Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 217.1
edited by Hunter
on 2023/03/18 15:47
Change comment: There is no comment for this version
To version 143.1
edited by Ben
on 2022/08/31 16:10
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Ben
Content
... ... @@ -176,116 +176,16 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 -= Create communication with Allen-Bradley(**Rockwell**)** PLC** =
179 += Create communication with **Rockwell PLC** =
180 180  
181 -== **DF1 Advanced Protocol** ==
181 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
182 182  
183 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5
184 -
185 -**1) V-Box Settings**
186 -
187 -|=Item|=Recommended |=Note
188 -|=Protocol|Allen Bradley DF1 Advanced|
189 -|=Connection|RS232|
190 -|=Baud rate|19200|
191 -|=Stop bits|1|
192 -|=Data bits|8|
193 -|=Parity|None|
194 -|=PLC Station No.|1|
195 -|=HMI Station No.|0|
196 -
197 -**2) Address List**
198 -
199 -|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note
200 -|(% colspan="1" rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1
201 -|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0
202 -|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2
203 -|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3
204 -|BN|BNddddd.dd|0.0~~99255.15|(((
205 -Bit data file B0~~B99
206 -
207 -First two digits is for file number
208 -
209 -For example, BN13001.00 represents file number B13, address 001, the 0th bit.
210 -)))
211 -|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7
212 -|NN|NNddddd.dd|0.0~~99255.15|(((
213 -Integer data file bit format N0~~N99
214 -
215 -First two digits is for file number
216 -
217 -For example, NN13001.00 represents file number N13, address 001, the 0th bit.
218 -)))
219 -|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2
220 -|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value)
221 -|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value)
222 -|TNS|TNSddddd|0~~99255|(((
223 -Timer Preset Value
224 -
225 -First two digits is for file number
226 -
227 -For example, TNS99255 represents file number T99, address 255.
228 -)))
229 -|TNP|TNPddddd|0~~99255|(((
230 -Timer Accumulator Value
231 -
232 -First two digits is for file number
233 -
234 -For example, TNP99255 represents file number T99, address 255.
235 -)))
236 -|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value)
237 -|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value)
238 -|CNS|CNSddddd|0~~99255|(((
239 -Counter Preset Value
240 -
241 -First two digits is for file number
242 -
243 -For example, CNS99255 represents file number C99, address 255.
244 -)))
245 -|CNP|CNPddddd|0~~99255|(((
246 -Counter Accumulator Value
247 -
248 -First two digits is for file number
249 -
250 -For example, CNP99255 represents file number C99, address 255.
251 -)))
252 -|N7|N7ddd|0~~255|Only able to communicate with file number N7
253 -|NN|NNddd|0~~99255|(((
254 -Integer data file
255 -
256 -First two digits is for file number
257 -
258 -For example, NN99255 represents file number N99, address 255.
259 -)))
260 -|(% colspan="1" rowspan="3" %)Double Word|F8|F8ddd|0~~255|(((
261 -Only able to communicate with file number N7
262 -)))
263 -|FN|FNddddd|0~~99255|(((
264 -Floating point data file
265 -
266 -First two digits is for file number
267 -
268 -For example, FN99255 represents file number F99, address 255.
269 -)))
270 -|LN|LNddddd|0~~99255|Long
271 -
272 -**3) Cable Wiring**
273 -
274 -(% style="text-align:center" %)
275 -[[image:ABRS232.gif]]
276 -
277 -(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %)
278 -(% id="cke_bm_5621S" style="display:none" %)** **
279 -
280 -== **MicroLogix Protocol** ==
281 -
282 -(% class="wikigeneratedid" %)
283 283  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
284 284  
285 -**1)V-BOX setting**
185 +**1)PLC Settings**
286 286  
287 287  |**Item**|**Settings**|**Note**
288 -|Protocol|Allen-Bradley DF1 Advanced|
188 +|Protocol|Allen-Bradlley DF1 Advanced|
289 289  |Connection|RS232|
290 290  |Baud rate|19200|
291 291  |Data bit|8|
... ... @@ -519,17 +519,12 @@
519 519  (((
520 520  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
521 521  
422 +
522 522  == **Allen-Bradley Ethernet DF1** ==
523 523  
524 524  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
525 525  
526 -= Create communication with **Crouzet PLC** =
527 527  
528 -== **CROUZET M3 (FBD)** ==
529 -
530 -**1)V-BOX setting**
531 -
532 -
533 533  = Create communication with **Siemens PLC** =
534 534  
535 535  == **S7-200 Smart Ethernet Protocol** ==
... ... @@ -541,7 +541,7 @@
541 541  
542 542  Supported Series: Siemens S7-300 series PLC
543 543  
544 -**1)V-BOX setting**
439 +**1)PLC Setting**
545 545  
546 546  |**Items**|**Settings**|**Note**
547 547  |Protocol|Simens S7-300 Ethernet|
... ... @@ -603,7 +603,7 @@
603 603  
604 604  Supported Series: Siemens S7-400, S7-1200 and S7-1500
605 605  
606 -**1)V-BOX setting**
501 +**1)PLC Setting**
607 607  
608 608  |=**Items**|=**Settings**|=**Note**
609 609  |Protocol|Siemens S7-XXX|
... ... @@ -713,97 +713,6 @@
713 713  
714 714  [[image:image-20220824162342-2.png]]
715 715  
716 -== **LOGO Ethernet Protocol** ==
717 -
718 -Supported Series: Siemens Logo 0BA0, 0BA1 series
719 -
720 -**V-BOX Settings**
721 -
722 -
723 -|**Items**|**Settings**|**Note**
724 -|Protocol|Siemens LOGO|
725 -|Connection|Ethernet|
726 -|Port No.|102|
727 -|PLC station No.|2|
728 -
729 -**Address List**
730 -
731 -
732 -|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
733 -|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
734 -|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
735 -|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
736 -|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
737 -|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
738 -|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
739 -|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
740 -|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
741 -|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
742 -|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
743 -|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
744 -|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
745 -|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
746 -|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
747 -|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
748 -
749 -**PLC Settings in LOGO Software:**
750 -
751 -Click [Tools]~-~-[Ethernet Connections],shown as below.
752 -
753 -(% style="text-align:center" %)
754 -[[image:PIStudio.12\.PLC protocols.WebHome@12.PLC Protocol_html_8b9d2322edf89519.png]]
755 -
756 -Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
757 -
758 -(% style="text-align:center" %)
759 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228142937-4.png]]
760 -
761 -**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
762 -
763 -(% style="text-align:center" %)
764 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143047-5.png]]
765 -
766 - **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
767 -
768 -(% style="text-align:center" %)
769 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143246-6.png]]
770 -
771 -**V-BOX Communication Settings**
772 -
773 -Set PLC IP in [IP Address] settings;
774 -
775 -(% style="text-align:center" %)
776 -[[image:LldwDGntf4.png]]
777 -
778 -Enable V-BOX Ethernet in [Network];
779 -
780 -(% style="text-align:center" %)
781 -[[image:WgvjfWbQif.png]]
782 -
783 -TSAP setting
784 -
785 -* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful.
786 -
787 -{{code language="LUA"}}
788 -function init.main()
789 -addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
790 -addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
791 -end
792 -{{/code}}
793 -
794 -Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code.
795 -
796 -**✎Note:**
797 -
798 -* **Communication port configuration: **
799 -** Continuous length needs to be set to 0.
800 -** Integration interval needs to be set to 1. (no change may result in data errors)
801 -** Set Port and Device Station NO.
802 -** Other set as defaulted.
803 -* **Notes on the use of registers:**
804 -** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
805 -** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
806 -
807 807  = Create communication with **Mitsubishi PLC** =
808 808  
809 809  == **FX1S,1N,2N Serial Protocol** ==
... ... @@ -900,101 +900,6 @@
900 900  [[image:image-20220825100845-4.png]]
901 901  
902 902  
903 -== **FX3U Ethernet Protocol** ==
904 -
905 -Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
906 -
907 -**1)V-BOX Settings**
908 -
909 -|Items|Settings|Note
910 -|Protocol|Mitsubishi FX3U|
911 -|Connection|Ethernet|
912 -|Port No.|5009|Must be the same as the PLC setting
913 -|PLC station No.|0|
914 -
915 -**2)Address List**
916 -
917 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
918 -|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377|
919 -|Y|Y|Y OOO|0~~377|
920 -|M|M|M DDDD|0~~7679|
921 -|SM|SM|SM DDDD|8000~~8511|
922 -|S|S|S DDDD|0~~4095|
923 -|TS|TS|TS DDD|0~~511|
924 -|CS|CS|CS DDD|0~~255|
925 -|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199|
926 -|TN|TN|TN DDD|0~~511|
927 -|D|D|D DDDD|0~~7999|
928 -|SD|SD|SD DDDD|8000~~8511|
929 -|R|R|R DDDDD|0~~32767|
930 -
931 -**3)Ethernet Module Settings**
932 -
933 -FX3U-ENET-L module configuration
934 -Set up the FX3U-ENET-L Ethernet module settings as follows.
935 -Select the module location, which in this document is Module 0.
936 -
937 -[[image:image-20221116105850-1.png]]
938 -
939 -Select "Operational setting" to enter the following screen.
940 -
941 -The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
942 -
943 -[[image:image-20221116105947-1.png]]
944 -
945 -Select "Open setting" to enter the setting interface, the settings are as follows.
946 -
947 -The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
948 -
949 -Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
950 -
951 -[[image:image-20221116110802-1.png]]
952 -
953 -Click on "transter setup" - "PC side I/F setting", see the following figure.
954 -
955 -After setting, the first download must use the programming cable, as shown in the figure; after that, can
956 -
957 -use the IP set in the "Ethernet board" to communicate directly with the network cable.
958 -
959 -[[image:image-20221116110832-2.png||height="423" width="708"]]
960 -
961 -Read and write data from the Ethernet module
962 -
963 -[[image:image-20221116110907-3.png]]
964 -
965 -Set "Transter setup" to COM communication, and read or write operation as shown below
966 -
967 -[[image:image-20221116110917-4.png]]
968 -
969 -**4)PLC Settings (GX Works 2)**
970 -
971 -Create a blank FX5U project
972 -
973 -Find Current Connection in the navigation
974 -
975 -[[image:image-20221116111427-1.png||height="421" width="705"]]
976 -
977 -Select Connection Channel List
978 -
979 -Select Ethernet board communication
980 -
981 -[[image:image-20221116111451-2.png||height="421" width="705"]]
982 -
983 -Select Ethernet Module
984 -Set the IP address of the PLC
985 -
986 -[[image:image-20221116111509-3.png||height="666" width="699"]]
987 -
988 -Read or write PLC data, in this document is read
989 -
990 -[[image:image-20221116111651-4.png||height="416" width="697"]]
991 -
992 -[[image:image-20221116111727-5.png||height="416" width="697"]]
993 -
994 -**4)Configure the communication protocol**
995 -
996 -[[image:image-20221119101946-2.png||height="395" width="695"]]
997 -
998 998  == **FX5U Serial Protocol** ==
999 999  
1000 1000  Mitsubishi FX5U series PLC
... ... @@ -1149,10 +1149,11 @@
1149 1149  
1150 1150  [[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]]
1151 1151  
1152 -**5)Cable Wiring**
861 +**5)电缆布线**
1153 1153  
1154 1154  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1155 1155  
865 +
1156 1156  == **L02 Serial Protocol** ==
1157 1157  
1158 1158  Mitsubishi L02 series CPU built-in serial port.
... ... @@ -1286,12 +1286,6 @@
1286 1286  
1287 1287  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1288 1288  
1289 -== **Q12H Serial Protocol** ==
1290 -
1291 -This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
1292 -
1293 -[[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]
1294 -
1295 1295  == **QJ71E71 Ethernet Protocol** ==
1296 1296  
1297 1297  Mitsubishi QJ71E71 Ethernet communication module;
... ... @@ -1340,13 +1340,10 @@
1340 1340  
1341 1341  * Click [Ethernet/CC IE/MELSECNET];
1342 1342  * Please select [Ethernet] as network type;
1343 -* Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
1047 +* Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order);
1344 1344  * Select [Online] as Mode;
1345 -* [[image:image-20221119171343-2.png||height="341" width="587"]]
1346 1346  * Click [Operation setting] to set IP;
1347 1347  * Select [Binary Code] as [Communication Data Code];
1348 -* [[image:image-20221119171436-3.png||height="354" width="588"]]
1349 -* Click [Open setting]
1350 1350  * Set protocol: TCP;
1351 1351  * Set [unpassive] in [Open system];
1352 1352  * Set [receive] in [Fixed buffer];
... ... @@ -1353,16 +1353,14 @@
1353 1353  * Set [procedure Exist] in [Fixed buffer communication];
1354 1354  * Disable [Pairing open];
1355 1355  * Set [No confirm] in [Existence confirmation];
1356 -* Host station port number: 5009;
1057 +* Host station port number: 1025;
1357 1357  * Save settings;
1358 -* [[image:image-20221119171611-4.png||height="354" width="588"]]
1359 1359  * Download project into PLC and restart it
1360 1360  
1361 1361  **4)Configure the communication protocol**
1362 1362  
1363 -[[image:image-20221119171832-5.png||height="354" width="625"]]
1063 +[[image:image-20220825143728-1.png]]
1364 1364  
1365 -
1366 1366  **5)Cable Wiring**
1367 1367  
1368 1368  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
... ... @@ -1371,105 +1371,12 @@
1371 1371  
1372 1372  == **DVP Ethernet Protocol** ==
1373 1373  
1374 -Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module
1073 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1375 1375  
1376 -**1)V-BOX Settings**
1377 -
1378 -|=**Items**|=**Settings**|=**Note**
1379 -|Protocol|DELTA DVP MODBUS TCP|
1380 -|Connection|Ethernet|
1381 -|Port No.|502|
1382 -|Device No.|1|
1383 -|VBox Device No.|0|
1384 -
1385 -**2)Address List **
1386 -
1387 -|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note**
1388 -|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOO|(% style="width:225px" %)0~~377|
1389 -|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOO|(% style="width:225px" %)0~~377|
1390 -|Bit|(% style="width:191px" %)M0|(% style="width:217px" %)M0|(% style="width:168px" %)M0DDDD|(% style="width:225px" %)0~~1535|
1391 -|Bit|(% style="width:191px" %)M1|(% style="width:217px" %)M1|(% style="width:168px" %)M1DDDD|(% style="width:225px" %)1536~~4096|
1392 -|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255|
1393 -|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~255|
1394 -|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDD|(% style="width:225px" %)0~~1023|
1395 -|Word|(% style="width:191px" %)D0|(% style="width:217px" %)D0|(% style="width:168px" %)D0DDDD|(% style="width:225px" %)0~~4095|
1396 -|Word|(% style="width:191px" %)D1|(% style="width:217px" %)D1|(% style="width:168px" %)D1DDDD|(% style="width:225px" %)4096~~11999|
1397 -|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255|
1398 -|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199|
1399 -|Double Word|(% style="width:191px" %)HC|(% style="width:217px" %)HC|(% style="width:168px" %)HCDDD|(% style="width:225px" %)200~~255|
1400 -
1401 -**3) PLC Setting:**
1402 -
1403 -~1. Create new project in Delta WPL Soft, and click Setting to open the communication settings:
1404 -
1405 -(% style="text-align:center" %)
1406 -[[image:DVPEthernetWPLSoft2.png]]
1407 -
1408 -2. Set up the communication type and PLC IP:
1409 -
1410 -(% style="text-align:center" %)
1411 -[[image:DVPEthernetSetup.png]]
1412 -
1413 -(% class="wikigeneratedid" %)
1414 -3. Click OK and save the settings. Then click Communication on toolbar, then click Transfer Setup to open new window:
1415 -
1416 -(% style="text-align:center" %)
1417 -[[image:DVPEthernetTransfer.png]]
1418 -
1419 -(% class="wikigeneratedid" %)
1420 -4. Select Communication Mode as PC => PLC to download or select PC <=PLC to upload:
1421 -
1422 -(% style="text-align:center" %)
1423 -[[image:DVPEthernetPLCtoPC.png]]
1424 -
1425 -5. Click Auto-Search Ethernet Module to find the PLC on the same LAN network:
1426 -
1427 -(% style="text-align:center" %)
1428 -[[image:DVPEthernetAutoSearch.png]]
1429 -
1430 -**4) V-BOX Setting:**
1431 -
1432 -Set the same IP address according to the setting from WPL Soft:
1433 -
1434 -(% style="text-align:center" %)
1435 -[[image:DVPEthernetVNETPortocol.png]]
1436 -
1437 1437  == **DVP serial protocol** ==
1438 1438  
1439 -Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX
1077 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1440 1440  
1441 -**1)V-BOX Settings**
1442 -
1443 -|=**Items**|=**Settings**|=**Note**
1444 -|Protocol|DELTA DVP PROTOCOL|
1445 -|Connection|RS232|
1446 -|Baud Rate|9600|
1447 -|Stop Bit|1|
1448 -|Data Bit|7|
1449 -|Parity|EVEN|
1450 -|Device No.|1|
1451 -
1452 -(% class="wikigeneratedid" %)
1453 -**2)Address List**
1454 -
1455 -|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note**
1456 -|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOOOOO|(% style="width:225px" %)0~~303237|
1457 -|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOOOOO|(% style="width:225px" %)0~~303237|
1458 -|Bit|(% style="width:191px" %)M|(% style="width:217px" %)M|(% style="width:168px" %)MDDDDD|(% style="width:225px" %)0~~99999|
1459 -|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999|
1460 -|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)0~~99999|
1461 -|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDDD|(% style="width:225px" %)0~~99999|
1462 -|Word|(% style="width:191px" %)D|(% style="width:217px" %)D|(% style="width:168px" %)D DDDDD|(% style="width:225px" %)0~~99999|
1463 -|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999|
1464 -|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199|
1465 -|Double Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)200~~99999|
1466 -
1467 -(% class="wikigeneratedid" %)
1468 -**3)Wiring Diagram**
1469 -
1470 -(% style="text-align:center" %)
1471 -[[image:Delta DVP PROTOCOLSerial232.png]]
1472 -
1473 1473  == **AS Ethernet Protocol** ==
1474 1474  
1475 1475  **1)V-BOX Settings**
... ... @@ -1503,6 +1503,7 @@
1503 1503  
1504 1504  **3)Configure the communication protocol**
1505 1505  
1112 +
1506 1506  [[image:image-20220831160010-4.png]]
1507 1507  
1508 1508  **4)Cable Wiring**
... ... @@ -1526,7 +1526,7 @@
1526 1526  [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1527 1527  
1528 1528  
1529 -== **EC55 Series Protocol** ==
1136 +== **EC55 Protocol** ==
1530 1530  
1531 1531  Supported device: EC55 temperature instrument
1532 1532  
... ... @@ -1585,363 +1585,12 @@
1585 1585  * Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document.
1586 1586  * When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable.
1587 1587  * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1588 -* [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1195 +* [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_d428cad280fdefb3.png?width=347&height=276&rev=1.1||alt="12.PLC Protocol_html_d428cad280fdefb3.png" height="276" width="347"]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1589 1589  
1590 -= Create communication with Xinje** PLC** =
1197 += Create communication with **Modbus RTU** =
1591 1591  
1592 -== **XC serial protocol** ==
1199 +== **V-BOX as Slave** ==
1593 1593  
1594 -**1)V-BOX Settings**
1595 -
1596 -|**Item**|**Settings**|**Note**
1597 -|Protocol|XINJE XC MODBUS|
1598 -|Connection|RS232|
1599 -|Baud rate|19200|
1600 -|Data bit|8|
1601 -|Parity|EVEN|
1602 -|Stop bit|1|
1603 -|PLC station No.|1|
1604 -
1605 -**2)Address List**
1606 -
1607 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1608 -|Bit|M|M|M d|0~~8511|
1609 -|Bit|X|X|X o|0~~1747|
1610 -|Bit|Y|Y|Y o|0~~1747|
1611 -|Bit|S|S|S d|0~~1023|
1612 -|Bit|T|T|T d|0~~4095|
1613 -|Bit|C|C|C d|0~~634|
1614 -|Word|D|D|D d|0~~8511|
1615 -|Word|TD|TD|TD d|0~~618|
1616 -|Word|CD|CD|CD d|0~~634|
1617 -|Word|FD|FD|FD d|0~~8511|
1618 -
1619 -**3)Configure the communication protocol**
1620 -
1621 -
1622 -[[image:image-20220831163041-1.png]]
1623 -
1624 -**4)Cable Wiring**
1625 -
1626 -Figure
1627 -
1628 -[[image:image-20220831163406-2.png]][[image:image-20220831163422-3.png]]
1629 -
1630 -Pin Definition Diagram
1631 -
1632 -[[image:image-20220831163441-4.png]]
1633 -
1634 -== **XD serial protocol** ==
1635 -
1636 -**1)V-BOX Settings**
1637 -
1638 -Supported Series: Xinjie XD/XE Series PLC
1639 -
1640 -|**Item**|**Settings**|**Note**
1641 -|Protocol|XINJE XD/XC MODBUS|
1642 -|Connection|RS232|
1643 -|Baud rate|19200|
1644 -|Data bit|8|
1645 -|Parity|EVEN|
1646 -|Stop bit|1|
1647 -|PLC station No.|1|
1648 -
1649 -**2)Address List**
1650 -
1651 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1652 -|Bit|M|M|M d|0~~74999|
1653 -|Bit|X1xx|X1xx|X1xx o|0~~1177|
1654 -|Bit|X2xx|X2xx|X2xx o|0~~277|
1655 -|Bit|X|X|X o|0~~77|
1656 -|Bit|Y1xx|Y1xx|Y1xx o|0~~1177|
1657 -|Bit|Y2xx|Y2xx|Y2xx o|0~~277|
1658 -|Bit|Y|Y|Y o|0~~4095|
1659 -|Bit|SM|SM|SM d|0~~4999|(((
1660 -
1661 -)))
1662 -|Bit|T|T|T d|0~~4999|
1663 -|Bit|C|C|C d|0~~4999|
1664 -|Bit|ET|ET|ET d|0~~31|
1665 -|Bit|SE|SE|SE d|0~~31|
1666 -|Bit|HM|HM|HM d|0~~11999|
1667 -|Bit|HSC|HSC|HSC d|0~~39|
1668 -|Bit|HS|HS|HS d|0~~999|
1669 -|Bit|HT|HT|HT d|0~~1999|
1670 -|Bit|HC|HC|HC d|0~~1999|
1671 -|Bit|S|S|S d|0~~7999|
1672 -|Word|D|D|D d|0~~69999|
1673 -|Word|ID|ID|ID d|0~~99|
1674 -|Word|ID1xx|ID1xx|ID1xx d|0~~999|
1675 -|Word|ID2xx|ID2xx|ID2xx d|0~~299|
1676 -|Word|QD|QD|QD d|0~~99|
1677 -|Word|QD1xx|QD1xx|QD1xx d|0~~999|
1678 -|Word|QD2xx|QD2xx|QD2xx d|0~~299|
1679 -|Word|SD|SD|SD d|0~~4999|
1680 -|Word|TD|TD|TD d|0~~575|
1681 -|Word|CD|CD|CD d|0~~575|
1682 -|Word|ETD|ETD|ETD d|0~~31|
1683 -|Word|HD|HD|HD d|0~~24999|
1684 -|Word|HSD|HSD|HSD d|0~~1023|
1685 -|Word|HTD|HTD|HTD d|0~~95|
1686 -|Word|HCD|HCD|HCD d|0~~95|
1687 -|Word|HSCD|HSCD|HSCD d|0~~31|
1688 -|Word|FD|FD|FD d|0~~8191|
1689 -|Word|SFD|SFD|SFD d|0~~5999|
1690 -|Word|FS|FS|FS d|0~~47|
1691 -
1692 -**3)Configure the communication protocol**
1693 -
1694 -[[image:image-20220831163923-7.png]]
1695 -
1696 -
1697 -
1698 -**4)Cable Wiring**
1699 -
1700 -Figure
1701 -
1702 -[[image:image-20220831163406-2.png]][[image:image-20220831163553-6.png]]
1703 -
1704 -Pin Definition Diagram
1705 -
1706 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1707 -
1708 -= Create communication with **Schneider PLC** =
1709 -
1710 -== **Schneider MODBUS RTU** ==
1711 -
1712 -**1)V-BOX Setting**
1713 -
1714 -|=**Parameters**|=**Recommended**|=**Notes**
1715 -|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU|
1716 -|**Connection**|RS485|
1717 -|**Baud rate**|19200|
1718 -|**Data bit**|8|
1719 -|**Parity**|Even|
1720 -|**Stop bit**|1|
1721 -|**PLC station No.**|1|
1722 -
1723 -**2)Address List**
1724 -
1725 -|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
1726 -|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only)
1727 -|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils
1728 -|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal)
1729 -|W|MW|DDDDDD|0 ~~ 999999|Output register
1730 -|DW|MD|DDDDDD|0 ~~ 999999|Output register
1731 -
1732 -**3)Configure the communication protocol**
1733 -
1734 -[[image:image-20220902104329-1.png]]
1735 -
1736 -**4)Cable Wiring**
1737 -
1738 -**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector.
1739 -
1740 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
1741 -
1742 -= Create communication with Inovance** PLC** =
1743 -
1744 -== **H3U serial protocol** ==
1745 -
1746 -**1)V-BOX Settings**
1747 -
1748 -|**Item**|**Settings**|**Note**
1749 -|Protocol|INOVANCE H3U PLC|
1750 -|Connection|RS422|
1751 -|Baud rate|9600|
1752 -|Data bit|7|
1753 -|Parity|EVEN|
1754 -|Stop bit|1|
1755 -|PLC station No.|0|
1756 -
1757 -**2)Address List**
1758 -
1759 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1760 -|Bit|X|X|X o|0~~303237|
1761 -|Bit|Y|Y|Y o|0~~303237|
1762 -|Bit|M|M|M d|0~~99999|
1763 -|Bit|T|T|T d|0~~99999|
1764 -|Bit|C|C|C d|0~~99999|
1765 -|Bit|SM|SM|SM d|8000~~999|
1766 -|Bit|S|T|S d|0~~99999|
1767 -|Bit|Lamp|Lamp|Lamp d|0~~0|
1768 -|Word|X|X|X o|0~~303237|
1769 -|Word|Y|Y|Y o|0~~303237|
1770 -|Word|M|M|M d|0~~99999|
1771 -|Word|T|T|T d|0~~99999|
1772 -|Word|C|C|C d|0~~199|
1773 -|Word|D|D|D d|0~~7999|
1774 -|Word|S|S|S d|0~~99999|
1775 -|Word|SD|SD|SD d|8000~~9999|
1776 -|Word|R|R|R d|0~~32767|
1777 -
1778 -**3)Configure the communication protocol**
1779 -
1780 -[[image:image-20220831164626-1.png]]
1781 -
1782 -
1783 -
1784 -**4)Cable Wiring**
1785 -
1786 -Figure
1787 -
1788 -[[image:image-20220831164646-2.png]][[image:image-20220831164700-3.png]]
1789 -
1790 -Pin Definition Diagram
1791 -
1792 -[[image:image-20220831164731-4.png]]
1793 -
1794 -= Create communication with Panasonic** PLC** =
1795 -
1796 -== **FP serial protocol** ==
1797 -
1798 -**1)V-BOX Settings**
1799 -
1800 -|**Item**|**Settings**|**Note**
1801 -|Protocol|Panasonic FP MFWTOCOL|
1802 -|Connection|RS232|
1803 -|Baud rate|9600|
1804 -|Data bit|8|
1805 -|Parity|ODD|
1806 -|Stop bit|1|
1807 -|PLC station No.|1|
1808 -
1809 -**2)Address List**
1810 -
1811 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1812 -|Bit|X|X|X d|0~~9999|
1813 -|Bit|Y|Y|Y d|0~~9999|
1814 -|Bit|R|R|R d|0~~9999|
1815 -|Bit|T|T|T d|0~~9999|
1816 -|Bit|C|C|C d|0~~9999|
1817 -|Bit|L|L|L d|0~~9999|
1818 -|Word|WX|WX|WX d|0~~9999|
1819 -|Word|WY|WY|WY d|0~~9999|
1820 -|Word|WR|WR|WR d|0~~9999|
1821 -|Word|WL|WL|WL d|0~~9999|
1822 -|Word|LD|LD|LD d|0~~9999|
1823 -|Word|DT|DT|DT d|0~~65535|
1824 -|Word|FL|FL|FL d|0~~9999|
1825 -|Word|EV|EV|EV d|0~~9999|
1826 -|Word|SV|SV|SV d|0~~9999|
1827 -
1828 -**3)Configure the communication protocol**
1829 -
1830 -[[image:image-20220831165238-4.png]]
1831 -
1832 -
1833 -
1834 -**4)Cable Wiring**
1835 -
1836 -Figure
1837 -
1838 -[[image:image-20220831165031-3.png]][[image:image-20220831165017-2.png]]
1839 -
1840 -Pin Definition Diagram
1841 -
1842 -[[image:image-20220831165008-1.png]]
1843 -
1844 -= Create communication with LS** PLC** =
1845 -
1846 -== **XBC serial protocol** ==
1847 -
1848 -**1)V-BOX Settings**
1849 -
1850 -|**Item**|**Settings**|**Note**
1851 -|Protocol|LS XBC CNet|
1852 -|Connection|RS232|
1853 -|Baud rate|115200|
1854 -|Data bit|8|
1855 -|Parity|NONE|
1856 -|Stop bit|1|
1857 -|PLC station No.|1|
1858 -
1859 -**2)Address List**
1860 -
1861 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1862 -|Bit|P|P|P d|0~~2047|
1863 -|Bit|M|M|M d|0~~2047|
1864 -|Bit|L|L|L d|0~~11263|
1865 -|Bit|K|K|K d|0~~16183|
1866 -|Bit|F|F|F d|0~~2047|
1867 -|Bit|D|D|D d|0~~32767|
1868 -|Bit|R|R|R d|0~~32767|
1869 -|Bit|U|U|U d|0~~4095|
1870 -|Word|P|P|P d|0~~2047|
1871 -|Word|M|M|M d|0~~2047|
1872 -|Word|L|L|L d|0~~11263|
1873 -|Word|K|K|K d|0~~16183|
1874 -|Word|F|F|F d|0~~2047|
1875 -|Word|C|C|C d|0~~2047|
1876 -|Word|T|T|T d|0~~2047|
1877 -|Word|D|D|D d|0~~32767|
1878 -|Word|N|N|N d|0~~21503|
1879 -|Word|R|R|R d|0~~32767|
1880 -|Word|U|U|U d|0~~4095|
1881 -|Word|Z|Z|Z d|0~~127|
1882 -|Word|S|S|S d|0~~127|
1883 -
1884 -**3)Configure the communication protocol**
1885 -
1886 -[[image:image-20220831170147-1.png]]
1887 -
1888 -**4)Cable Wiring**
1889 -
1890 -Figure
1891 -
1892 -[[image:image-20220831170306-4.png]][[image:image-20220831170254-3.png]]
1893 -
1894 -Pin Definition Diagram
1895 -
1896 -[[image:image-20220831170215-2.png]]
1897 -
1898 -== **XGK FEnet Ethernet protocol** ==
1899 -
1900 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1901 -
1902 -**1)V-BOX Settings**
1903 -
1904 -|**Items**|**Settings**|**Note**
1905 -|Protocol|LG XGK FEnet(Ethernet)|
1906 -|Connection|Ethernet|
1907 -|Port No.|2004|
1908 -
1909 -**2)Address List**
1910 -
1911 -|**Type**|**Register**|**Range**|**Format**|**Note**
1912 -|(% rowspan="14" %)Word|P|0~~2047|P d|
1913 -|M|0~~2047|M d|
1914 -|K|0~~2047|K d|
1915 -|F|0~~2047|F d|
1916 -|T|0~~2047|T d|
1917 -|C|0~~2047|C d|
1918 -|Z|0~~127|Z d|
1919 -|S|0~~127|S d|
1920 -|L|0~~11263|L d|
1921 -|N|0~~21503|N d|
1922 -|D|0~~32767|D d|
1923 -|R|0~~32767|R d|
1924 -|ZR|0~~65535|ZR d|
1925 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
1926 -
1927 -**✎Note:**
1928 -
1929 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
1930 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
1931 -* All bit registers are in the form of bits in word, and the range is the same as the word register;
1932 -
1933 -**3)Communication Settings**
1934 -
1935 -[[image:image-20220831171127-1.png]]
1936 -
1937 -**4)Cable Wiring**
1938 -
1939 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1940 -
1941 -= Create communication with **Modbus ** =
1942 -
1943 -== **MODBUS RTU Slave (All function)** ==
1944 -
1945 1945  Select the protocol "Modbus RTU Slave (All Fuction)",
1946 1946  
1947 1947  Then set baud rate, port, stop bits, data bits, parity.
... ... @@ -1949,7 +1949,7 @@
1949 1949  (% style="text-align:center" %)
1950 1950  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
1951 1951  
1952 -== **MODBUS RTU Master** ==
1208 +== **V-BOX as Master** ==
1953 1953  
1954 1954  Select the protocol "Modbus RTU Master",
1955 1955  
... ... @@ -1961,8 +1961,8 @@
1961 1961  **address list**
1962 1962  
1963 1963  (% class="table-bordered" %)
1964 -|=(% scope="row" %)**Type**|=**Data Type**|=**Function code and description**
1965 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)
1220 +|**type**|**register**|**Function code and description**
1221 +|(% rowspan="11" %)|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)
1966 1966  |06 (write single register: write a binary value to a holding register)
1967 1967  |10 (write values to multiple addresses )
1968 1968  |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
... ... @@ -1985,61 +1985,6 @@
1985 1985  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1986 1986  |0F (Write multiple bits)
1987 1987  
1988 -== **MODBUS TCP Slave (All function)** ==
1989 -
1990 -Supported series: MODBUS TCP controller
1991 -
1992 -V-B0X works as MODBUS TCP MASTER connecting with TCP SLAVE
1993 -
1994 -**1)V-BOX Setting**
1995 -
1996 -|**Items**|**Settings**|**Note**
1997 -|Protocol|MODBUS TCP Slave (All function)|
1998 -|Connection|Ethernet|
1999 -|Port No.|502|
2000 -|PLC station No.|1
2001 -
2002 -**2)Address List**
2003 -
2004 -|=**Type**|=**Data Type**|=**Function code & Description**
2005 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
2006 -|06 (write single register: write a binary value to a holding register)
2007 -|10 (write values to multiple addresses )
2008 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
2009 -|06 (write single register: write a binary value to a holding register)
2010 -|10 (write values to multiple addresses )
2011 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
2012 -|06 (write single register: write a binary value to a holding register)
2013 -|10 (write values to multiple addresses )
2014 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
2015 -|10 (write values to multiple addresses )
2016 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
2017 -|05 (Force a single coil to force the on/off state of a logic coil)
2018 -|0F (Write multiple bits, ie write continuously)
2019 -|(% rowspan="3" %)1|02 (Read the input state)
2020 -|05 (Force a single coil to force the on/off state of a logic coil)
2021 -|0F (Write multiple bits)
2022 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
2023 -|05 (Force a single coil to force the on/off state of a logic coil)
2024 -|0F (Write multiple bits)
2025 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
2026 -|0F (Write multiple bits)
2027 -
2028 -**3)Communication Settings**
2029 -
2030 -Configure V-BOX Ethernet IP in Networking Settings
2031 -
2032 -[[image:image-20220902111833-3.png]]
2033 -
2034 -
2035 -Configure PLC Ethernet IP in Communication;
2036 -
2037 -[[image:image-20220902111121-1.png]]
2038 -
2039 -**4)Cable Wiring**
2040 -
2041 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
2042 -
2043 2043  == **communicate with VB inverter** ==
2044 2044  
2045 2045  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
0Il1q9GZgk.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -24.6 KB
Content
AB.gif
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -7.3 KB
Content
ABRS232.gif
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -7.3 KB
Content
DVPEthernetAutoSearch.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -43.6 KB
Content
DVPEthernetPLCtoPC.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -8.9 KB
Content
DVPEthernetSetup.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -19.9 KB
Content
DVPEthernetTransfer.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -59.9 KB
Content
DVPEthernetVNETPortocol.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -21.4 KB
Content
DVPEthernetWPLSoft.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -97.5 KB
Content
DVPEthernetWPLSoft2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -45.2 KB
Content
Delta DVP PROTOCOLSerial232.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -10.7 KB
Content
LldwDGntf4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -24.3 KB
Content
WgvjfWbQif.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -36.3 KB
Content
image-20220831161356-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -27.0 KB
Content
image-20220831163041-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -58.6 KB
Content
image-20220831163406-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -28.4 KB
Content
image-20220831163422-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -53.9 KB
Content
image-20220831163441-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -13.7 KB
Content
image-20220831163548-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -37.1 KB
Content
image-20220831163553-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -37.1 KB
Content
image-20220831163923-7.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -57.3 KB
Content
image-20220831164626-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -56.1 KB
Content
image-20220831164646-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -28.4 KB
Content
image-20220831164700-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -66.6 KB
Content
image-20220831164731-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -12.3 KB
Content
image-20220831165008-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -13.3 KB
Content
image-20220831165017-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -36.2 KB
Content
image-20220831165031-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -28.3 KB
Content
image-20220831165238-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -57.4 KB
Content
image-20220831170147-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -57.1 KB
Content
image-20220831170215-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -14.3 KB
Content
image-20220831170254-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -43.5 KB
Content
image-20220831170306-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -28.5 KB
Content
image-20220831171127-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -60.1 KB
Content
image-20220902104329-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -58.7 KB
Content
image-20220902111121-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -60.9 KB
Content
image-20220902111754-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -57.6 KB
Content
image-20220902111833-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -56.1 KB
Content
image-20221116105850-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -18.9 KB
Content
image-20221116105947-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -18.7 KB
Content
image-20221116110802-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -16.4 KB
Content
image-20221116110832-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -42.2 KB
Content
image-20221116110907-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -17.8 KB
Content
image-20221116110917-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -23.2 KB
Content
image-20221116111427-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -63.4 KB
Content
image-20221116111451-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -225.5 KB
Content
image-20221116111509-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -34.1 KB
Content
image-20221116111651-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -74.3 KB
Content
image-20221116111727-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -106.2 KB
Content
image-20221116114106-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -99.5 KB
Content
image-20221119101759-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -62.1 KB
Content
image-20221119101946-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -68.7 KB
Content
image-20221119171318-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -90.3 KB
Content
image-20221119171343-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -90.3 KB
Content
image-20221119171436-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -43.4 KB
Content
image-20221119171611-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -23.1 KB
Content
image-20221119171832-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -69.6 KB
Content