Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 5 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2034,48 +2034,24 @@ 2034 2034 (% class="wikigeneratedid" %) 2035 2035 **0x03/0x04 command data register address**: 2036 2036 2037 -(% style="width:1 142.22px" %)2038 -|(% style="display:none" %) |=(% colspan="2" rowspan="1" style="width: 165px;" %)Address(% style="display:none" %) |=Description|=Data Format|= (% style="width: 254px;" %)Data Length(Word)|=(% style="width: 282px;" %)Remark2039 -|(%%)(% style="display:none" %) (%%) HEX|(% style="width:107px" %)DEC|(%%)(% style="display:none" %) (%%) |(% style="width:100px" %)(%style="width:318px"%)2040 -|(% style="width:107px" %)0x00|(% style="width:100px" %)0|Reserved| | | (%style="width:318px" %)2041 -|(% style="width:107px" %)0x02|(% style="width:100px" %)2|Reserved| | | (%style="width:318px" %)2042 -|(% style="width:107px" %)0x04|(% style="width:100px" %)4|Reserved| | | (%style="width:318px" %)2043 -|(% style="width:107px" %)0x06|(% style="width:100px" %)6|Ua|float|2| (% style="width:318px" %)Phase Voltage data, Unit V2044 -|(% style="width:107px" %)0x08|(% style="width:100px" %)8|Ub|float|2| (% style="width:318px" %)Phase Voltage data, Unit V2045 -|(% style="width:107px" %)0x0A|(% style="width:100px" %)10|Uc|float|2| (% style="width:318px" %)Phase Voltage data, Unit V2046 -|(% style="width:107px" %)0x0C|(% style="width:100px" %)12|Uab|float|2| (% style="width:318px" %)Line Voltage data, Unit V2047 -|(% style="width:107px" %)0x0E|(% style="width:100px" %)14|Ubc|float|2| (% style="width:318px" %)Line Voltage data, Unit V2048 -|(% style="width:107px" %)0x10|(% style="width:100px" %)16|Uca|float|2| (% style="width:318px" %)Line Voltage data, Unit V2049 -|(% style="width:107px" %)0x12|(% style="width:100px" %)18|Ia|float|2| (% style="width:318px" %)Phase Current data, Unit A2050 -|(% style="width:107px" %)0x14|(% style="width:100px" %)20|Ib|float|2| (% style="width:318px" %)Phase Current data, Unit A2051 -|(% style="width:107px" %)0x16|(% style="width:100px" %)22|Ic|float|2| (% style="width:318px" %)Phase Current data, Unit A2037 +(% style="width:1079.22px" %) 2038 +|(% style="display:none" %) |=(% colspan="2" rowspan="1" style="width: 165px;" %)Address(% style="display:none" %) |=Description|=Data Format|=Data Length(Word)|=Remark 2039 +|(%%)(% style="display:none" %) (%%) |(% style="width:107px" %)HEX|(%%)(% style="display:none" %) (%%) |(% style="width:100px" %)DEC|(%%)(% style="display:none" %) (%%) | | | | 2040 +|(% style="width:107px" %)0x00|(% style="width:100px" %)0|Reserved| | | 2041 +|(% style="width:107px" %)0x02|(% style="width:100px" %)2|Reserved| | | 2042 +|(% style="width:107px" %)0x04|(% style="width:100px" %)4|Reserved| | | 2043 +|(% style="width:107px" %)0x06|(% style="width:100px" %)6|Ua|float|2|Phase Voltage data, Unit V 2044 +|(% style="width:107px" %)0x08|(% style="width:100px" %)8|Ub|float|2|Phase Voltage data, Unit V 2045 +|(% style="width:107px" %)0x0A|(% style="width:100px" %)10|Uc|float|2|Phase Voltage data, Unit V 2046 +|(% style="width:107px" %)0x0C|(% style="width:100px" %)12|Uab|float|2|Line Voltage data, Unit V 2047 +|(% style="width:107px" %)0x0E|(% style="width:100px" %)14|Ubc|float|2|Line Voltage data, Unit V 2048 +|(% style="width:107px" %)0x10|(% style="width:100px" %)16|Uca|float|2|Line Voltage data, Unit V 2049 +|(% style="width:107px" %)0x12|(% style="width:100px" %)18|Ia|float|2|Phase Current data, Unit A 2050 +|(% style="width:107px" %)0x14|(% style="width:100px" %)20|Ib|float|2|Phase Current data, Unit A 2051 +|(% style="width:107px" %)0x16|(% style="width:100px" %)22|Ic|float|2|Phase Current data, Unit A 2052 2052 2053 -{{info}} 2054 -**✎Note: **We usually use the Data Type 4 for read the Modbus registers(Function Code 03) 2055 -{{/info}} 2053 + 2056 2056 2057 -For example, here we want to read the Phase Voltage Ua (Modbus offset 0006), the Modbus register main No. requires input decimal number, and check whether the actual address has one address offset, so the tag configured like the following screenshot: 2058 - 2059 -(% style="text-align:center" %) 2060 -[[image:VNETModbusTagSettings.png]] 2061 - 2062 -(% style="text-align:center" %) 2063 -[[image:VNETModbusTagByteSettings.png]] 2064 - 2065 -{{info}} 2066 -**✎Note: **If the read value is incorrect, please check whether need to change the Byte order. 2067 -{{/info}} 2068 - 2069 -Set the Modbus Slave Station No. 2070 - 2071 -(% style="text-align:center" %) 2072 -[[image:ModbusStationSettings.png]] 2073 - 2074 -If the communication is setup successfully, the tag will show green light. 2075 - 2076 -(% style="text-align:center" %) 2077 -[[image:Monitoringtaggreenlight.png]] 2078 - 2079 2079 == **MODBUS RTU Master** == 2080 2080 2081 2081 Select the protocol "Modbus RTU Master",
- 1679563870401-671.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -39.3 KB - Content
- ModbusStationSettings.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -35.8 KB - Content
- Monitoringtaggreenlight.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -7.5 KB - Content
- VNETModbusTagByteSettings.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -31.2 KB - Content
- VNETModbusTagSettings.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -35.7 KB - Content