Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 6 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -176,8 +176,6 @@ 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 178 178 179 - 180 - 181 181 = Create communication with Allen-Bradley(**Rockwell**)** PLC** = 182 182 183 183 == **DF1 Advanced Protocol** == ... ... @@ -521,9 +521,8 @@ 521 521 ((( 522 522 The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. 523 523 522 +== **Ethernet DF1 Protocol** == 524 524 525 -= **Allen-Bradley Ethernet DF1** = 526 - 527 527 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 528 528 529 529 = Create communication with **Crouzet PLC** = ... ... @@ -530,9 +530,56 @@ 530 530 531 531 == **CROUZET M3 (FBD)** == 532 532 530 +Support Series: Crouzet Millenium 3 CD12/CB12 531 + 533 533 **1)V-BOX setting** 534 534 534 +|=Item|=Recommended |=Note 535 +|=Protocol|CROUZET M3 (FBD)| 536 +|=Connection|RS232| 537 +|=Baud rate|115200| 538 +|=Stop bits|1| 539 +|=Data bits|7| 540 +|=Parity|EVEN| 535 535 542 +**2)Address List** 543 + 544 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note 545 +|(% rowspan="4" %)Bit|I|I DD|1~~99|Input 546 +|SLIBit|SLIBit DD.dd|1.0~~24.15|Serial Link Input 547 +|SLOBit|SLOBit DD.dd|25.0~~48.15|Serial Link Output(Read only) 548 +|State|State D|1~~1|PLC state(Read only) 549 +|(% rowspan="5" %)Word|AI|AI DD|1~~99|Analog Input 550 +|SLIn|SLIn DD|1~~24|Serial Link Input 551 +|SLOut|SLOut DD|25~~48|Serial Link Output(Read only) 552 +|Time|Time D|1~~6|((( 553 +Time1: Second 554 + 555 +Time2: Minute 556 + 557 +Time3: Hour 558 + 559 +Time4: Day 560 + 561 +Time5: Month 562 + 563 +Time6: Year 564 +))) 565 +|Order|Order D|1~~1|((( 566 +Running command(Write only) 567 + 568 +~=2: Run mode; =1: Stop mode; 569 +))) 570 + 571 +**3)Cable Wiring** 572 + 573 +(% style="text-align:center" %) 574 +[[image:CrouzetRS232 VBox.png]] 575 + 576 +{{info}} 577 +**✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details. 578 +{{/info}} 579 + 536 536 = Create communication with **Siemens PLC** = 537 537 538 538 == **S7-200 Smart Ethernet Protocol** == ... ... @@ -1952,6 +1952,23 @@ 1952 1952 (% style="text-align:center" %) 1953 1953 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 1954 1954 1999 +== **Communicate with Modbus Meter** == 2000 + 2001 +The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication. 2002 + 2003 +~1. Wiring the RS485 cable first. Because the pin 58 is A, the pin 59 is B for meter. Here we use the COM1 to connect. So the diagram like follows: 2004 + 2005 +(% style="text-align:center" %) 2006 +[[image:LinfeeTerminalDiagram.png]] 2007 + 2008 +2. Check the specific Modbus parameter in the communication menu from LED display. 2009 + 2010 +So from the following pictures, we can know the Meter Address is 85, Baud rate is 9600, CRC None. 2011 + 2012 + 2013 +(% style="text-align:center" %) 2014 +[[image:MeterModbusAllView.png]] 2015 + 1955 1955 == **MODBUS RTU Master** == 1956 1956 1957 1957 Select the protocol "Modbus RTU Master",
- CrouzetRS232 VBox.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.9 KB - Content
- LinfeeTerminalDiagram.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.6 KB - Content
- MeterModbusAddr.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +562.5 KB - Content
- MeterModbusAllView.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.6 MB - Content
- MeterModbusBaud.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +444.0 KB - Content
- MeterModbusPara.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +532.0 KB - Content