Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2000,13 +2000,58 @@ 2000 2000 2001 2001 The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication. 2002 2002 2003 -~1. CheckthespecificModbus parameterinthe communicationmenufromLED display.2003 +~1. Wiring the RS485 cable first. Because the pin 58 is A, the pin 59 is B for meter. Here we use the COM1 to connect. So the diagram like follows: 2004 2004 2005 -So from the following pictures, 2005 +(% style="text-align:center" %) 2006 +[[image:LinfeeTerminalDiagram.png]] 2006 2006 2008 +2. Check the specific Modbus parameter in the communication menu from LED display. 2009 + 2010 +So from the following pictures, we can know the Meter Address is 85, Baud rate is 9600, CRC None. 2011 + 2012 +{{info}} 2013 +**✎Note: **Meter address usually corresponding to the Modbus Slave Station No. on the Modbus communication. 2014 +{{/info}} 2015 + 2007 2007 (% style="text-align:center" %) 2008 2008 [[image:MeterModbusAllView.png]] 2009 2009 2019 +(% class="wikigeneratedid" %) 2020 +3. Set up the communication in the Configuration tab. 2021 + 2022 +(% class="wikigeneratedid" %) 2023 +Select the protocol as **ModBus RTU Slave (All Function)**. And set the communication parameters like below. 2024 + 2025 +(% style="text-align:center" %) 2026 +[[image:VNETCommunicationtabmeter.png]] 2027 + 2028 +(% class="wikigeneratedid" %) 2029 +4. Create new real-time monitoring tag accroding to Modbus manual 2030 + 2031 +(% class="wikigeneratedid" %) 2032 +Enter the address we want to read from the meter. The following table is intercept part of the manual for Linfee Modbus manual. 2033 + 2034 +(% class="wikigeneratedid" %) 2035 +**0x03/0x04 command data register address**: 2036 + 2037 +(% style="width:1079.22px" %) 2038 +|(% style="display:none" %) |=(% colspan="2" rowspan="1" style="width: 165px;" %)Address(% style="display:none" %) |=Description|=Data Format|=Data Length(Word)|=Remark 2039 +|(%%)(% style="display:none" %) (%%) |(% style="width:107px" %)HEX|(%%)(% style="display:none" %) (%%) |(% style="width:100px" %)DEC|(%%)(% style="display:none" %) (%%) | | | | 2040 +|(% style="width:107px" %)0x00|(% style="width:100px" %)0|Reserved| | | 2041 +|(% style="width:107px" %)0x02|(% style="width:100px" %)2|Reserved| | | 2042 +|(% style="width:107px" %)0x04|(% style="width:100px" %)4|Reserved| | | 2043 +|(% style="width:107px" %)0x06|(% style="width:100px" %)6|Ua|float|2|Phase Voltage data, Unit V 2044 +|(% style="width:107px" %)0x08|(% style="width:100px" %)8|Ub|float|2|Phase Voltage data, Unit V 2045 +|(% style="width:107px" %)0x0A|(% style="width:100px" %)10|Uc|float|2|Phase Voltage data, Unit V 2046 +|(% style="width:107px" %)0x0C|(% style="width:100px" %)12|Uab|float|2|Line Voltage data, Unit V 2047 +|(% style="width:107px" %)0x0E|(% style="width:100px" %)14|Ubc|float|2|Line Voltage data, Unit V 2048 +|(% style="width:107px" %)0x10|(% style="width:100px" %)16|Uca|float|2|Line Voltage data, Unit V 2049 +|(% style="width:107px" %)0x12|(% style="width:100px" %)18|Ia|float|2|Phase Current data, Unit A 2050 +|(% style="width:107px" %)0x14|(% style="width:100px" %)20|Ib|float|2|Phase Current data, Unit A 2051 +|(% style="width:107px" %)0x16|(% style="width:100px" %)22|Ic|float|2|Phase Current data, Unit A 2052 + 2053 + 2054 + 2010 2010 == **MODBUS RTU Master** == 2011 2011 2012 2012 Select the protocol "Modbus RTU Master",
- LinfeeTerminalDiagram.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.6 KB - Content
- VNETCommunicationtabmeter.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.0 KB - Content