Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 229.1
edited by Hunter
on 2023/03/23 19:12
Change comment: There is no comment for this version
To version 231.1
edited by Theodore Xu
on 2023/04/23 15:42
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.AiXia
Content
... ... @@ -519,6 +519,90 @@
519 519  (((
520 520  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
521 521  
522 +
523 += **Micro850_FreeTag Protocol(new)** =
524 +
525 +This example introduces the establishment of Ethernet communication between Wecon V-box and 2080-LC50-48QWB,Micro850. It is introduced through three parts: PLC software configuration, V-box software configuration.
526 +
527 +(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
528 +(((
529 +**Software configuration of PLC**
530 +)))
531 +
532 +(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %)
533 +(((
534 +**1)PLC programming software:Connected Components Workbench™**
535 +
536 +(% style="text-align:center" %)
537 +[[image:software.png]]
538 +
539 +**2)New PLC project**
540 +
541 +Click New Project and select the PLC model.
542 +
543 +(% style="text-align:center" %)
544 +[[image:project create.png]]
545 +
546 +**3)Set Ethernet parameters**
547 +
548 +Follow the steps below to configure Ethernet parameters
549 +
550 +PLC IP address:192.168.39.56
551 +
552 +default gateway:192.168.39.1
553 +
554 +subnet mask:255.255.255.0
555 +
556 +(% style="text-align:center" %)
557 +[[image:Ethernet.png]]
558 +
559 +**4)connect PLC**
560 +
561 +**When downloading the setting, need to change the status of the PLC to PRG**
562 +
563 +(% style="text-align:center" %)
564 +[[image:conne ab plc.png]]
565 +
566 +**V-box software configuration**
567 +
568 +**1)V-box programming software**
569 +
570 +(% style="text-align:center" %)
571 +[[image:v-net client vers.png]]
572 +
573 +**2)Set communication port parameters**
574 +
575 +In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
576 +
577 +(% style="text-align:center" %)
578 +[[image:V-NET_Client_t2Rg2wpSoY.png]]
579 +
580 +The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
581 +
582 +(% style="text-align:center" %)
583 +[[image:V-NET_Client_communication.png]]
584 +
585 +Export variables from PLC, select CSV file, comma delimited. After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png"]]icon add label.
586 +
587 +(% style="text-align:center" %)
588 +[[image:export1.png]]
589 +
590 +(% style="text-align:center" %)
591 +[[image:CCW.Shell_E5Cwj4tUL3.png]]
592 +
593 +(% style="text-align:center" %)
594 +[[image:V-NET_Client_iKKKhcgxm1.png]]
595 +
596 +**3)Engineering production**
597 +
598 +According to your own needs, use the V-NET client software to edit the required data monitoring points.
599 +
600 +(% style="text-align:center" %)
601 +[[image:V-NET_Client_KOR0AHEA4M.png]]
602 +
603 +
604 +)))
605 +
522 522  == **Ethernet DF1 Protocol** ==
523 523  
524 524  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
1682233464031-639.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +15.9 KB
Content
CCW.Shell_E5Cwj4tUL3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +27.1 KB
Content
Ethernet.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +45.5 KB
Content
V-NET_Client setting.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +41.9 KB
Content
V-NET_Client_ADD.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +51.4 KB
Content
V-NET_Client_KOR0AHEA4M.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +14.2 KB
Content
V-NET_Client_TIiAymnjkx.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +12.8 KB
Content
V-NET_Client_communication.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +25.5 KB
Content
V-NET_Client_iKKKhcgxm1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +35.9 KB
Content
V-NET_Client_t2Rg2wpSoY.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +53.7 KB
Content
conne ab plc.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +43.1 KB
Content
export.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +115.2 KB
Content
export1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +115.2 KB
Content
project create.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +65.5 KB
Content
software.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +25.8 KB
Content
v-net client vers.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +13.1 KB
Content