Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -176,10 +176,8 @@ 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 178 178 179 += Create communication with Allen-Bradley(**Rockwell**)** PLC** = 179 179 180 - 181 -= Create communication with Allen-Bradley(**Rockwell**)** PLC** = 182 - 183 183 == **DF1 Advanced Protocol** == 184 184 185 185 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 ... ... @@ -521,9 +521,8 @@ 521 521 ((( 522 522 The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. 523 523 522 +== **Ethernet DF1 Protocol** == 524 524 525 -= **Allen-Bradley Ethernet DF1** = 526 - 527 527 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 528 528 529 529 = Create communication with **Crouzet PLC** = ... ... @@ -530,7 +530,54 @@ 530 530 531 531 == **CROUZET M3 (FBD)** == 532 532 530 +**1)V-BOX setting** 533 533 532 +|=Item|=Recommended |=Note 533 +|=Protocol|CROUZET M3 (FBD)| 534 +|=Connection|RS232| 535 +|=Baud rate|115200| 536 +|=Stop bits|1| 537 +|=Data bits|7| 538 +|=Parity|EVEN| 539 + 540 +**2)Address List** 541 + 542 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note 543 +|(% rowspan="4" %)Bit|I|I DD|1~~99|Input 544 +|SLIBit|SLIBit DD.dd|1.0~~24.15|Serial Link Input 545 +|SLOBit|SLOBit DD.dd|25.0~~48.15|Serial Link Output(Read only) 546 +|State|State D|1~~1|PLC state(Read only) 547 +|(% rowspan="5" %)Word|AI|AI DD|1~~99|Analog Input 548 +|SLIn|SLIn DD|1~~24|Serial Link Input 549 +|SLOut|SLOut DD|25~~48|Serial Link Output(Read only) 550 +|Time|Time D|1~~6|((( 551 +Time1: Second 552 + 553 +Time2: Minute 554 + 555 +Time3: Hour 556 + 557 +Time4: Day 558 + 559 +Time5: Month 560 + 561 +Time6: Year 562 +))) 563 +|Order|Order D|1~~1|((( 564 +Running command(Write only) 565 + 566 +~=2: Run mode; =1: Stop mode; 567 +))) 568 + 569 +**3)Cable Wiring** 570 + 571 +(% style="text-align:center" %) 572 +[[image:CrouzetRS232 VBox.png]] 573 + 574 +{{info}} 575 +**✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details. 576 +{{/info}} 577 + 534 534 = Create communication with **Siemens PLC** = 535 535 536 536 == **S7-200 Smart Ethernet Protocol** ==
- CrouzetRS232 VBox.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.9 KB - Content