... ... @@ -176,6 +176,14 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 +(% class="wikigeneratedid" %)
180 += Create communication with ABB PLC =
181 +
182 +== **AC500 Protocol** ==
183 +
184 +Support Series: ABB AC500
185 +
186 +
179 179  = Create communication with **Rockwell PLC** =
180 180  
181 181  == **DF1 Advanced Protocol** ==
... ... @@ -274,8 +274,12 @@
274 274  (% style="text-align:center" %)
275 275  [[image:ABRS232.gif]]
276 276  
277 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
285 +(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %)
286 +(% id="cke_bm_5621S" style="display:none" %)** **
278 278  
288 +== **MicroLogix Protocol** ==
289 +
290 +(% class="wikigeneratedid" %)
279 279  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
280 280  
281 281  **1)V-BOX setting**
... ... @@ -777,13 +777,24 @@
777 777  
778 778  {{code language="LUA"}}
779 779  function init.main()
780 -    addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
781 -
782 -    addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
783 -
792 +addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
793 +addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
784 784  end
785 785  {{/code}}
786 786  
797 +Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code.
798 +
799 +**✎Note:**
800 +
801 +* **Communication port configuration: **
802 +** Continuous length needs to be set to 0.
803 +** Integration interval needs to be set to 1. (no change may result in data errors)
804 +** Set Port and Device Station NO.
805 +** Other set as defaulted.
806 +* **Notes on the use of registers:**
807 +** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
808 +** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
809 +
787 787  = Create communication with **Mitsubishi PLC** =
788 788  