Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bob1 +XWiki.Hunter - Content
-
... ... @@ -176,7 +176,7 @@ 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 178 178 179 -= Create communication with **Rockwell 179 += Create communication with Allen-Bradley(**Rockwell**)** PLC** = 180 180 181 181 == **DF1 Advanced Protocol** == 182 182 ... ... @@ -274,8 +274,12 @@ 274 274 (% style="text-align:center" %) 275 275 [[image:ABRS232.gif]] 276 276 277 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 277 +(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %) 278 +(% id="cke_bm_5621S" style="display:none" %)** ** 278 278 280 +== **MicroLogix Protocol** == 281 + 282 +(% class="wikigeneratedid" %) 279 279 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 280 280 281 281 **1)V-BOX setting** ... ... @@ -515,12 +515,62 @@ 515 515 ((( 516 516 The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. 517 517 522 +== **Ethernet DF1 Protocol** == 518 518 519 -= **Allen-Bradley Ethernet DF1** = 520 - 521 521 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 522 522 526 += Create communication with **Crouzet PLC** = 523 523 528 +== **CROUZET M3 (FBD)** == 529 + 530 +**1)V-BOX setting** 531 + 532 +|=Item|=Recommended |=Note 533 +|=Protocol|CROUZET M3 (FBD)| 534 +|=Connection|RS232| 535 +|=Baud rate|115200| 536 +|=Stop bits|1| 537 +|=Data bits|7| 538 +|=Parity|EVEN| 539 + 540 +**2)Address List** 541 + 542 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note 543 +|(% rowspan="4" %)Bit|I|I DD|1~~99|Input 544 +|SLIBit|SLIBit DD.dd|1.0~~24.15|Serial Link Input 545 +|SLOBit|SLOBit DD.dd|25.0~~48.15|Serial Link Output(Read only) 546 +|State|State D|1~~1|PLC state(Read only) 547 +|(% rowspan="5" %)Word|AI|AI DD|1~~99|Analog Input 548 +|SLIn|SLIn DD|1~~24|Serial Link Input 549 +|SLOut|SLOut DD|25~~48|Serial Link Output(Read only) 550 +|Time|Time D|1~~6|((( 551 +Time1: Second 552 + 553 +Time2: Minute 554 + 555 +Time3: Hour 556 + 557 +Time4: Day 558 + 559 +Time5: Month 560 + 561 +Time6: Year 562 +))) 563 +|Order|Order D|1~~1|((( 564 +Running command(Write only) 565 + 566 +~=2: Run mode; =1: Stop mode; 567 +))) 568 + 569 +**3)Cable Wiring** 570 + 571 +(% style="text-align:center" %) 572 +[[image:CrouzetRS232 VBox.png]] 573 + 574 +{{info}} 575 +**✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details. 576 +{{/info}} 577 + 524 524 = Create communication with **Siemens PLC** = 525 525 526 526 == **S7-200 Smart Ethernet Protocol** == ... ... @@ -786,7 +786,14 @@ 786 786 787 787 **✎Note:** 788 788 789 -* 843 +* **Communication port configuration: ** 844 +** Continuous length needs to be set to 0. 845 +** Integration interval needs to be set to 1. (no change may result in data errors) 846 +** Set Port and Device Station NO. 847 +** Other set as defaulted. 848 +* **Notes on the use of registers:** 849 +** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc. 850 +** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 ) 790 790 791 791 = Create communication with **Mitsubishi PLC** = 792 792
- CrouzetRS232 VBox.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.9 KB - Content