Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 217.1
edited by Hunter
on 2023/03/18 15:47
Change comment: There is no comment for this version
To version 257.1
edited by Theodore Xu
on 2023/08/23 19:31
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.AiXia
Content
... ... @@ -1,6 +1,6 @@
1 -= Create communication with WECON PLC =
1 += WECON =
2 2  
3 -== **LX3V Serial Protocol** ==
3 +== **LX3V Serial ** ==
4 4  
5 5  Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
... ... @@ -48,7 +48,7 @@
48 48  
49 49   [[image:image-20220824120524-3.png]]
50 50  
51 -== **LX5V Serial Protocol** ==
51 +== **LX5V Serial ** ==
52 52  
53 53  This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
54 54  
... ... @@ -118,7 +118,7 @@
118 118  
119 119  The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC.
120 120  
121 -== **LX5V-N Ethernet protocol** ==
121 +== **LX5V-N Ethernet ** ==
122 122  
123 123  This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
124 124  
... ... @@ -176,9 +176,9 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 -= Create communication with Allen-Bradley(**Rockwell**)** PLC** =
179 += Allen-Bradley(**Rockwell**) =
180 180  
181 -== **DF1 Advanced Protocol** ==
181 +== **DF1 Advanced  Serial** ==
182 182  
183 183  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5
184 184  
... ... @@ -277,7 +277,7 @@
277 277  (% class="wikigeneratedid" id="HMicroLogixA0Protocol" %)
278 278  (% id="cke_bm_5621S" style="display:none" %)** **
279 279  
280 -== **MicroLogix Protocol** ==
280 +== **MicroLogix Serial** ==
281 281  
282 282  (% class="wikigeneratedid" %)
283 283  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
... ... @@ -317,7 +317,7 @@
317 317  
318 318  [[image:image-20220824110724-1.png]]
319 319  
320 -== **Micro850_FreeTag Protocol** ==
320 +== **Micro850_FreeTag Ethernet** ==
321 321  
322 322  (((
323 323  (((
... ... @@ -519,8 +519,94 @@
519 519  (((
520 520  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
521 521  
522 -== **Allen-Bradley Ethernet DF1** ==
523 523  
523 +== **Micro850_FreeTag Ethernet(new)** ==
524 +
525 +This example introduces the establishment of Ethernet communication between Wecon V-box and 2080-LC50-48QWB,Micro850. It is introduced through three parts: PLC software configuration, V-box software configuration.
526 +
527 +(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
528 +(((
529 +**Software configuration of PLC**
530 +)))
531 +
532 +(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %)
533 +(((
534 +**1)PLC programming software:Connected Components Workbench™**
535 +
536 +(% style="text-align:center" %)
537 +[[image:software.png]]
538 +
539 +**2)New PLC project**
540 +
541 +Click New Project and select the PLC model.
542 +
543 +(% style="text-align:center" %)
544 +[[image:project create.png]]
545 +
546 +**3)Set Ethernet parameters**
547 +
548 +Follow the steps below to configure Ethernet parameters
549 +
550 +PLC IP address:192.168.39.56
551 +
552 +default gateway:192.168.39.1
553 +
554 +subnet mask:255.255.255.0
555 +
556 +(% style="text-align:center" %)
557 +[[image:Ethernet.png]]
558 +
559 +**4)connect PLC**
560 +
561 +**When downloading the setting, need to change the status of the PLC to PRG**
562 +
563 +(% style="text-align:center" %)
564 +[[image:conne ab plc.png]]
565 +
566 +**V-box software configuration**
567 +
568 +**1)V-box programming software**
569 +
570 +(% style="text-align:center" %)
571 +[[image:v-net client vers.png]]
572 +
573 +**2)Set communication port parameters**
574 +
575 +In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
576 +
577 +(% style="text-align:center" %)
578 +[[image:V-NET_Client_t2Rg2wpSoY.png]]
579 +
580 +The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
581 +
582 +(% style="text-align:center" %)
583 +[[image:V-NET_Client_communication.png]]
584 +
585 +Export variables from PLC, select CSV file, comma delimited.(% id="cke_bm_1950S" style="display:none" %)
586 +
587 +(% style="text-align:center" %)
588 +[[image:export1.png]]
589 +
590 +(% style="text-align:center" %)
591 +[[image:CCW.Shell_E5Cwj4tUL3.png]]
592 +
593 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png"]]icon add label.
594 +
595 +(% style="text-align:center" %)
596 +[[image:V-NET_Client_TNBuqy7T5r.png]]
597 +
598 +**3)Engineering production**
599 +
600 +According to your own needs, use the V-NET client software to edit the required data monitoring points.
601 +
602 +(% style="text-align:center" %)
603 +[[image:V-NET_Client_KOR0AHEA4M.png]]
604 +
605 +
606 +)))
607 +
608 +== **Ethernet DF1 Protocol** ==
609 +
524 524  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
525 525  
526 526  = Create communication with **Crouzet PLC** =
... ... @@ -527,18 +527,200 @@
527 527  
528 528  == **CROUZET M3 (FBD)** ==
529 529  
616 +Support Series: Crouzet Millenium 3 CD12/CB12
617 +
530 530  **1)V-BOX setting**
531 531  
620 +|=Item|=Recommended |=Note
621 +|=Protocol|CROUZET M3 (FBD)|
622 +|=Connection|RS232|
623 +|=Baud rate|115200|
624 +|=Stop bits|1|
625 +|=Data bits|7|
626 +|=Parity|EVEN|
532 532  
533 -= Create communication with **Siemens PLC** =
628 +**2)Address List**
534 534  
535 -== **S7-200 Smart Ethernet Protocol** ==
630 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note
631 +|(% rowspan="4" %)Bit|I|I DD|1~~99|Input
632 +|SLIBit|SLIBit DD.dd|1.0~~24.15|Serial Link Input
633 +|SLOBit|SLOBit DD.dd|25.0~~48.15|Serial Link Output(Read only)
634 +|State|State D|1~~1|PLC state(Read only)
635 +|(% rowspan="5" %)Word|AI|AI DD|1~~99|Analog Input
636 +|SLIn|SLIn DD|1~~24|Serial Link Input
637 +|SLOut|SLOut DD|25~~48|Serial Link Output(Read only)
638 +|Time|Time D|1~~6|(((
639 +Time1: Second
536 536  
537 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
641 +Time2: Minute
538 538  
643 +Time3: Hour
539 539  
540 -== **S7-300 Ethernet Protocol** ==
645 +Time4: Day
541 541  
647 +Time5: Month
648 +
649 +Time6: Year
650 +)))
651 +|Order|Order D|1~~1|(((
652 +Running command(Write only)
653 +
654 +~=2: Run mode; =1: Stop mode;
655 +)))
656 +
657 +**3)Cable Wiring**
658 +
659 +(% style="text-align:center" %)
660 +[[image:CrouzetRS232 VBox.png]]
661 +
662 +{{info}}
663 +**✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details.
664 +{{/info}}
665 +
666 += EMERSON =
667 +
668 += **RTU Slave ** =
669 +
670 +Supported series: EC10 series
671 +
672 +**1)V-BOX setting**
673 +
674 +|**Items**|**Settings**|**Note**
675 +|Protocol|Emerson 984 RTU Slave MODBUS|
676 +|Connection|RS485|
677 +|Baud rate|19200|
678 +|Data bit|8|
679 +|Parity|EVEN|
680 +|Stop bit|1|
681 +|Device station No.|1|Need to be same as the PLC setting
682 +
683 +(% class="wikigeneratedid" %)
684 +**2)PLC Setting**
685 +
686 +(% class="wikigeneratedid" %)
687 +Remember to use the Control Star to enable the Modbus RTU communication for port 1 in system block before dowload into PLC.
688 +
689 +(% style="text-align:center" %)
690 +[[image:ControlStarSystemBlock.png]]
691 +
692 +(% style="text-align:center" %)
693 +[[image:ControlStarCommunicate.png]]
694 +
695 +(% style="text-align:center" %)
696 +[[image:ControlStarModbus.png]]
697 +
698 +(% class="wikigeneratedid" %)
699 +**3)Address List**
700 +
701 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
702 +|(% colspan="1" rowspan="12" %)Bit|Y|YOOO|0~~377|
703 +|X|XOOO|0~~377|
704 +|M0|M0DDDD|0~~2047|
705 +|M1|M1DDDDD|2048~~10239|
706 +|SM0|SM0DDD|0~~255|
707 +|SM1|SM1DDD|256~~511|
708 +|S0|S0DDDD|0~~1023|
709 +|S1|S1DDDD|1024~~4095|
710 +|T0|T0DDD|0~~255|
711 +|T1|T1DDD|256~~511|
712 +|C0|C0DDD|0~~255|
713 +|C1|C1DDD|256~~306|
714 +|(% colspan="1" rowspan="7" %)Word|D|DDDDD|0~~7999|
715 +|Z|ZDD|0~~15|
716 +|TW0|TW0DDD|0~~255|
717 +|TW1|TW1DDD|256~~511|
718 +|SD0|SD0DDD|0~~255|
719 +|SD1|SD1DDD|256~~511|
720 +|CW|CWDDD|0~~306|
721 +|(% colspan="1" rowspan="2" %)Double Word|CW0|CW0DDD|200~~255|
722 +|CW1|CW1DDDDD|256~~99999|
723 +
724 +**4) Cable Wiring**
725 +
726 +(% style="text-align:center" %)
727 +[[image:Emerson.png]]
728 +
729 += HollySys PLC =
730 +
731 +== **LK Modbus RTU ** ==
732 +
733 +Supported Series: HollySys LK series PLC
734 +
735 +**1)V-BOX setting**
736 +
737 +|**Items**|**Settings**|**Note**
738 +|Protocol|HollySys LK Modbus RTU|
739 +|Connection|RS485|
740 +|Baud rate|38400|
741 +|Data bit|8|
742 +|Parity|None|
743 +|Stop bit|1|
744 +|Device station No.|1|
745 +
746 +**2)Address List**
747 +
748 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
749 +|Bit|QX|QXDDDDD.dd|0~~65535.15|
750 +|Bit|IX|IXDDDDD.dd|0~~65535.15|
751 +|Bit|MX|MXDDDDD.dd|0~~65535.15|
752 +|Word|QW|QWDDDDD|0~~99999|
753 +|Word|IW|IWDDDDD|0~~99999|
754 +|Word|MW|MWDDDDD|0~~99999|
755 +|Word|MD|MDDDDDD|0~~99999|
756 +
757 +**3)Cable Wiring**
758 +
759 +(% style="text-align:center" %)
760 +[[image:Hollysys485-2.png]]
761 +
762 +== **LM Modbus RTU** ==
763 +
764 +(% class="wikigeneratedid" %)
765 +Supported Series: HollySys LM3109/LM3107 PLC
766 +
767 +(% class="wikigeneratedid" %)
768 +**1)V-BOX setting**
769 +
770 +|(% style="width:208px" %)**Items**|(% style="width:310px" %)**Settings**|(% style="width:365px" %)**Optional**|(% style="width:152px" %)**Note**
771 +|(% style="width:208px" %)Protocol|(% style="width:310px" %)HollySys LM Modbus RTU|(% style="width:365px" %)HollySys LM Modbus RTU|(% style="width:152px" %)
772 +|(% style="width:208px" %)Connection|(% style="width:310px" %)RS232|(% style="width:365px" %)RS485|(% style="width:152px" %)
773 +|(% style="width:208px" %)Baud rate|(% style="width:310px" %)38400|(% style="width:365px" %)38400|(% style="width:152px" %)
774 +|(% style="width:208px" %)Data bit|(% style="width:310px" %)8|(% style="width:365px" %)8|(% style="width:152px" %)
775 +|(% style="width:208px" %)Parity|(% style="width:310px" %)None|(% style="width:365px" %)None|(% style="width:152px" %)
776 +|(% style="width:208px" %)Stop bit|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
777 +|(% style="width:208px" %)Device station No.|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
778 +
779 +**2)Address List**
780 +
781 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
782 +|Bit|QX|QXDDDDD.o|0~~99999.7|
783 +|Bit|IX|IXDDDDD.o|0~~99999.7|
784 +|Bit|MX|MXDDDDD.o|0~~99999.7|
785 +|Word|QW|QWDDDDD|0~~99999|
786 +|Word|IW|IWDDDDD|0~~99999|
787 +|Word|MW|MWDDDDD|0~~99999|
788 +|Word|MD|MDDDDDD|0~~99999|
789 +
790 +**Cable Wiring**
791 +
792 +RS232
793 +
794 +(% style="text-align:center" %)
795 +[[image:HollySysRS232.png]]
796 +
797 +RS485
798 +
799 +(% style="text-align:center" %)
800 +[[image:Hollysys LM Modbus RTU.gif]]
801 +
802 += **Siemens ** =
803 +
804 +== **S7-200 Smart Ethernet ** ==
805 +
806 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
807 +
808 +== **S7-300 Ethernet ** ==
809 +
542 542  Supported Series: Siemens S7-300 series PLC
543 543  
544 544  **1)V-BOX setting**
... ... @@ -595,11 +595,11 @@
595 595  )))
596 596  )))
597 597  
598 -== **S7-1200 Ethernet Protocol** ==
866 +== **S7-1200 Ethernet ** ==
599 599  
600 600  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
601 601  
602 -== **S7-XXX Ethernet Protocol** ==
870 +== **S7-XXX Ethernet l** ==
603 603  
604 604  Supported Series: Siemens S7-400, S7-1200 and S7-1500
605 605  
... ... @@ -713,7 +713,7 @@
713 713  
714 714  [[image:image-20220824162342-2.png]]
715 715  
716 -== **LOGO Ethernet Protocol** ==
984 +== **LOGO Ethernet ** ==
717 717  
718 718  Supported Series: Siemens Logo 0BA0, 0BA1 series
719 719  
... ... @@ -804,9 +804,9 @@
804 804  ** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
805 805  ** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
806 806  
807 -= Create communication with **Mitsubishi PLC** =
1075 += **Mitsubishi ** =
808 808  
809 -== **FX1S,1N,2N Serial Protocol** ==
1077 +== **FX1S,1N,2N Serial ** ==
810 810  
811 811  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
812 812  
... ... @@ -853,7 +853,7 @@
853 853  [[image:image-20220825100845-4.png]]
854 854  
855 855  
856 -== **FX3U,3G,3GA Serial Protocol** ==
1124 +== **FX3U,3G,3GA Serial ** ==
857 857  
858 858  Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
859 859  
... ... @@ -900,7 +900,7 @@
900 900  [[image:image-20220825100845-4.png]]
901 901  
902 902  
903 -== **FX3U Ethernet Protocol** ==
1171 +== **FX3U Ethernet ** ==
904 904  
905 905  Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
906 906  
... ... @@ -995,7 +995,7 @@
995 995  
996 996  [[image:image-20221119101946-2.png||height="395" width="695"]]
997 997  
998 -== **FX5U Serial Protocol** ==
1266 +== **FX5U Serial ** ==
999 999  
1000 1000  Mitsubishi FX5U series PLC
1001 1001  
... ... @@ -1077,7 +1077,7 @@
1077 1077  
1078 1078  [[image:image-20220825105533-3.png]]
1079 1079  
1080 -== **FX5U Ethernet Protocol** ==
1348 +== **FX5U Ethernet ** ==
1081 1081  
1082 1082  Mitsubishi FX5U series PLC
1083 1083  
... ... @@ -1153,7 +1153,7 @@
1153 1153  
1154 1154  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1155 1155  
1156 -== **L02 Serial Protocol** ==
1424 +== **L02 Serial ** ==
1157 1157  
1158 1158  Mitsubishi L02 series CPU built-in serial port.
1159 1159  
... ... @@ -1213,7 +1213,7 @@
1213 1213  
1214 1214  [[image:image-20220825160820-4.png]]
1215 1215  
1216 -== **L02 Ethernet Protocol** ==
1484 +== **L02 Ethernet ** ==
1217 1217  
1218 1218  Mitsubishi L series CPU built-in Ethernet port.
1219 1219  
... ... @@ -1286,13 +1286,13 @@
1286 1286  
1287 1287  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1288 1288  
1289 -== **Q12H Serial Protocol** ==
1557 +== **Q12H Serial ** ==
1290 1290  
1291 1291  This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
1292 1292  
1293 1293  [[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]
1294 1294  
1295 -== **QJ71E71 Ethernet Protocol** ==
1563 +== **QJ71E71 Ethernet ** ==
1296 1296  
1297 1297  Mitsubishi QJ71E71 Ethernet communication module;
1298 1298  
... ... @@ -1367,9 +1367,9 @@
1367 1367  
1368 1368  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
1369 1369  
1370 -= Create communication with **Delta PLC** =
1638 += **Delta** =
1371 1371  
1372 -== **DVP Ethernet Protocol** ==
1640 +== **DVP Ethernet** ==
1373 1373  
1374 1374  Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module
1375 1375  
... ... @@ -1434,7 +1434,7 @@
1434 1434  (% style="text-align:center" %)
1435 1435  [[image:DVPEthernetVNETPortocol.png]]
1436 1436  
1437 -== **DVP serial protocol** ==
1705 +== **DVP serial** ==
1438 1438  
1439 1439  Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX
1440 1440  
... ... @@ -1470,7 +1470,7 @@
1470 1470  (% style="text-align:center" %)
1471 1471  [[image:Delta DVP PROTOCOLSerial232.png]]
1472 1472  
1473 -== **AS Ethernet Protocol** ==
1741 +== **AS Ethernet** ==
1474 1474  
1475 1475  **1)V-BOX Settings**
1476 1476  
... ... @@ -1515,19 +1515,18 @@
1515 1515  
1516 1516  [[image:image-20220831155157-3.png]]
1517 1517  
1518 -= Create communication with **Omron PLC** =
1786 += **Omron** =
1519 1519  
1520 -== **CP1 Series Protocol ** ==
1788 +== **CP1 Series** ==
1521 1521  
1522 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1790 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1523 1523  
1524 -== **CP2M Series Protocol** ==
1792 +== **CP2M Series** ==
1525 1525  
1526 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1794 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1527 1527  
1796 +== **EC55 Series ** ==
1528 1528  
1529 -== **EC55 Series Protocol** ==
1530 -
1531 1531  Supported device: EC55 temperature instrument
1532 1532  
1533 1533  **1)V-BOX Settings**
... ... @@ -1587,9 +1587,9 @@
1587 1587  * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1588 1588  * [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1589 1589  
1590 -= Create communication with Xinje** PLC** =
1857 += Xinje =
1591 1591  
1592 -== **XC serial protocol** ==
1859 +== **XC serial** ==
1593 1593  
1594 1594  **1)V-BOX Settings**
1595 1595  
... ... @@ -1631,7 +1631,7 @@
1631 1631  
1632 1632  [[image:image-20220831163441-4.png]]
1633 1633  
1634 -== **XD serial protocol** ==
1901 +== **XD serial** ==
1635 1635  
1636 1636  **1)V-BOX Settings**
1637 1637  
... ... @@ -1705,7 +1705,7 @@
1705 1705  
1706 1706  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1707 1707  
1708 -= Create communication with **Schneider PLC** =
1975 += **Schneider** =
1709 1709  
1710 1710  == **Schneider MODBUS RTU** ==
1711 1711  
... ... @@ -1739,7 +1739,7 @@
1739 1739  
1740 1740  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
1741 1741  
1742 -= Create communication with Inovance** PLC** =
2009 += Inovance =
1743 1743  
1744 1744  == **H3U serial protocol** ==
1745 1745  
... ... @@ -1791,9 +1791,9 @@
1791 1791  
1792 1792  [[image:image-20220831164731-4.png]]
1793 1793  
1794 -= Create communication with Panasonic** PLC** =
2061 += Panasonic =
1795 1795  
1796 -== **FP serial protocol** ==
2063 +== **FP serial** ==
1797 1797  
1798 1798  **1)V-BOX Settings**
1799 1799  
... ... @@ -1841,9 +1841,9 @@
1841 1841  
1842 1842  [[image:image-20220831165008-1.png]]
1843 1843  
1844 -= Create communication with LS** PLC** =
2111 += LS =
1845 1845  
1846 -== **XBC serial protocol** ==
2113 +== **XBC serial** ==
1847 1847  
1848 1848  **1)V-BOX Settings**
1849 1849  
... ... @@ -1895,7 +1895,7 @@
1895 1895  
1896 1896  [[image:image-20220831170215-2.png]]
1897 1897  
1898 -== **XGK FEnet Ethernet protocol** ==
2165 +== **XGK FEnet Ethernet** ==
1899 1899  
1900 1900  Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1901 1901  
... ... @@ -1938,8 +1938,76 @@
1938 1938  
1939 1939  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1940 1940  
1941 -= Create communication with **Modbus ** =
2208 += INVT =
1942 1942  
2210 +**1)V-BOX setting**
2211 +
2212 +|**Item**|**Settings**|**Note**
2213 +|Protocol|INVT_IVC2L|
2214 +|Connection|RS232|
2215 +|Baud rate|19200|
2216 +|Data bit|8|
2217 +|Parity|EVEN|
2218 +|Stop bit|1|
2219 +|PLC station No.|1
2220 +
2221 +**2)Address List**
2222 +
2223 +
2224 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
2225 +|(% colspan="1" rowspan="7" %)Bit|X|XOOO|0~~377|
2226 +|Y|YOOO|0~~377|
2227 +|M|MDDDD|0~~1999|
2228 +|SM|SMDDD|0~~255|
2229 +|S|SDDD|0~~991|
2230 +|T|TDDD|0~~255|
2231 +|C|CDDD|0~~255|
2232 +|(% rowspan="5" %)Word|D|DDDDD|0~~7999|
2233 +|SD|SDDDD|0~~255|
2234 +|Z|ZDD|0~~15|
2235 +|T|TDDD|0~~255|
2236 +|C|CDDD|0~~199|
2237 +|Double word|C|CDDD|200~~255|
2238 +
2239 +**3)Communication Settings**
2240 +
2241 +(% style="text-align:center" %)
2242 +[[image:盒子创建英威腾.png]]
2243 +
2244 +**4)PLC software**
2245 +
2246 +(% style="text-align:center" %)
2247 +[[image:英威腾软件.png]]
2248 +
2249 +**5)PLC setting **
2250 +
2251 +Open the INVI plc software, create a new project or open a project that has already been created
2252 +
2253 +(% style="text-align:center" %)
2254 +[[image:英威腾创建1.png]]
2255 +
2256 +Configure serial port parameters.
2257 +
2258 +(% style="text-align:center" %)
2259 +[[image:英威腾创建2.png]]
2260 +
2261 +PC connect PLC
2262 +
2263 +(% style="text-align:center" %)
2264 +[[image:英威腾创建3.png]]
2265 +
2266 +Download
2267 +
2268 +(% style="text-align:center" %)
2269 +[[image:英威腾下载.png]]
2270 +
2271 +**6)Cable Wiring**
2272 +
2273 +(% style="text-align:center" %)
2274 +[[image:wire.png]]
2275 +
2276 += **Modbus ** =
2277 +
1943 1943  == **MODBUS RTU Slave (All function)** ==
1944 1944  
1945 1945  Select the protocol "Modbus RTU Slave (All Fuction)",
... ... @@ -1949,6 +1949,86 @@
1949 1949  (% style="text-align:center" %)
1950 1950  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
1951 1951  
2287 +== **Modbus Meter** ==
2288 +
2289 +The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication.
2290 +
2291 +~1. Wiring the RS485 cable first. Because the pin 58 is A, the pin 59 is B for meter. Here we use the COM1 to connect. So the diagram like follows:
2292 +
2293 +(% style="text-align:center" %)
2294 +[[image:LinfeeTerminalDiagram.png]]
2295 +
2296 +2. Check the specific Modbus parameter in the communication menu from LED display.
2297 +
2298 +So from the following pictures, we can know the Meter Address is 85, Baud rate is 9600, CRC None.
2299 +
2300 +{{info}}
2301 +**✎Note: **Meter address usually corresponding to the Modbus Slave Station No. on the Modbus communication.
2302 +{{/info}}
2303 +
2304 +(% style="text-align:center" %)
2305 +[[image:MeterModbusAllView.png]]
2306 +
2307 +(% class="wikigeneratedid" %)
2308 +3. Set up the communication in the Configuration tab.
2309 +
2310 +(% class="wikigeneratedid" %)
2311 +Select the protocol as **ModBus RTU Slave (All Function)**. And set the communication parameters like below.
2312 +
2313 +(% style="text-align:center" %)
2314 +[[image:VNETCommunicationtabmeter.png]]
2315 +
2316 +(% class="wikigeneratedid" %)
2317 +4. Create new real-time monitoring tag accroding to Modbus manual
2318 +
2319 +(% class="wikigeneratedid" %)
2320 +Enter the address we want to read from the meter. The following table is intercept part of the manual for Linfee Modbus manual.
2321 +
2322 +(% class="wikigeneratedid" %)
2323 +**0x03/0x04 command data register address**:
2324 +
2325 +(% style="width:1142.22px" %)
2326 +|(% style="display:none" %) |=(% colspan="2" rowspan="1" style="width: 165px;" %)Address(% style="display:none" %) |=Description|=Data Format|=(% style="width: 254px;" %)Data Length(Word)|=(% style="width: 282px;" %)Remark
2327 +|(%%)(% style="display:none" %) (%%) HEX|(% style="width:107px" %)DEC|(%%)(% style="display:none" %) (%%) |(% style="width:100px" %) |(%%)(% style="display:none" %) (%%) |(% style="width:318px" %)
2328 +|(% style="width:107px" %)0x00|(% style="width:100px" %)0|Reserved| | |(% style="width:318px" %)
2329 +|(% style="width:107px" %)0x02|(% style="width:100px" %)2|Reserved| | |(% style="width:318px" %)
2330 +|(% style="width:107px" %)0x04|(% style="width:100px" %)4|Reserved| | |(% style="width:318px" %)
2331 +|(% style="width:107px" %)0x06|(% style="width:100px" %)6|Ua|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2332 +|(% style="width:107px" %)0x08|(% style="width:100px" %)8|Ub|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2333 +|(% style="width:107px" %)0x0A|(% style="width:100px" %)10|Uc|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2334 +|(% style="width:107px" %)0x0C|(% style="width:100px" %)12|Uab|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2335 +|(% style="width:107px" %)0x0E|(% style="width:100px" %)14|Ubc|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2336 +|(% style="width:107px" %)0x10|(% style="width:100px" %)16|Uca|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2337 +|(% style="width:107px" %)0x12|(% style="width:100px" %)18|Ia|float|2|(% style="width:318px" %)Phase Current data, Unit A
2338 +|(% style="width:107px" %)0x14|(% style="width:100px" %)20|Ib|float|2|(% style="width:318px" %)Phase Current data, Unit A
2339 +|(% style="width:107px" %)0x16|(% style="width:100px" %)22|Ic|float|2|(% style="width:318px" %)Phase Current data, Unit A
2340 +
2341 +{{info}}
2342 +**✎Note: **We usually use the Data Type 4 for read the Modbus registers(Function Code 03)
2343 +{{/info}}
2344 +
2345 +For example, here we want to read the Phase Voltage Ua (Modbus offset 0006), the Modbus register main No. requires input decimal number, and check whether the actual address has one address offset, so the tag configured like the following screenshot:
2346 +
2347 +(% style="text-align:center" %)
2348 +[[image:VNETModbusTagSettings.png]]
2349 +
2350 +(% style="text-align:center" %)
2351 +[[image:VNETModbusTagByteSettings.png]]
2352 +
2353 +{{info}}
2354 +**✎Note: **If the read value is incorrect, please check whether need to change the Byte order.
2355 +{{/info}}
2356 +
2357 +Set the Modbus Slave Station No.
2358 +
2359 +(% style="text-align:center" %)
2360 +[[image:ModbusStationSettings.png]]
2361 +
2362 +If the communication is setup successfully, the tag will show green light.
2363 +
2364 +(% style="text-align:center" %)
2365 +[[image:Monitoringtaggreenlight.png]]
2366 +
1952 1952  == **MODBUS RTU Master** ==
1953 1953  
1954 1954  Select the protocol "Modbus RTU Master",
1679563870401-671.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +39.3 KB
Content
1682233464031-639.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +15.9 KB
Content
CCW.Shell_E5Cwj4tUL3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +27.1 KB
Content
ControlStarCommunicate.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +26.0 KB
Content
ControlStarModbus.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content
ControlStarSystemBlock.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +46.3 KB
Content
CrouzetRS232 VBox.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +14.9 KB
Content
Emerson.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
Ethernet.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +45.5 KB
Content
HollySysRS232.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +10.4 KB
Content
Hollysys LM Modbus RTU.gif
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.1 KB
Content
Hollysys485-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.5 KB
Content
Hollysys485box.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.4 KB
Content
LinfeeTerminalDiagram.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content
MeterModbusAddr.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +562.5 KB
Content
MeterModbusAllView.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +1.6 MB
Content
MeterModbusBaud.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +444.0 KB
Content
MeterModbusPara.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +532.0 KB
Content
ModbusStationSettings.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +35.8 KB
Content
Monitoringtaggreenlight.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.5 KB
Content
V-NET_Client setting.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +41.9 KB
Content
V-NET_Client_ADD.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +51.4 KB
Content
V-NET_Client_KOR0AHEA4M.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +14.2 KB
Content
V-NET_Client_TIiAymnjkx.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +12.8 KB
Content
V-NET_Client_TNBuqy7T5r.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +26.7 KB
Content
V-NET_Client_communication.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +25.5 KB
Content
V-NET_Client_iKKKhcgxm1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +35.9 KB
Content
V-NET_Client_t2Rg2wpSoY.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +53.7 KB
Content
VNETCommunicationtabmeter.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +31.0 KB
Content
VNETModbusTagByteSettings.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +31.2 KB
Content
VNETModbusTagSettings.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +35.7 KB
Content
conne ab plc.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +43.1 KB
Content
export.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +115.2 KB
Content
export1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +115.2 KB
Content
plc 软件.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +106.8 KB
Content
project create.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +65.5 KB
Content
software.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +25.8 KB
Content
v-net client vers.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +13.1 KB
Content
wire.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +137.2 KB
Content
企业微信截图_16889606174191.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +20.7 KB
Content
盒子创建英威腾.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +86.5 KB
Content
英威腾下载.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +49.0 KB
Content
英威腾创建1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +36.7 KB
Content
英威腾创建2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +115.7 KB
Content
英威腾创建3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +76.6 KB
Content
英威腾软件.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +52.6 KB
Content