... ... @@ -2034,48 +2034,24 @@
2034 2034  (% class="wikigeneratedid" %)
2035 2035  **0x03/0x04 command data register address**:
2036 2036  
2037 -(% style="width:1142.22px" %)
2038 -|(% style="display:none" %) |=(% colspan="2" rowspan="1" style="width: 165px;" %)Address(% style="display:none" %) |=Description|=Data Format|=(% style="width: 254px;" %)Data Length(Word)|=(% style="width: 282px;" %)Remark
2039 -|(%%)(% style="display:none" %) (%%) HEX|(% style="width:107px" %)DEC|(%%)(% style="display:none" %) (%%) |(% style="width:100px" %) |(%%)(% style="display:none" %) (%%) |(% style="width:318px" %)
2040 -|(% style="width:107px" %)0x00|(% style="width:100px" %)0|Reserved| | |(% style="width:318px" %)
2041 -|(% style="width:107px" %)0x02|(% style="width:100px" %)2|Reserved| | |(% style="width:318px" %)
2042 -|(% style="width:107px" %)0x04|(% style="width:100px" %)4|Reserved| | |(% style="width:318px" %)
2043 -|(% style="width:107px" %)0x06|(% style="width:100px" %)6|Ua|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2044 -|(% style="width:107px" %)0x08|(% style="width:100px" %)8|Ub|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2045 -|(% style="width:107px" %)0x0A|(% style="width:100px" %)10|Uc|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2046 -|(% style="width:107px" %)0x0C|(% style="width:100px" %)12|Uab|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2047 -|(% style="width:107px" %)0x0E|(% style="width:100px" %)14|Ubc|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2048 -|(% style="width:107px" %)0x10|(% style="width:100px" %)16|Uca|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2049 -|(% style="width:107px" %)0x12|(% style="width:100px" %)18|Ia|float|2|(% style="width:318px" %)Phase Current data, Unit A
2050 -|(% style="width:107px" %)0x14|(% style="width:100px" %)20|Ib|float|2|(% style="width:318px" %)Phase Current data, Unit A
2051 -|(% style="width:107px" %)0x16|(% style="width:100px" %)22|Ic|float|2|(% style="width:318px" %)Phase Current data, Unit A
2037 +(% style="width:1079.22px" %)
2038 +|(% style="display:none" %) |=(% colspan="2" rowspan="1" style="width: 165px;" %)Address(% style="display:none" %) |=Description|=Data Format|=Data Length(Word)|=Remark
2039 +|(%%)(% style="display:none" %) (%%) |(% style="width:107px" %)HEX|(%%)(% style="display:none" %) (%%) |(% style="width:100px" %)DEC|(%%)(% style="display:none" %) (%%) | | | |
2040 +|(% style="width:107px" %)0x00|(% style="width:100px" %)0|Reserved| | |
2041 +|(% style="width:107px" %)0x02|(% style="width:100px" %)2|Reserved| | |
2042 +|(% style="width:107px" %)0x04|(% style="width:100px" %)4|Reserved| | |
2043 +|(% style="width:107px" %)0x06|(% style="width:100px" %)6|Ua|float|2|Phase Voltage data, Unit V
2044 +|(% style="width:107px" %)0x08|(% style="width:100px" %)8|Ub|float|2|Phase Voltage data, Unit V
2045 +|(% style="width:107px" %)0x0A|(% style="width:100px" %)10|Uc|float|2|Phase Voltage data, Unit V
2046 +|(% style="width:107px" %)0x0C|(% style="width:100px" %)12|Uab|float|2|Line Voltage data, Unit V
2047 +|(% style="width:107px" %)0x0E|(% style="width:100px" %)14|Ubc|float|2|Line Voltage data, Unit V
2048 +|(% style="width:107px" %)0x10|(% style="width:100px" %)16|Uca|float|2|Line Voltage data, Unit V
2049 +|(% style="width:107px" %)0x12|(% style="width:100px" %)18|Ia|float|2|Phase Current data, Unit A
2050 +|(% style="width:107px" %)0x14|(% style="width:100px" %)20|Ib|float|2|Phase Current data, Unit A
2051 +|(% style="width:107px" %)0x16|(% style="width:100px" %)22|Ic|float|2|Phase Current data, Unit A
2052 2052  
2053 -{{info}}
2054 -**✎Note: **We usually use the Data Type 4 for read the Modbus registers(Function Code 03)
2055 -{{/info}}
2053 +
2056 2056  
2057 -For example, here we want to read the Phase Voltage Ua (Modbus offset 0006), the Modbus register main No. requires input decimal number, and check whether the actual address has one address offset, so the tag configured like the following screenshot:
2058 -
2059 -(% style="text-align:center" %)
2060 -[[image:VNETModbusTagSettings.png]]
2061 -
2062 -(% style="text-align:center" %)
2063 -[[image:VNETModbusTagByteSettings.png]]
2064 -
2065 -{{info}}
2066 -**✎Note: **If the read value is incorrect, please check whether need to change the Byte order.
2067 -{{/info}}
2068 -
2069 -Set the Modbus Slave Station No.
2070 -
2071 -(% style="text-align:center" %)
2072 -[[image:ModbusStationSettings.png]]
2073 -
2074 -If the communication is setup successfully, the tag will show green light.
2075 -
2076 -(% style="text-align:center" %)
2077 -[[image:Monitoringtaggreenlight.png]]
2078 -
2079 2079  == **MODBUS RTU Master** ==
2080 2080  
2081 2081  Select the protocol "Modbus RTU Master",
1679563870401-671.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -39.3 KB
Content
ModbusStationSettings.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -35.8 KB
Content
Monitoringtaggreenlight.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -7.5 KB
Content
VNETModbusTagByteSettings.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -31.2 KB
Content
VNETModbusTagSettings.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -35.7 KB
Content