... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Bob
Content
... ... @@ -176,27 +176,6 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 -(% class="wikigeneratedid" %)
180 -= Create communication with ABB PLC =
181 -
182 -== **AC500 Protocol** ==
183 -
184 -Support Series: ABB AC500
185 -
186 -**1) V-Box Settings**
187 -
188 -|=(% scope="row" %)Item|=Recommended |=Note
189 -|=Protocol|ABB|
190 -|=Connection| |
191 -|=Baud rate| |
192 -|=Stop bits| |
193 -|=Data bits| |
194 -|=Parity| |
195 -|=PLC Station No.| |
196 -|=HMI Station No.| |
197 -
198 -
199 -
200 200  = Create communication with **Rockwell PLC** =
201 201  
202 202  == **DF1 Advanced Protocol** ==
... ... @@ -295,12 +295,8 @@
295 295  (% style="text-align:center" %)
296 296  [[image:ABRS232.gif]]
297 297  
298 -(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %)
299 -(% id="cke_bm_5621S" style="display:none" %)** **
277 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
300 300  
301 -== **MicroLogix Protocol** ==
302 -
303 -(% class="wikigeneratedid" %)
304 304  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
305 305  
306 306  **1)V-BOX setting**
... ... @@ -802,24 +802,13 @@
802 802  
803 803  {{code language="LUA"}}
804 804  function init.main()
805 -addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
806 -addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
780 +    addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
781 +
782 +    addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
783 +
807 807  end
808 808  {{/code}}
809 809  
810 -Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code.
811 -
812 -**✎Note:**
813 -
814 -* **Communication port configuration: **
815 -** Continuous length needs to be set to 0.
816 -** Integration interval needs to be set to 1. (no change may result in data errors)
817 -** Set Port and Device Station NO.
818 -** Other set as defaulted.
819 -* **Notes on the use of registers:**
820 -** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
821 -** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
822 -
823 823  = Create communication with **Mitsubishi PLC** =
824 824  
825 825  == **FX1S,1N,2N Serial Protocol** ==