~6|((( 639 +Time1: Second 640 + 641 +Time2: Minute 642 + 643 +Time3: Hour 644 + 645 +Time4: Day 646 + 647 +Time5: Month 648 + 649 +Time6: Year 650 +))) 651 +|Order|Order D|1~~1|((( 652 +Running command(Write only) 653 + 654 +~=2: Run mode; =1: Stop mode; 655 +))) 656 + 657 +**3)Cable Wiring** 658 + 659 +(% style="text-align:center" %) 660 +[[image:CrouzetRS232 VBox.png]] 661 + 662 +{{info}} 663 +**✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details. 664 +{{/info}} 665 + 666 += EMERSON = 667 + 668 += **RTU Slave ** = 669 + 670 +Supported series: EC10 series 671 + 672 +**1)V-BOX setting** 673 + 674 +|**Items**|**Settings**|**Note** 675 +|Protocol|Emerson 984 RTU Slave MODBUS| 676 +|Connection|RS485| 677 +|Baud rate|19200| 678 +|Data bit|8| 679 +|Parity|EVEN| 680 +|Stop bit|1| 681 +|Device station No.|1|Need to be same as the PLC setting 682 + 683 +(% class="wikigeneratedid" %) 684 +**2)PLC Setting** 685 + 686 +(% class="wikigeneratedid" %) 687 +Remember to use the Control Star to enable the Modbus RTU communication for port 1 in system block before dowload into PLC. 688 + 689 +(% style="text-align:center" %) 690 +[[image:ControlStarSystemBlock.png]] 691 + 692 +(% style="text-align:center" %) 693 +[[image:ControlStarCommunicate.png]] 694 + 695 +(% style="text-align:center" %) 696 +[[image:ControlStarModbus.png]] 697 + 698 +(% class="wikigeneratedid" %) 699 +**3)Address List** 700 + 701 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 702 +|(% colspan="1" rowspan="12" %)Bit|Y|YOOO|0~~377| 703 +|X|XOOO|0~~377| 704 +|M0|M0DDDD|0~~2047| 705 +|M1|M1DDDDD|2048~~10239| 706 +|SM0|SM0DDD|0~~255| 707 +|SM1|SM1DDD|256~~511| 708 +|S0|S0DDDD|0~~1023| 709 +|S1|S1DDDD|1024~~4095| 710 +|T0|T0DDD|0~~255| 711 +|T1|T1DDD|256~~511| 712 +|C0|C0DDD|0~~255| 713 +|C1|C1DDD|256~~306| 714 +|(% colspan="1" rowspan="7" %)Word|D|DDDDD|0~~7999| 715 +|Z|ZDD|0~~15| 716 +|TW0|TW0DDD|0~~255| 717 +|TW1|TW1DDD|256~~511| 718 +|SD0|SD0DDD|0~~255| 719 +|SD1|SD1DDD|256~~511| 720 +|CW|CWDDD|0~~306| 721 +|(% colspan="1" rowspan="2" %)Double Word|CW0|CW0DDD|200~~255| 722 +|CW1|CW1DDDDD|256~~99999| 723 + 724 +**4) Cable Wiring** 725 + 726 +(% style="text-align:center" %) 727 +[[image:Emerson.png]] 728 + 729 += HollySys PLC = 730 + 731 +== **LK Modbus RTU ** == 732 + 733 +Supported Series: HollySys LK series PLC 734 + 735 +**1)V-BOX setting** 736 + 737 +|**Items**|**Settings**|**Note** 738 +|Protocol|HollySys LK Modbus RTU| 739 +|Connection|RS485| 740 +|Baud rate|38400| 741 +|Data bit|8| 742 +|Parity|None| 743 +|Stop bit|1| 744 +|Device station No.|1| 745 + 746 +**2)Address List** 747 + 748 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** 749 +|Bit|QX|QXDDDDD.dd|0~~65535.15| 750 +|Bit|IX|IXDDDDD.dd|0~~65535.15| 751 +|Bit|MX|MXDDDDD.dd|0~~65535.15| 752 +|Word|QW|QWDDDDD|0~~99999| 753 +|Word|IW|IWDDDDD|0~~99999| 754 +|Word|MW|MWDDDDD|0~~99999| 755 +|Word|MD|MDDDDDD|0~~99999| 756 + 757 +**3)Cable Wiring** 758 + 759 +(% style="text-align:center" %) 760 +[[image:Hollysys485-2.png]] 761 + 762 +== **LM Modbus RTU** == 763 + 764 +(% class="wikigeneratedid" %) 765 +Supported Series: HollySys LM3109/LM3107 PLC 766 + 767 +(% class="wikigeneratedid" %) 768 +**1)V-BOX setting** 769 + 770 +|(% style="width:208px" %)**Items**|(% style="width:310px" %)**Settings**|(% style="width:365px" %)**Optional**|(% style="width:152px" %)**Note** 771 +|(% style="width:208px" %)Protocol|(% style="width:310px" %)HollySys LM Modbus RTU|(% style="width:365px" %)HollySys LM Modbus RTU|(% style="width:152px" %) 772 +|(% style="width:208px" %)Connection|(% style="width:310px" %)RS232|(% style="width:365px" %)RS485|(% style="width:152px" %) 773 +|(% style="width:208px" %)Baud rate|(% style="width:310px" %)38400|(% style="width:365px" %)38400|(% style="width:152px" %) 774 +|(% style="width:208px" %)Data bit|(% style="width:310px" %)8|(% style="width:365px" %)8|(% style="width:152px" %) 775 +|(% style="width:208px" %)Parity|(% style="width:310px" %)None|(% style="width:365px" %)None|(% style="width:152px" %) 776 +|(% style="width:208px" %)Stop bit|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %) 777 +|(% style="width:208px" %)Device station No.|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %) 778 + 779 +**2)Address List** 780 + 781 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** 782 +|Bit|QX|QXDDDDD.o|0~~99999.7| 783 +|Bit|IX|IXDDDDD.o|0~~99999.7| 784 +|Bit|MX|MXDDDDD.o|0~~99999.7| 785 +|Word|QW|QWDDDDD|0~~99999| 786 +|Word|IW|IWDDDDD|0~~99999| 787 +|Word|MW|MWDDDDD|0~~99999| 788 +|Word|MD|MDDDDDD|0~~99999| 789 + 790 +**Cable Wiring** 791 + 792 +RS232 793 + 794 +(% style="text-align:center" %) 795 +[[image:HollySysRS232.png]] 796 + 797 +RS485 798 + 799 +(% style="text-align:center" %) 800 +[[image:Hollysys LM Modbus RTU.gif]] 801 + 802 += **Siemens ** = 803 + 804 +== **S7-200 Smart Ethernet ** == 805 + 806 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 807 + 808 +== **S7-300 Ethernet ** == 809 + 533 533 Supported Series: Siemens S7-300 series PLC 534 534 535 535 **1)V-BOX setting** ... ... @@ -586,11 +586,11 @@ 586 586 ))) 587 587 ))) 588 588 589 -== **S7-1200 Ethernet Protocol** ==866 +== **S7-1200 Ethernet ** == 590 590 591 591 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 592 592 593 -== **S7-XXX Ethernet Protocol** ==870 +== **S7-XXX Ethernet l** == 594 594 595 595 Supported Series: Siemens S7-400, S7-1200 and S7-1500 596 596 ... ... @@ -704,7 +704,7 @@ 704 704 705 705 [[image:image-20220824162342-2.png]] 706 706 707 -== **LOGO Ethernet Protocol** ==984 +== **LOGO Ethernet ** == 708 708 709 709 Supported Series: Siemens Logo 0BA0, 0BA1 series 710 710 ... ... @@ -737,7 +737,7 @@ 737 737 |14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70 738 738 |15|V|Bit|0-14697|DB1.DBX0.0|0x000000 739 739 740 - 1017 +**PLC Settings in LOGO Software:** 741 741 742 742 Click [Tools]~-~-[Ethernet Connections],shown as below. 743 743 ... ... @@ -744,10 +744,61 @@ 744 744 (% style="text-align:center" %) 745 745 [[image:PIStudio.12\.PLC protocols.WebHome@12.PLC Protocol_html_8b9d2322edf89519.png]] 746 746 747 - =Createcommunicationwith **MitsubishiPLC**=1024 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 748 748 749 -== **FX1S,1N,2N Serial Protocol** == 1026 +(% style="text-align:center" %) 1027 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228142937-4.png]] 750 750 1029 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 1030 + 1031 +(% style="text-align:center" %) 1032 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143047-5.png]] 1033 + 1034 + **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 1035 + 1036 +(% style="text-align:center" %) 1037 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143246-6.png]] 1038 + 1039 +**V-BOX Communication Settings** 1040 + 1041 +Set PLC IP in [IP Address] settings; 1042 + 1043 +(% style="text-align:center" %) 1044 +[[image:LldwDGntf4.png]] 1045 + 1046 +Enable V-BOX Ethernet in [Network]; 1047 + 1048 +(% style="text-align:center" %) 1049 +[[image:WgvjfWbQif.png]] 1050 + 1051 +TSAP setting 1052 + 1053 +* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful. 1054 + 1055 +{{code language="LUA"}} 1056 +function init.main() 1057 +addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address 1058 +addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address 1059 +end 1060 +{{/code}} 1061 + 1062 +Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 1063 + 1064 +**✎Note:** 1065 + 1066 +* **Communication port configuration: ** 1067 +** Continuous length needs to be set to 0. 1068 +** Integration interval needs to be set to 1. (no change may result in data errors) 1069 +** Set Port and Device Station NO. 1070 +** Other set as defaulted. 1071 +* **Notes on the use of registers:** 1072 +** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc. 1073 +** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 ) 1074 + 1075 += **Mitsubishi ** = 1076 + 1077 +== **FX1S,1N,2N Serial ** == 1078 + 751 751 Supported Series: Mitsubishi FX1S, FX1N, FX2N series 752 752 753 753 **1)V-BOX Settings** ... ... @@ -793,7 +793,7 @@ 793 793 [[image:image-20220825100845-4.png]] 794 794 795 795 796 -== **FX3U,3G,3GA Serial Protocol** ==1124 +== **FX3U,3G,3GA Serial ** == 797 797 798 798 Supported Series: Mitsubishi FX3U, FX3G, FX3GA series 799 799 ... ... @@ -840,7 +840,7 @@ 840 840 [[image:image-20220825100845-4.png]] 841 841 842 842 843 -== **FX3U Ethernet Protocol** ==1171 +== **FX3U Ethernet ** == 844 844 845 845 Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L 846 846 ... ... @@ -935,7 +935,7 @@ 935 935 936 936 [[image:image-20221119101946-2.png||height="395" width="695"]] 937 937 938 -== **FX5U Serial Protocol** ==1266 +== **FX5U Serial ** == 939 939 940 940 Mitsubishi FX5U series PLC 941 941 ... ... @@ -1017,7 +1017,7 @@ 1017 1017 1018 1018 [[image:image-20220825105533-3.png]] 1019 1019 1020 -== **FX5U Ethernet Protocol** ==1348 +== **FX5U Ethernet ** == 1021 1021 1022 1022 Mitsubishi FX5U series PLC 1023 1023 ... ... @@ -1093,7 +1093,7 @@ 1093 1093 1094 1094 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1095 1095 1096 -== **L02 Serial Protocol** ==1424 +== **L02 Serial ** == 1097 1097 1098 1098 Mitsubishi L02 series CPU built-in serial port. 1099 1099 ... ... @@ -1153,7 +1153,7 @@ 1153 1153 1154 1154 [[image:image-20220825160820-4.png]] 1155 1155 1156 -== **L02 Ethernet Protocol** ==1484 +== **L02 Ethernet ** == 1157 1157 1158 1158 Mitsubishi L series CPU built-in Ethernet port. 1159 1159 ... ... @@ -1226,13 +1226,13 @@ 1226 1226 1227 1227 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1228 1228 1229 -== **Q12H Serial Protocol** ==1557 +== **Q12H Serial ** == 1230 1230 1231 1231 This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol 1232 1232 1233 1233 [[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]] 1234 1234 1235 -== **QJ71E71 Ethernet Protocol** ==1563 +== **QJ71E71 Ethernet ** == 1236 1236 1237 1237 Mitsubishi QJ71E71 Ethernet communication module; 1238 1238 ... ... @@ -1307,9 +1307,9 @@ 1307 1307 1308 1308 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]] 1309 1309 1310 -= Create communication with**DeltaPLC** =1638 += **Delta** = 1311 1311 1312 -== **DVP Ethernet Protocol** ==1640 +== **DVP Ethernet** == 1313 1313 1314 1314 Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module 1315 1315 ... ... @@ -1374,7 +1374,7 @@ 1374 1374 (% style="text-align:center" %) 1375 1375 [[image:DVPEthernetVNETPortocol.png]] 1376 1376 1377 -== **DVP serial protocol** ==1705 +== **DVP serial** == 1378 1378 1379 1379 Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX 1380 1380 ... ... @@ -1410,7 +1410,7 @@ 1410 1410 (% style="text-align:center" %) 1411 1411 [[image:Delta DVP PROTOCOLSerial232.png]] 1412 1412 1413 -== **AS Ethernet Protocol** ==1741 +== **AS Ethernet** == 1414 1414 1415 1415 **1)V-BOX Settings** 1416 1416 ... ... @@ -1455,19 +1455,18 @@ 1455 1455 1456 1456 [[image:image-20220831155157-3.png]] 1457 1457 1458 -= Create communication with**OmronPLC** =1786 += **Omron** = 1459 1459 1460 -== **CP1 Series Protocol** ==1788 +== **CP1 Series** == 1461 1461 1462 -[[ 下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]1790 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 1463 1463 1464 -== **CP2M Series Protocol** ==1792 +== **CP2M Series** == 1465 1465 1466 -[[ 下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]1794 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 1467 1467 1796 +== **EC55 Series ** == 1468 1468 1469 -== **EC55 Series Protocol** == 1470 - 1471 1471 Supported device: EC55 temperature instrument 1472 1472 1473 1473 **1)V-BOX Settings** ... ... @@ -1527,9 +1527,9 @@ 1527 1527 * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests. 1528 1528 * [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written. 1529 1529 1530 -= Create communication withXinje** PLC**=1857 += Xinje = 1531 1531 1532 -== **XC serial protocol** ==1859 +== **XC serial** == 1533 1533 1534 1534 **1)V-BOX Settings** 1535 1535 ... ... @@ -1571,7 +1571,7 @@ 1571 1571 1572 1572 [[image:image-20220831163441-4.png]] 1573 1573 1574 -== **XD serial protocol** ==1901 +== **XD serial** == 1575 1575 1576 1576 **1)V-BOX Settings** 1577 1577 ... ... @@ -1645,7 +1645,7 @@ 1645 1645 1646 1646 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]] 1647 1647 1648 -= Create communication with**SchneiderPLC** =1975 += **Schneider** = 1649 1649 1650 1650 == **Schneider MODBUS RTU** == 1651 1651 ... ... @@ -1679,9 +1679,9 @@ 1679 1679 1680 1680 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]] 1681 1681 1682 -= Create communication withInovance** PLC**=2009 += Inovance = 1683 1683 1684 -== **H3U serial protocol** ==2011 +== **H3U serial** == 1685 1685 1686 1686 **1)V-BOX Settings** 1687 1687 ... ... @@ -1731,9 +1731,9 @@ 1731 1731 1732 1732 [[image:image-20220831164731-4.png]] 1733 1733 1734 -= Create communication withPanasonic** PLC**=2061 += Panasonic = 1735 1735 1736 -== **FP serial protocol** ==2063 +== **FP serial** == 1737 1737 1738 1738 **1)V-BOX Settings** 1739 1739 ... ... @@ -1781,9 +1781,9 @@ 1781 1781 1782 1782 [[image:image-20220831165008-1.png]] 1783 1783 1784 -= Create communication withLS** PLC**=2111 += LS = 1785 1785 1786 -== **XBC serial protocol** ==2113 +== **XBC serial** == 1787 1787 1788 1788 **1)V-BOX Settings** 1789 1789 ... ... @@ -1835,7 +1835,7 @@ 1835 1835 1836 1836 [[image:image-20220831170215-2.png]] 1837 1837 1838 -== **XGK FEnet Ethernet protocol** ==2165 +== **XGK FEnet Ethernet** == 1839 1839 1840 1840 Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 1841 1841 ... ... @@ -1878,8 +1878,76 @@ 1878 1878 1879 1879 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1880 1880 1881 -= Createcommunication with **Modbus **=2208 += INVT = 1882 1882 2210 +**1)V-BOX setting** 2211 + 2212 +|**Item**|**Settings**|**Note** 2213 +|Protocol|INVT_IVC2L| 2214 +|Connection|RS232| 2215 +|Baud rate|19200| 2216 +|Data bit|8| 2217 +|Parity|EVEN| 2218 +|Stop bit|1| 2219 +|PLC station No.|1 2220 + 2221 +**2)Address List** 2222 + 2223 + 2224 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 2225 +|(% colspan="1" rowspan="7" %)Bit|X|XOOO|0~~377| 2226 +|Y|YOOO|0~~377| 2227 +|M|MDDDD|0~~1999| 2228 +|SM|SMDDD|0~~255| 2229 +|S|SDDD|0~~991| 2230 +|T|TDDD|0~~255| 2231 +|C|CDDD|0~~255| 2232 +|(% rowspan="5" %)Word|D|DDDDD|0~~7999| 2233 +|SD|SDDDD|0~~255| 2234 +|Z|ZDD|0~~15| 2235 +|T|TDDD|0~~255| 2236 +|C|CDDD|0~~199| 2237 +|Double word|C|CDDD|200~~255| 2238 + 2239 +**3)Communication Settings** 2240 + 2241 +(% style="text-align:center" %) 2242 +[[image:盒子创建英威腾.png]] 2243 + 2244 +**4)PLC software** 2245 + 2246 +(% style="text-align:center" %) 2247 +[[image:英威腾软件.png]] 2248 + 2249 +**5)PLC setting ** 2250 + 2251 +Open the INVI plc software, create a new project or open a project that has already been created 2252 + 2253 +(% style="text-align:center" %) 2254 +[[image:英威腾创建1.png]] 2255 + 2256 +Configure serial port parameters. 2257 + 2258 +(% style="text-align:center" %) 2259 +[[image:英威腾创建2.png]] 2260 + 2261 +PC connect PLC 2262 + 2263 +(% style="text-align:center" %) 2264 +[[image:英威腾创建3.png]] 2265 + 2266 +Download 2267 + 2268 +(% style="text-align:center" %) 2269 +[[image:英威腾下载.png]] 2270 + 2271 +**6)Cable Wiring** 2272 + 2273 +(% style="text-align:center" %) 2274 +[[image:wire.png]] 2275 + 2276 += **Modbus ** = 2277 + 1883 1883 == **MODBUS RTU Slave (All function)** == 1884 1884 1885 1885 Select the protocol "Modbus RTU Slave (All Fuction)", ... ... @@ -1889,6 +1889,86 @@ 1889 1889 (% style="text-align:center" %) 1890 1890 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 1891 1891 2287 +== **Modbus Meter** == 2288 + 2289 +The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication. 2290 + 2291 +~1. Wiring the RS485 cable first. Because the pin 58 is A, the pin 59 is B for meter. Here we use the COM1 to connect. So the diagram like follows: 2292 + 2293 +(% style="text-align:center" %) 2294 +[[image:LinfeeTerminalDiagram.png]] 2295 + 2296 +2. Check the specific Modbus parameter in the communication menu from LED display. 2297 + 2298 +So from the following pictures, we can know the Meter Address is 85, Baud rate is 9600, CRC None. 2299 + 2300 +{{info}} 2301 +**✎Note: **Meter address usually corresponding to the Modbus Slave Station No. on the Modbus communication. 2302 +{{/info}} 2303 + 2304 +(% style="text-align:center" %) 2305 +[[image:MeterModbusAllView.png]] 2306 + 2307 +(% class="wikigeneratedid" %) 2308 +3. Set up the communication in the Configuration tab. 2309 + 2310 +(% class="wikigeneratedid" %) 2311 +Select the protocol as **ModBus RTU Slave (All Function)**. And set the communication parameters like below. 2312 + 2313 +(% style="text-align:center" %) 2314 +[[image:VNETCommunicationtabmeter.png]] 2315 + 2316 +(% class="wikigeneratedid" %) 2317 +4. Create new real-time monitoring tag accroding to Modbus manual 2318 + 2319 +(% class="wikigeneratedid" %) 2320 +Enter the address we want to read from the meter. The following table is intercept part of the manual for Linfee Modbus manual. 2321 + 2322 +(% class="wikigeneratedid" %) 2323 +**0x03/0x04 command data register address**: 2324 + 2325 +(% style="width:1142.22px" %) 2326 +|(% style="display:none" %) |=(% colspan="2" rowspan="1" style="width: 165px;" %)Address(% style="display:none" %) |=Description|=Data Format|=(% style="width: 254px;" %)Data Length(Word)|=(% style="width: 282px;" %)Remark 2327 +|(%%)(% style="display:none" %) (%%) HEX|(% style="width:107px" %)DEC|(%%)(% style="display:none" %) (%%) |(% style="width:100px" %) |(%%)(% style="display:none" %) (%%) |(% style="width:318px" %) 2328 +|(% style="width:107px" %)0x00|(% style="width:100px" %)0|Reserved| | |(% style="width:318px" %) 2329 +|(% style="width:107px" %)0x02|(% style="width:100px" %)2|Reserved| | |(% style="width:318px" %) 2330 +|(% style="width:107px" %)0x04|(% style="width:100px" %)4|Reserved| | |(% style="width:318px" %) 2331 +|(% style="width:107px" %)0x06|(% style="width:100px" %)6|Ua|float|2|(% style="width:318px" %)Phase Voltage data, Unit V 2332 +|(% style="width:107px" %)0x08|(% style="width:100px" %)8|Ub|float|2|(% style="width:318px" %)Phase Voltage data, Unit V 2333 +|(% style="width:107px" %)0x0A|(% style="width:100px" %)10|Uc|float|2|(% style="width:318px" %)Phase Voltage data, Unit V 2334 +|(% style="width:107px" %)0x0C|(% style="width:100px" %)12|Uab|float|2|(% style="width:318px" %)Line Voltage data, Unit V 2335 +|(% style="width:107px" %)0x0E|(% style="width:100px" %)14|Ubc|float|2|(% style="width:318px" %)Line Voltage data, Unit V 2336 +|(% style="width:107px" %)0x10|(% style="width:100px" %)16|Uca|float|2|(% style="width:318px" %)Line Voltage data, Unit V 2337 +|(% style="width:107px" %)0x12|(% style="width:100px" %)18|Ia|float|2|(% style="width:318px" %)Phase Current data, Unit A 2338 +|(% style="width:107px" %)0x14|(% style="width:100px" %)20|Ib|float|2|(% style="width:318px" %)Phase Current data, Unit A 2339 +|(% style="width:107px" %)0x16|(% style="width:100px" %)22|Ic|float|2|(% style="width:318px" %)Phase Current data, Unit A 2340 + 2341 +{{info}} 2342 +**✎Note: **We usually use the Data Type 4 for read the Modbus registers(Function Code 03) 2343 +{{/info}} 2344 + 2345 +For example, here we want to read the Phase Voltage Ua (Modbus offset 0006), the Modbus register main No. requires input decimal number, and check whether the actual address has one address offset, so the tag configured like the following screenshot: 2346 + 2347 +(% style="text-align:center" %) 2348 +[[image:VNETModbusTagSettings.png]] 2349 + 2350 +(% style="text-align:center" %) 2351 +[[image:VNETModbusTagByteSettings.png]] 2352 + 2353 +{{info}} 2354 +**✎Note: **If the read value is incorrect, please check whether need to change the Byte order. 2355 +{{/info}} 2356 + 2357 +Set the Modbus Slave Station No. 2358 + 2359 +(% style="text-align:center" %) 2360 +[[image:ModbusStationSettings.png]] 2361 + 2362 +If the communication is setup successfully, the tag will show green light. 2363 + 2364 +(% style="text-align:center" %) 2365 +[[image:Monitoringtaggreenlight.png]] 2366 + 1892 1892 == **MODBUS RTU Master** == 1893 1893 1894 1894 Select the protocol "Modbus RTU Master", ... ... @@ -1984,7 +1984,7 @@ 1984 1984 1985 1985 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]] 1986 1986 1987 -= **User define protocol** =2462 += **User define** = 1988 1988 1989 1989 More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]] 1990 1990
- 0Il1q9GZgk.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.6 KB - Content
- 1679563870401-671.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +39.3 KB - Content
- 1682233464031-639.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.9 KB - Content
- CCW.Shell_E5Cwj4tUL3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.1 KB - Content
- ControlStarCommunicate.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.0 KB - Content
- ControlStarModbus.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content
- ControlStarSystemBlock.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.3 KB - Content
- CrouzetRS232 VBox.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.9 KB - Content
- Emerson.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- Ethernet.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +45.5 KB - Content
- HollySysRS232.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.4 KB - Content
- Hollysys LM Modbus RTU.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.1 KB - Content
- Hollysys485-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.5 KB - Content
- Hollysys485box.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.4 KB - Content
- LinfeeTerminalDiagram.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.6 KB - Content
- LldwDGntf4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.3 KB - Content
- MeterModbusAddr.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +562.5 KB - Content
- MeterModbusAllView.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.6 MB - Content
- MeterModbusBaud.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +444.0 KB - Content
- MeterModbusPara.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +532.0 KB - Content
- ModbusStationSettings.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.8 KB - Content
- Monitoringtaggreenlight.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.5 KB - Content
- V-NET_Client setting.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +41.9 KB - Content
- V-NET_Client_ADD.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.4 KB - Content
- V-NET_Client_KOR0AHEA4M.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.2 KB - Content
- V-NET_Client_TIiAymnjkx.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.8 KB - Content
- V-NET_Client_TNBuqy7T5r.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.7 KB - Content
- V-NET_Client_communication.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +25.5 KB - Content
- V-NET_Client_iKKKhcgxm1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.9 KB - Content
- V-NET_Client_t2Rg2wpSoY.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +53.7 KB - Content
- VNETCommunicationtabmeter.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.0 KB - Content
- VNETModbusTagByteSettings.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.2 KB - Content
- VNETModbusTagSettings.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.7 KB - Content
- WgvjfWbQif.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.3 KB - Content
- conne ab plc.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.1 KB - Content
- export.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +115.2 KB - Content
- export1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +115.2 KB - Content
- plc 软件.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +106.8 KB - Content
- project create.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.5 KB - Content
- software.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +25.8 KB - Content
- v-net client vers.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.1 KB - Content
- wire.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +137.2 KB - Content
- 企业微信截图_16889606174191.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.7 KB - Content
- 盒子创建英威腾.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +86.5 KB - Content
- 英威腾下载.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +49.0 KB - Content
- 英威腾创建1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.7 KB - Content
- 英威腾创建2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +115.7 KB - Content
- 英威腾创建3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.6 KB - Content
- 英威腾软件.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.6 KB - Content