Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Bob - Content
-
... ... @@ -176,10 +176,8 @@ 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 178 178 179 += Create communication with **Rockwell PLC** = 179 179 180 - 181 -= Create communication with Allen-Bradley(**Rockwell**)** PLC** = 182 - 183 183 == **DF1 Advanced Protocol** == 184 184 185 185 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 ... ... @@ -276,12 +276,8 @@ 276 276 (% style="text-align:center" %) 277 277 [[image:ABRS232.gif]] 278 278 279 -(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %) 280 -(% id="cke_bm_5621S" style="display:none" %)** ** 277 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 281 281 282 -== **MicroLogix Protocol** == 283 - 284 -(% class="wikigeneratedid" %) 285 285 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 286 286 287 287 **1)V-BOX setting** ... ... @@ -526,13 +526,7 @@ 526 526 527 527 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 528 528 529 -= Create communication with **Crouzet PLC** = 530 530 531 -== **CROUZET M3 (FBD)** == 532 - 533 -**1)V-BOX setting** 534 - 535 - 536 536 = Create communication with **Siemens PLC** = 537 537 538 538 == **S7-200 Smart Ethernet Protocol** == ... ... @@ -789,24 +789,13 @@ 789 789 790 790 {{code language="LUA"}} 791 791 function init.main() 792 -addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address 793 -addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address 780 + addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address 781 + 782 + addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address 783 + 794 794 end 795 795 {{/code}} 796 796 797 -Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 798 - 799 -**✎Note:** 800 - 801 -* **Communication port configuration: ** 802 -** Continuous length needs to be set to 0. 803 -** Integration interval needs to be set to 1. (no change may result in data errors) 804 -** Set Port and Device Station NO. 805 -** Other set as defaulted. 806 -* **Notes on the use of registers:** 807 -** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc. 808 -** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 ) 809 - 810 810 = Create communication with **Mitsubishi PLC** = 811 811 812 812 == **FX1S,1N,2N Serial Protocol** ==