Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -527,6 +527,8 @@ 527 527 528 528 == **CROUZET M3 (FBD)** == 529 529 530 +Support Series: Crouzet Millenium 3 CD12/CB12 531 + 530 530 **1)V-BOX setting** 531 531 532 532 |=Item|=Recommended |=Note ... ... @@ -571,6 +571,10 @@ 571 571 (% style="text-align:center" %) 572 572 [[image:CrouzetRS232 VBox.png]] 573 573 576 +{{info}} 577 +**✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details. 578 +{{/info}} 579 + 574 574 = Create communication with **Siemens PLC** = 575 575 576 576 == **S7-200 Smart Ethernet Protocol** == ... ... @@ -1990,6 +1990,23 @@ 1990 1990 (% style="text-align:center" %) 1991 1991 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 1992 1992 1999 +== **Communicate with Modbus Meter** == 2000 + 2001 +The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication. 2002 + 2003 +~1. Wiring the RS485 cable first. Because the pin 58 is A, the pin 59 is B for meter. Here we use the COM1 to connect. So the diagram like follows: 2004 + 2005 +(% style="text-align:center" %) 2006 +[[image:LinfeeTerminalDiagram.png]] 2007 + 2008 +2. Check the specific Modbus parameter in the communication menu from LED display. 2009 + 2010 +So from the following pictures, we can know the Meter Address is 85, Baud rate is 9600, CRC None. 2011 + 2012 + 2013 +(% style="text-align:center" %) 2014 +[[image:MeterModbusAllView.png]] 2015 + 1993 1993 == **MODBUS RTU Master** == 1994 1994 1995 1995 Select the protocol "Modbus RTU Master",
- LinfeeTerminalDiagram.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.6 KB - Content
- MeterModbusAddr.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +562.5 KB - Content
- MeterModbusAllView.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.6 MB - Content
- MeterModbusBaud.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +444.0 KB - Content
- MeterModbusPara.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +532.0 KB - Content