Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -706,84 +706,6 @@ 706 706 707 707 == **LOGO Ethernet Protocol** == 708 708 709 -Supported Series: Siemens Logo 0BA0, 0BA1 series 710 - 711 -**V-BOX Settings** 712 - 713 - 714 -|**Items**|**Settings**|**Note** 715 -|Protocol|Siemens LOGO| 716 -|Connection|Ethernet| 717 -|Port No.|102| 718 -|PLC station No.|2| 719 - 720 -**Address List** 721 - 722 - 723 -|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address** 724 -|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0 725 -|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000 726 -|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000 727 -|4|VW|Word|0-1468|DB1.DBX0.0|0x000000 728 -|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0 729 -|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770 730 -|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0 731 -|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180 732 -|9|AI|Word|1-16|DB1.DBX1032.0|0x002040 733 -|10|I|Bit|1-64|DB1.DBX1024.0|0x002000 734 -|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140 735 -|12|M|Bit|1-112|DB1.DBX1104.0|0x002280 736 -|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0 737 -|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70 738 -|15|V|Bit|0-14697|DB1.DBX0.0|0x000000 739 - 740 -**PLC Settings in LOGO Software:** 741 - 742 -Click [Tools]~-~-[Ethernet Connections],shown as below. 743 - 744 -(% style="text-align:center" %) 745 -[[image:PIStudio.12\.PLC protocols.WebHome@12.PLC Protocol_html_8b9d2322edf89519.png]] 746 - 747 -Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 748 - 749 -(% style="text-align:center" %) 750 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228142937-4.png]] 751 - 752 -**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 753 - 754 -(% style="text-align:center" %) 755 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143047-5.png]] 756 - 757 - **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 758 - 759 -(% style="text-align:center" %) 760 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143246-6.png]] 761 - 762 -**V-BOX Communication Settings** 763 - 764 -Set PLC IP in [IP Address] settings; 765 - 766 -(% style="text-align:center" %) 767 -[[image:LldwDGntf4.png]] 768 - 769 -Enable V-BOX Ethernet in [Network]; 770 - 771 -(% style="text-align:center" %) 772 -[[image:WgvjfWbQif.png]] 773 - 774 -TSAP setting 775 - 776 -* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful. 777 - 778 -{{code language="LUA"}} 779 -function init.main() 780 - addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address 781 - 782 - addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address 783 - 784 -end 785 -{{/code}} 786 - 787 787 = Create communication with **Mitsubishi PLC** = 788 788 789 789 == **FX1S,1N,2N Serial Protocol** ==
- 0Il1q9GZgk.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.6 KB - Content
- LldwDGntf4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.3 KB - Content
- WgvjfWbQif.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -36.3 KB - Content