... ... @@ -527,8 +527,6 @@
527 527  
528 528  == **CROUZET M3 (FBD)** ==
529 529  
530 -Support Series: Crouzet Millenium 3 CD12/CB12
531 -
532 532  **1)V-BOX setting**
533 533  
534 534  |=Item|=Recommended |=Note
... ... @@ -1996,39 +1996,6 @@
1996 1996  (% style="text-align:center" %)
1997 1997  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
1998 1998  
1999 -== **Communicate with Modbus Meter** ==
2000 -
2001 -The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication.
2002 -
2003 -~1. Wiring the RS485 cable first. Because the pin 58 is A, the pin 59 is B for meter. Here we use the COM1 to connect. So the diagram like follows:
2004 -
2005 -(% style="text-align:center" %)
2006 -[[image:LinfeeTerminalDiagram.png]]
2007 -
2008 -2. Check the specific Modbus parameter in the communication menu from LED display.
2009 -
2010 -So from the following pictures, we can know the Meter Address is 85, Baud rate is 9600, CRC None.
2011 -
2012 -{{info}}
2013 -**✎Note: **Meter address usually corresponding to the Modbus Slave Station No. on the Modbus communication.
2014 -{{/info}}
2015 -
2016 -(% style="text-align:center" %)
2017 -[[image:MeterModbusAllView.png]]
2018 -
2019 -(% class="wikigeneratedid" %)
2020 -3. Set up the communication in the Configuration tab.
2021 -
2022 -(% class="wikigeneratedid" %)
2023 -Select the protocol as **ModBus RTU Slave (All Function)**. And set the communication parameters like below.
2024 -
2025 -(% style="text-align:center" %)
2026 -[[image:VNETCommunicationtabmeter.png]]
2027 -
2028 -(% class="wikigeneratedid" %)
2029 -4. Create new real-time monitoring tag.
2030 -
2031 -
2032 2032  == **MODBUS RTU Master** ==
2033 2033  
2034 2034  Select the protocol "Modbus RTU Master",
LinfeeTerminalDiagram.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -8.6 KB
Content
MeterModbusAddr.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -562.5 KB
Content
MeterModbusAllView.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -1.6 MB
Content
MeterModbusBaud.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -444.0 KB
Content
MeterModbusPara.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -532.0 KB
Content
VNETCommunicationtabmeter.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -31.0 KB
Content