Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -176,7 +176,7 @@ 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 178 178 179 -= Create communication with **Rockwell 179 += Create communication with Allen-Bradley(**Rockwell**)** PLC** = 180 180 181 181 == **DF1 Advanced Protocol** == 182 182 ... ... @@ -277,8 +277,7 @@ 277 277 (% class="wikigeneratedid" id="HMicroLogixA0Protocol" %) 278 278 (% id="cke_bm_5621S" style="display:none" %)** ** 279 279 280 -(% class="wikigeneratedid" %) 281 -**MicroLogix Protocol** 280 +== **MicroLogix Protocol** == 282 282 283 283 (% class="wikigeneratedid" %) 284 284 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 ... ... @@ -520,12 +520,64 @@ 520 520 ((( 521 521 The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. 522 522 522 +== **Ethernet DF1 Protocol** == 523 523 524 -= **Allen-Bradley Ethernet DF1** = 525 - 526 526 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 527 527 526 += Create communication with **Crouzet PLC** = 528 528 528 +== **CROUZET M3 (FBD)** == 529 + 530 +Support Series: Crouzet Millenium 3 CD12/CB12 531 + 532 +**1)V-BOX setting** 533 + 534 +|=Item|=Recommended |=Note 535 +|=Protocol|CROUZET M3 (FBD)| 536 +|=Connection|RS232| 537 +|=Baud rate|115200| 538 +|=Stop bits|1| 539 +|=Data bits|7| 540 +|=Parity|EVEN| 541 + 542 +**2)Address List** 543 + 544 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note 545 +|(% rowspan="4" %)Bit|I|I DD|1~~99|Input 546 +|SLIBit|SLIBit DD.dd|1.0~~24.15|Serial Link Input 547 +|SLOBit|SLOBit DD.dd|25.0~~48.15|Serial Link Output(Read only) 548 +|State|State D|1~~1|PLC state(Read only) 549 +|(% rowspan="5" %)Word|AI|AI DD|1~~99|Analog Input 550 +|SLIn|SLIn DD|1~~24|Serial Link Input 551 +|SLOut|SLOut DD|25~~48|Serial Link Output(Read only) 552 +|Time|Time D|1~~6|((( 553 +Time1: Second 554 + 555 +Time2: Minute 556 + 557 +Time3: Hour 558 + 559 +Time4: Day 560 + 561 +Time5: Month 562 + 563 +Time6: Year 564 +))) 565 +|Order|Order D|1~~1|((( 566 +Running command(Write only) 567 + 568 +~=2: Run mode; =1: Stop mode; 569 +))) 570 + 571 +**3)Cable Wiring** 572 + 573 +(% style="text-align:center" %) 574 +[[image:CrouzetRS232 VBox.png]] 575 + 576 +{{info}} 577 +**✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details. 578 +{{/info}} 579 + 529 529 = Create communication with **Siemens PLC** = 530 530 531 531 == **S7-200 Smart Ethernet Protocol** == ... ... @@ -800,7 +800,6 @@ 800 800 ** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc. 801 801 ** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 ) 802 802 803 - 804 804 = Create communication with **Mitsubishi PLC** = 805 805 806 806 == **FX1S,1N,2N Serial Protocol** ==
- CrouzetRS232 VBox.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.9 KB - Content