Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 57 removed)
- 0Il1q9GZgk.png
- AB.gif
- ABRS232.gif
- DVPEthernetAutoSearch.png
- DVPEthernetPLCtoPC.png
- DVPEthernetSetup.png
- DVPEthernetTransfer.png
- DVPEthernetVNETPortocol.png
- DVPEthernetWPLSoft.png
- DVPEthernetWPLSoft2.png
- Delta DVP PROTOCOLSerial232.png
- LldwDGntf4.png
- WgvjfWbQif.png
- image-20220831161356-1.png
- image-20220831163041-1.png
- image-20220831163406-2.png
- image-20220831163422-3.png
- image-20220831163441-4.png
- image-20220831163548-5.png
- image-20220831163553-6.png
- image-20220831163923-7.png
- image-20220831164626-1.png
- image-20220831164646-2.png
- image-20220831164700-3.png
- image-20220831164731-4.png
- image-20220831165008-1.png
- image-20220831165017-2.png
- image-20220831165031-3.png
- image-20220831165238-4.png
- image-20220831170147-1.png
- image-20220831170215-2.png
- image-20220831170254-3.png
- image-20220831170306-4.png
- image-20220831171127-1.png
- image-20220902104329-1.png
- image-20220902111121-1.png
- image-20220902111754-2.png
- image-20220902111833-3.png
- image-20221116105850-1.png
- image-20221116105947-1.png
- image-20221116110802-1.png
- image-20221116110832-2.png
- image-20221116110907-3.png
- image-20221116110917-4.png
- image-20221116111427-1.png
- image-20221116111451-2.png
- image-20221116111509-3.png
- image-20221116111651-4.png
- image-20221116111727-5.png
- image-20221116114106-1.png
- image-20221119101759-1.png
- image-20221119101946-2.png
- image-20221119171318-1.png
- image-20221119171343-2.png
- image-20221119171436-3.png
- image-20221119171611-4.png
- image-20221119171832-5.png
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Ben - Content
-
... ... @@ -176,137 +176,16 @@ 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 178 178 179 -(% class="wikigeneratedid" %) 180 -= Create communication with ABB PLC = 181 - 182 -== **AC500 Protocol** == 183 - 184 -Support Series: ABB AC500 185 - 186 -**1) V-Box Settings** 187 - 188 -|=(% scope="row" %)Item|=Recommended |=Note 189 -|=Protocol|ABB| 190 -|=Connection| | 191 -|=Baud rate| | 192 -|=Stop bits| | 193 -|=Data bits| | 194 -|=Parity| | 195 -|=PLC Station No.| | 196 -|=HMI Station No.| | 197 - 198 - 199 - 200 200 = Create communication with **Rockwell PLC** = 201 201 202 -== **DF1AdvancedProtocol** ==181 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 203 203 204 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 205 - 206 -**1) V-Box Settings** 207 - 208 -|=Item|=Recommended |=Note 209 -|=Protocol|Allen Bradley DF1 Advanced| 210 -|=Connection|RS232| 211 -|=Baud rate|19200| 212 -|=Stop bits|1| 213 -|=Data bits|8| 214 -|=Parity|None| 215 -|=PLC Station No.|1| 216 -|=HMI Station No.|0| 217 - 218 -**2) Address List** 219 - 220 -|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note 221 -|(% colspan="1" rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1 222 -|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0 223 -|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2 224 -|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3 225 -|BN|BNddddd.dd|0.0~~99255.15|((( 226 -Bit data file B0~~B99 227 - 228 -First two digits is for file number 229 - 230 -For example, BN13001.00 represents file number B13, address 001, the 0th bit. 231 -))) 232 -|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7 233 -|NN|NNddddd.dd|0.0~~99255.15|((( 234 -Integer data file bit format N0~~N99 235 - 236 -First two digits is for file number 237 - 238 -For example, NN13001.00 represents file number N13, address 001, the 0th bit. 239 -))) 240 -|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2 241 -|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value) 242 -|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value) 243 -|TNS|TNSddddd|0~~99255|((( 244 -Timer Preset Value 245 - 246 -First two digits is for file number 247 - 248 -For example, TNS99255 represents file number T99, address 255. 249 -))) 250 -|TNP|TNPddddd|0~~99255|((( 251 -Timer Accumulator Value 252 - 253 -First two digits is for file number 254 - 255 -For example, TNP99255 represents file number T99, address 255. 256 -))) 257 -|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value) 258 -|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value) 259 -|CNS|CNSddddd|0~~99255|((( 260 -Counter Preset Value 261 - 262 -First two digits is for file number 263 - 264 -For example, CNS99255 represents file number C99, address 255. 265 -))) 266 -|CNP|CNPddddd|0~~99255|((( 267 -Counter Accumulator Value 268 - 269 -First two digits is for file number 270 - 271 -For example, CNP99255 represents file number C99, address 255. 272 -))) 273 -|N7|N7ddd|0~~255|Only able to communicate with file number N7 274 -|NN|NNddd|0~~99255|((( 275 -Integer data file 276 - 277 -First two digits is for file number 278 - 279 -For example, NN99255 represents file number N99, address 255. 280 -))) 281 -|(% colspan="1" rowspan="3" %)Double Word|F8|F8ddd|0~~255|((( 282 -Only able to communicate with file number N7 283 -))) 284 -|FN|FNddddd|0~~99255|((( 285 -Floating point data file 286 - 287 -First two digits is for file number 288 - 289 -For example, FN99255 represents file number F99, address 255. 290 -))) 291 -|LN|LNddddd|0~~99255|Long 292 - 293 -**3) Cable Wiring** 294 - 295 -(% style="text-align:center" %) 296 -[[image:ABRS232.gif]] 297 - 298 -(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %) 299 -(% id="cke_bm_5621S" style="display:none" %)** ** 300 - 301 -== **MicroLogix Protocol** == 302 - 303 -(% class="wikigeneratedid" %) 304 304 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 305 305 306 -**1) V-BOXsetting**185 +**1)PLC Settings** 307 307 308 308 |**Item**|**Settings**|**Note** 309 -|Protocol|Allen-Bradley DF1 Advanced| 188 +|Protocol|Allen-Bradlley DF1 Advanced| 310 310 |Connection|RS232| 311 311 |Baud rate|19200| 312 312 |Data bit|8| ... ... @@ -541,7 +541,7 @@ 541 541 The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. 542 542 543 543 544 -= **Allen-Bradley Ethernet DF1** = 423 +== **Allen-Bradley Ethernet DF1** == 545 545 546 546 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 547 547 ... ... @@ -557,7 +557,7 @@ 557 557 558 558 Supported Series: Siemens S7-300 series PLC 559 559 560 -**1) V-BOXsetting**439 +**1)PLC Setting** 561 561 562 562 |**Items**|**Settings**|**Note** 563 563 |Protocol|Simens S7-300 Ethernet| ... ... @@ -619,7 +619,7 @@ 619 619 620 620 Supported Series: Siemens S7-400, S7-1200 and S7-1500 621 621 622 -**1) V-BOXsetting**501 +**1)PLC Setting** 623 623 624 624 |=**Items**|=**Settings**|=**Note** 625 625 |Protocol|Siemens S7-XXX| ... ... @@ -729,97 +729,6 @@ 729 729 730 730 [[image:image-20220824162342-2.png]] 731 731 732 -== **LOGO Ethernet Protocol** == 733 - 734 -Supported Series: Siemens Logo 0BA0, 0BA1 series 735 - 736 -**V-BOX Settings** 737 - 738 - 739 -|**Items**|**Settings**|**Note** 740 -|Protocol|Siemens LOGO| 741 -|Connection|Ethernet| 742 -|Port No.|102| 743 -|PLC station No.|2| 744 - 745 -**Address List** 746 - 747 - 748 -|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address** 749 -|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0 750 -|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000 751 -|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000 752 -|4|VW|Word|0-1468|DB1.DBX0.0|0x000000 753 -|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0 754 -|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770 755 -|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0 756 -|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180 757 -|9|AI|Word|1-16|DB1.DBX1032.0|0x002040 758 -|10|I|Bit|1-64|DB1.DBX1024.0|0x002000 759 -|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140 760 -|12|M|Bit|1-112|DB1.DBX1104.0|0x002280 761 -|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0 762 -|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70 763 -|15|V|Bit|0-14697|DB1.DBX0.0|0x000000 764 - 765 -**PLC Settings in LOGO Software:** 766 - 767 -Click [Tools]~-~-[Ethernet Connections],shown as below. 768 - 769 -(% style="text-align:center" %) 770 -[[image:PIStudio.12\.PLC protocols.WebHome@12.PLC Protocol_html_8b9d2322edf89519.png]] 771 - 772 -Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 773 - 774 -(% style="text-align:center" %) 775 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228142937-4.png]] 776 - 777 -**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 778 - 779 -(% style="text-align:center" %) 780 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143047-5.png]] 781 - 782 - **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 783 - 784 -(% style="text-align:center" %) 785 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143246-6.png]] 786 - 787 -**V-BOX Communication Settings** 788 - 789 -Set PLC IP in [IP Address] settings; 790 - 791 -(% style="text-align:center" %) 792 -[[image:LldwDGntf4.png]] 793 - 794 -Enable V-BOX Ethernet in [Network]; 795 - 796 -(% style="text-align:center" %) 797 -[[image:WgvjfWbQif.png]] 798 - 799 -TSAP setting 800 - 801 -* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful. 802 - 803 -{{code language="LUA"}} 804 -function init.main() 805 -addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address 806 -addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address 807 -end 808 -{{/code}} 809 - 810 -Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 811 - 812 -**✎Note:** 813 - 814 -* **Communication port configuration: ** 815 -** Continuous length needs to be set to 0. 816 -** Integration interval needs to be set to 1. (no change may result in data errors) 817 -** Set Port and Device Station NO. 818 -** Other set as defaulted. 819 -* **Notes on the use of registers:** 820 -** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc. 821 -** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 ) 822 - 823 823 = Create communication with **Mitsubishi PLC** = 824 824 825 825 == **FX1S,1N,2N Serial Protocol** == ... ... @@ -916,101 +916,6 @@ 916 916 [[image:image-20220825100845-4.png]] 917 917 918 918 919 -== **FX3U Ethernet Protocol** == 920 - 921 -Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L 922 - 923 -**1)V-BOX Settings** 924 - 925 -|Items|Settings|Note 926 -|Protocol|Mitsubishi FX3U| 927 -|Connection|Ethernet| 928 -|Port No.|5009|Must be the same as the PLC setting 929 -|PLC station No.|0| 930 - 931 -**2)Address List** 932 - 933 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 934 -|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377| 935 -|Y|Y|Y OOO|0~~377| 936 -|M|M|M DDDD|0~~7679| 937 -|SM|SM|SM DDDD|8000~~8511| 938 -|S|S|S DDDD|0~~4095| 939 -|TS|TS|TS DDD|0~~511| 940 -|CS|CS|CS DDD|0~~255| 941 -|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199| 942 -|TN|TN|TN DDD|0~~511| 943 -|D|D|D DDDD|0~~7999| 944 -|SD|SD|SD DDDD|8000~~8511| 945 -|R|R|R DDDDD|0~~32767| 946 - 947 -**3)Ethernet Module Settings** 948 - 949 -FX3U-ENET-L module configuration 950 -Set up the FX3U-ENET-L Ethernet module settings as follows. 951 -Select the module location, which in this document is Module 0. 952 - 953 -[[image:image-20221116105850-1.png]] 954 - 955 -Select "Operational setting" to enter the following screen. 956 - 957 -The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 958 - 959 -[[image:image-20221116105947-1.png]] 960 - 961 -Select "Open setting" to enter the setting interface, the settings are as follows. 962 - 963 -The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the 964 - 965 -Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module. 966 - 967 -[[image:image-20221116110802-1.png]] 968 - 969 -Click on "transter setup" - "PC side I/F setting", see the following figure. 970 - 971 -After setting, the first download must use the programming cable, as shown in the figure; after that, can 972 - 973 -use the IP set in the "Ethernet board" to communicate directly with the network cable. 974 - 975 -[[image:image-20221116110832-2.png||height="423" width="708"]] 976 - 977 -Read and write data from the Ethernet module 978 - 979 -[[image:image-20221116110907-3.png]] 980 - 981 -Set "Transter setup" to COM communication, and read or write operation as shown below 982 - 983 -[[image:image-20221116110917-4.png]] 984 - 985 -**4)PLC Settings (GX Works 2)** 986 - 987 -Create a blank FX5U project 988 - 989 -Find Current Connection in the navigation 990 - 991 -[[image:image-20221116111427-1.png||height="421" width="705"]] 992 - 993 -Select Connection Channel List 994 - 995 -Select Ethernet board communication 996 - 997 -[[image:image-20221116111451-2.png||height="421" width="705"]] 998 - 999 -Select Ethernet Module 1000 -Set the IP address of the PLC 1001 - 1002 -[[image:image-20221116111509-3.png||height="666" width="699"]] 1003 - 1004 -Read or write PLC data, in this document is read 1005 - 1006 -[[image:image-20221116111651-4.png||height="416" width="697"]] 1007 - 1008 -[[image:image-20221116111727-5.png||height="416" width="697"]] 1009 - 1010 -**4)Configure the communication protocol** 1011 - 1012 -[[image:image-20221119101946-2.png||height="395" width="695"]] 1013 - 1014 1014 == **FX5U Serial Protocol** == 1015 1015 1016 1016 Mitsubishi FX5U series PLC ... ... @@ -1165,10 +1165,11 @@ 1165 1165 1166 1166 [[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]] 1167 1167 1168 -**5) Cable Wiring**861 +**5)电缆布线** 1169 1169 1170 1170 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1171 1171 865 + 1172 1172 == **L02 Serial Protocol** == 1173 1173 1174 1174 Mitsubishi L02 series CPU built-in serial port. ... ... @@ -1302,12 +1302,6 @@ 1302 1302 1303 1303 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1304 1304 1305 -== **Q12H Serial Protocol** == 1306 - 1307 -This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol 1308 - 1309 -[[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]] 1310 - 1311 1311 == **QJ71E71 Ethernet Protocol** == 1312 1312 1313 1313 Mitsubishi QJ71E71 Ethernet communication module; ... ... @@ -1356,13 +1356,10 @@ 1356 1356 1357 1357 * Click [Ethernet/CC IE/MELSECNET]; 1358 1358 * Please select [Ethernet] as network type; 1359 -* Set station I/O number according to situation (For example, 00 20 means that the module is connected to PLC CPU in first order);1047 +* Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order); 1360 1360 * Select [Online] as Mode; 1361 -* [[image:image-20221119171343-2.png||height="341" width="587"]] 1362 1362 * Click [Operation setting] to set IP; 1363 1363 * Select [Binary Code] as [Communication Data Code]; 1364 -* [[image:image-20221119171436-3.png||height="354" width="588"]] 1365 -* Click [Open setting] 1366 1366 * Set protocol: TCP; 1367 1367 * Set [unpassive] in [Open system]; 1368 1368 * Set [receive] in [Fixed buffer]; ... ... @@ -1369,16 +1369,14 @@ 1369 1369 * Set [procedure Exist] in [Fixed buffer communication]; 1370 1370 * Disable [Pairing open]; 1371 1371 * Set [No confirm] in [Existence confirmation]; 1372 -* Host station port number: 5009;1057 +* Host station port number: 1025; 1373 1373 * Save settings; 1374 -* [[image:image-20221119171611-4.png||height="354" width="588"]] 1375 1375 * Download project into PLC and restart it 1376 1376 1377 1377 **4)Configure the communication protocol** 1378 1378 1379 -[[image:image-2022 1119171832-5.png||height="354" width="625"]]1063 +[[image:image-20220825143728-1.png]] 1380 1380 1381 - 1382 1382 **5)Cable Wiring** 1383 1383 1384 1384 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]] ... ... @@ -1387,105 +1387,12 @@ 1387 1387 1388 1388 == **DVP Ethernet Protocol** == 1389 1389 1390 - SupoortSeries:ELTA DVP20/32/40/60ES200RE/200TE or anyDVPmodels with built-inEthernetort, DELTA DVPEN01-SL module1073 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 1391 1391 1392 -**1)V-BOX Settings** 1393 - 1394 -|=**Items**|=**Settings**|=**Note** 1395 -|Protocol|DELTA DVP MODBUS TCP| 1396 -|Connection|Ethernet| 1397 -|Port No.|502| 1398 -|Device No.|1| 1399 -|VBox Device No.|0| 1400 - 1401 -**2)Address List ** 1402 - 1403 -|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note** 1404 -|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOO|(% style="width:225px" %)0~~377| 1405 -|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOO|(% style="width:225px" %)0~~377| 1406 -|Bit|(% style="width:191px" %)M0|(% style="width:217px" %)M0|(% style="width:168px" %)M0DDDD|(% style="width:225px" %)0~~1535| 1407 -|Bit|(% style="width:191px" %)M1|(% style="width:217px" %)M1|(% style="width:168px" %)M1DDDD|(% style="width:225px" %)1536~~4096| 1408 -|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255| 1409 -|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~255| 1410 -|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDD|(% style="width:225px" %)0~~1023| 1411 -|Word|(% style="width:191px" %)D0|(% style="width:217px" %)D0|(% style="width:168px" %)D0DDDD|(% style="width:225px" %)0~~4095| 1412 -|Word|(% style="width:191px" %)D1|(% style="width:217px" %)D1|(% style="width:168px" %)D1DDDD|(% style="width:225px" %)4096~~11999| 1413 -|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255| 1414 -|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199| 1415 -|Double Word|(% style="width:191px" %)HC|(% style="width:217px" %)HC|(% style="width:168px" %)HCDDD|(% style="width:225px" %)200~~255| 1416 - 1417 -**3) PLC Setting:** 1418 - 1419 -~1. Create new project in Delta WPL Soft, and click Setting to open the communication settings: 1420 - 1421 -(% style="text-align:center" %) 1422 -[[image:DVPEthernetWPLSoft2.png]] 1423 - 1424 -2. Set up the communication type and PLC IP: 1425 - 1426 -(% style="text-align:center" %) 1427 -[[image:DVPEthernetSetup.png]] 1428 - 1429 -(% class="wikigeneratedid" %) 1430 -3. Click OK and save the settings. Then click Communication on toolbar, then click Transfer Setup to open new window: 1431 - 1432 -(% style="text-align:center" %) 1433 -[[image:DVPEthernetTransfer.png]] 1434 - 1435 -(% class="wikigeneratedid" %) 1436 -4. Select Communication Mode as PC => PLC to download or select PC <=PLC to upload: 1437 - 1438 -(% style="text-align:center" %) 1439 -[[image:DVPEthernetPLCtoPC.png]] 1440 - 1441 -5. Click Auto-Search Ethernet Module to find the PLC on the same LAN network: 1442 - 1443 -(% style="text-align:center" %) 1444 -[[image:DVPEthernetAutoSearch.png]] 1445 - 1446 -**4) V-BOX Setting:** 1447 - 1448 -Set the same IP address according to the setting from WPL Soft: 1449 - 1450 -(% style="text-align:center" %) 1451 -[[image:DVPEthernetVNETPortocol.png]] 1452 - 1453 1453 == **DVP serial protocol** == 1454 1454 1455 - SupoortSeries:DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX1077 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 1456 1456 1457 -**1)V-BOX Settings** 1458 - 1459 -|=**Items**|=**Settings**|=**Note** 1460 -|Protocol|DELTA DVP PROTOCOL| 1461 -|Connection|RS232| 1462 -|Baud Rate|9600| 1463 -|Stop Bit|1| 1464 -|Data Bit|7| 1465 -|Parity|EVEN| 1466 -|Device No.|1| 1467 - 1468 -(% class="wikigeneratedid" %) 1469 -**2)Address List** 1470 - 1471 -|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note** 1472 -|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOOOOO|(% style="width:225px" %)0~~303237| 1473 -|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOOOOO|(% style="width:225px" %)0~~303237| 1474 -|Bit|(% style="width:191px" %)M|(% style="width:217px" %)M|(% style="width:168px" %)MDDDDD|(% style="width:225px" %)0~~99999| 1475 -|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999| 1476 -|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)0~~99999| 1477 -|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDDD|(% style="width:225px" %)0~~99999| 1478 -|Word|(% style="width:191px" %)D|(% style="width:217px" %)D|(% style="width:168px" %)D DDDDD|(% style="width:225px" %)0~~99999| 1479 -|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999| 1480 -|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199| 1481 -|Double Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)200~~99999| 1482 - 1483 -(% class="wikigeneratedid" %) 1484 -**3)Wiring Diagram** 1485 - 1486 -(% style="text-align:center" %) 1487 -[[image:Delta DVP PROTOCOLSerial232.png]] 1488 - 1489 1489 == **AS Ethernet Protocol** == 1490 1490 1491 1491 **1)V-BOX Settings** ... ... @@ -1519,6 +1519,7 @@ 1519 1519 1520 1520 **3)Configure the communication protocol** 1521 1521 1112 + 1522 1522 [[image:image-20220831160010-4.png]] 1523 1523 1524 1524 **4)Cable Wiring** ... ... @@ -1542,7 +1542,7 @@ 1542 1542 [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 1543 1543 1544 1544 1545 -== **EC55 SeriesProtocol** ==1136 +== **EC55 Protocol** == 1546 1546 1547 1547 Supported device: EC55 temperature instrument 1548 1548 ... ... @@ -1601,363 +1601,12 @@ 1601 1601 * Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document. 1602 1602 * When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable. 1603 1603 * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests. 1604 -* [[image: image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.1195 +* [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_d428cad280fdefb3.png?width=347&height=276&rev=1.1||alt="12.PLC Protocol_html_d428cad280fdefb3.png" height="276" width="347"]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written. 1605 1605 1606 -= Create communication with Xinje**PLC** =1197 += Create communication with **Modbus RTU** = 1607 1607 1608 -== **X Cserialprotocol** ==1199 +== **V-BOX as Slave** == 1609 1609 1610 -**1)V-BOX Settings** 1611 - 1612 -|**Item**|**Settings**|**Note** 1613 -|Protocol|XINJE XC MODBUS| 1614 -|Connection|RS232| 1615 -|Baud rate|19200| 1616 -|Data bit|8| 1617 -|Parity|EVEN| 1618 -|Stop bit|1| 1619 -|PLC station No.|1| 1620 - 1621 -**2)Address List** 1622 - 1623 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1624 -|Bit|M|M|M d|0~~8511| 1625 -|Bit|X|X|X o|0~~1747| 1626 -|Bit|Y|Y|Y o|0~~1747| 1627 -|Bit|S|S|S d|0~~1023| 1628 -|Bit|T|T|T d|0~~4095| 1629 -|Bit|C|C|C d|0~~634| 1630 -|Word|D|D|D d|0~~8511| 1631 -|Word|TD|TD|TD d|0~~618| 1632 -|Word|CD|CD|CD d|0~~634| 1633 -|Word|FD|FD|FD d|0~~8511| 1634 - 1635 -**3)Configure the communication protocol** 1636 - 1637 - 1638 -[[image:image-20220831163041-1.png]] 1639 - 1640 -**4)Cable Wiring** 1641 - 1642 -Figure 1643 - 1644 -[[image:image-20220831163406-2.png]][[image:image-20220831163422-3.png]] 1645 - 1646 -Pin Definition Diagram 1647 - 1648 -[[image:image-20220831163441-4.png]] 1649 - 1650 -== **XD serial protocol** == 1651 - 1652 -**1)V-BOX Settings** 1653 - 1654 -Supported Series: Xinjie XD/XE Series PLC 1655 - 1656 -|**Item**|**Settings**|**Note** 1657 -|Protocol|XINJE XD/XC MODBUS| 1658 -|Connection|RS232| 1659 -|Baud rate|19200| 1660 -|Data bit|8| 1661 -|Parity|EVEN| 1662 -|Stop bit|1| 1663 -|PLC station No.|1| 1664 - 1665 -**2)Address List** 1666 - 1667 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1668 -|Bit|M|M|M d|0~~74999| 1669 -|Bit|X1xx|X1xx|X1xx o|0~~1177| 1670 -|Bit|X2xx|X2xx|X2xx o|0~~277| 1671 -|Bit|X|X|X o|0~~77| 1672 -|Bit|Y1xx|Y1xx|Y1xx o|0~~1177| 1673 -|Bit|Y2xx|Y2xx|Y2xx o|0~~277| 1674 -|Bit|Y|Y|Y o|0~~4095| 1675 -|Bit|SM|SM|SM d|0~~4999|((( 1676 - 1677 -))) 1678 -|Bit|T|T|T d|0~~4999| 1679 -|Bit|C|C|C d|0~~4999| 1680 -|Bit|ET|ET|ET d|0~~31| 1681 -|Bit|SE|SE|SE d|0~~31| 1682 -|Bit|HM|HM|HM d|0~~11999| 1683 -|Bit|HSC|HSC|HSC d|0~~39| 1684 -|Bit|HS|HS|HS d|0~~999| 1685 -|Bit|HT|HT|HT d|0~~1999| 1686 -|Bit|HC|HC|HC d|0~~1999| 1687 -|Bit|S|S|S d|0~~7999| 1688 -|Word|D|D|D d|0~~69999| 1689 -|Word|ID|ID|ID d|0~~99| 1690 -|Word|ID1xx|ID1xx|ID1xx d|0~~999| 1691 -|Word|ID2xx|ID2xx|ID2xx d|0~~299| 1692 -|Word|QD|QD|QD d|0~~99| 1693 -|Word|QD1xx|QD1xx|QD1xx d|0~~999| 1694 -|Word|QD2xx|QD2xx|QD2xx d|0~~299| 1695 -|Word|SD|SD|SD d|0~~4999| 1696 -|Word|TD|TD|TD d|0~~575| 1697 -|Word|CD|CD|CD d|0~~575| 1698 -|Word|ETD|ETD|ETD d|0~~31| 1699 -|Word|HD|HD|HD d|0~~24999| 1700 -|Word|HSD|HSD|HSD d|0~~1023| 1701 -|Word|HTD|HTD|HTD d|0~~95| 1702 -|Word|HCD|HCD|HCD d|0~~95| 1703 -|Word|HSCD|HSCD|HSCD d|0~~31| 1704 -|Word|FD|FD|FD d|0~~8191| 1705 -|Word|SFD|SFD|SFD d|0~~5999| 1706 -|Word|FS|FS|FS d|0~~47| 1707 - 1708 -**3)Configure the communication protocol** 1709 - 1710 -[[image:image-20220831163923-7.png]] 1711 - 1712 - 1713 - 1714 -**4)Cable Wiring** 1715 - 1716 -Figure 1717 - 1718 -[[image:image-20220831163406-2.png]][[image:image-20220831163553-6.png]] 1719 - 1720 -Pin Definition Diagram 1721 - 1722 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]] 1723 - 1724 -= Create communication with **Schneider PLC** = 1725 - 1726 -== **Schneider MODBUS RTU** == 1727 - 1728 -**1)V-BOX Setting** 1729 - 1730 -|=**Parameters**|=**Recommended**|=**Notes** 1731 -|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU| 1732 -|**Connection**|RS485| 1733 -|**Baud rate**|19200| 1734 -|**Data bit**|8| 1735 -|**Parity**|Even| 1736 -|**Stop bit**|1| 1737 -|**PLC station No.**|1| 1738 - 1739 -**2)Address List** 1740 - 1741 -|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo** 1742 -|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only) 1743 -|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils 1744 -|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal) 1745 -|W|MW|DDDDDD|0 ~~ 999999|Output register 1746 -|DW|MD|DDDDDD|0 ~~ 999999|Output register 1747 - 1748 -**3)Configure the communication protocol** 1749 - 1750 -[[image:image-20220902104329-1.png]] 1751 - 1752 -**4)Cable Wiring** 1753 - 1754 -**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector. 1755 - 1756 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]] 1757 - 1758 -= Create communication with Inovance** PLC** = 1759 - 1760 -== **H3U serial protocol** == 1761 - 1762 -**1)V-BOX Settings** 1763 - 1764 -|**Item**|**Settings**|**Note** 1765 -|Protocol|INOVANCE H3U PLC| 1766 -|Connection|RS422| 1767 -|Baud rate|9600| 1768 -|Data bit|7| 1769 -|Parity|EVEN| 1770 -|Stop bit|1| 1771 -|PLC station No.|0| 1772 - 1773 -**2)Address List** 1774 - 1775 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1776 -|Bit|X|X|X o|0~~303237| 1777 -|Bit|Y|Y|Y o|0~~303237| 1778 -|Bit|M|M|M d|0~~99999| 1779 -|Bit|T|T|T d|0~~99999| 1780 -|Bit|C|C|C d|0~~99999| 1781 -|Bit|SM|SM|SM d|8000~~999| 1782 -|Bit|S|T|S d|0~~99999| 1783 -|Bit|Lamp|Lamp|Lamp d|0~~0| 1784 -|Word|X|X|X o|0~~303237| 1785 -|Word|Y|Y|Y o|0~~303237| 1786 -|Word|M|M|M d|0~~99999| 1787 -|Word|T|T|T d|0~~99999| 1788 -|Word|C|C|C d|0~~199| 1789 -|Word|D|D|D d|0~~7999| 1790 -|Word|S|S|S d|0~~99999| 1791 -|Word|SD|SD|SD d|8000~~9999| 1792 -|Word|R|R|R d|0~~32767| 1793 - 1794 -**3)Configure the communication protocol** 1795 - 1796 -[[image:image-20220831164626-1.png]] 1797 - 1798 - 1799 - 1800 -**4)Cable Wiring** 1801 - 1802 -Figure 1803 - 1804 -[[image:image-20220831164646-2.png]][[image:image-20220831164700-3.png]] 1805 - 1806 -Pin Definition Diagram 1807 - 1808 -[[image:image-20220831164731-4.png]] 1809 - 1810 -= Create communication with Panasonic** PLC** = 1811 - 1812 -== **FP serial protocol** == 1813 - 1814 -**1)V-BOX Settings** 1815 - 1816 -|**Item**|**Settings**|**Note** 1817 -|Protocol|Panasonic FP MFWTOCOL| 1818 -|Connection|RS232| 1819 -|Baud rate|9600| 1820 -|Data bit|8| 1821 -|Parity|ODD| 1822 -|Stop bit|1| 1823 -|PLC station No.|1| 1824 - 1825 -**2)Address List** 1826 - 1827 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1828 -|Bit|X|X|X d|0~~9999| 1829 -|Bit|Y|Y|Y d|0~~9999| 1830 -|Bit|R|R|R d|0~~9999| 1831 -|Bit|T|T|T d|0~~9999| 1832 -|Bit|C|C|C d|0~~9999| 1833 -|Bit|L|L|L d|0~~9999| 1834 -|Word|WX|WX|WX d|0~~9999| 1835 -|Word|WY|WY|WY d|0~~9999| 1836 -|Word|WR|WR|WR d|0~~9999| 1837 -|Word|WL|WL|WL d|0~~9999| 1838 -|Word|LD|LD|LD d|0~~9999| 1839 -|Word|DT|DT|DT d|0~~65535| 1840 -|Word|FL|FL|FL d|0~~9999| 1841 -|Word|EV|EV|EV d|0~~9999| 1842 -|Word|SV|SV|SV d|0~~9999| 1843 - 1844 -**3)Configure the communication protocol** 1845 - 1846 -[[image:image-20220831165238-4.png]] 1847 - 1848 - 1849 - 1850 -**4)Cable Wiring** 1851 - 1852 -Figure 1853 - 1854 -[[image:image-20220831165031-3.png]][[image:image-20220831165017-2.png]] 1855 - 1856 -Pin Definition Diagram 1857 - 1858 -[[image:image-20220831165008-1.png]] 1859 - 1860 -= Create communication with LS** PLC** = 1861 - 1862 -== **XBC serial protocol** == 1863 - 1864 -**1)V-BOX Settings** 1865 - 1866 -|**Item**|**Settings**|**Note** 1867 -|Protocol|LS XBC CNet| 1868 -|Connection|RS232| 1869 -|Baud rate|115200| 1870 -|Data bit|8| 1871 -|Parity|NONE| 1872 -|Stop bit|1| 1873 -|PLC station No.|1| 1874 - 1875 -**2)Address List** 1876 - 1877 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1878 -|Bit|P|P|P d|0~~2047| 1879 -|Bit|M|M|M d|0~~2047| 1880 -|Bit|L|L|L d|0~~11263| 1881 -|Bit|K|K|K d|0~~16183| 1882 -|Bit|F|F|F d|0~~2047| 1883 -|Bit|D|D|D d|0~~32767| 1884 -|Bit|R|R|R d|0~~32767| 1885 -|Bit|U|U|U d|0~~4095| 1886 -|Word|P|P|P d|0~~2047| 1887 -|Word|M|M|M d|0~~2047| 1888 -|Word|L|L|L d|0~~11263| 1889 -|Word|K|K|K d|0~~16183| 1890 -|Word|F|F|F d|0~~2047| 1891 -|Word|C|C|C d|0~~2047| 1892 -|Word|T|T|T d|0~~2047| 1893 -|Word|D|D|D d|0~~32767| 1894 -|Word|N|N|N d|0~~21503| 1895 -|Word|R|R|R d|0~~32767| 1896 -|Word|U|U|U d|0~~4095| 1897 -|Word|Z|Z|Z d|0~~127| 1898 -|Word|S|S|S d|0~~127| 1899 - 1900 -**3)Configure the communication protocol** 1901 - 1902 -[[image:image-20220831170147-1.png]] 1903 - 1904 -**4)Cable Wiring** 1905 - 1906 -Figure 1907 - 1908 -[[image:image-20220831170306-4.png]][[image:image-20220831170254-3.png]] 1909 - 1910 -Pin Definition Diagram 1911 - 1912 -[[image:image-20220831170215-2.png]] 1913 - 1914 -== **XGK FEnet Ethernet protocol** == 1915 - 1916 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 1917 - 1918 -**1)V-BOX Settings** 1919 - 1920 -|**Items**|**Settings**|**Note** 1921 -|Protocol|LG XGK FEnet(Ethernet)| 1922 -|Connection|Ethernet| 1923 -|Port No.|2004| 1924 - 1925 -**2)Address List** 1926 - 1927 -|**Type**|**Register**|**Range**|**Format**|**Note** 1928 -|(% rowspan="14" %)Word|P|0~~2047|P d| 1929 -|M|0~~2047|M d| 1930 -|K|0~~2047|K d| 1931 -|F|0~~2047|F d| 1932 -|T|0~~2047|T d| 1933 -|C|0~~2047|C d| 1934 -|Z|0~~127|Z d| 1935 -|S|0~~127|S d| 1936 -|L|0~~11263|L d| 1937 -|N|0~~21503|N d| 1938 -|D|0~~32767|D d| 1939 -|R|0~~32767|R d| 1940 -|ZR|0~~65535|ZR d| 1941 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 1942 - 1943 -**✎Note:** 1944 - 1945 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 1946 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 1947 -* All bit registers are in the form of bits in word, and the range is the same as the word register; 1948 - 1949 -**3)Communication Settings** 1950 - 1951 -[[image:image-20220831171127-1.png]] 1952 - 1953 -**4)Cable Wiring** 1954 - 1955 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1956 - 1957 -= Create communication with **Modbus ** = 1958 - 1959 -== **MODBUS RTU Slave (All function)** == 1960 - 1961 1961 Select the protocol "Modbus RTU Slave (All Fuction)", 1962 1962 1963 1963 Then set baud rate, port, stop bits, data bits, parity. ... ... @@ -1965,7 +1965,7 @@ 1965 1965 (% style="text-align:center" %) 1966 1966 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 1967 1967 1968 -== ** MODBUSRTUMaster** ==1208 +== **V-BOX as Master** == 1969 1969 1970 1970 Select the protocol "Modbus RTU Master", 1971 1971 ... ... @@ -1977,8 +1977,8 @@ 1977 1977 **address list** 1978 1978 1979 1979 (% class="table-bordered" %) 1980 -| =(% scope="row" %)**Type**|=**Data Type**|=**Function code and description**1981 -|(% rowspan="11" %) Word|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)1220 +|**type**|**register**|**Function code and description** 1221 +|(% rowspan="11" %)词|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers) 1982 1982 |06 (write single register: write a binary value to a holding register) 1983 1983 |10 (write values to multiple addresses ) 1984 1984 |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) ... ... @@ -2001,61 +2001,6 @@ 2001 2001 |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 2002 2002 |0F (Write multiple bits) 2003 2003 2004 -== **MODBUS TCP Slave (All function)** == 2005 - 2006 -Supported series: MODBUS TCP controller 2007 - 2008 -V-B0X works as MODBUS TCP MASTER connecting with TCP SLAVE 2009 - 2010 -**1)V-BOX Setting** 2011 - 2012 -|**Items**|**Settings**|**Note** 2013 -|Protocol|MODBUS TCP Slave (All function)| 2014 -|Connection|Ethernet| 2015 -|Port No.|502| 2016 -|PLC station No.|1 2017 - 2018 -**2)Address List** 2019 - 2020 -|=**Type**|=**Data Type**|=**Function code & Description** 2021 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 2022 -|06 (write single register: write a binary value to a holding register) 2023 -|10 (write values to multiple addresses ) 2024 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 2025 -|06 (write single register: write a binary value to a holding register) 2026 -|10 (write values to multiple addresses ) 2027 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 2028 -|06 (write single register: write a binary value to a holding register) 2029 -|10 (write values to multiple addresses ) 2030 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 2031 -|10 (write values to multiple addresses ) 2032 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 2033 -|05 (Force a single coil to force the on/off state of a logic coil) 2034 -|0F (Write multiple bits, ie write continuously) 2035 -|(% rowspan="3" %)1|02 (Read the input state) 2036 -|05 (Force a single coil to force the on/off state of a logic coil) 2037 -|0F (Write multiple bits) 2038 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 2039 -|05 (Force a single coil to force the on/off state of a logic coil) 2040 -|0F (Write multiple bits) 2041 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 2042 -|0F (Write multiple bits) 2043 - 2044 -**3)Communication Settings** 2045 - 2046 -Configure V-BOX Ethernet IP in Networking Settings 2047 - 2048 -[[image:image-20220902111833-3.png]] 2049 - 2050 - 2051 -Configure PLC Ethernet IP in Communication; 2052 - 2053 -[[image:image-20220902111121-1.png]] 2054 - 2055 -**4)Cable Wiring** 2056 - 2057 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 2058 - 2059 2059 == **communicate with VB inverter** == 2060 2060 2061 2061 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
- 0Il1q9GZgk.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.6 KB - Content
- AB.gif
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -7.3 KB - Content
- ABRS232.gif
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -7.3 KB - Content
- DVPEthernetAutoSearch.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -43.6 KB - Content
- DVPEthernetPLCtoPC.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -8.9 KB - Content
- DVPEthernetSetup.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.9 KB - Content
- DVPEthernetTransfer.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -59.9 KB - Content
- DVPEthernetVNETPortocol.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -21.4 KB - Content
- DVPEthernetWPLSoft.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -97.5 KB - Content
- DVPEthernetWPLSoft2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -45.2 KB - Content
- Delta DVP PROTOCOLSerial232.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -10.7 KB - Content
- LldwDGntf4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.3 KB - Content
- WgvjfWbQif.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -36.3 KB - Content
- image-20220831161356-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -27.0 KB - Content
- image-20220831163041-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -58.6 KB - Content
- image-20220831163406-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -28.4 KB - Content
- image-20220831163422-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -53.9 KB - Content
- image-20220831163441-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -13.7 KB - Content
- image-20220831163548-5.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -37.1 KB - Content
- image-20220831163553-6.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -37.1 KB - Content
- image-20220831163923-7.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -57.3 KB - Content
- image-20220831164626-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -56.1 KB - Content
- image-20220831164646-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -28.4 KB - Content
- image-20220831164700-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -66.6 KB - Content
- image-20220831164731-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -12.3 KB - Content
- image-20220831165008-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -13.3 KB - Content
- image-20220831165017-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -36.2 KB - Content
- image-20220831165031-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -28.3 KB - Content
- image-20220831165238-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -57.4 KB - Content
- image-20220831170147-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -57.1 KB - Content
- image-20220831170215-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -14.3 KB - Content
- image-20220831170254-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -43.5 KB - Content
- image-20220831170306-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -28.5 KB - Content
- image-20220831171127-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -60.1 KB - Content
- image-20220902104329-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -58.7 KB - Content
- image-20220902111121-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -60.9 KB - Content
- image-20220902111754-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -57.6 KB - Content
- image-20220902111833-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -56.1 KB - Content
- image-20221116105850-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -18.9 KB - Content
- image-20221116105947-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -18.7 KB - Content
- image-20221116110802-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -16.4 KB - Content
- image-20221116110832-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -42.2 KB - Content
- image-20221116110907-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.8 KB - Content
- image-20221116110917-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.2 KB - Content
- image-20221116111427-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -63.4 KB - Content
- image-20221116111451-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -225.5 KB - Content
- image-20221116111509-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -34.1 KB - Content
- image-20221116111651-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -74.3 KB - Content
- image-20221116111727-5.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -106.2 KB - Content
- image-20221116114106-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -99.5 KB - Content
- image-20221119101759-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -62.1 KB - Content
- image-20221119101946-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -68.7 KB - Content
- image-20221119171318-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -90.3 KB - Content
- image-20221119171343-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -90.3 KB - Content
- image-20221119171436-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -43.4 KB - Content
- image-20221119171611-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.1 KB - Content
- image-20221119171832-5.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -69.6 KB - Content