1 -= Create communication with WECON PLC =
1 += WECON =
2 2  
3 -== **LX3V Serial Protocol** ==
3 +== **LX3V Serial ** ==
4 4  
5 5  Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
... ... @@ -48,7 +48,7 @@
48 48  
49 49   [[image:image-20220824120524-3.png]]
50 50  
51 -== **LX5V Serial Protocol** ==
51 +== **LX5V Serial ** ==
52 52  
53 53  This example introduces the establishment of serial port communication between V-BOX and LX5V. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
54 54  
... ... @@ -118,7 +118,7 @@
118 118  
119 119  The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC.
120 120  
121 -== **LX5V-N Ethernet protocol** ==
121 +== **LX5V-N Ethernet ** ==
122 122  
123 123  This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
124 124  
... ... @@ -176,9 +176,9 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 -= Create communication with Allen-Bradley(**Rockwell**)** PLC** =
179 += Allen-Bradley(**Rockwell**) =
180 180  
181 -== **DF1 Advanced Protocol** ==
181 +== **DF1 Advanced  Serial** ==
182 182  
183 183  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5
184 184  
... ... @@ -277,7 +277,7 @@
277 277  (% class="wikigeneratedid" id="HMicroLogixA0Protocol" %)
278 278  (% id="cke_bm_5621S" style="display:none" %)** **
279 279  
280 -== **MicroLogix Protocol** ==
280 +== **MicroLogix Serial** ==
281 281  
282 282  (% class="wikigeneratedid" %)
283 283  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
... ... @@ -317,7 +317,7 @@
317 317  
318 318  [[image:image-20220824110724-1.png]]
319 319  
320 -== **Micro850_FreeTag Protocol** ==
320 +== **Micro850_FreeTag Ethernet** ==
321 321  
322 322  (((
323 323  (((
... ... @@ -519,6 +519,92 @@
519 519  (((
520 520  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
521 521  
522 +
523 +== **Micro850_FreeTag Ethernet(new)** ==
524 +
525 +This example introduces the establishment of Ethernet communication between Wecon V-box and 2080-LC50-48QWB,Micro850. It is introduced through three parts: PLC software configuration, V-box software configuration.
526 +
527 +(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
528 +(((
529 +**Software configuration of PLC**
530 +)))
531 +
532 +(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %)
533 +(((
534 +**1)PLC programming software:Connected Components Workbench™**
535 +
536 +(% style="text-align:center" %)
537 +[[image:software.png]]
538 +
539 +**2)New PLC project**
540 +
541 +Click New Project and select the PLC model.
542 +
543 +(% style="text-align:center" %)
544 +[[image:project create.png]]
545 +
546 +**3)Set Ethernet parameters**
547 +
548 +Follow the steps below to configure Ethernet parameters
549 +
550 +PLC IP address:192.168.39.56
551 +
552 +default gateway:192.168.39.1
553 +
554 +subnet mask:255.255.255.0
555 +
556 +(% style="text-align:center" %)
557 +[[image:Ethernet.png]]
558 +
559 +**4)connect PLC**
560 +
561 +**When downloading the setting, need to change the status of the PLC to PRG**
562 +
563 +(% style="text-align:center" %)
564 +[[image:conne ab plc.png]]
565 +
566 +**V-box software configuration**
567 +
568 +**1)V-box programming software**
569 +
570 +(% style="text-align:center" %)
571 +[[image:v-net client vers.png]]
572 +
573 +**2)Set communication port parameters**
574 +
575 +In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
576 +
577 +(% style="text-align:center" %)
578 +[[image:V-NET_Client_t2Rg2wpSoY.png]]
579 +
580 +The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
581 +
582 +(% style="text-align:center" %)
583 +[[image:V-NET_Client_communication.png]]
584 +
585 +Export variables from PLC, select CSV file, comma delimited.(% id="cke_bm_1950S" style="display:none" %)
586 +
587 +(% style="text-align:center" %)
588 +[[image:export1.png]]
589 +
590 +(% style="text-align:center" %)
591 +[[image:CCW.Shell_E5Cwj4tUL3.png]]
592 +
593 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png"]]icon add label.
594 +
595 +(% style="text-align:center" %)
596 +[[image:V-NET_Client_TNBuqy7T5r.png]]
597 +
598 +**3)Engineering production**
599 +
600 +According to your own needs, use the V-NET client software to edit the required data monitoring points.
601 +
602 +(% style="text-align:center" %)
603 +[[image:V-NET_Client_KOR0AHEA4M.png]]
604 +
605 +
606 +)))
607 +
522 522  == **Ethernet DF1 Protocol** ==
523 523  
524 524  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
... ... @@ -527,6 +527,8 @@
527 527  
528 528  == **CROUZET M3 (FBD)** ==
529 529  
616 +Support Series: Crouzet Millenium 3 CD12/CB12
617 +
530 530  **1)V-BOX setting**
531 531  
532 532  |=Item|=Recommended |=Note
... ... @@ -575,15 +575,150 @@
575 575  **✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details.
576 576  {{/info}}
577 577  
578 -= Create communication with **Siemens PLC** =
666 += EMERSON =
579 579  
580 -== **S7-200 Smart Ethernet Protocol** ==
668 += **RTU Slave ** =
581 581  
582 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
670 +Supported series: EC10 series
583 583  
672 +**1)V-BOX setting**
584 584  
585 -== **S7-300 Ethernet Protocol** ==
674 +|**Items**|**Settings**|**Note**
675 +|Protocol|Emerson 984 RTU Slave MODBUS|
676 +|Connection|RS485|
677 +|Baud rate|19200|
678 +|Data bit|8|
679 +|Parity|EVEN|
680 +|Stop bit|1|
681 +|Device station No.|1|Need to be same as the PLC setting
586 586  
683 +(% class="wikigeneratedid" %)
684 +**2)PLC Setting**
685 +
686 +(% class="wikigeneratedid" %)
687 +Remember to use the Control Star to enable the Modbus RTU communication for port 1 in system block before dowload into PLC.
688 +
689 +(% style="text-align:center" %)
690 +[[image:ControlStarSystemBlock.png]]
691 +
692 +(% style="text-align:center" %)
693 +[[image:ControlStarCommunicate.png]]
694 +
695 +(% style="text-align:center" %)
696 +[[image:ControlStarModbus.png]]
697 +
698 +(% class="wikigeneratedid" %)
699 +**3)Address List**
700 +
701 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
702 +|(% colspan="1" rowspan="12" %)Bit|Y|YOOO|0~~377|
703 +|X|XOOO|0~~377|
704 +|M0|M0DDDD|0~~2047|
705 +|M1|M1DDDDD|2048~~10239|
706 +|SM0|SM0DDD|0~~255|
707 +|SM1|SM1DDD|256~~511|
708 +|S0|S0DDDD|0~~1023|
709 +|S1|S1DDDD|1024~~4095|
710 +|T0|T0DDD|0~~255|
711 +|T1|T1DDD|256~~511|
712 +|C0|C0DDD|0~~255|
713 +|C1|C1DDD|256~~306|
714 +|(% colspan="1" rowspan="7" %)Word|D|DDDDD|0~~7999|
715 +|Z|ZDD|0~~15|
716 +|TW0|TW0DDD|0~~255|
717 +|TW1|TW1DDD|256~~511|
718 +|SD0|SD0DDD|0~~255|
719 +|SD1|SD1DDD|256~~511|
720 +|CW|CWDDD|0~~306|
721 +|(% colspan="1" rowspan="2" %)Double Word|CW0|CW0DDD|200~~255|
722 +|CW1|CW1DDDDD|256~~99999|
723 +
724 +**4) Cable Wiring**
725 +
726 +(% style="text-align:center" %)
727 +[[image:Emerson.png]]
728 +
729 += HollySys PLC =
730 +
731 +== **LK Modbus RTU ** ==
732 +
733 +Supported Series: HollySys LK series PLC
734 +
735 +**1)V-BOX setting**
736 +
737 +|**Items**|**Settings**|**Note**
738 +|Protocol|HollySys LK Modbus RTU|
739 +|Connection|RS485|
740 +|Baud rate|38400|
741 +|Data bit|8|
742 +|Parity|None|
743 +|Stop bit|1|
744 +|Device station No.|1|
745 +
746 +**2)Address List**
747 +
748 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
749 +|Bit|QX|QXDDDDD.dd|0~~65535.15|
750 +|Bit|IX|IXDDDDD.dd|0~~65535.15|
751 +|Bit|MX|MXDDDDD.dd|0~~65535.15|
752 +|Word|QW|QWDDDDD|0~~99999|
753 +|Word|IW|IWDDDDD|0~~99999|
754 +|Word|MW|MWDDDDD|0~~99999|
755 +|Word|MD|MDDDDDD|0~~99999|
756 +
757 +**3)Cable Wiring**
758 +
759 +(% style="text-align:center" %)
760 +[[image:Hollysys485-2.png]]
761 +
762 +== **LM Modbus RTU** ==
763 +
764 +(% class="wikigeneratedid" %)
765 +Supported Series: HollySys LM3109/LM3107 PLC
766 +
767 +(% class="wikigeneratedid" %)
768 +**1)V-BOX setting**
769 +
770 +|(% style="width:208px" %)**Items**|(% style="width:310px" %)**Settings**|(% style="width:365px" %)**Optional**|(% style="width:152px" %)**Note**
771 +|(% style="width:208px" %)Protocol|(% style="width:310px" %)HollySys LM Modbus RTU|(% style="width:365px" %)HollySys LM Modbus RTU|(% style="width:152px" %)
772 +|(% style="width:208px" %)Connection|(% style="width:310px" %)RS232|(% style="width:365px" %)RS485|(% style="width:152px" %)
773 +|(% style="width:208px" %)Baud rate|(% style="width:310px" %)38400|(% style="width:365px" %)38400|(% style="width:152px" %)
774 +|(% style="width:208px" %)Data bit|(% style="width:310px" %)8|(% style="width:365px" %)8|(% style="width:152px" %)
775 +|(% style="width:208px" %)Parity|(% style="width:310px" %)None|(% style="width:365px" %)None|(% style="width:152px" %)
776 +|(% style="width:208px" %)Stop bit|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
777 +|(% style="width:208px" %)Device station No.|(% style="width:310px" %)1|(% style="width:365px" %)1|(% style="width:152px" %)
778 +
779 +**2)Address List**
780 +
781 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
782 +|Bit|QX|QXDDDDD.o|0~~99999.7|
783 +|Bit|IX|IXDDDDD.o|0~~99999.7|
784 +|Bit|MX|MXDDDDD.o|0~~99999.7|
785 +|Word|QW|QWDDDDD|0~~99999|
786 +|Word|IW|IWDDDDD|0~~99999|
787 +|Word|MW|MWDDDDD|0~~99999|
788 +|Word|MD|MDDDDDD|0~~99999|
789 +
790 +**Cable Wiring**
791 +
792 +RS232
793 +
794 +(% style="text-align:center" %)
795 +[[image:HollySysRS232.png]]
796 +
797 +RS485
798 +
799 +(% style="text-align:center" %)
800 +[[image:Hollysys LM Modbus RTU.gif]]
801 +
802 += **Siemens ** =
803 +
804 +== **S7-200 Smart Ethernet ** ==
805 +
806 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
807 +
808 +== **S7-300 Ethernet ** ==
809 +
587 587  Supported Series: Siemens S7-300 series PLC
588 588  
589 589  **1)V-BOX setting**
... ... @@ -640,11 +640,11 @@
640 640  )))
641 641  )))
642 642  
643 -== **S7-1200 Ethernet Protocol** ==
866 +== **S7-1200 Ethernet ** ==
644 644  
645 645  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
646 646  
647 -== **S7-XXX Ethernet Protocol** ==
870 +== **S7-XXX Ethernet l** ==
648 648  
649 649  Supported Series: Siemens S7-400, S7-1200 and S7-1500
650 650  
... ... @@ -758,7 +758,7 @@
758 758  
759 759  [[image:image-20220824162342-2.png]]
760 760  
761 -== **LOGO Ethernet Protocol** ==
984 +== **LOGO Ethernet ** ==
762 762  
763 763  Supported Series: Siemens Logo 0BA0, 0BA1 series
764 764  
... ... @@ -849,9 +849,9 @@
849 849  ** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
850 850  ** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
851 851  
852 -= Create communication with **Mitsubishi PLC** =
1075 += **Mitsubishi ** =
853 853  
854 -== **FX1S,1N,2N Serial Protocol** ==
1077 +== **FX1S,1N,2N Serial ** ==
855 855  
856 856  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
857 857  
... ... @@ -898,7 +898,7 @@
898 898  [[image:image-20220825100845-4.png]]
899 899  
900 900  
901 -== **FX3U,3G,3GA Serial Protocol** ==
1124 +== **FX3U,3G,3GA Serial ** ==
902 902  
903 903  Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
904 904  
... ... @@ -945,7 +945,7 @@
945 945  [[image:image-20220825100845-4.png]]
946 946  
947 947  
948 -== **FX3U Ethernet Protocol** ==
1171 +== **FX3U Ethernet ** ==
949 949  
950 950  Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
951 951  
... ... @@ -1040,7 +1040,7 @@
1040 1040  
1041 1041  [[image:image-20221119101946-2.png||height="395" width="695"]]
1042 1042  
1043 -== **FX5U Serial Protocol** ==
1266 +== **FX5U Serial ** ==
1044 1044  
1045 1045  Mitsubishi FX5U series PLC
1046 1046  
... ... @@ -1122,7 +1122,7 @@
1122 1122  
1123 1123  [[image:image-20220825105533-3.png]]
1124 1124  
1125 -== **FX5U Ethernet Protocol** ==
1348 +== **FX5U Ethernet ** ==
1126 1126  
1127 1127  Mitsubishi FX5U series PLC
1128 1128  
... ... @@ -1198,7 +1198,7 @@
1198 1198  
1199 1199  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1200 1200  
1201 -== **L02 Serial Protocol** ==
1424 +== **L02 Serial ** ==
1202 1202  
1203 1203  Mitsubishi L02 series CPU built-in serial port.
1204 1204  
... ... @@ -1258,7 +1258,7 @@
1258 1258  
1259 1259  [[image:image-20220825160820-4.png]]
1260 1260  
1261 -== **L02 Ethernet Protocol** ==
1484 +== **L02 Ethernet ** ==
1262 1262  
1263 1263  Mitsubishi L series CPU built-in Ethernet port.
1264 1264  
... ... @@ -1331,13 +1331,13 @@
1331 1331  
1332 1332  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1333 1333  
1334 -== **Q12H Serial Protocol** ==
1557 +== **Q12H Serial ** ==
1335 1335  
1336 1336  This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
1337 1337  
1338 1338  [[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]
1339 1339  
1340 -== **QJ71E71 Ethernet Protocol** ==
1563 +== **QJ71E71 Ethernet ** ==
1341 1341  
1342 1342  Mitsubishi QJ71E71 Ethernet communication module;
1343 1343  
... ... @@ -1412,9 +1412,9 @@
1412 1412  
1413 1413  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
1414 1414  
1415 -= Create communication with **Delta PLC** =
1638 += **Delta** =
1416 1416  
1417 -== **DVP Ethernet Protocol** ==
1640 +== **DVP Ethernet** ==
1418 1418  
1419 1419  Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module
1420 1420  
... ... @@ -1479,7 +1479,7 @@
1479 1479  (% style="text-align:center" %)
1480 1480  [[image:DVPEthernetVNETPortocol.png]]
1481 1481  
1482 -== **DVP serial protocol** ==
1705 +== **DVP serial** ==
1483 1483  
1484 1484  Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX
1485 1485  
... ... @@ -1515,7 +1515,7 @@
1515 1515  (% style="text-align:center" %)
1516 1516  [[image:Delta DVP PROTOCOLSerial232.png]]
1517 1517  
1518 -== **AS Ethernet Protocol** ==
1741 +== **AS Ethernet** ==
1519 1519  
1520 1520  **1)V-BOX Settings**
1521 1521  
... ... @@ -1560,19 +1560,18 @@
1560 1560  
1561 1561  [[image:image-20220831155157-3.png]]
1562 1562  
1563 -= Create communication with **Omron PLC** =
1786 += **Omron** =
1564 1564  
1565 -== **CP1 Series Protocol ** ==
1788 +== **CP1 Series** ==
1566 1566  
1567 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1790 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1568 1568  
1569 -== **CP2M Series Protocol** ==
1792 +== **CP2M Series** ==
1570 1570  
1571 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1794 +[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1572 1572  
1796 +== **EC55 Series ** ==
1573 1573  
1574 -== **EC55 Series Protocol** ==
1575 -
1576 1576  Supported device: EC55 temperature instrument
1577 1577  
1578 1578  **1)V-BOX Settings**
... ... @@ -1632,9 +1632,9 @@
1632 1632  * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1633 1633  * [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1634 1634  
1635 -= Create communication with Xinje** PLC** =
1857 += Xinje =
1636 1636  
1637 -== **XC serial protocol** ==
1859 +== **XC serial** ==
1638 1638  
1639 1639  **1)V-BOX Settings**
1640 1640  
... ... @@ -1676,7 +1676,7 @@
1676 1676  
1677 1677  [[image:image-20220831163441-4.png]]
1678 1678  
1679 -== **XD serial protocol** ==
1901 +== **XD serial** ==
1680 1680  
1681 1681  **1)V-BOX Settings**
1682 1682  
... ... @@ -1750,7 +1750,7 @@
1750 1750  
1751 1751  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1752 1752  
1753 -= Create communication with **Schneider PLC** =
1975 += **Schneider** =
1754 1754  
1755 1755  == **Schneider MODBUS RTU** ==
1756 1756  
... ... @@ -1784,7 +1784,7 @@
1784 1784  
1785 1785  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
1786 1786  
1787 -= Create communication with Inovance** PLC** =
2009 += Inovance =
1788 1788  
1789 1789  == **H3U serial protocol** ==
1790 1790  
... ... @@ -1836,9 +1836,9 @@
1836 1836  
1837 1837  [[image:image-20220831164731-4.png]]
1838 1838  
1839 -= Create communication with Panasonic** PLC** =
2061 += Panasonic =
1840 1840  
1841 -== **FP serial protocol** ==
2063 +== **FP serial** ==
1842 1842  
1843 1843  **1)V-BOX Settings**
1844 1844  
... ... @@ -1886,9 +1886,9 @@
1886 1886  
1887 1887  [[image:image-20220831165008-1.png]]
1888 1888  
1889 -= Create communication with LS** PLC** =
2111 += LS =
1890 1890  
1891 -== **XBC serial protocol** ==
2113 +== **XBC serial** ==
1892 1892  
1893 1893  **1)V-BOX Settings**
1894 1894  
... ... @@ -1940,7 +1940,7 @@
1940 1940  
1941 1941  [[image:image-20220831170215-2.png]]
1942 1942  
1943 -== **XGK FEnet Ethernet protocol** ==
2165 +== **XGK FEnet Ethernet** ==
1944 1944  
1945 1945  Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1946 1946  
... ... @@ -1983,8 +1983,76 @@
1983 1983  
1984 1984  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1985 1985  
1986 -= Create communication with **Modbus ** =
2208 += INVT =
1987 1987  
2210 +**1)V-BOX setting**
2211 +
2212 +|**Item**|**Settings**|**Note**
2213 +|Protocol|INVT_IVC2L|
2214 +|Connection|RS232|
2215 +|Baud rate|19200|
2216 +|Data bit|8|
2217 +|Parity|EVEN|
2218 +|Stop bit|1|
2219 +|PLC station No.|1
2220 +
2221 +**2)Address List**
2222 +
2223 +
2224 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
2225 +|(% colspan="1" rowspan="7" %)Bit|X|XOOO|0~~377|
2226 +|Y|YOOO|0~~377|
2227 +|M|MDDDD|0~~1999|
2228 +|SM|SMDDD|0~~255|
2229 +|S|SDDD|0~~991|
2230 +|T|TDDD|0~~255|
2231 +|C|CDDD|0~~255|
2232 +|(% rowspan="5" %)Word|D|DDDDD|0~~7999|
2233 +|SD|SDDDD|0~~255|
2234 +|Z|ZDD|0~~15|
2235 +|T|TDDD|0~~255|
2236 +|C|CDDD|0~~199|
2237 +|Double word|C|CDDD|200~~255|
2238 +
2239 +**3)Communication Settings**
2240 +
2241 +(% style="text-align:center" %)
2242 +[[image:盒子创建英威腾.png]]
2243 +
2244 +**4)PLC software**
2245 +
2246 +(% style="text-align:center" %)
2247 +[[image:英威腾软件.png]]
2248 +
2249 +**5)PLC setting **
2250 +
2251 +Open the INVI plc software, create a new project or open a project that has already been created
2252 +
2253 +(% style="text-align:center" %)
2254 +[[image:英威腾创建1.png]]
2255 +
2256 +Configure serial port parameters.
2257 +
2258 +(% style="text-align:center" %)
2259 +[[image:英威腾创建2.png]]
2260 +
2261 +PC connect PLC
2262 +
2263 +(% style="text-align:center" %)
2264 +[[image:英威腾创建3.png]]
2265 +
2266 +Download
2267 +
2268 +(% style="text-align:center" %)
2269 +[[image:英威腾下载.png]]
2270 +
2271 +**6)Cable Wiring**
2272 +
2273 +(% style="text-align:center" %)
2274 +[[image:wire.png]]
2275 +
2276 += **Modbus ** =
2277 +
1988 1988  == **MODBUS RTU Slave (All function)** ==
1989 1989  
1990 1990  Select the protocol "Modbus RTU Slave (All Fuction)",
... ... @@ -1994,6 +1994,86 @@
1994 1994  (% style="text-align:center" %)
1995 1995  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
1996 1996  
2287 +== **Modbus Meter** ==
2288 +
2289 +The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication.
2290 +
2291 +~1. Wiring the RS485 cable first. Because the pin 58 is A, the pin 59 is B for meter. Here we use the COM1 to connect. So the diagram like follows:
2292 +
2293 +(% style="text-align:center" %)
2294 +[[image:LinfeeTerminalDiagram.png]]
2295 +
2296 +2. Check the specific Modbus parameter in the communication menu from LED display.
2297 +
2298 +So from the following pictures, we can know the Meter Address is 85, Baud rate is 9600, CRC None.
2299 +
2300 +{{info}}
2301 +**✎Note: **Meter address usually corresponding to the Modbus Slave Station No. on the Modbus communication.
2302 +{{/info}}
2303 +
2304 +(% style="text-align:center" %)
2305 +[[image:MeterModbusAllView.png]]
2306 +
2307 +(% class="wikigeneratedid" %)
2308 +3. Set up the communication in the Configuration tab.
2309 +
2310 +(% class="wikigeneratedid" %)
2311 +Select the protocol as **ModBus RTU Slave (All Function)**. And set the communication parameters like below.
2312 +
2313 +(% style="text-align:center" %)
2314 +[[image:VNETCommunicationtabmeter.png]]
2315 +
2316 +(% class="wikigeneratedid" %)
2317 +4. Create new real-time monitoring tag accroding to Modbus manual
2318 +
2319 +(% class="wikigeneratedid" %)
2320 +Enter the address we want to read from the meter. The following table is intercept part of the manual for Linfee Modbus manual.
2321 +
2322 +(% class="wikigeneratedid" %)
2323 +**0x03/0x04 command data register address**:
2324 +
2325 +(% style="width:1142.22px" %)
2326 +|(% style="display:none" %) |=(% colspan="2" rowspan="1" style="width: 165px;" %)Address(% style="display:none" %) |=Description|=Data Format|=(% style="width: 254px;" %)Data Length(Word)|=(% style="width: 282px;" %)Remark
2327 +|(%%)(% style="display:none" %) (%%) HEX|(% style="width:107px" %)DEC|(%%)(% style="display:none" %) (%%) |(% style="width:100px" %) |(%%)(% style="display:none" %) (%%) |(% style="width:318px" %)
2328 +|(% style="width:107px" %)0x00|(% style="width:100px" %)0|Reserved| | |(% style="width:318px" %)
2329 +|(% style="width:107px" %)0x02|(% style="width:100px" %)2|Reserved| | |(% style="width:318px" %)
2330 +|(% style="width:107px" %)0x04|(% style="width:100px" %)4|Reserved| | |(% style="width:318px" %)
2331 +|(% style="width:107px" %)0x06|(% style="width:100px" %)6|Ua|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2332 +|(% style="width:107px" %)0x08|(% style="width:100px" %)8|Ub|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2333 +|(% style="width:107px" %)0x0A|(% style="width:100px" %)10|Uc|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2334 +|(% style="width:107px" %)0x0C|(% style="width:100px" %)12|Uab|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2335 +|(% style="width:107px" %)0x0E|(% style="width:100px" %)14|Ubc|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2336 +|(% style="width:107px" %)0x10|(% style="width:100px" %)16|Uca|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2337 +|(% style="width:107px" %)0x12|(% style="width:100px" %)18|Ia|float|2|(% style="width:318px" %)Phase Current data, Unit A
2338 +|(% style="width:107px" %)0x14|(% style="width:100px" %)20|Ib|float|2|(% style="width:318px" %)Phase Current data, Unit A
2339 +|(% style="width:107px" %)0x16|(% style="width:100px" %)22|Ic|float|2|(% style="width:318px" %)Phase Current data, Unit A
2340 +
2341 +{{info}}
2342 +**✎Note: **We usually use the Data Type 4 for read the Modbus registers(Function Code 03)
2343 +{{/info}}
2344 +
2345 +For example, here we want to read the Phase Voltage Ua (Modbus offset 0006), the Modbus register main No. requires input decimal number, and check whether the actual address has one address offset, so the tag configured like the following screenshot:
2346 +
2347 +(% style="text-align:center" %)
2348 +[[image:VNETModbusTagSettings.png]]
2349 +
2350 +(% style="text-align:center" %)
2351 +[[image:VNETModbusTagByteSettings.png]]
2352 +
2353 +{{info}}
2354 +**✎Note: **If the read value is incorrect, please check whether need to change the Byte order.
2355 +{{/info}}
2356 +
2357 +Set the Modbus Slave Station No.
2358 +
2359 +(% style="text-align:center" %)
2360 +[[image:ModbusStationSettings.png]]
2361 +
2362 +If the communication is setup successfully, the tag will show green light.
2363 +
2364 +(% style="text-align:center" %)
2365 +[[image:Monitoringtaggreenlight.png]]
2366 +
1997 1997  == **MODBUS RTU Master** ==
1998 1998  
1999 1999  Select the protocol "Modbus RTU Master",
1679563870401-671.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +39.3 KB
Content
1682233464031-639.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +15.9 KB
Content
CCW.Shell_E5Cwj4tUL3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +27.1 KB
Content
ControlStarCommunicate.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +26.0 KB
Content
ControlStarModbus.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content
ControlStarSystemBlock.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +46.3 KB
Content
Emerson.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
Ethernet.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +45.5 KB
Content
HollySysRS232.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +10.4 KB
Content
Hollysys LM Modbus RTU.gif
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.1 KB
Content
Hollysys485-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.5 KB
Content
Hollysys485box.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.4 KB
Content
LinfeeTerminalDiagram.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content
MeterModbusAddr.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +562.5 KB
Content
MeterModbusAllView.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +1.6 MB
Content
MeterModbusBaud.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +444.0 KB
Content
MeterModbusPara.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +532.0 KB
Content
ModbusStationSettings.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +35.8 KB
Content
Monitoringtaggreenlight.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.5 KB
Content
V-NET_Client setting.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +41.9 KB
Content
V-NET_Client_ADD.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +51.4 KB
Content
V-NET_Client_KOR0AHEA4M.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +14.2 KB
Content
V-NET_Client_TIiAymnjkx.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +12.8 KB
Content
V-NET_Client_TNBuqy7T5r.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +26.7 KB
Content
V-NET_Client_communication.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +25.5 KB
Content
V-NET_Client_iKKKhcgxm1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +35.9 KB
Content
V-NET_Client_t2Rg2wpSoY.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +53.7 KB
Content
VNETCommunicationtabmeter.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +31.0 KB
Content
VNETModbusTagByteSettings.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +31.2 KB
Content
VNETModbusTagSettings.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +35.7 KB
Content
conne ab plc.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +43.1 KB
Content
export.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +115.2 KB
Content
export1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +115.2 KB
Content
plc 软件.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +106.8 KB
Content
project create.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +65.5 KB
Content
software.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +25.8 KB
Content
v-net client vers.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +13.1 KB
Content
wire.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +137.2 KB
Content
企业微信截图_16889606174191.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +20.7 KB
Content
盒子创建英威腾.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +86.5 KB
Content
英威腾下载.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +49.0 KB
Content
英威腾创建1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +36.7 KB
Content
英威腾创建2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +115.7 KB
Content
英威腾创建3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +76.6 KB
Content
英威腾软件.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +52.6 KB
Content