Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 22.1
edited by Ben
on 2022/08/20 11:45
Change comment: There is no comment for this version
To version 35.1
edited by Ben
on 2022/08/24 10:52
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,5 @@
1 -= **1 General communication with PLC** =
1 += **Modbus RTU** =
2 2  
3 -== **Modbus RTU** ==
4 -
5 5  === **V-BOX as master** ===
6 6  
7 7  Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
... ... @@ -47,8 +47,10 @@
47 47  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
48 48  |0F (Write multiple bits)
49 49  
50 -= ** WECON PLC** =
48 += **WECON PLC** =
51 51  
50 +== **V-BOX 和维控 LX3V 串行通信** ==
51 +
52 52  Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
53 53  
54 54  **HMI Settings**
... ... @@ -84,17 +84,13 @@
84 84  
85 85  * **RS485**
86 86  
87 -(% style="text-align:center" %)
88 -[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]]
87 + [[image:image-20220822172124-1.png]]
89 89  
90 -(% style="text-align:center" %)
91 -[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
92 -
93 93  * **RS422**
94 94  
95 -(% style="text-align:center" %)
96 -[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]]
91 + [[image:image-20220822172228-2.png]]
97 97  
93 +
98 98  **✎Note:**
99 99  
100 100  * HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
... ... @@ -102,21 +102,22 @@
102 102  
103 103  [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
104 104  
105 -== HMI and Wecon LX5V serial communication ==
106 106  
107 -This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
102 +== **V-BOX and Wecon LX5V serial communication** ==
108 108  
104 +This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
105 +
109 109  **Software configuration of PLC**
110 110  
111 111  **1)PLC programming software**
112 112  
113 -[[image:image-20220810164710-1.png]]
110 +[[image:image-20220822172553-1.png]]
114 114  
115 115  **2)New PLC project**
116 116  
117 117  Click New Project and select the PLC model.
118 118  
119 -[[image:image-20220810172412-1.png]]
116 +[[image:image-20220822172623-2.png]]
120 120  
121 121  **3)Set Serial port parameters**
122 122  
... ... @@ -130,24 +130,25 @@
130 130  
131 131  Parity:No verification
132 132  
133 -[[image:image-20220810165759-3.png]]
130 +[[image:image-20220822172657-3.png]]
134 134  
135 135  **4)Registers list**
136 136  
137 -[[image:image-20220811102219-3.png]]
134 +[[image:image-20220822172730-4.png]]
138 138  
139 -**HMI software configuration**
136 +**V-BOX software configuration**
140 140  
141 -**1)HMI programming software**
138 +**1)V-BOX programming software**
142 142  
143 - [[image:image-20220810171237-4.png]]
140 + [[image:image-20220824104124-1.png]]
144 144  
145 -**2)New HMI project**
142 +**2)V-NET add device**
146 146  
147 -Click New Project and select the HMI model.
144 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device.
148 148  
149 -[[image:image-20220810172010-5.png]]
146 +[[image:image-20220824104909-2.png]]
150 150  
148 +
151 151  **3)Set communication port parameters**
152 152  
153 153  Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
... ... @@ -162,6 +162,7 @@
162 162  
163 163  [[image:image-20220811104012-1.png]]
164 164  
163 +
165 165  **hardware connection**
166 166  
167 167  **1)Hardware wiring diagram**
... ... @@ -168,6 +168,8 @@
168 168  
169 169  This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
170 170  
170 +
171 +
171 171  [[image:image-20220811103005-4.png]]
172 172  
173 173  [[image:image-20220811103227-7.png]]
... ... @@ -174,7 +174,7 @@
174 174  
175 175  The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
176 176  
177 -== HMI and Wecon LX5V-N Ethernet communication ==
178 +== **V-BOX and Wecon LX5V-N Ethernet communication** ==
178 178  
179 179   This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
180 180  
... ... @@ -247,10 +247,9 @@
247 247  (% style="text-align:center" %)
248 248  [[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
249 249  
250 -(% class="wikigeneratedid" %)
251 -== **Rockwell** ==
251 += **Rockwell PLC** =
252 252  
253 -== **Communication with Allen-Bradley CompactLogix L1769** ==
253 +== **Communication with AB CompactLogix L1769** ==
254 254  
255 255  (((
256 256  (((
... ... @@ -453,6 +453,14 @@
453 453  
454 454  (((
455 455  The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC.
456 +
457 +
458 +== **Allen-Bradley Ethernet DF1** ==
459 +
460 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
461 +
462 +
463 += **Siemens PLC** =
456 456  )))
457 457  )))
458 458  
... ... @@ -460,14 +460,12 @@
460 460  
461 461  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
462 462  
463 -== **Allen-Bradley Ethernet DF1** ==
464 -
465 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
466 -
467 467  == **Communication with S7-200 Smart** ==
468 468  
469 469  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
470 470  
475 += **Delta PLC** =
476 +
471 471  == **Delta DVP Ethernet** ==
472 472  
473 473  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
image-20220820164423-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +18.4 KB
Content
image-20220822172124-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +38.7 KB
Content
image-20220822172228-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +48.8 KB
Content
image-20220822172553-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +19.9 KB
Content
image-20220822172623-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +111.2 KB
Content
image-20220822172657-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +141.6 KB
Content
image-20220822172730-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +130.7 KB
Content
image-20220824104124-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +14.6 KB
Content
image-20220824104909-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +278.8 KB
Content