Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 216.1
edited by Hunter
on 2023/03/18 15:45
Change comment: There is no comment for this version
To version 207.1
edited by Bob
on 2023/02/02 11:57
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Bob
Content
... ... @@ -176,10 +176,8 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 += Create communication with **Rockwell PLC** =
179 179  
180 -
181 -= Create communication with Allen-Bradley(**Rockwell**)** PLC** =
182 -
183 183  == **DF1 Advanced Protocol** ==
184 184  
185 185  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5
... ... @@ -276,12 +276,8 @@
276 276  (% style="text-align:center" %)
277 277  [[image:ABRS232.gif]]
278 278  
279 -(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %)
280 -(% id="cke_bm_5621S" style="display:none" %)** **
277 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
281 281  
282 -== **MicroLogix Protocol** ==
283 -
284 -(% class="wikigeneratedid" %)
285 285  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
286 286  
287 287  **1)V-BOX setting**
... ... @@ -526,13 +526,7 @@
526 526  
527 527  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
528 528  
529 -= Create communication with **Crouzet PLC** =
530 530  
531 -== **CROUZET M3 (FBD)** ==
532 -
533 -**1)V-BOX setting**
534 -
535 -
536 536  = Create communication with **Siemens PLC** =
537 537  
538 538  == **S7-200 Smart Ethernet Protocol** ==
... ... @@ -789,24 +789,13 @@
789 789  
790 790  {{code language="LUA"}}
791 791  function init.main()
792 -addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
793 -addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
780 +    addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
781 +
782 +    addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
783 +
794 794  end
795 795  {{/code}}
796 796  
797 -Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code.
798 -
799 -**✎Note:**
800 -
801 -* **Communication port configuration: **
802 -** Continuous length needs to be set to 0.
803 -** Integration interval needs to be set to 1. (no change may result in data errors)
804 -** Set Port and Device Station NO.
805 -** Other set as defaulted.
806 -* **Notes on the use of registers:**
807 -** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
808 -** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
809 -
810 810  = Create communication with **Mitsubishi PLC** =
811 811  
812 812  == **FX1S,1N,2N Serial Protocol** ==