Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2026,9 +2026,39 @@ 2026 2026 [[image:VNETCommunicationtabmeter.png]] 2027 2027 2028 2028 (% class="wikigeneratedid" %) 2029 -4. Create new real-time monitoring tag .2029 +4. Create new real-time monitoring tag accroding to Modbus manual 2030 2030 2031 +(% class="wikigeneratedid" %) 2032 +Enter the address we want to read from the meter. The following table is intercept part of the manual for Linfee Modbus manual. 2031 2031 2034 +(% class="wikigeneratedid" %) 2035 +**0x03/0x04 command data register address**: 2036 + 2037 +(% style="width:1142.22px" %) 2038 +|(% style="display:none" %) |=(% colspan="2" rowspan="1" style="width: 165px;" %)Address(% style="display:none" %) |=Description|=Data Format|=(% style="width: 254px;" %)Data Length(Word)|=(% style="width: 282px;" %)Remark 2039 +|(%%)(% style="display:none" %) (%%) HEX|(% style="width:107px" %)DEC|(%%)(% style="display:none" %) (%%) |(% style="width:100px" %) |(%%)(% style="display:none" %) (%%) |(% style="width:318px" %) 2040 +|(% style="width:107px" %)0x00|(% style="width:100px" %)0|Reserved| | |(% style="width:318px" %) 2041 +|(% style="width:107px" %)0x02|(% style="width:100px" %)2|Reserved| | |(% style="width:318px" %) 2042 +|(% style="width:107px" %)0x04|(% style="width:100px" %)4|Reserved| | |(% style="width:318px" %) 2043 +|(% style="width:107px" %)0x06|(% style="width:100px" %)6|Ua|float|2|(% style="width:318px" %)Phase Voltage data, Unit V 2044 +|(% style="width:107px" %)0x08|(% style="width:100px" %)8|Ub|float|2|(% style="width:318px" %)Phase Voltage data, Unit V 2045 +|(% style="width:107px" %)0x0A|(% style="width:100px" %)10|Uc|float|2|(% style="width:318px" %)Phase Voltage data, Unit V 2046 +|(% style="width:107px" %)0x0C|(% style="width:100px" %)12|Uab|float|2|(% style="width:318px" %)Line Voltage data, Unit V 2047 +|(% style="width:107px" %)0x0E|(% style="width:100px" %)14|Ubc|float|2|(% style="width:318px" %)Line Voltage data, Unit V 2048 +|(% style="width:107px" %)0x10|(% style="width:100px" %)16|Uca|float|2|(% style="width:318px" %)Line Voltage data, Unit V 2049 +|(% style="width:107px" %)0x12|(% style="width:100px" %)18|Ia|float|2|(% style="width:318px" %)Phase Current data, Unit A 2050 +|(% style="width:107px" %)0x14|(% style="width:100px" %)20|Ib|float|2|(% style="width:318px" %)Phase Current data, Unit A 2051 +|(% style="width:107px" %)0x16|(% style="width:100px" %)22|Ic|float|2|(% style="width:318px" %)Phase Current data, Unit A 2052 + 2053 +{{info}} 2054 +**✎Note: **We usually use the Data Type 4 for read the Modbus registers(Function Code 03) 2055 +{{/info}} 2056 + 2057 +For example, here we want to read the Phase Voltage Ua (Modbus offset 0006), so the tag configured like the following screenshot: 2058 + 2059 +(% style="text-align:center" %) 2060 +[[image:VNETModbusTagSettings.png]] 2061 + 2032 2032 == **MODBUS RTU Master** == 2033 2033 2034 2034 Select the protocol "Modbus RTU Master",
- VNETModbusTagSettings.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.7 KB - Content