Changes for page 1 Communication

Last modified by xingzhi lin on 2025/08/01 15:25

From version 211.1
edited by Hunter
on 2023/02/04 11:14
Change comment: There is no comment for this version
To version 258.1
edited by Theodore Xu
on 2023/08/23 19:34
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.AiXia
Content
... ... @@ -1,6 +1,6 @@
1 -= Create communication with WECON PLC =
1 += WECON =
2 2  
3 -== **LX3V Serial Protocol** ==
3 +== **LX3V Serial ** ==
4 4  
5 5  Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
... ... @@ -48,7 +48,7 @@
48 48  
49 49   [[image:image-20220824120524-3.png]]
50 50  
51 -== **LX5V Serial Protocol** ==
51 +== **LX5V Serial ** ==
52 52  
53 53  This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
54 54  
... ... @@ -118,7 +118,7 @@
118 118  
119 119  The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC.
120 120  
121 -== **LX5V-N Ethernet protocol** ==
121 +== **LX5V-N Ethernet ** ==
122 122  
123 123  This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
124 124  
... ... @@ -176,9 +176,9 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 -= Create communication with **Rockwell PLC** =
179 += Allen-Bradley(**Rockwell**) =
180 180  
181 -== **DF1 Advanced Protocol** ==
181 +== **DF1 Advanced  Serial** ==
182 182  
183 183  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5
184 184  
... ... @@ -277,8 +277,7 @@
277 277  (% class="wikigeneratedid" id="HMicroLogixA0Protocol" %)
278 278  (% id="cke_bm_5621S" style="display:none" %)** **
279 279  
280 -(% class="wikigeneratedid" %)
281 -== **MicroLogix Protocol** ==
280 +== **MicroLogix Serial** ==
282 282  
283 283  (% class="wikigeneratedid" %)
284 284  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
... ... @@ -318,7 +318,7 @@
318 318  
319 319  [[image:image-20220824110724-1.png]]
320 320  
321 -== **Micro850_FreeTag Protocol** ==
320 +== **Micro850_FreeTag Ethernet** ==
322 322  
323 323  (((
324 324  (((
... ... @@ -521,20 +521,293 @@
521 521  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
522 522  
523 523  
524 -= **Allen-Bradley Ethernet DF1** =
523 +== **Micro850_FreeTag Ethernet(new)** ==
525 525  
525 +This example introduces the establishment of Ethernet communication between Wecon V-box and 2080-LC50-48QWB,Micro850. It is introduced through three parts: PLC software configuration, V-box software configuration.
526 +
527 +(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
528 +(((
529 +**Software configuration of PLC**
530 +)))
531 +
532 +(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %)
533 +(((
534 +**1)PLC programming software:Connected Components Workbench™**
535 +
536 +(% style="text-align:center" %)
537 +[[image:software.png]]
538 +
539 +**2)New PLC project**
540 +
541 +Click New Project and select the PLC model.
542 +
543 +(% style="text-align:center" %)
544 +[[image:project create.png]]
545 +
546 +**3)Set Ethernet parameters**
547 +
548 +Follow the steps below to configure Ethernet parameters
549 +
550 +PLC IP address:192.168.39.56
551 +
552 +default gateway:192.168.39.1
553 +
554 +subnet mask:255.255.255.0
555 +
556 +(% style="text-align:center" %)
557 +[[image:Ethernet.png]]
558 +
559 +**4)connect PLC**
560 +
561 +**When downloading the setting, need to change the status of the PLC to PRG**
562 +
563 +(% style="text-align:center" %)
564 +[[image:conne ab plc.png]]
565 +
566 +**V-box software configuration**
567 +
568 +**1)V-box programming software**
569 +
570 +(% style="text-align:center" %)
571 +[[image:v-net client vers.png]]
572 +
573 +**2)Set communication port parameters**
574 +
575 +In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
576 +
577 +(% style="text-align:center" %)
578 +[[image:V-NET_Client_t2Rg2wpSoY.png]]
579 +
580 +The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
581 +
582 +(% style="text-align:center" %)
583 +[[image:V-NET_Client_communication.png]]
584 +
585 +Export variables from PLC, select CSV file, comma delimited.(% id="cke_bm_1950S" style="display:none" %)
586 +
587 +(% style="text-align:center" %)
588 +[[image:export1.png]]
589 +
590 +(% style="text-align:center" %)
591 +[[image:CCW.Shell_E5Cwj4tUL3.png]]
592 +
593 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png"]]icon add label.
594 +
595 +(% style="text-align:center" %)
596 +[[image:V-NET_Client_TNBuqy7T5r.png]]
597 +
598 +**3)Engineering production**
599 +
600 +According to your own needs, use the V-NET client software to edit the required data monitoring points.
601 +
602 +(% style="text-align:center" %)
603 +[[image:V-NET_Client_KOR0AHEA4M.png]]
604 +
605 +
606 +)))
607 +
608 +== **Ethernet DF1** ==
609 +
526 526  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
527 527  
612 += **Crouzet PLC** =
528 528  
529 -= Create communication with **Siemens PLC** =
614 +== **CROUZET M3 (FBD) Serial** ==
530 530  
531 -== **S7-200 Smart Ethernet Protocol** ==
616 +Support Series: Crouzet Millenium 3 CD12/CB12
532 532  
533 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
618 +**1)V-BOX setting**
534 534  
620 +|=Item|=Recommended |=Note
621 +|=Protocol|CROUZET M3 (FBD)|
622 +|=Connection|RS232|
623 +|=Baud rate|115200|
624 +|=Stop bits|1|
625 +|=Data bits|7|
626 +|=Parity|EVEN|
535 535  
536 -== **S7-300 Ethernet Protocol** ==
628 +**2)Address List**
537 537  
630 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note
631 +|(% rowspan="4" %)Bit|I|I DD|1~~99|Input
632 +|SLIBit|SLIBit DD.dd|1.0~~24.15|Serial Link Input
633 +|SLOBit|SLOBit DD.dd|25.0~~48.15|Serial Link Output(Read only)
634 +|State|State D|1~~1|PLC state(Read only)
635 +|(% rowspan="5" %)Word|AI|AI DD|1~~99|Analog Input
636 +|SLIn|SLIn DD|1~~24|Serial Link Input
637 +|SLOut|SLOut DD|25~~48|Serial Link Output(Read only)
638 +|Time|Time D|1~~6|(((
639 +Time1: Second
640 +
641 +Time2: Minute
642 +
643 +Time3: Hour
644 +
645 +Time4: Day
646 +
647 +Time5: Month
648 +
649 +Time6: Year
650 +)))
651 +|Order|Order D|1~~1|(((
652 +Running command(Write only)
653 +
654 +~=2: Run mode; =1: Stop mode;
655 +)))
656 +
657 +**3)Cable Wiring**
658 +
659 +(% style="text-align:center" %)
660 +[[image:CrouzetRS232 VBox.png]]
661 +
662 +{{info}}
663 +**✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details.
664 +{{/info}}
665 +
666 += EMERSON =
667 +
668 += **RTU Slave ** =
669 +
670 +Supported series: EC10 series
671 +
672 +**1)V-BOX setting**
673 +
674 +|**Items**|**Settings**|**Note**
675 +|Protocol|Emerson 984 RTU Slave MODBUS|
676 +|Connection|RS485|
677 +|Baud rate|19200|
678 +|Data bit|8|
679 +|Parity|EVEN|
680 +|Stop bit|1|
681 +|Device station No.|1|Need to be same as the PLC setting
682 +
683 +(% class="wikigeneratedid" %)
684 +**2)PLC Setting**
685 +
686 +(% class="wikigeneratedid" %)
687 +Remember to use the Control Star to enable the Modbus RTU communication for port 1 in system block before dowload into PLC.
688 +
689 +(% style="text-align:center" %)
690 +[[image:ControlStarSystemBlock.png]]
691 +
692 +(% style="text-align:center" %)
693 +[[image:ControlStarCommunicate.png]]
694 +
695 +(% style="text-align:center" %)
696 +[[image:ControlStarModbus.png]]
697 +
698 +(% class="wikigeneratedid" %)
699 +**3)Address List**
700 +
701 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
702 +|(% colspan="1" rowspan="12" %)Bit|Y|YOOO|0~~377|
703 +|X|XOOO|0~~377|
704 +|M0|M0DDDD|0~~2047|
705 +|M1|M1DDDDD|2048~~10239|
706 +|SM0|SM0DDD|0~~255|
707 +|SM1|SM1DDD|256~~511|
708 +|S0|S0DDDD|0~~1023|
709 +|S1|S1DDDD|1024~~4095|
710 +|T0|T0DDD|0~~255|
711 +|T1|T1DDD|256~~511|
712 +|C0|C0DDD|0~~255|
713 +|C1|C1DDD|256~~306|
714 +|(% colspan="1" rowspan="7" %)Word|D|DDDDD|0~~7999|
715 +|Z|ZDD|0~~15|
716 +|TW0|TW0DDD|0~~255|
717 +|TW1|TW1DDD|256~~511|
718 +|SD0|SD0DDD|0~~255|
719 +|SD1|SD1DDD|256~~511|
720 +|CW|CWDDD|0~~306|
721 +|(% colspan="1" rowspan="2" %)Double Word|CW0|CW0DDD|200~~255|
722 +|CW1|CW1DDDDD|256~~99999|
723 +
724 +**4) Cable Wiring**
725 +
726 +(% style="text-align:center" %)
727 +[[image:Emerson.png]]
728 +
729 += HollySys PLC =
730 +
731 +== **LK Modbus RTU ** ==
732 +
733 +Supported Series: HollySys LK series PLC
734 +
735 +**1)V-BOX setting**
736 +
737 +|**Items**|**Settings**|**Note**
738 +|Protocol|HollySys LK Modbus RTU|
739 +|Connection|RS485|
740 +|Baud rate|38400|
741 +|Data bit|8|
742 +|Parity|None|
743 +|Stop bit|1|
744 +|Device station No.|1|
745 +
746 +**2)Address List**
747 +
748 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
749 +|Bit|QX|QXDDDDD.dd|0~~65535.15|
750 +|Bit|IX|IXDDDDD.dd|0~~65535.15|
751 +|Bit|MX|MXDDDDD.dd|0~~65535.15|
752 +|Word|QW|QWDDDDD|0~~99999|
753 +|Word|IW|IWDDDDD|0~~99999|
754 +|Word|MW|MWDDDDD|0~~99999|
755 +|Word|MD|MDDDDDD|0~~99999|
756 +
757 +**3)Cable Wiring**
758 +
759 +(% style="text-align:center" %)
760 +[[image:Hollysys485-2.png]]
761 +
762 +== **LM Modbus RTU** ==
763 +
764 +(% class="wikigeneratedid" %)
765 +Supported Series: HollySys LM3109/LM3107 PLC
766 +
767 +(% class="wikigeneratedid" %)
768 +**1)V-BOX setting**
769 +
770 +|(% style="width:208px" %)**Items**|(% style="width:310px" %)**Settings**|(% style="width:365px" %)**Optional**|(% style="width:152px" %)**Note**
771 +|(% style="width:208px" %)Protocol|(% style="width:310px" %)HollySys LM Modbus RTU|(% style="width:365px" %)HollySys LM Modbus RTU|(% style="width:152px" %)
772 +|(% style="width:208px" %)Connection|(% style="width:310px" %)RS232|(% style="width:365px" %)RS485|(% style="width:152px" %)
773 +|(% style="width:208px" %)Baud rate|(% style="width:310px" %)38400|(% style="width:365px" %)38400|(% style="width:152px" %)
774 +|(% style="width:208px" %)Data bit|(% style="width:310px" %)8|(% style="width:365px" %)8|(% style="width:152px" %)
775 +|(% style="width:208px" %)Parity|(% style="width:310px" %)None|(% style="width:365px" %)None|(% style="width:152px" %)
776 +|(% style="width:208px" %)Stop bit|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
777 +|(% style="width:208px" %)Device station No.|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
778 +
779 +**2)Address List**
780 +
781 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
782 +|Bit|QX|QXDDDDD.o|0~~99999.7|
783 +|Bit|IX|IXDDDDD.o|0~~99999.7|
784 +|Bit|MX|MXDDDDD.o|0~~99999.7|
785 +|Word|QW|QWDDDDD|0~~99999|
786 +|Word|IW|IWDDDDD|0~~99999|
787 +|Word|MW|MWDDDDD|0~~99999|
788 +|Word|MD|MDDDDDD|0~~99999|
789 +
790 +**Cable Wiring**
791 +
792 +RS232
793 +
794 +(% style="text-align:center" %)
795 +[[image:HollySysRS232.png]]
796 +
797 +RS485
798 +
799 +(% style="text-align:center" %)
800 +[[image:Hollysys LM Modbus RTU.gif]]
801 +
802 += **Siemens ** =
803 +
804 +== **S7-200 Smart Ethernet ** ==
805 +
806 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
807 +
808 +== **S7-300 Ethernet ** ==
809 +
538 538  Supported Series: Siemens S7-300 series PLC
539 539  
540 540  **1)V-BOX setting**
... ... @@ -591,11 +591,11 @@
591 591  )))
592 592  )))
593 593  
594 -== **S7-1200 Ethernet Protocol** ==
866 +== **S7-1200 Ethernet ** ==
595 595  
596 596  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
597 597  
598 -== **S7-XXX Ethernet Protocol** ==
870 +== **S7-XXX Ethernet l** ==
599 599  
600 600  Supported Series: Siemens S7-400, S7-1200 and S7-1500
601 601  
... ... @@ -709,7 +709,7 @@
709 709  
710 710  [[image:image-20220824162342-2.png]]
711 711  
712 -== **LOGO Ethernet Protocol** ==
984 +== **LOGO Ethernet ** ==
713 713  
714 714  Supported Series: Siemens Logo 0BA0, 0BA1 series
715 715  
... ... @@ -800,9 +800,9 @@
800 800  ** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
801 801  ** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
802 802  
803 -= Create communication with **Mitsubishi PLC** =
1075 += **Mitsubishi ** =
804 804  
805 -== **FX1S,1N,2N Serial Protocol** ==
1077 +== **FX1S,1N,2N Serial ** ==
806 806  
807 807  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
808 808  
... ... @@ -849,7 +849,7 @@
849 849  [[image:image-20220825100845-4.png]]
850 850  
851 851  
852 -== **FX3U,3G,3GA Serial Protocol** ==
1124 +== **FX3U,3G,3GA Serial ** ==
853 853  
854 854  Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
855 855  
... ... @@ -896,7 +896,7 @@
896 896  [[image:image-20220825100845-4.png]]
897 897  
898 898  
899 -== **FX3U Ethernet Protocol** ==
1171 +== **FX3U Ethernet ** ==
900 900  
901 901  Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
902 902  
... ... @@ -991,7 +991,7 @@
991 991  
992 992  [[image:image-20221119101946-2.png||height="395" width="695"]]
993 993  
994 -== **FX5U Serial Protocol** ==
1266 +== **FX5U Serial ** ==
995 995  
996 996  Mitsubishi FX5U series PLC
997 997  
... ... @@ -1073,7 +1073,7 @@
1073 1073  
1074 1074  [[image:image-20220825105533-3.png]]
1075 1075  
1076 -== **FX5U Ethernet Protocol** ==
1348 +== **FX5U Ethernet ** ==
1077 1077  
1078 1078  Mitsubishi FX5U series PLC
1079 1079  
... ... @@ -1149,7 +1149,7 @@
1149 1149  
1150 1150  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1151 1151  
1152 -== **L02 Serial Protocol** ==
1424 +== **L02 Serial ** ==
1153 1153  
1154 1154  Mitsubishi L02 series CPU built-in serial port.
1155 1155  
... ... @@ -1209,7 +1209,7 @@
1209 1209  
1210 1210  [[image:image-20220825160820-4.png]]
1211 1211  
1212 -== **L02 Ethernet Protocol** ==
1484 +== **L02 Ethernet ** ==
1213 1213  
1214 1214  Mitsubishi L series CPU built-in Ethernet port.
1215 1215  
... ... @@ -1282,13 +1282,13 @@
1282 1282  
1283 1283  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1284 1284  
1285 -== **Q12H Serial Protocol** ==
1557 +== **Q12H Serial ** ==
1286 1286  
1287 1287  This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
1288 1288  
1289 1289  [[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]
1290 1290  
1291 -== **QJ71E71 Ethernet Protocol** ==
1563 +== **QJ71E71 Ethernet ** ==
1292 1292  
1293 1293  Mitsubishi QJ71E71 Ethernet communication module;
1294 1294  
... ... @@ -1363,9 +1363,9 @@
1363 1363  
1364 1364  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
1365 1365  
1366 -= Create communication with **Delta PLC** =
1638 += **Delta** =
1367 1367  
1368 -== **DVP Ethernet Protocol** ==
1640 +== **DVP Ethernet** ==
1369 1369  
1370 1370  Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module
1371 1371  
... ... @@ -1430,7 +1430,7 @@
1430 1430  (% style="text-align:center" %)
1431 1431  [[image:DVPEthernetVNETPortocol.png]]
1432 1432  
1433 -== **DVP serial protocol** ==
1705 +== **DVP serial** ==
1434 1434  
1435 1435  Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX
1436 1436  
... ... @@ -1466,7 +1466,7 @@
1466 1466  (% style="text-align:center" %)
1467 1467  [[image:Delta DVP PROTOCOLSerial232.png]]
1468 1468  
1469 -== **AS Ethernet Protocol** ==
1741 +== **AS Ethernet** ==
1470 1470  
1471 1471  **1)V-BOX Settings**
1472 1472  
... ... @@ -1511,19 +1511,18 @@
1511 1511  
1512 1512  [[image:image-20220831155157-3.png]]
1513 1513  
1514 -= Create communication with **Omron PLC** =
1786 += **Omron** =
1515 1515  
1516 -== **CP1 Series Protocol ** ==
1788 +== **CP1 Series** ==
1517 1517  
1518 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1790 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1519 1519  
1520 -== **CP2M Series Protocol** ==
1792 +== **CP2M Series** ==
1521 1521  
1522 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1794 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1523 1523  
1796 +== **EC55 Series ** ==
1524 1524  
1525 -== **EC55 Series Protocol** ==
1526 -
1527 1527  Supported device: EC55 temperature instrument
1528 1528  
1529 1529  **1)V-BOX Settings**
... ... @@ -1583,9 +1583,9 @@
1583 1583  * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1584 1584  * [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1585 1585  
1586 -= Create communication with Xinje** PLC** =
1857 += Xinje =
1587 1587  
1588 -== **XC serial protocol** ==
1859 +== **XC serial** ==
1589 1589  
1590 1590  **1)V-BOX Settings**
1591 1591  
... ... @@ -1627,7 +1627,7 @@
1627 1627  
1628 1628  [[image:image-20220831163441-4.png]]
1629 1629  
1630 -== **XD serial protocol** ==
1901 +== **XD serial** ==
1631 1631  
1632 1632  **1)V-BOX Settings**
1633 1633  
... ... @@ -1701,7 +1701,7 @@
1701 1701  
1702 1702  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1703 1703  
1704 -= Create communication with **Schneider PLC** =
1975 += **Schneider** =
1705 1705  
1706 1706  == **Schneider MODBUS RTU** ==
1707 1707  
... ... @@ -1735,9 +1735,9 @@
1735 1735  
1736 1736  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
1737 1737  
1738 -= Create communication with Inovance** PLC** =
2009 += Inovance =
1739 1739  
1740 -== **H3U serial protocol** ==
2011 +== **H3U serial** ==
1741 1741  
1742 1742  **1)V-BOX Settings**
1743 1743  
... ... @@ -1787,9 +1787,9 @@
1787 1787  
1788 1788  [[image:image-20220831164731-4.png]]
1789 1789  
1790 -= Create communication with Panasonic** PLC** =
2061 += Panasonic =
1791 1791  
1792 -== **FP serial protocol** ==
2063 +== **FP serial** ==
1793 1793  
1794 1794  **1)V-BOX Settings**
1795 1795  
... ... @@ -1837,9 +1837,9 @@
1837 1837  
1838 1838  [[image:image-20220831165008-1.png]]
1839 1839  
1840 -= Create communication with LS** PLC** =
2111 += LS =
1841 1841  
1842 -== **XBC serial protocol** ==
2113 +== **XBC serial** ==
1843 1843  
1844 1844  **1)V-BOX Settings**
1845 1845  
... ... @@ -1891,7 +1891,7 @@
1891 1891  
1892 1892  [[image:image-20220831170215-2.png]]
1893 1893  
1894 -== **XGK FEnet Ethernet protocol** ==
2165 +== **XGK FEnet Ethernet** ==
1895 1895  
1896 1896  Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1897 1897  
... ... @@ -1934,8 +1934,76 @@
1934 1934  
1935 1935  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1936 1936  
1937 -= Create communication with **Modbus ** =
2208 += INVT =
1938 1938  
2210 +**1)V-BOX setting**
2211 +
2212 +|**Item**|**Settings**|**Note**
2213 +|Protocol|INVT_IVC2L|
2214 +|Connection|RS232|
2215 +|Baud rate|19200|
2216 +|Data bit|8|
2217 +|Parity|EVEN|
2218 +|Stop bit|1|
2219 +|PLC station No.|1
2220 +
2221 +**2)Address List**
2222 +
2223 +
2224 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
2225 +|(% colspan="1" rowspan="7" %)Bit|X|XOOO|0~~377|
2226 +|Y|YOOO|0~~377|
2227 +|M|MDDDD|0~~1999|
2228 +|SM|SMDDD|0~~255|
2229 +|S|SDDD|0~~991|
2230 +|T|TDDD|0~~255|
2231 +|C|CDDD|0~~255|
2232 +|(% rowspan="5" %)Word|D|DDDDD|0~~7999|
2233 +|SD|SDDDD|0~~255|
2234 +|Z|ZDD|0~~15|
2235 +|T|TDDD|0~~255|
2236 +|C|CDDD|0~~199|
2237 +|Double word|C|CDDD|200~~255|
2238 +
2239 +**3)Communication Settings**
2240 +
2241 +(% style="text-align:center" %)
2242 +[[image:盒子创建英威腾.png]]
2243 +
2244 +**4)PLC software**
2245 +
2246 +(% style="text-align:center" %)
2247 +[[image:英威腾软件.png]]
2248 +
2249 +**5)PLC setting **
2250 +
2251 +Open the INVI plc software, create a new project or open a project that has already been created
2252 +
2253 +(% style="text-align:center" %)
2254 +[[image:英威腾创建1.png]]
2255 +
2256 +Configure serial port parameters.
2257 +
2258 +(% style="text-align:center" %)
2259 +[[image:英威腾创建2.png]]
2260 +
2261 +PC connect PLC
2262 +
2263 +(% style="text-align:center" %)
2264 +[[image:英威腾创建3.png]]
2265 +
2266 +Download
2267 +
2268 +(% style="text-align:center" %)
2269 +[[image:英威腾下载.png]]
2270 +
2271 +**6)Cable Wiring**
2272 +
2273 +(% style="text-align:center" %)
2274 +[[image:wire.png]]
2275 +
2276 += **Modbus ** =
2277 +
1939 1939  == **MODBUS RTU Slave (All function)** ==
1940 1940  
1941 1941  Select the protocol "Modbus RTU Slave (All Fuction)",
... ... @@ -1945,6 +1945,86 @@
1945 1945  (% style="text-align:center" %)
1946 1946  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
1947 1947  
2287 +== **Modbus Meter** ==
2288 +
2289 +The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication.
2290 +
2291 +~1. Wiring the RS485 cable first. Because the pin 58 is A, the pin 59 is B for meter. Here we use the COM1 to connect. So the diagram like follows:
2292 +
2293 +(% style="text-align:center" %)
2294 +[[image:LinfeeTerminalDiagram.png]]
2295 +
2296 +2. Check the specific Modbus parameter in the communication menu from LED display.
2297 +
2298 +So from the following pictures, we can know the Meter Address is 85, Baud rate is 9600, CRC None.
2299 +
2300 +{{info}}
2301 +**✎Note: **Meter address usually corresponding to the Modbus Slave Station No. on the Modbus communication.
2302 +{{/info}}
2303 +
2304 +(% style="text-align:center" %)
2305 +[[image:MeterModbusAllView.png]]
2306 +
2307 +(% class="wikigeneratedid" %)
2308 +3. Set up the communication in the Configuration tab.
2309 +
2310 +(% class="wikigeneratedid" %)
2311 +Select the protocol as **ModBus RTU Slave (All Function)**. And set the communication parameters like below.
2312 +
2313 +(% style="text-align:center" %)
2314 +[[image:VNETCommunicationtabmeter.png]]
2315 +
2316 +(% class="wikigeneratedid" %)
2317 +4. Create new real-time monitoring tag accroding to Modbus manual
2318 +
2319 +(% class="wikigeneratedid" %)
2320 +Enter the address we want to read from the meter. The following table is intercept part of the manual for Linfee Modbus manual.
2321 +
2322 +(% class="wikigeneratedid" %)
2323 +**0x03/0x04 command data register address**:
2324 +
2325 +(% style="width:1142.22px" %)
2326 +|(% style="display:none" %) |=(% colspan="2" rowspan="1" style="width: 165px;" %)Address(% style="display:none" %) |=Description|=Data Format|=(% style="width: 254px;" %)Data Length(Word)|=(% style="width: 282px;" %)Remark
2327 +|(%%)(% style="display:none" %) (%%) HEX|(% style="width:107px" %)DEC|(%%)(% style="display:none" %) (%%) |(% style="width:100px" %) |(%%)(% style="display:none" %) (%%) |(% style="width:318px" %)
2328 +|(% style="width:107px" %)0x00|(% style="width:100px" %)0|Reserved| | |(% style="width:318px" %)
2329 +|(% style="width:107px" %)0x02|(% style="width:100px" %)2|Reserved| | |(% style="width:318px" %)
2330 +|(% style="width:107px" %)0x04|(% style="width:100px" %)4|Reserved| | |(% style="width:318px" %)
2331 +|(% style="width:107px" %)0x06|(% style="width:100px" %)6|Ua|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2332 +|(% style="width:107px" %)0x08|(% style="width:100px" %)8|Ub|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2333 +|(% style="width:107px" %)0x0A|(% style="width:100px" %)10|Uc|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2334 +|(% style="width:107px" %)0x0C|(% style="width:100px" %)12|Uab|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2335 +|(% style="width:107px" %)0x0E|(% style="width:100px" %)14|Ubc|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2336 +|(% style="width:107px" %)0x10|(% style="width:100px" %)16|Uca|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2337 +|(% style="width:107px" %)0x12|(% style="width:100px" %)18|Ia|float|2|(% style="width:318px" %)Phase Current data, Unit A
2338 +|(% style="width:107px" %)0x14|(% style="width:100px" %)20|Ib|float|2|(% style="width:318px" %)Phase Current data, Unit A
2339 +|(% style="width:107px" %)0x16|(% style="width:100px" %)22|Ic|float|2|(% style="width:318px" %)Phase Current data, Unit A
2340 +
2341 +{{info}}
2342 +**✎Note: **We usually use the Data Type 4 for read the Modbus registers(Function Code 03)
2343 +{{/info}}
2344 +
2345 +For example, here we want to read the Phase Voltage Ua (Modbus offset 0006), the Modbus register main No. requires input decimal number, and check whether the actual address has one address offset, so the tag configured like the following screenshot:
2346 +
2347 +(% style="text-align:center" %)
2348 +[[image:VNETModbusTagSettings.png]]
2349 +
2350 +(% style="text-align:center" %)
2351 +[[image:VNETModbusTagByteSettings.png]]
2352 +
2353 +{{info}}
2354 +**✎Note: **If the read value is incorrect, please check whether need to change the Byte order.
2355 +{{/info}}
2356 +
2357 +Set the Modbus Slave Station No.
2358 +
2359 +(% style="text-align:center" %)
2360 +[[image:ModbusStationSettings.png]]
2361 +
2362 +If the communication is setup successfully, the tag will show green light.
2363 +
2364 +(% style="text-align:center" %)
2365 +[[image:Monitoringtaggreenlight.png]]
2366 +
1948 1948  == **MODBUS RTU Master** ==
1949 1949  
1950 1950  Select the protocol "Modbus RTU Master",
1679563870401-671.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +39.3 KB
Content
1682233464031-639.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +15.9 KB
Content
CCW.Shell_E5Cwj4tUL3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +27.1 KB
Content
ControlStarCommunicate.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +26.0 KB
Content
ControlStarModbus.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content
ControlStarSystemBlock.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +46.3 KB
Content
CrouzetRS232 VBox.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +14.9 KB
Content
Emerson.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
Ethernet.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +45.5 KB
Content
HollySysRS232.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +10.4 KB
Content
Hollysys LM Modbus RTU.gif
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.1 KB
Content
Hollysys485-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.5 KB
Content
Hollysys485box.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.4 KB
Content
LinfeeTerminalDiagram.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content
MeterModbusAddr.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +562.5 KB
Content
MeterModbusAllView.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +1.6 MB
Content
MeterModbusBaud.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +444.0 KB
Content
MeterModbusPara.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +532.0 KB
Content
ModbusStationSettings.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +35.8 KB
Content
Monitoringtaggreenlight.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.5 KB
Content
V-NET_Client setting.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +41.9 KB
Content
V-NET_Client_ADD.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +51.4 KB
Content
V-NET_Client_KOR0AHEA4M.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +14.2 KB
Content
V-NET_Client_TIiAymnjkx.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +12.8 KB
Content
V-NET_Client_TNBuqy7T5r.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +26.7 KB
Content
V-NET_Client_communication.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +25.5 KB
Content
V-NET_Client_iKKKhcgxm1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +35.9 KB
Content
V-NET_Client_t2Rg2wpSoY.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +53.7 KB
Content
VNETCommunicationtabmeter.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +31.0 KB
Content
VNETModbusTagByteSettings.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +31.2 KB
Content
VNETModbusTagSettings.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +35.7 KB
Content
conne ab plc.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +43.1 KB
Content
export.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +115.2 KB
Content
export1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +115.2 KB
Content
plc 软件.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +106.8 KB
Content
project create.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +65.5 KB
Content
software.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +25.8 KB
Content
v-net client vers.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +13.1 KB
Content
wire.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +137.2 KB
Content
企业微信截图_16889606174191.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +20.7 KB
Content
盒子创建英威腾.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +86.5 KB
Content
英威腾下载.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +49.0 KB
Content
英威腾创建1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +36.7 KB
Content
英威腾创建2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +115.7 KB
Content
英威腾创建3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +76.6 KB
Content
英威腾软件.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +52.6 KB
Content