Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bob1 +XWiki.Hunter - Content
-
... ... @@ -176,7 +176,7 @@ 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 178 178 179 -= Create communication with **Rockwell 179 += Create communication with Allen-Bradley(**Rockwell**)** PLC** = 180 180 181 181 == **DF1 Advanced Protocol** == 182 182 ... ... @@ -274,8 +274,12 @@ 274 274 (% style="text-align:center" %) 275 275 [[image:ABRS232.gif]] 276 276 277 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 277 +(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %) 278 +(% id="cke_bm_5621S" style="display:none" %)** ** 278 278 280 +== **MicroLogix Protocol** == 281 + 282 +(% class="wikigeneratedid" %) 279 279 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 280 280 281 281 **1)V-BOX setting** ... ... @@ -515,12 +515,62 @@ 515 515 ((( 516 516 The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. 517 517 522 +== **Ethernet DF1 Protocol** == 518 518 519 -= **Allen-Bradley Ethernet DF1** = 520 - 521 521 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 522 522 526 += Create communication with **Crouzet PLC** = 523 523 528 +== **CROUZET M3 (FBD)** == 529 + 530 +**1)V-BOX setting** 531 + 532 +|=Item|=Recommended |=Note 533 +|=Protocol|CROUZET M3 (FBD)| 534 +|=Connection|RS232| 535 +|=Baud rate|115200| 536 +|=Stop bits|1| 537 +|=Data bits|7| 538 +|=Parity|EVEN| 539 + 540 +**2)Address List** 541 + 542 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note 543 +|(% rowspan="4" %)Bit|I|I DD|1~~99|Input 544 +|SLIBit|SLIBit DD.dd|1.0~~24.15|Serial Link Input 545 +|SLOBit|SLOBit DD.dd|25.0~~48.15|Serial Link Output(Read only) 546 +|State|State D|1~~1|PLC state(Read only) 547 +|(% rowspan="5" %)Word|AI|AI DD|1~~99|Analog Input 548 +|SLIn|SLIn DD|1~~24|Serial Link Input 549 +|SLOut|SLOut DD|25~~48|Serial Link Output(Read only) 550 +|Time|Time D|1~~6|((( 551 +Time1: Second 552 + 553 +Time2: Minute 554 + 555 +Time3: Hour 556 + 557 +Time4: Day 558 + 559 +Time5: Month 560 + 561 +Time6: Year 562 +))) 563 +|Order|Order D|1~~1|((( 564 +Running command(Write only) 565 + 566 +~=2: Run mode; =1: Stop mode; 567 +))) 568 + 569 +**3)Cable Wiring** 570 + 571 +(% style="text-align:center" %) 572 +[[image:CrouzetRS232 VBox.png]] 573 + 574 +{{info}} 575 +**✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details. 576 +{{/info}} 577 + 524 524 = Create communication with **Siemens PLC** = 525 525 526 526 == **S7-200 Smart Ethernet Protocol** == ... ... @@ -777,13 +777,24 @@ 777 777 778 778 {{code language="LUA"}} 779 779 function init.main() 780 - addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address 781 - 782 - addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address 783 - 834 +addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address 835 +addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address 784 784 end 785 785 {{/code}} 786 786 839 +Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 840 + 841 +**✎Note:** 842 + 843 +* **Communication port configuration: ** 844 +** Continuous length needs to be set to 0. 845 +** Integration interval needs to be set to 1. (no change may result in data errors) 846 +** Set Port and Device Station NO. 847 +** Other set as defaulted. 848 +* **Notes on the use of registers:** 849 +** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc. 850 +** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 ) 851 + 787 787 = Create communication with **Mitsubishi PLC** = 788 788 789 789 == **FX1S,1N,2N Serial Protocol** ==
- CrouzetRS232 VBox.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.9 KB - Content