Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 208.1
edited by Bob
on 2023/02/02 12:00
Change comment: There is no comment for this version
To version 220.4
edited by Hunter
on 2023/03/23 11:37
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bob
1 +XWiki.Hunter
Content
... ... @@ -176,7 +176,7 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 -= Create communication with **Rockwell PLC** =
179 += Create communication with Allen-Bradley(**Rockwell**)** PLC** =
180 180  
181 181  == **DF1 Advanced Protocol** ==
182 182  
... ... @@ -274,8 +274,12 @@
274 274  (% style="text-align:center" %)
275 275  [[image:ABRS232.gif]]
276 276  
277 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
277 +(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %)
278 +(% id="cke_bm_5621S" style="display:none" %)** **
278 278  
280 +== **MicroLogix Protocol** ==
281 +
282 +(% class="wikigeneratedid" %)
279 279  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
280 280  
281 281  **1)V-BOX setting**
... ... @@ -515,12 +515,64 @@
515 515  (((
516 516  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
517 517  
522 +== **Ethernet DF1 Protocol** ==
518 518  
519 -= **Allen-Bradley Ethernet DF1** =
520 -
521 521  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
522 522  
526 += Create communication with **Crouzet PLC** =
523 523  
528 +== **CROUZET M3 (FBD)** ==
529 +
530 +Support Series: Crouzet Millenium 3 CD12/CB12
531 +
532 +**1)V-BOX setting**
533 +
534 +|=Item|=Recommended |=Note
535 +|=Protocol|CROUZET M3 (FBD)|
536 +|=Connection|RS232|
537 +|=Baud rate|115200|
538 +|=Stop bits|1|
539 +|=Data bits|7|
540 +|=Parity|EVEN|
541 +
542 +**2)Address List**
543 +
544 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note
545 +|(% rowspan="4" %)Bit|I|I DD|1~~99|Input
546 +|SLIBit|SLIBit DD.dd|1.0~~24.15|Serial Link Input
547 +|SLOBit|SLOBit DD.dd|25.0~~48.15|Serial Link Output(Read only)
548 +|State|State D|1~~1|PLC state(Read only)
549 +|(% rowspan="5" %)Word|AI|AI DD|1~~99|Analog Input
550 +|SLIn|SLIn DD|1~~24|Serial Link Input
551 +|SLOut|SLOut DD|25~~48|Serial Link Output(Read only)
552 +|Time|Time D|1~~6|(((
553 +Time1: Second
554 +
555 +Time2: Minute
556 +
557 +Time3: Hour
558 +
559 +Time4: Day
560 +
561 +Time5: Month
562 +
563 +Time6: Year
564 +)))
565 +|Order|Order D|1~~1|(((
566 +Running command(Write only)
567 +
568 +~=2: Run mode; =1: Stop mode;
569 +)))
570 +
571 +**3)Cable Wiring**
572 +
573 +(% style="text-align:center" %)
574 +[[image:CrouzetRS232 VBox.png]]
575 +
576 +{{info}}
577 +**✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details.
578 +{{/info}}
579 +
524 524  = Create communication with **Siemens PLC** =
525 525  
526 526  == **S7-200 Smart Ethernet Protocol** ==
... ... @@ -786,7 +786,14 @@
786 786  
787 787  **✎Note:**
788 788  
789 -*
845 +* **Communication port configuration: **
846 +** Continuous length needs to be set to 0.
847 +** Integration interval needs to be set to 1. (no change may result in data errors)
848 +** Set Port and Device Station NO.
849 +** Other set as defaulted.
850 +* **Notes on the use of registers:**
851 +** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
852 +** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
790 790  
791 791  = Create communication with **Mitsubishi PLC** =
792 792  
... ... @@ -1933,6 +1933,23 @@
1933 1933  (% style="text-align:center" %)
1934 1934  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
1935 1935  
1999 +== **Communicate with Modbus Meter** ==
2000 +
2001 +The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication.
2002 +
2003 +~1. Wiring the RS485 cable first. Because the pin 58 is A, the pin 59 is B for meter. Here we use the COM1 to connect. So the diagram like follows:
2004 +
2005 +(% style="text-align:center" %)
2006 +[[image:LinfeeTerminalDiagram.png]]
2007 +
2008 +2. Check the specific Modbus parameter in the communication menu from LED display.
2009 +
2010 +So from the following pictures, we can know the Meter Address is 85, Baud rate is 9600, CRC None.
2011 +
2012 +
2013 +(% style="text-align:center" %)
2014 +[[image:MeterModbusAllView.png]]
2015 +
1936 1936  == **MODBUS RTU Master** ==
1937 1937  
1938 1938  Select the protocol "Modbus RTU Master",
CrouzetRS232 VBox.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +14.9 KB
Content
LinfeeTerminalDiagram.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content
MeterModbusAddr.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +562.5 KB
Content
MeterModbusAllView.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +1.6 MB
Content
MeterModbusBaud.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +444.0 KB
Content
MeterModbusPara.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +532.0 KB
Content