... ... @@ -178,102 +178,6 @@
178 178  
179 179  = Create communication with **Rockwell PLC** =
180 180  
181 -== **DF1 Advanced Protocol** ==
182 -
183 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5
184 -
185 -**1) V-Box Settings**
186 -
187 -|=Item|=Recommended |=Note
188 -|=Protocol|Allen Bradley DF1 Advanced|
189 -|=Connection|RS232|
190 -|=Baud rate|19200|
191 -|=Stop bits|1|
192 -|=Data bits|8|
193 -|=Parity|None|
194 -|=PLC Station No.|1|
195 -|=HMI Station No.|0|
196 -
197 -**2) Address List**
198 -
199 -|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note
200 -|(% colspan="1" rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1
201 -|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0
202 -|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2
203 -|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3
204 -|BN|BNddddd.dd|0.0~~99255.15|(((
205 -Bit data file B0~~B99
206 -
207 -First two digits is for file number
208 -
209 -For example, BN13001.00 represents file number B13, address 001, the 0th bit.
210 -)))
211 -|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7
212 -|NN|NNddddd.dd|0.0~~99255.15|(((
213 -Integer data file bit format N0~~N99
214 -
215 -First two digits is for file number
216 -
217 -For example, NN13001.00 represents file number N13, address 001, the 0th bit.
218 -)))
219 -|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2
220 -|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value)
221 -|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value)
222 -|TNS|TNSddddd|0~~99255|(((
223 -Timer Preset Value
224 -
225 -First two digits is for file number
226 -
227 -For example, TNS99255 represents file number T99, address 255.
228 -)))
229 -|TNP|TNPddddd|0~~99255|(((
230 -Timer Accumulator Value
231 -
232 -First two digits is for file number
233 -
234 -For example, TNP99255 represents file number T99, address 255.
235 -)))
236 -|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value)
237 -|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value)
238 -|CNS|CNSddddd|0~~99255|(((
239 -Counter Preset Value
240 -
241 -First two digits is for file number
242 -
243 -For example, CNS99255 represents file number C99, address 255.
244 -)))
245 -|CNP|CNPddddd|0~~99255|(((
246 -Counter Accumulator Value
247 -
248 -First two digits is for file number
249 -
250 -For example, CNP99255 represents file number C99, address 255.
251 -)))
252 -|N7|N7ddd|0~~255|Only able to communicate with file number N7
253 -|NN|NNddd|0~~99255|(((
254 -Integer data file
255 -
256 -First two digits is for file number
257 -
258 -For example, NN99255 represents file number N99, address 255.
259 -)))
260 -|(% colspan="1" rowspan="3" %)Double Word|F8|F8ddd|0~~255|(((
261 -Only able to communicate with file number N7
262 -)))
263 -|FN|FNddddd|0~~99255|(((
264 -Floating point data file
265 -
266 -First two digits is for file number
267 -
268 -For example, FN99255 represents file number F99, address 255.
269 -)))
270 -|LN|LNddddd|0~~99255|Long
271 -
272 -**3) Cable Wiring**
273 -
274 -(% style="text-align:center" %)
275 -[[image:ABRS232.gif]]
276 -
277 277  == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
278 278  
279 279  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
... ... @@ -281,7 +281,7 @@
281 281  **1)V-BOX setting**
282 282  
283 283  |**Item**|**Settings**|**Note**
284 -|Protocol|Allen-Bradley DF1 Advanced|
188 +|Protocol|Allen-Bradlley DF1 Advanced|
285 285  |Connection|RS232|
286 286  |Baud rate|19200|
287 287  |Data bit|8|
... ... @@ -704,86 +704,6 @@
704 704  
705 705  [[image:image-20220824162342-2.png]]
706 706  
707 -== **LOGO Ethernet Protocol** ==
708 -
709 -Supported Series: Siemens Logo 0BA0, 0BA1 series
710 -
711 -**V-BOX Settings**
712 -
713 -
714 -|**Items**|**Settings**|**Note**
715 -|Protocol|Siemens LOGO|
716 -|Connection|Ethernet|
717 -|Port No.|102|
718 -|PLC station No.|2|
719 -
720 -**Address List**
721 -
722 -
723 -|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
724 -|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
725 -|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
726 -|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
727 -|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
728 -|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
729 -|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
730 -|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
731 -|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
732 -|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
733 -|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
734 -|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
735 -|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
736 -|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
737 -|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
738 -|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
739 -
740 -**PLC Settings in LOGO Software:**
741 -
742 -Click [Tools]~-~-[Ethernet Connections],shown as below.
743 -
744 -(% style="text-align:center" %)
745 -[[image:PIStudio.12\.PLC protocols.WebHome@12.PLC Protocol_html_8b9d2322edf89519.png]]
746 -
747 -Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
748 -
749 -(% style="text-align:center" %)
750 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228142937-4.png]]
751 -
752 -**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
753 -
754 -(% style="text-align:center" %)
755 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143047-5.png]]
756 -
757 - **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
758 -
759 -(% style="text-align:center" %)
760 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143246-6.png]]
761 -
762 -**V-BOX Communication Settings**
763 -
764 -Set PLC IP in [IP Address] settings;
765 -
766 -(% style="text-align:center" %)
767 -[[image:LldwDGntf4.png]]
768 -
769 -Enable V-BOX Ethernet in [Network];
770 -
771 -(% style="text-align:center" %)
772 -[[image:WgvjfWbQif.png]]
773 -
774 -TSAP setting
775 -
776 -* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful.
777 -
778 -{{code language="LUA"}}
779 -function init.main()
780 -    addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
781 -
782 -    addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
783 -
784 -end
785 -{{/code}}
786 -
787 787  = Create communication with **Mitsubishi PLC** =
788 788  
789 789  == **FX1S,1N,2N Serial Protocol** ==
... ... @@ -1351,7 +1351,7 @@
1351 1351  
1352 1352  == **DVP Ethernet Protocol** ==
1353 1353  
1354 -Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module
1178 +Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE, DELTA DVPEN01-SL
1355 1355  
1356 1356  **1)V-BOX Settings**
1357 1357  
... ... @@ -1364,92 +1364,14 @@
1364 1364  
1365 1365  **2)Address List **
1366 1366  
1367 -|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note**
1368 -|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOO|(% style="width:225px" %)0~~377|
1369 -|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOO|(% style="width:225px" %)0~~377|
1370 -|Bit|(% style="width:191px" %)M0|(% style="width:217px" %)M0|(% style="width:168px" %)M0DDDD|(% style="width:225px" %)0~~1535|
1371 -|Bit|(% style="width:191px" %)M1|(% style="width:217px" %)M1|(% style="width:168px" %)M1DDDD|(% style="width:225px" %)1536~~4096|
1372 -|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255|
1373 -|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~255|
1374 -|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDD|(% style="width:225px" %)0~~1023|
1375 -|Word|(% style="width:191px" %)D0|(% style="width:217px" %)D0|(% style="width:168px" %)D0DDDD|(% style="width:225px" %)0~~4095|
1376 -|Word|(% style="width:191px" %)D1|(% style="width:217px" %)D1|(% style="width:168px" %)D1DDDD|(% style="width:225px" %)4096~~11999|
1377 -|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255|
1378 -|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199|
1379 -|Double Word|(% style="width:191px" %)HC|(% style="width:217px" %)HC|(% style="width:168px" %)HCDDD|(% style="width:225px" %)200~~255|
1191 +|=**Type**|=**Device registers**|=**VBox registers**|=**Format**|=**Range**|=**Note**
1192 +|Bit|X|X|X OOO|0~~377|
1193 +|Bit|Y|Y|Y OOO|0~~377|
1380 1380  
1381 -**3) PLC Setting:**
1382 -
1383 -~1. Create new project in Delta WPL Soft, and click Setting to open the communication settings:
1384 -
1385 -(% style="text-align:center" %)
1386 -[[image:DVPEthernetWPLSoft2.png]]
1387 -
1388 -2. Set up the communication type and PLC IP:
1389 -
1390 -(% style="text-align:center" %)
1391 -[[image:DVPEthernetSetup.png]]
1392 -
1393 -(% class="wikigeneratedid" %)
1394 -3. Click OK and save the settings. Then click Communication on toolbar, then click Transfer Setup to open new window:
1395 -
1396 -(% style="text-align:center" %)
1397 -[[image:DVPEthernetTransfer.png]]
1398 -
1399 -(% class="wikigeneratedid" %)
1400 -4. Select Communication Mode as PC => PLC to download or select PC <=PLC to upload:
1401 -
1402 -(% style="text-align:center" %)
1403 -[[image:DVPEthernetPLCtoPC.png]]
1404 -
1405 -5. Click Auto-Search Ethernet Module to find the PLC on the same LAN network:
1406 -
1407 -(% style="text-align:center" %)
1408 -[[image:DVPEthernetAutoSearch.png]]
1409 -
1410 -**4) V-BOX Setting:**
1411 -
1412 -Set the same IP address according to the setting from WPL Soft:
1413 -
1414 -(% style="text-align:center" %)
1415 -[[image:DVPEthernetVNETPortocol.png]]
1416 -
1417 1417  == **DVP serial protocol** ==
1418 1418  
1419 -Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX
1197 +[[Download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1420 1420  
1421 -**1)V-BOX Settings**
1422 -
1423 -|=**Items**|=**Settings**|=**Note**
1424 -|Protocol|DELTA DVP PROTOCOL|
1425 -|Connection|RS232|
1426 -|Baud Rate|9600|
1427 -|Stop Bit|1|
1428 -|Data Bit|7|
1429 -|Parity|EVEN|
1430 -|Device No.|1|
1431 -
1432 -(% class="wikigeneratedid" %)
1433 -**2)Address List**
1434 -
1435 -|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note**
1436 -|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOOOOO|(% style="width:225px" %)0~~303237|
1437 -|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOOOOO|(% style="width:225px" %)0~~303237|
1438 -|Bit|(% style="width:191px" %)M|(% style="width:217px" %)M|(% style="width:168px" %)MDDDDD|(% style="width:225px" %)0~~99999|
1439 -|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999|
1440 -|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)0~~99999|
1441 -|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDDD|(% style="width:225px" %)0~~99999|
1442 -|Word|(% style="width:191px" %)D|(% style="width:217px" %)D|(% style="width:168px" %)D DDDDD|(% style="width:225px" %)0~~99999|
1443 -|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999|
1444 -|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199|
1445 -|Double Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)200~~99999|
1446 -
1447 -(% class="wikigeneratedid" %)
1448 -**3)Wiring Diagram**
1449 -
1450 -(% style="text-align:center" %)
1451 -[[image:Delta DVP PROTOCOLSerial232.png]]
1452 -
1453 1453  == **AS Ethernet Protocol** ==
1454 1454  
1455 1455  **1)V-BOX Settings**
... ... @@ -1483,6 +1483,7 @@
1483 1483  
1484 1484  **3)Configure the communication protocol**
1485 1485  
1232 +
1486 1486  [[image:image-20220831160010-4.png]]
1487 1487  
1488 1488  **4)Cable Wiring**
... ... @@ -1941,8 +1941,8 @@
1941 1941  **address list**
1942 1942  
1943 1943  (% class="table-bordered" %)
1944 -|=(% scope="row" %)**Type**|=**Data Type**|=**Function code and description**
1945 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)
1691 +|**type**|**register**|**Function code and description**
1692 +|(% rowspan="11" %)|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)
1946 1946  |06 (write single register: write a binary value to a holding register)
1947 1947  |10 (write values to multiple addresses )
1948 1948  |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
... ... @@ -1981,7 +1981,7 @@
1981 1981  
1982 1982  **2)Address List**
1983 1983  
1984 -|=**Type**|=**Data Type**|=**Function code & Description**
1731 +|**Type**|**Register**|**Function code & Description**
1985 1985  |(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1986 1986  |06 (write single register: write a binary value to a holding register)
1987 1987  |10 (write values to multiple addresses )
0Il1q9GZgk.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -24.6 KB
Content
AB.gif
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -7.3 KB
Content
ABRS232.gif
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -7.3 KB
Content
DVPEthernetAutoSearch.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -43.6 KB
Content
DVPEthernetPLCtoPC.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -8.9 KB
Content
DVPEthernetSetup.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -19.9 KB
Content
DVPEthernetTransfer.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -59.9 KB
Content
DVPEthernetVNETPortocol.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -21.4 KB
Content
DVPEthernetWPLSoft.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -97.5 KB
Content
DVPEthernetWPLSoft2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -45.2 KB
Content
Delta DVP PROTOCOLSerial232.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -10.7 KB
Content
LldwDGntf4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -24.3 KB
Content
WgvjfWbQif.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -36.3 KB
Content