Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -176,8 +176,6 @@ 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 178 178 179 - 180 - 181 181 = Create communication with **Rockwell PLC** = 182 182 183 183 == **DF1 Advanced Protocol** == ... ... @@ -276,12 +276,8 @@ 276 276 (% style="text-align:center" %) 277 277 [[image:ABRS232.gif]] 278 278 279 -(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %) 280 -(% id="cke_bm_5621S" style="display:none" %)** ** 277 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 281 281 282 -== **MicroLogix Protocol** == 283 - 284 -(% class="wikigeneratedid" %) 285 285 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 286 286 287 287 **1)V-BOX setting** ... ... @@ -710,97 +710,6 @@ 710 710 711 711 [[image:image-20220824162342-2.png]] 712 712 713 -== **LOGO Ethernet Protocol** == 714 - 715 -Supported Series: Siemens Logo 0BA0, 0BA1 series 716 - 717 -**V-BOX Settings** 718 - 719 - 720 -|**Items**|**Settings**|**Note** 721 -|Protocol|Siemens LOGO| 722 -|Connection|Ethernet| 723 -|Port No.|102| 724 -|PLC station No.|2| 725 - 726 -**Address List** 727 - 728 - 729 -|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address** 730 -|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0 731 -|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000 732 -|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000 733 -|4|VW|Word|0-1468|DB1.DBX0.0|0x000000 734 -|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0 735 -|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770 736 -|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0 737 -|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180 738 -|9|AI|Word|1-16|DB1.DBX1032.0|0x002040 739 -|10|I|Bit|1-64|DB1.DBX1024.0|0x002000 740 -|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140 741 -|12|M|Bit|1-112|DB1.DBX1104.0|0x002280 742 -|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0 743 -|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70 744 -|15|V|Bit|0-14697|DB1.DBX0.0|0x000000 745 - 746 -**PLC Settings in LOGO Software:** 747 - 748 -Click [Tools]~-~-[Ethernet Connections],shown as below. 749 - 750 -(% style="text-align:center" %) 751 -[[image:PIStudio.12\.PLC protocols.WebHome@12.PLC Protocol_html_8b9d2322edf89519.png]] 752 - 753 -Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 754 - 755 -(% style="text-align:center" %) 756 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228142937-4.png]] 757 - 758 -**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 759 - 760 -(% style="text-align:center" %) 761 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143047-5.png]] 762 - 763 - **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 764 - 765 -(% style="text-align:center" %) 766 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143246-6.png]] 767 - 768 -**V-BOX Communication Settings** 769 - 770 -Set PLC IP in [IP Address] settings; 771 - 772 -(% style="text-align:center" %) 773 -[[image:LldwDGntf4.png]] 774 - 775 -Enable V-BOX Ethernet in [Network]; 776 - 777 -(% style="text-align:center" %) 778 -[[image:WgvjfWbQif.png]] 779 - 780 -TSAP setting 781 - 782 -* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful. 783 - 784 -{{code language="LUA"}} 785 -function init.main() 786 -addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address 787 -addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address 788 -end 789 -{{/code}} 790 - 791 -Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 792 - 793 -**✎Note:** 794 - 795 -* **Communication port configuration: ** 796 -** Continuous length needs to be set to 0. 797 -** Integration interval needs to be set to 1. (no change may result in data errors) 798 -** Set Port and Device Station NO. 799 -** Other set as defaulted. 800 -* **Notes on the use of registers:** 801 -** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc. 802 -** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 ) 803 - 804 804 = Create communication with **Mitsubishi PLC** = 805 805 806 806 == **FX1S,1N,2N Serial Protocol** ==
- 0Il1q9GZgk.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.6 KB - Content
- LldwDGntf4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.3 KB - Content
- WgvjfWbQif.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -36.3 KB - Content