Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Bob - Content
-
... ... @@ -176,27 +176,6 @@ 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 178 178 179 -(% class="wikigeneratedid" %) 180 -= Create communication with ABB PLC = 181 - 182 -== **AC500 Protocol** == 183 - 184 -Support Series: ABB AC500 185 - 186 -**1) V-Box Settings** 187 - 188 -|=(% scope="row" %)Item|=Recommended |=Note 189 -|=Protocol|ABB| 190 -|=Connection| | 191 -|=Baud rate| | 192 -|=Stop bits| | 193 -|=Data bits| | 194 -|=Parity| | 195 -|=PLC Station No.| | 196 -|=HMI Station No.| | 197 - 198 - 199 - 200 200 = Create communication with **Rockwell PLC** = 201 201 202 202 == **DF1 Advanced Protocol** == ... ... @@ -295,12 +295,8 @@ 295 295 (% style="text-align:center" %) 296 296 [[image:ABRS232.gif]] 297 297 298 -(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %) 299 -(% id="cke_bm_5621S" style="display:none" %)** ** 277 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 300 300 301 -== **MicroLogix Protocol** == 302 - 303 -(% class="wikigeneratedid" %) 304 304 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 305 305 306 306 **1)V-BOX setting** ... ... @@ -802,24 +802,13 @@ 802 802 803 803 {{code language="LUA"}} 804 804 function init.main() 805 -addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address 806 -addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address 780 + addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address 781 + 782 + addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address 783 + 807 807 end 808 808 {{/code}} 809 809 810 -Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 811 - 812 -**✎Note:** 813 - 814 -* **Communication port configuration: ** 815 -** Continuous length needs to be set to 0. 816 -** Integration interval needs to be set to 1. (no change may result in data errors) 817 -** Set Port and Device Station NO. 818 -** Other set as defaulted. 819 -* **Notes on the use of registers:** 820 -** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc. 821 -** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 ) 822 - 823 823 = Create communication with **Mitsubishi PLC** = 824 824 825 825 == **FX1S,1N,2N Serial Protocol** ==