Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bob
1 +XWiki.AiXia
Content
... ... @@ -1,6 +1,6 @@
1 -= Create communication with WECON PLC =
1 += WECON =
2 2  
3 -== **LX3V Serial Protocol** ==
3 +== **LX3V Serial ** ==
4 4  
5 5  Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
... ... @@ -48,7 +48,7 @@
48 48  
49 49   [[image:image-20220824120524-3.png]]
50 50  
51 -== **LX5V Serial Protocol** ==
51 +== **LX5V Serial ** ==
52 52  
53 53  This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
54 54  
... ... @@ -118,7 +118,7 @@
118 118  
119 119  The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC.
120 120  
121 -== **LX5V-N Ethernet protocol** ==
121 +== **LX5V-N Ethernet ** ==
122 122  
123 123  This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
124 124  
... ... @@ -176,9 +176,9 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 -= Create communication with **Rockwell PLC** =
179 += Allen-Bradley(**Rockwell**) =
180 180  
181 -== **DF1 Advanced Protocol** ==
181 +== **DF1 Advanced  Serial** ==
182 182  
183 183  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5
184 184  
... ... @@ -274,8 +274,12 @@
274 274  (% style="text-align:center" %)
275 275  [[image:ABRS232.gif]]
276 276  
277 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
277 +(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %)
278 +(% id="cke_bm_5621S" style="display:none" %)** **
278 278  
280 +== **MicroLogix Serial** ==
281 +
282 +(% class="wikigeneratedid" %)
279 279  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
280 280  
281 281  **1)V-BOX setting**
... ... @@ -313,7 +313,7 @@
313 313  
314 314  [[image:image-20220824110724-1.png]]
315 315  
316 -== **Micro850_FreeTag Protocol** ==
320 +== **Micro850_FreeTag Ethernet** ==
317 317  
318 318  (((
319 319  (((
... ... @@ -516,20 +516,293 @@
516 516  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
517 517  
518 518  
519 -= **Allen-Bradley Ethernet DF1** =
523 +== **Micro850_FreeTag Ethernet(new)** ==
520 520  
525 +This example introduces the establishment of Ethernet communication between Wecon V-box and 2080-LC50-48QWB,Micro850. It is introduced through three parts: PLC software configuration, V-box software configuration.
526 +
527 +(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
528 +(((
529 +**Software configuration of PLC**
530 +)))
531 +
532 +(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %)
533 +(((
534 +**1)PLC programming software:Connected Components Workbench™**
535 +
536 +(% style="text-align:center" %)
537 +[[image:software.png]]
538 +
539 +**2)New PLC project**
540 +
541 +Click New Project and select the PLC model.
542 +
543 +(% style="text-align:center" %)
544 +[[image:project create.png]]
545 +
546 +**3)Set Ethernet parameters**
547 +
548 +Follow the steps below to configure Ethernet parameters
549 +
550 +PLC IP address:192.168.39.56
551 +
552 +default gateway:192.168.39.1
553 +
554 +subnet mask:255.255.255.0
555 +
556 +(% style="text-align:center" %)
557 +[[image:Ethernet.png]]
558 +
559 +**4)connect PLC**
560 +
561 +**When downloading the setting, need to change the status of the PLC to PRG**
562 +
563 +(% style="text-align:center" %)
564 +[[image:conne ab plc.png]]
565 +
566 +**V-box software configuration**
567 +
568 +**1)V-box programming software**
569 +
570 +(% style="text-align:center" %)
571 +[[image:v-net client vers.png]]
572 +
573 +**2)Set communication port parameters**
574 +
575 +In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
576 +
577 +(% style="text-align:center" %)
578 +[[image:V-NET_Client_t2Rg2wpSoY.png]]
579 +
580 +The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
581 +
582 +(% style="text-align:center" %)
583 +[[image:V-NET_Client_communication.png]]
584 +
585 +Export variables from PLC, select CSV file, comma delimited.(% id="cke_bm_1950S" style="display:none" %)
586 +
587 +(% style="text-align:center" %)
588 +[[image:export1.png]]
589 +
590 +(% style="text-align:center" %)
591 +[[image:CCW.Shell_E5Cwj4tUL3.png]]
592 +
593 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png"]]icon add label.
594 +
595 +(% style="text-align:center" %)
596 +[[image:V-NET_Client_TNBuqy7T5r.png]]
597 +
598 +**3)Engineering production**
599 +
600 +According to your own needs, use the V-NET client software to edit the required data monitoring points.
601 +
602 +(% style="text-align:center" %)
603 +[[image:V-NET_Client_KOR0AHEA4M.png]]
604 +
605 +
606 +)))
607 +
608 +== **Ethernet DF1 Protocol** ==
609 +
521 521  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
522 522  
612 += Create communication with **Crouzet PLC** =
523 523  
524 -= Create communication with **Siemens PLC** =
614 +== **CROUZET M3 (FBD)** ==
525 525  
526 -== **S7-200 Smart Ethernet Protocol** ==
616 +Support Series: Crouzet Millenium 3 CD12/CB12
527 527  
528 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
618 +**1)V-BOX setting**
529 529  
620 +|=Item|=Recommended |=Note
621 +|=Protocol|CROUZET M3 (FBD)|
622 +|=Connection|RS232|
623 +|=Baud rate|115200|
624 +|=Stop bits|1|
625 +|=Data bits|7|
626 +|=Parity|EVEN|
530 530  
531 -== **S7-300 Ethernet Protocol** ==
628 +**2)Address List**
532 532  
630 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note
631 +|(% rowspan="4" %)Bit|I|I DD|1~~99|Input
632 +|SLIBit|SLIBit DD.dd|1.0~~24.15|Serial Link Input
633 +|SLOBit|SLOBit DD.dd|25.0~~48.15|Serial Link Output(Read only)
634 +|State|State D|1~~1|PLC state(Read only)
635 +|(% rowspan="5" %)Word|AI|AI DD|1~~99|Analog Input
636 +|SLIn|SLIn DD|1~~24|Serial Link Input
637 +|SLOut|SLOut DD|25~~48|Serial Link Output(Read only)
638 +|Time|Time D|1~~6|(((
639 +Time1: Second
640 +
641 +Time2: Minute
642 +
643 +Time3: Hour
644 +
645 +Time4: Day
646 +
647 +Time5: Month
648 +
649 +Time6: Year
650 +)))
651 +|Order|Order D|1~~1|(((
652 +Running command(Write only)
653 +
654 +~=2: Run mode; =1: Stop mode;
655 +)))
656 +
657 +**3)Cable Wiring**
658 +
659 +(% style="text-align:center" %)
660 +[[image:CrouzetRS232 VBox.png]]
661 +
662 +{{info}}
663 +**✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details.
664 +{{/info}}
665 +
666 += EMERSON =
667 +
668 += **RTU Slave ** =
669 +
670 +Supported series: EC10 series
671 +
672 +**1)V-BOX setting**
673 +
674 +|**Items**|**Settings**|**Note**
675 +|Protocol|Emerson 984 RTU Slave MODBUS|
676 +|Connection|RS485|
677 +|Baud rate|19200|
678 +|Data bit|8|
679 +|Parity|EVEN|
680 +|Stop bit|1|
681 +|Device station No.|1|Need to be same as the PLC setting
682 +
683 +(% class="wikigeneratedid" %)
684 +**2)PLC Setting**
685 +
686 +(% class="wikigeneratedid" %)
687 +Remember to use the Control Star to enable the Modbus RTU communication for port 1 in system block before dowload into PLC.
688 +
689 +(% style="text-align:center" %)
690 +[[image:ControlStarSystemBlock.png]]
691 +
692 +(% style="text-align:center" %)
693 +[[image:ControlStarCommunicate.png]]
694 +
695 +(% style="text-align:center" %)
696 +[[image:ControlStarModbus.png]]
697 +
698 +(% class="wikigeneratedid" %)
699 +**3)Address List**
700 +
701 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
702 +|(% colspan="1" rowspan="12" %)Bit|Y|YOOO|0~~377|
703 +|X|XOOO|0~~377|
704 +|M0|M0DDDD|0~~2047|
705 +|M1|M1DDDDD|2048~~10239|
706 +|SM0|SM0DDD|0~~255|
707 +|SM1|SM1DDD|256~~511|
708 +|S0|S0DDDD|0~~1023|
709 +|S1|S1DDDD|1024~~4095|
710 +|T0|T0DDD|0~~255|
711 +|T1|T1DDD|256~~511|
712 +|C0|C0DDD|0~~255|
713 +|C1|C1DDD|256~~306|
714 +|(% colspan="1" rowspan="7" %)Word|D|DDDDD|0~~7999|
715 +|Z|ZDD|0~~15|
716 +|TW0|TW0DDD|0~~255|
717 +|TW1|TW1DDD|256~~511|
718 +|SD0|SD0DDD|0~~255|
719 +|SD1|SD1DDD|256~~511|
720 +|CW|CWDDD|0~~306|
721 +|(% colspan="1" rowspan="2" %)Double Word|CW0|CW0DDD|200~~255|
722 +|CW1|CW1DDDDD|256~~99999|
723 +
724 +**4) Cable Wiring**
725 +
726 +(% style="text-align:center" %)
727 +[[image:Emerson.png]]
728 +
729 += HollySys PLC =
730 +
731 +== **LK Modbus RTU ** ==
732 +
733 +Supported Series: HollySys LK series PLC
734 +
735 +**1)V-BOX setting**
736 +
737 +|**Items**|**Settings**|**Note**
738 +|Protocol|HollySys LK Modbus RTU|
739 +|Connection|RS485|
740 +|Baud rate|38400|
741 +|Data bit|8|
742 +|Parity|None|
743 +|Stop bit|1|
744 +|Device station No.|1|
745 +
746 +**2)Address List**
747 +
748 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
749 +|Bit|QX|QXDDDDD.dd|0~~65535.15|
750 +|Bit|IX|IXDDDDD.dd|0~~65535.15|
751 +|Bit|MX|MXDDDDD.dd|0~~65535.15|
752 +|Word|QW|QWDDDDD|0~~99999|
753 +|Word|IW|IWDDDDD|0~~99999|
754 +|Word|MW|MWDDDDD|0~~99999|
755 +|Word|MD|MDDDDDD|0~~99999|
756 +
757 +**3)Cable Wiring**
758 +
759 +(% style="text-align:center" %)
760 +[[image:Hollysys485-2.png]]
761 +
762 +== **LM Modbus RTU** ==
763 +
764 +(% class="wikigeneratedid" %)
765 +Supported Series: HollySys LM3109/LM3107 PLC
766 +
767 +(% class="wikigeneratedid" %)
768 +**1)V-BOX setting**
769 +
770 +|(% style="width:208px" %)**Items**|(% style="width:310px" %)**Settings**|(% style="width:365px" %)**Optional**|(% style="width:152px" %)**Note**
771 +|(% style="width:208px" %)Protocol|(% style="width:310px" %)HollySys LM Modbus RTU|(% style="width:365px" %)HollySys LM Modbus RTU|(% style="width:152px" %)
772 +|(% style="width:208px" %)Connection|(% style="width:310px" %)RS232|(% style="width:365px" %)RS485|(% style="width:152px" %)
773 +|(% style="width:208px" %)Baud rate|(% style="width:310px" %)38400|(% style="width:365px" %)38400|(% style="width:152px" %)
774 +|(% style="width:208px" %)Data bit|(% style="width:310px" %)8|(% style="width:365px" %)8|(% style="width:152px" %)
775 +|(% style="width:208px" %)Parity|(% style="width:310px" %)None|(% style="width:365px" %)None|(% style="width:152px" %)
776 +|(% style="width:208px" %)Stop bit|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
777 +|(% style="width:208px" %)Device station No.|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
778 +
779 +**2)Address List**
780 +
781 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
782 +|Bit|QX|QXDDDDD.o|0~~99999.7|
783 +|Bit|IX|IXDDDDD.o|0~~99999.7|
784 +|Bit|MX|MXDDDDD.o|0~~99999.7|
785 +|Word|QW|QWDDDDD|0~~99999|
786 +|Word|IW|IWDDDDD|0~~99999|
787 +|Word|MW|MWDDDDD|0~~99999|
788 +|Word|MD|MDDDDDD|0~~99999|
789 +
790 +**Cable Wiring**
791 +
792 +RS232
793 +
794 +(% style="text-align:center" %)
795 +[[image:HollySysRS232.png]]
796 +
797 +RS485
798 +
799 +(% style="text-align:center" %)
800 +[[image:Hollysys LM Modbus RTU.gif]]
801 +
802 += **Siemens ** =
803 +
804 +== **S7-200 Smart Ethernet ** ==
805 +
806 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
807 +
808 +== **S7-300 Ethernet ** ==
809 +
533 533  Supported Series: Siemens S7-300 series PLC
534 534  
535 535  **1)V-BOX setting**
... ... @@ -586,11 +586,11 @@
586 586  )))
587 587  )))
588 588  
589 -== **S7-1200 Ethernet Protocol** ==
866 +== **S7-1200 Ethernet ** ==
590 590  
591 591  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
592 592  
593 -== **S7-XXX Ethernet Protocol** ==
870 +== **S7-XXX Ethernet l** ==
594 594  
595 595  Supported Series: Siemens S7-400, S7-1200 and S7-1500
596 596  
... ... @@ -704,7 +704,7 @@
704 704  
705 705  [[image:image-20220824162342-2.png]]
706 706  
707 -== **LOGO Ethernet Protocol** ==
984 +== **LOGO Ethernet ** ==
708 708  
709 709  Supported Series: Siemens Logo 0BA0, 0BA1 series
710 710  
... ... @@ -786,11 +786,18 @@
786 786  
787 787  **✎Note:**
788 788  
789 -*
1066 +* **Communication port configuration: **
1067 +** Continuous length needs to be set to 0.
1068 +** Integration interval needs to be set to 1. (no change may result in data errors)
1069 +** Set Port and Device Station NO.
1070 +** Other set as defaulted.
1071 +* **Notes on the use of registers:**
1072 +** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
1073 +** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
790 790  
791 -= Create communication with **Mitsubishi PLC** =
1075 += **Mitsubishi ** =
792 792  
793 -== **FX1S,1N,2N Serial Protocol** ==
1077 +== **FX1S,1N,2N Serial ** ==
794 794  
795 795  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
796 796  
... ... @@ -837,7 +837,7 @@
837 837  [[image:image-20220825100845-4.png]]
838 838  
839 839  
840 -== **FX3U,3G,3GA Serial Protocol** ==
1124 +== **FX3U,3G,3GA Serial ** ==
841 841  
842 842  Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
843 843  
... ... @@ -884,7 +884,7 @@
884 884  [[image:image-20220825100845-4.png]]
885 885  
886 886  
887 -== **FX3U Ethernet Protocol** ==
1171 +== **FX3U Ethernet ** ==
888 888  
889 889  Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
890 890  
... ... @@ -979,7 +979,7 @@
979 979  
980 980  [[image:image-20221119101946-2.png||height="395" width="695"]]
981 981  
982 -== **FX5U Serial Protocol** ==
1266 +== **FX5U Serial ** ==
983 983  
984 984  Mitsubishi FX5U series PLC
985 985  
... ... @@ -1061,7 +1061,7 @@
1061 1061  
1062 1062  [[image:image-20220825105533-3.png]]
1063 1063  
1064 -== **FX5U Ethernet Protocol** ==
1348 +== **FX5U Ethernet ** ==
1065 1065  
1066 1066  Mitsubishi FX5U series PLC
1067 1067  
... ... @@ -1137,7 +1137,7 @@
1137 1137  
1138 1138  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1139 1139  
1140 -== **L02 Serial Protocol** ==
1424 +== **L02 Serial ** ==
1141 1141  
1142 1142  Mitsubishi L02 series CPU built-in serial port.
1143 1143  
... ... @@ -1197,7 +1197,7 @@
1197 1197  
1198 1198  [[image:image-20220825160820-4.png]]
1199 1199  
1200 -== **L02 Ethernet Protocol** ==
1484 +== **L02 Ethernet ** ==
1201 1201  
1202 1202  Mitsubishi L series CPU built-in Ethernet port.
1203 1203  
... ... @@ -1270,13 +1270,13 @@
1270 1270  
1271 1271  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1272 1272  
1273 -== **Q12H Serial Protocol** ==
1557 +== **Q12H Serial ** ==
1274 1274  
1275 1275  This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
1276 1276  
1277 1277  [[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]
1278 1278  
1279 -== **QJ71E71 Ethernet Protocol** ==
1563 +== **QJ71E71 Ethernet ** ==
1280 1280  
1281 1281  Mitsubishi QJ71E71 Ethernet communication module;
1282 1282  
... ... @@ -1351,9 +1351,9 @@
1351 1351  
1352 1352  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
1353 1353  
1354 -= Create communication with **Delta PLC** =
1638 += **Delta** =
1355 1355  
1356 -== **DVP Ethernet Protocol** ==
1640 +== **DVP Ethernet** ==
1357 1357  
1358 1358  Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module
1359 1359  
... ... @@ -1418,7 +1418,7 @@
1418 1418  (% style="text-align:center" %)
1419 1419  [[image:DVPEthernetVNETPortocol.png]]
1420 1420  
1421 -== **DVP serial protocol** ==
1705 +== **DVP serial** ==
1422 1422  
1423 1423  Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX
1424 1424  
... ... @@ -1454,7 +1454,7 @@
1454 1454  (% style="text-align:center" %)
1455 1455  [[image:Delta DVP PROTOCOLSerial232.png]]
1456 1456  
1457 -== **AS Ethernet Protocol** ==
1741 +== **AS Ethernet** ==
1458 1458  
1459 1459  **1)V-BOX Settings**
1460 1460  
... ... @@ -1499,19 +1499,18 @@
1499 1499  
1500 1500  [[image:image-20220831155157-3.png]]
1501 1501  
1502 -= Create communication with **Omron PLC** =
1786 += **Omron** =
1503 1503  
1504 -== **CP1 Series Protocol ** ==
1788 +== **CP1 Series** ==
1505 1505  
1506 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1790 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1507 1507  
1508 -== **CP2M Series Protocol** ==
1792 +== **CP2M Series** ==
1509 1509  
1510 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1794 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1511 1511  
1796 +== **EC55 Series ** ==
1512 1512  
1513 -== **EC55 Series Protocol** ==
1514 -
1515 1515  Supported device: EC55 temperature instrument
1516 1516  
1517 1517  **1)V-BOX Settings**
... ... @@ -1571,9 +1571,9 @@
1571 1571  * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1572 1572  * [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1573 1573  
1574 -= Create communication with Xinje** PLC** =
1857 += Xinje =
1575 1575  
1576 -== **XC serial protocol** ==
1859 +== **XC serial** ==
1577 1577  
1578 1578  **1)V-BOX Settings**
1579 1579  
... ... @@ -1615,7 +1615,7 @@
1615 1615  
1616 1616  [[image:image-20220831163441-4.png]]
1617 1617  
1618 -== **XD serial protocol** ==
1901 +== **XD serial** ==
1619 1619  
1620 1620  **1)V-BOX Settings**
1621 1621  
... ... @@ -1689,7 +1689,7 @@
1689 1689  
1690 1690  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1691 1691  
1692 -= Create communication with **Schneider PLC** =
1975 += **Schneider** =
1693 1693  
1694 1694  == **Schneider MODBUS RTU** ==
1695 1695  
... ... @@ -1723,7 +1723,7 @@
1723 1723  
1724 1724  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
1725 1725  
1726 -= Create communication with Inovance** PLC** =
2009 += Inovance =
1727 1727  
1728 1728  == **H3U serial protocol** ==
1729 1729  
... ... @@ -1775,9 +1775,9 @@
1775 1775  
1776 1776  [[image:image-20220831164731-4.png]]
1777 1777  
1778 -= Create communication with Panasonic** PLC** =
2061 += Panasonic =
1779 1779  
1780 -== **FP serial protocol** ==
2063 +== **FP serial** ==
1781 1781  
1782 1782  **1)V-BOX Settings**
1783 1783  
... ... @@ -1825,9 +1825,9 @@
1825 1825  
1826 1826  [[image:image-20220831165008-1.png]]
1827 1827  
1828 -= Create communication with LS** PLC** =
2111 += LS =
1829 1829  
1830 -== **XBC serial protocol** ==
2113 +== **XBC serial** ==
1831 1831  
1832 1832  **1)V-BOX Settings**
1833 1833  
... ... @@ -1879,7 +1879,7 @@
1879 1879  
1880 1880  [[image:image-20220831170215-2.png]]
1881 1881  
1882 -== **XGK FEnet Ethernet protocol** ==
2165 +== **XGK FEnet Ethernet** ==
1883 1883  
1884 1884  Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1885 1885  
... ... @@ -1922,8 +1922,76 @@
1922 1922  
1923 1923  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1924 1924  
1925 -= Create communication with **Modbus ** =
2208 += INVT =
1926 1926  
2210 +**1)V-BOX setting**
2211 +
2212 +|**Item**|**Settings**|**Note**
2213 +|Protocol|INVT_IVC2L|
2214 +|Connection|RS232|
2215 +|Baud rate|19200|
2216 +|Data bit|8|
2217 +|Parity|EVEN|
2218 +|Stop bit|1|
2219 +|PLC station No.|1
2220 +
2221 +**2)Address List**
2222 +
2223 +
2224 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
2225 +|(% colspan="1" rowspan="7" %)Bit|X|XOOO|0~~377|
2226 +|Y|YOOO|0~~377|
2227 +|M|MDDDD|0~~1999|
2228 +|SM|SMDDD|0~~255|
2229 +|S|SDDD|0~~991|
2230 +|T|TDDD|0~~255|
2231 +|C|CDDD|0~~255|
2232 +|(% rowspan="5" %)Word|D|DDDDD|0~~7999|
2233 +|SD|SDDDD|0~~255|
2234 +|Z|ZDD|0~~15|
2235 +|T|TDDD|0~~255|
2236 +|C|CDDD|0~~199|
2237 +|Double word|C|CDDD|200~~255|
2238 +
2239 +**3)Communication Settings**
2240 +
2241 +(% style="text-align:center" %)
2242 +[[image:盒子创建英威腾.png]]
2243 +
2244 +**4)PLC software**
2245 +
2246 +(% style="text-align:center" %)
2247 +[[image:英威腾软件.png]]
2248 +
2249 +**5)PLC setting **
2250 +
2251 +Open the INVI plc software, create a new project or open a project that has already been created
2252 +
2253 +(% style="text-align:center" %)
2254 +[[image:英威腾创建1.png]]
2255 +
2256 +Configure serial port parameters.
2257 +
2258 +(% style="text-align:center" %)
2259 +[[image:英威腾创建2.png]]
2260 +
2261 +PC connect PLC
2262 +
2263 +(% style="text-align:center" %)
2264 +[[image:英威腾创建3.png]]
2265 +
2266 +Download
2267 +
2268 +(% style="text-align:center" %)
2269 +[[image:英威腾下载.png]]
2270 +
2271 +**6)Cable Wiring**
2272 +
2273 +(% style="text-align:center" %)
2274 +[[image:wire.png]]
2275 +
2276 += **Modbus ** =
2277 +
1927 1927  == **MODBUS RTU Slave (All function)** ==
1928 1928  
1929 1929  Select the protocol "Modbus RTU Slave (All Fuction)",
... ... @@ -1933,6 +1933,86 @@
1933 1933  (% style="text-align:center" %)
1934 1934  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
1935 1935  
2287 +== **Modbus Meter** ==
2288 +
2289 +The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication.
2290 +
2291 +~1. Wiring the RS485 cable first. Because the pin 58 is A, the pin 59 is B for meter. Here we use the COM1 to connect. So the diagram like follows:
2292 +
2293 +(% style="text-align:center" %)
2294 +[[image:LinfeeTerminalDiagram.png]]
2295 +
2296 +2. Check the specific Modbus parameter in the communication menu from LED display.
2297 +
2298 +So from the following pictures, we can know the Meter Address is 85, Baud rate is 9600, CRC None.
2299 +
2300 +{{info}}
2301 +**✎Note: **Meter address usually corresponding to the Modbus Slave Station No. on the Modbus communication.
2302 +{{/info}}
2303 +
2304 +(% style="text-align:center" %)
2305 +[[image:MeterModbusAllView.png]]
2306 +
2307 +(% class="wikigeneratedid" %)
2308 +3. Set up the communication in the Configuration tab.
2309 +
2310 +(% class="wikigeneratedid" %)
2311 +Select the protocol as **ModBus RTU Slave (All Function)**. And set the communication parameters like below.
2312 +
2313 +(% style="text-align:center" %)
2314 +[[image:VNETCommunicationtabmeter.png]]
2315 +
2316 +(% class="wikigeneratedid" %)
2317 +4. Create new real-time monitoring tag accroding to Modbus manual
2318 +
2319 +(% class="wikigeneratedid" %)
2320 +Enter the address we want to read from the meter. The following table is intercept part of the manual for Linfee Modbus manual.
2321 +
2322 +(% class="wikigeneratedid" %)
2323 +**0x03/0x04 command data register address**:
2324 +
2325 +(% style="width:1142.22px" %)
2326 +|(% style="display:none" %) |=(% colspan="2" rowspan="1" style="width: 165px;" %)Address(% style="display:none" %) |=Description|=Data Format|=(% style="width: 254px;" %)Data Length(Word)|=(% style="width: 282px;" %)Remark
2327 +|(%%)(% style="display:none" %) (%%) HEX|(% style="width:107px" %)DEC|(%%)(% style="display:none" %) (%%) |(% style="width:100px" %) |(%%)(% style="display:none" %) (%%) |(% style="width:318px" %)
2328 +|(% style="width:107px" %)0x00|(% style="width:100px" %)0|Reserved| | |(% style="width:318px" %)
2329 +|(% style="width:107px" %)0x02|(% style="width:100px" %)2|Reserved| | |(% style="width:318px" %)
2330 +|(% style="width:107px" %)0x04|(% style="width:100px" %)4|Reserved| | |(% style="width:318px" %)
2331 +|(% style="width:107px" %)0x06|(% style="width:100px" %)6|Ua|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2332 +|(% style="width:107px" %)0x08|(% style="width:100px" %)8|Ub|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2333 +|(% style="width:107px" %)0x0A|(% style="width:100px" %)10|Uc|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2334 +|(% style="width:107px" %)0x0C|(% style="width:100px" %)12|Uab|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2335 +|(% style="width:107px" %)0x0E|(% style="width:100px" %)14|Ubc|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2336 +|(% style="width:107px" %)0x10|(% style="width:100px" %)16|Uca|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2337 +|(% style="width:107px" %)0x12|(% style="width:100px" %)18|Ia|float|2|(% style="width:318px" %)Phase Current data, Unit A
2338 +|(% style="width:107px" %)0x14|(% style="width:100px" %)20|Ib|float|2|(% style="width:318px" %)Phase Current data, Unit A
2339 +|(% style="width:107px" %)0x16|(% style="width:100px" %)22|Ic|float|2|(% style="width:318px" %)Phase Current data, Unit A
2340 +
2341 +{{info}}
2342 +**✎Note: **We usually use the Data Type 4 for read the Modbus registers(Function Code 03)
2343 +{{/info}}
2344 +
2345 +For example, here we want to read the Phase Voltage Ua (Modbus offset 0006), the Modbus register main No. requires input decimal number, and check whether the actual address has one address offset, so the tag configured like the following screenshot:
2346 +
2347 +(% style="text-align:center" %)
2348 +[[image:VNETModbusTagSettings.png]]
2349 +
2350 +(% style="text-align:center" %)
2351 +[[image:VNETModbusTagByteSettings.png]]
2352 +
2353 +{{info}}
2354 +**✎Note: **If the read value is incorrect, please check whether need to change the Byte order.
2355 +{{/info}}
2356 +
2357 +Set the Modbus Slave Station No.
2358 +
2359 +(% style="text-align:center" %)
2360 +[[image:ModbusStationSettings.png]]
2361 +
2362 +If the communication is setup successfully, the tag will show green light.
2363 +
2364 +(% style="text-align:center" %)
2365 +[[image:Monitoringtaggreenlight.png]]
2366 +
1936 1936  == **MODBUS RTU Master** ==
1937 1937  
1938 1938  Select the protocol "Modbus RTU Master",
1679563870401-671.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +39.3 KB
Content
1682233464031-639.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +15.9 KB
Content
CCW.Shell_E5Cwj4tUL3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +27.1 KB
Content
ControlStarCommunicate.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +26.0 KB
Content
ControlStarModbus.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content
ControlStarSystemBlock.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +46.3 KB
Content
CrouzetRS232 VBox.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +14.9 KB
Content
Emerson.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
Ethernet.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +45.5 KB
Content
HollySysRS232.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +10.4 KB
Content
Hollysys LM Modbus RTU.gif
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.1 KB
Content
Hollysys485-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.5 KB
Content
Hollysys485box.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.4 KB
Content
LinfeeTerminalDiagram.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content
MeterModbusAddr.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +562.5 KB
Content
MeterModbusAllView.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +1.6 MB
Content
MeterModbusBaud.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +444.0 KB
Content
MeterModbusPara.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +532.0 KB
Content
ModbusStationSettings.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +35.8 KB
Content
Monitoringtaggreenlight.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.5 KB
Content
V-NET_Client setting.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +41.9 KB
Content
V-NET_Client_ADD.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +51.4 KB
Content
V-NET_Client_KOR0AHEA4M.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +14.2 KB
Content
V-NET_Client_TIiAymnjkx.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +12.8 KB
Content
V-NET_Client_TNBuqy7T5r.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +26.7 KB
Content
V-NET_Client_communication.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +25.5 KB
Content
V-NET_Client_iKKKhcgxm1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +35.9 KB
Content
V-NET_Client_t2Rg2wpSoY.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +53.7 KB
Content
VNETCommunicationtabmeter.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +31.0 KB
Content
VNETModbusTagByteSettings.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +31.2 KB
Content
VNETModbusTagSettings.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +35.7 KB
Content
conne ab plc.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +43.1 KB
Content
export.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +115.2 KB
Content
export1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +115.2 KB
Content
plc 软件.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +106.8 KB
Content
project create.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +65.5 KB
Content
software.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +25.8 KB
Content
v-net client vers.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +13.1 KB
Content
wire.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +137.2 KB
Content
企业微信截图_16889606174191.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +20.7 KB
Content
盒子创建英威腾.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +86.5 KB
Content
英威腾下载.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +49.0 KB
Content
英威腾创建1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +36.7 KB
Content
英威腾创建2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +115.7 KB
Content
英威腾创建3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +76.6 KB
Content
英威腾软件.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +52.6 KB
Content