Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 6 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2020,11 +2020,62 @@ 2020 2020 3. Set up the communication in the Configuration tab. 2021 2021 2022 2022 (% class="wikigeneratedid" %) 2023 -Select the protocol as ModBus RTU Slave (All Function). 2023 +Select the protocol as **ModBus RTU Slave (All Function)**. And set the communication parameters like below. 2024 2024 2025 2025 (% style="text-align:center" %) 2026 -[[image:VNET ModbusConfigurationMeter.png]]2026 +[[image:VNETCommunicationtabmeter.png]] 2027 2027 2028 +(% class="wikigeneratedid" %) 2029 +4. Create new real-time monitoring tag accroding to Modbus manual 2030 + 2031 +(% class="wikigeneratedid" %) 2032 +Enter the address we want to read from the meter. The following table is intercept part of the manual for Linfee Modbus manual. 2033 + 2034 +(% class="wikigeneratedid" %) 2035 +**0x03/0x04 command data register address**: 2036 + 2037 +(% style="width:1142.22px" %) 2038 +|(% style="display:none" %) |=(% colspan="2" rowspan="1" style="width: 165px;" %)Address(% style="display:none" %) |=Description|=Data Format|=(% style="width: 254px;" %)Data Length(Word)|=(% style="width: 282px;" %)Remark 2039 +|(%%)(% style="display:none" %) (%%) HEX|(% style="width:107px" %)DEC|(%%)(% style="display:none" %) (%%) |(% style="width:100px" %) |(%%)(% style="display:none" %) (%%) |(% style="width:318px" %) 2040 +|(% style="width:107px" %)0x00|(% style="width:100px" %)0|Reserved| | |(% style="width:318px" %) 2041 +|(% style="width:107px" %)0x02|(% style="width:100px" %)2|Reserved| | |(% style="width:318px" %) 2042 +|(% style="width:107px" %)0x04|(% style="width:100px" %)4|Reserved| | |(% style="width:318px" %) 2043 +|(% style="width:107px" %)0x06|(% style="width:100px" %)6|Ua|float|2|(% style="width:318px" %)Phase Voltage data, Unit V 2044 +|(% style="width:107px" %)0x08|(% style="width:100px" %)8|Ub|float|2|(% style="width:318px" %)Phase Voltage data, Unit V 2045 +|(% style="width:107px" %)0x0A|(% style="width:100px" %)10|Uc|float|2|(% style="width:318px" %)Phase Voltage data, Unit V 2046 +|(% style="width:107px" %)0x0C|(% style="width:100px" %)12|Uab|float|2|(% style="width:318px" %)Line Voltage data, Unit V 2047 +|(% style="width:107px" %)0x0E|(% style="width:100px" %)14|Ubc|float|2|(% style="width:318px" %)Line Voltage data, Unit V 2048 +|(% style="width:107px" %)0x10|(% style="width:100px" %)16|Uca|float|2|(% style="width:318px" %)Line Voltage data, Unit V 2049 +|(% style="width:107px" %)0x12|(% style="width:100px" %)18|Ia|float|2|(% style="width:318px" %)Phase Current data, Unit A 2050 +|(% style="width:107px" %)0x14|(% style="width:100px" %)20|Ib|float|2|(% style="width:318px" %)Phase Current data, Unit A 2051 +|(% style="width:107px" %)0x16|(% style="width:100px" %)22|Ic|float|2|(% style="width:318px" %)Phase Current data, Unit A 2052 + 2053 +{{info}} 2054 +**✎Note: **We usually use the Data Type 4 for read the Modbus registers(Function Code 03) 2055 +{{/info}} 2056 + 2057 +For example, here we want to read the Phase Voltage Ua (Modbus offset 0006), the Modbus register main No. requires input decimal number, and check whether the actual address has one address offset, so the tag configured like the following screenshot: 2058 + 2059 +(% style="text-align:center" %) 2060 +[[image:VNETModbusTagSettings.png]] 2061 + 2062 +(% style="text-align:center" %) 2063 +[[image:VNETModbusTagByteSettings.png]] 2064 + 2065 +{{info}} 2066 +**✎Note: **If the read value is incorrect, please check whether need to change the Byte order. 2067 +{{/info}} 2068 + 2069 +Set the Modbus Slave Station No. 2070 + 2071 +(% style="text-align:center" %) 2072 +[[image:ModbusStationSettings.png]] 2073 + 2074 +If the communication is setup successfully, the tag will show green light. 2075 + 2076 +(% style="text-align:center" %) 2077 +[[image:Monitoringtaggreenlight.png]] 2078 + 2028 2028 == **MODBUS RTU Master** == 2029 2029 2030 2030 Select the protocol "Modbus RTU Master",
- 1679563870401-671.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +39.3 KB - Content
- ModbusStationSettings.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.8 KB - Content
- Monitoringtaggreenlight.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.5 KB - Content
- VNETCommunicationtabmeter.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.0 KB - Content
- VNETModbusTagByteSettings.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.2 KB - Content
- VNETModbusTagSettings.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.7 KB - Content