Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 217.1
edited by Hunter
on 2023/03/18 15:47
Change comment: There is no comment for this version
To version 207.1
edited by Bob
on 2023/02/02 11:57
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Bob
Content
... ... @@ -176,7 +176,7 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 -= Create communication with Allen-Bradley(**Rockwell**)** PLC** =
179 += Create communication with **Rockwell PLC** =
180 180  
181 181  == **DF1 Advanced Protocol** ==
182 182  
... ... @@ -274,12 +274,8 @@
274 274  (% style="text-align:center" %)
275 275  [[image:ABRS232.gif]]
276 276  
277 -(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %)
278 -(% id="cke_bm_5621S" style="display:none" %)** **
277 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
279 279  
280 -== **MicroLogix Protocol** ==
281 -
282 -(% class="wikigeneratedid" %)
283 283  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
284 284  
285 285  **1)V-BOX setting**
... ... @@ -519,17 +519,12 @@
519 519  (((
520 520  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
521 521  
522 -== **Allen-Bradley Ethernet DF1** ==
523 523  
519 += **Allen-Bradley Ethernet DF1** =
520 +
524 524  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
525 525  
526 -= Create communication with **Crouzet PLC** =
527 527  
528 -== **CROUZET M3 (FBD)** ==
529 -
530 -**1)V-BOX setting**
531 -
532 -
533 533  = Create communication with **Siemens PLC** =
534 534  
535 535  == **S7-200 Smart Ethernet Protocol** ==
... ... @@ -786,24 +786,13 @@
786 786  
787 787  {{code language="LUA"}}
788 788  function init.main()
789 -addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
790 -addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
780 +    addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
781 +
782 +    addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
783 +
791 791  end
792 792  {{/code}}
793 793  
794 -Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code.
795 -
796 -**✎Note:**
797 -
798 -* **Communication port configuration: **
799 -** Continuous length needs to be set to 0.
800 -** Integration interval needs to be set to 1. (no change may result in data errors)
801 -** Set Port and Device Station NO.
802 -** Other set as defaulted.
803 -* **Notes on the use of registers:**
804 -** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
805 -** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
806 -
807 807  = Create communication with **Mitsubishi PLC** =
808 808  
809 809  == **FX1S,1N,2N Serial Protocol** ==