Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -519,9 +519,8 @@ 519 519 ((( 520 520 The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. 521 521 522 +== **Ethernet DF1 Protocol** == 522 522 523 -= **Allen-Bradley Ethernet DF1** = 524 - 525 525 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 526 526 527 527 = Create communication with **Crouzet PLC** = ... ... @@ -528,9 +528,56 @@ 528 528 529 529 == **CROUZET M3 (FBD)** == 530 530 530 +Support Series: Crouzet Millenium 3 CD12/CB12 531 + 531 531 **1)V-BOX setting** 532 532 534 +|=Item|=Recommended |=Note 535 +|=Protocol|CROUZET M3 (FBD)| 536 +|=Connection|RS232| 537 +|=Baud rate|115200| 538 +|=Stop bits|1| 539 +|=Data bits|7| 540 +|=Parity|EVEN| 533 533 542 +**2)Address List** 543 + 544 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note 545 +|(% rowspan="4" %)Bit|I|I DD|1~~99|Input 546 +|SLIBit|SLIBit DD.dd|1.0~~24.15|Serial Link Input 547 +|SLOBit|SLOBit DD.dd|25.0~~48.15|Serial Link Output(Read only) 548 +|State|State D|1~~1|PLC state(Read only) 549 +|(% rowspan="5" %)Word|AI|AI DD|1~~99|Analog Input 550 +|SLIn|SLIn DD|1~~24|Serial Link Input 551 +|SLOut|SLOut DD|25~~48|Serial Link Output(Read only) 552 +|Time|Time D|1~~6|((( 553 +Time1: Second 554 + 555 +Time2: Minute 556 + 557 +Time3: Hour 558 + 559 +Time4: Day 560 + 561 +Time5: Month 562 + 563 +Time6: Year 564 +))) 565 +|Order|Order D|1~~1|((( 566 +Running command(Write only) 567 + 568 +~=2: Run mode; =1: Stop mode; 569 +))) 570 + 571 +**3)Cable Wiring** 572 + 573 +(% style="text-align:center" %) 574 +[[image:CrouzetRS232 VBox.png]] 575 + 576 +{{info}} 577 +**✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details. 578 +{{/info}} 579 + 534 534 = Create communication with **Siemens PLC** = 535 535 536 536 == **S7-200 Smart Ethernet Protocol** == ... ... @@ -1950,6 +1950,39 @@ 1950 1950 (% style="text-align:center" %) 1951 1951 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 1952 1952 1999 +== **Communicate with Modbus Meter** == 2000 + 2001 +The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication. 2002 + 2003 +~1. Wiring the RS485 cable first. Because the pin 58 is A, the pin 59 is B for meter. Here we use the COM1 to connect. So the diagram like follows: 2004 + 2005 +(% style="text-align:center" %) 2006 +[[image:LinfeeTerminalDiagram.png]] 2007 + 2008 +2. Check the specific Modbus parameter in the communication menu from LED display. 2009 + 2010 +So from the following pictures, we can know the Meter Address is 85, Baud rate is 9600, CRC None. 2011 + 2012 +{{info}} 2013 +**✎Note: **Meter address usually corresponding to the Modbus Slave Station No. on the Modbus communication. 2014 +{{/info}} 2015 + 2016 +(% style="text-align:center" %) 2017 +[[image:MeterModbusAllView.png]] 2018 + 2019 +(% class="wikigeneratedid" %) 2020 +3. Set up the communication in the Configuration tab. 2021 + 2022 +(% class="wikigeneratedid" %) 2023 +Select the protocol as **ModBus RTU Slave (All Function)**. And set the communication parameters like below. 2024 + 2025 +(% style="text-align:center" %) 2026 +[[image:VNETCommunicationtabmeter.png]] 2027 + 2028 +(% class="wikigeneratedid" %) 2029 +4. Create new real-time monitoring tag. 2030 + 2031 + 1953 1953 == **MODBUS RTU Master** == 1954 1954 1955 1955 Select the protocol "Modbus RTU Master",
- CrouzetRS232 VBox.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.9 KB - Content
- LinfeeTerminalDiagram.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.6 KB - Content
- MeterModbusAddr.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +562.5 KB - Content
- MeterModbusAllView.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.6 MB - Content
- MeterModbusBaud.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +444.0 KB - Content
- MeterModbusPara.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +532.0 KB - Content
- VNETCommunicationtabmeter.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.0 KB - Content