... ... @@ -176,14 +176,6 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 -(% class="wikigeneratedid" %)
180 -= Create communication with ABB PLC =
181 -
182 -== **AC500 Protocol** ==
183 -
184 -Support Series: ABB AC500
185 -
186 -
187 187  = Create communication with **Rockwell PLC** =
188 188  
189 189  == **DF1 Advanced Protocol** ==
... ... @@ -282,12 +282,8 @@
282 282  (% style="text-align:center" %)
283 283  [[image:ABRS232.gif]]
284 284  
285 -(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %)
286 -(% id="cke_bm_5621S" style="display:none" %)** **
277 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
287 287  
288 -== **MicroLogix Protocol** ==
289 -
290 -(% class="wikigeneratedid" %)
291 291  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
292 292  
293 293  **1)V-BOX setting**
... ... @@ -716,97 +716,6 @@
716 716  
717 717  [[image:image-20220824162342-2.png]]
718 718  
719 -== **LOGO Ethernet Protocol** ==
720 -
721 -Supported Series: Siemens Logo 0BA0, 0BA1 series
722 -
723 -**V-BOX Settings**
724 -
725 -
726 -|**Items**|**Settings**|**Note**
727 -|Protocol|Siemens LOGO|
728 -|Connection|Ethernet|
729 -|Port No.|102|
730 -|PLC station No.|2|
731 -
732 -**Address List**
733 -
734 -
735 -|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
736 -|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
737 -|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
738 -|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
739 -|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
740 -|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
741 -|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
742 -|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
743 -|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
744 -|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
745 -|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
746 -|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
747 -|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
748 -|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
749 -|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
750 -|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
751 -
752 -**PLC Settings in LOGO Software:**
753 -
754 -Click [Tools]~-~-[Ethernet Connections],shown as below.
755 -
756 -(% style="text-align:center" %)
757 -[[image:PIStudio.12\.PLC protocols.WebHome@12.PLC Protocol_html_8b9d2322edf89519.png]]
758 -
759 -Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
760 -
761 -(% style="text-align:center" %)
762 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228142937-4.png]]
763 -
764 -**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
765 -
766 -(% style="text-align:center" %)
767 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143047-5.png]]
768 -
769 - **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
770 -
771 -(% style="text-align:center" %)
772 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143246-6.png]]
773 -
774 -**V-BOX Communication Settings**
775 -
776 -Set PLC IP in [IP Address] settings;
777 -
778 -(% style="text-align:center" %)
779 -[[image:LldwDGntf4.png]]
780 -
781 -Enable V-BOX Ethernet in [Network];
782 -
783 -(% style="text-align:center" %)
784 -[[image:WgvjfWbQif.png]]
785 -
786 -TSAP setting
787 -
788 -* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful.
789 -
790 -{{code language="LUA"}}
791 -function init.main()
792 -addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
793 -addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
794 -end
795 -{{/code}}
796 -
797 -Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code.
798 -
799 -**✎Note:**
800 -
801 -* **Communication port configuration: **
802 -** Continuous length needs to be set to 0.
803 -** Integration interval needs to be set to 1. (no change may result in data errors)
804 -** Set Port and Device Station NO.
805 -** Other set as defaulted.
806 -* **Notes on the use of registers:**
807 -** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
808 -** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
809 -
810 810  = Create communication with **Mitsubishi PLC** =
811 811  
812 812  == **FX1S,1N,2N Serial Protocol** ==
0Il1q9GZgk.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -24.6 KB
Content
LldwDGntf4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -24.3 KB
Content
WgvjfWbQif.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -36.3 KB
Content