... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Bob
Content
... ... @@ -176,14 +176,6 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 -(% class="wikigeneratedid" %)
180 -= Create communication with ABB PLC =
181 -
182 -== **AC500 Protocol** ==
183 -
184 -Support Series: ABB AC500
185 -
186 -
187 187  = Create communication with **Rockwell PLC** =
188 188  
189 189  == **DF1 Advanced Protocol** ==
... ... @@ -282,12 +282,8 @@
282 282  (% style="text-align:center" %)
283 283  [[image:ABRS232.gif]]
284 284  
285 -(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %)
286 -(% id="cke_bm_5621S" style="display:none" %)** **
277 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
287 287  
288 -== **MicroLogix Protocol** ==
289 -
290 -(% class="wikigeneratedid" %)
291 291  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
292 292  
293 293  **1)V-BOX setting**
... ... @@ -789,24 +789,13 @@
789 789  
790 790  {{code language="LUA"}}
791 791  function init.main()
792 -addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
793 -addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
780 +    addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
781 +
782 +    addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
783 +
794 794  end
795 795  {{/code}}
796 796  
797 -Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code.
798 -
799 -**✎Note:**
800 -
801 -* **Communication port configuration: **
802 -** Continuous length needs to be set to 0.
803 -** Integration interval needs to be set to 1. (no change may result in data errors)
804 -** Set Port and Device Station NO.
805 -** Other set as defaulted.
806 -* **Notes on the use of registers:**
807 -** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
808 -** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
809 -
810 810  = Create communication with **Mitsubishi PLC** =
811 811  
812 812  == **FX1S,1N,2N Serial Protocol** ==