Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 209.1
edited by Bob
on 2023/02/02 13:55
Change comment: There is no comment for this version
To version 200.1
edited by Bob
on 2022/12/17 14:40
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -178,102 +178,6 @@
178 178  
179 179  = Create communication with **Rockwell PLC** =
180 180  
181 -== **DF1 Advanced Protocol** ==
182 -
183 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5
184 -
185 -**1) V-Box Settings**
186 -
187 -|=Item|=Recommended |=Note
188 -|=Protocol|Allen Bradley DF1 Advanced|
189 -|=Connection|RS232|
190 -|=Baud rate|19200|
191 -|=Stop bits|1|
192 -|=Data bits|8|
193 -|=Parity|None|
194 -|=PLC Station No.|1|
195 -|=HMI Station No.|0|
196 -
197 -**2) Address List**
198 -
199 -|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note
200 -|(% colspan="1" rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1
201 -|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0
202 -|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2
203 -|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3
204 -|BN|BNddddd.dd|0.0~~99255.15|(((
205 -Bit data file B0~~B99
206 -
207 -First two digits is for file number
208 -
209 -For example, BN13001.00 represents file number B13, address 001, the 0th bit.
210 -)))
211 -|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7
212 -|NN|NNddddd.dd|0.0~~99255.15|(((
213 -Integer data file bit format N0~~N99
214 -
215 -First two digits is for file number
216 -
217 -For example, NN13001.00 represents file number N13, address 001, the 0th bit.
218 -)))
219 -|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2
220 -|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value)
221 -|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value)
222 -|TNS|TNSddddd|0~~99255|(((
223 -Timer Preset Value
224 -
225 -First two digits is for file number
226 -
227 -For example, TNS99255 represents file number T99, address 255.
228 -)))
229 -|TNP|TNPddddd|0~~99255|(((
230 -Timer Accumulator Value
231 -
232 -First two digits is for file number
233 -
234 -For example, TNP99255 represents file number T99, address 255.
235 -)))
236 -|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value)
237 -|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value)
238 -|CNS|CNSddddd|0~~99255|(((
239 -Counter Preset Value
240 -
241 -First two digits is for file number
242 -
243 -For example, CNS99255 represents file number C99, address 255.
244 -)))
245 -|CNP|CNPddddd|0~~99255|(((
246 -Counter Accumulator Value
247 -
248 -First two digits is for file number
249 -
250 -For example, CNP99255 represents file number C99, address 255.
251 -)))
252 -|N7|N7ddd|0~~255|Only able to communicate with file number N7
253 -|NN|NNddd|0~~99255|(((
254 -Integer data file
255 -
256 -First two digits is for file number
257 -
258 -For example, NN99255 represents file number N99, address 255.
259 -)))
260 -|(% colspan="1" rowspan="3" %)Double Word|F8|F8ddd|0~~255|(((
261 -Only able to communicate with file number N7
262 -)))
263 -|FN|FNddddd|0~~99255|(((
264 -Floating point data file
265 -
266 -First two digits is for file number
267 -
268 -For example, FN99255 represents file number F99, address 255.
269 -)))
270 -|LN|LNddddd|0~~99255|Long
271 -
272 -**3) Cable Wiring**
273 -
274 -(% style="text-align:center" %)
275 -[[image:ABRS232.gif]]
276 -
277 277  == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
278 278  
279 279  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
... ... @@ -281,7 +281,7 @@
281 281  **1)V-BOX setting**
282 282  
283 283  |**Item**|**Settings**|**Note**
284 -|Protocol|Allen-Bradley DF1 Advanced|
188 +|Protocol|Allen-Bradlley DF1 Advanced|
285 285  |Connection|RS232|
286 286  |Baud rate|19200|
287 287  |Data bit|8|
... ... @@ -704,99 +704,6 @@
704 704  
705 705  [[image:image-20220824162342-2.png]]
706 706  
707 -== **LOGO Ethernet Protocol** ==
708 -
709 -Supported Series: Siemens Logo 0BA0, 0BA1 series
710 -
711 -**V-BOX Settings**
712 -
713 -
714 -|**Items**|**Settings**|**Note**
715 -|Protocol|Siemens LOGO|
716 -|Connection|Ethernet|
717 -|Port No.|102|
718 -|PLC station No.|2|
719 -
720 -**Address List**
721 -
722 -
723 -|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
724 -|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
725 -|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
726 -|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
727 -|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
728 -|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
729 -|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
730 -|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
731 -|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
732 -|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
733 -|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
734 -|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
735 -|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
736 -|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
737 -|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
738 -|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
739 -
740 -**PLC Settings in LOGO Software:**
741 -
742 -Click [Tools]~-~-[Ethernet Connections],shown as below.
743 -
744 -(% style="text-align:center" %)
745 -[[image:PIStudio.12\.PLC protocols.WebHome@12.PLC Protocol_html_8b9d2322edf89519.png]]
746 -
747 -Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
748 -
749 -(% style="text-align:center" %)
750 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228142937-4.png]]
751 -
752 -**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
753 -
754 -(% style="text-align:center" %)
755 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143047-5.png]]
756 -
757 - **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
758 -
759 -(% style="text-align:center" %)
760 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143246-6.png]]
761 -
762 -**V-BOX Communication Settings**
763 -
764 -Set PLC IP in [IP Address] settings;
765 -
766 -(% style="text-align:center" %)
767 -[[image:LldwDGntf4.png]]
768 -
769 -Enable V-BOX Ethernet in [Network];
770 -
771 -(% style="text-align:center" %)
772 -[[image:WgvjfWbQif.png]]
773 -
774 -TSAP setting
775 -
776 -* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful.
777 -
778 -{{code language="LUA"}}
779 -function init.main()
780 -addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
781 -addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
782 -end
783 -{{/code}}
784 -
785 -Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code.
786 -
787 -**✎Note:**
788 -
789 -* **Communication port configuration: **
790 -** Continuous length needs to be set to 0.
791 -** Integration interval needs to be set to 1. (no change may result in data errors)
792 -** Set Port and Device Station NO.
793 -** Other set as defaulted.
794 -* **Notes on the use of registers:**
795 -** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
796 -** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
797 -
798 -
799 -
800 800  = Create communication with **Mitsubishi PLC** =
801 801  
802 802  == **FX1S,1N,2N Serial Protocol** ==
0Il1q9GZgk.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -24.6 KB
Content
AB.gif
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -7.3 KB
Content
ABRS232.gif
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -7.3 KB
Content
LldwDGntf4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -24.3 KB
Content
WgvjfWbQif.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -36.3 KB
Content