Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 230.1
edited by Theodore Xu
on 2023/04/23 15:41
Change comment: There is no comment for this version
To version 243.1
edited by Hunter
on 2023/07/05 11:35
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.AiXia
1 +XWiki.Hunter
Content
... ... @@ -2,6 +2,8 @@
2 2  
3 3  == **LX3V Serial Protocol** ==
4 4  
5 +== **xcvxvxcv** ==
6 +
5 5  Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
7 7  **1)V-BOX setting**
... ... @@ -520,6 +520,8 @@
520 520  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
521 521  
522 522  
525 +== **Micro850_FreeTag Protocol(new)** ==
526 +
523 523  This example introduces the establishment of Ethernet communication between Wecon V-box and 2080-LC50-48QWB,Micro850. It is introduced through three parts: PLC software configuration, V-box software configuration.
524 524  
525 525  (% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
... ... @@ -580,7 +580,7 @@
580 580  (% style="text-align:center" %)
581 581  [[image:V-NET_Client_communication.png]]
582 582  
583 -Export variables from PLC, select CSV file, comma delimited. After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png"]]icon add label.
587 +Export variables from PLC, select CSV file, comma delimited.(% id="cke_bm_1950S" style="display:none" %)
584 584  
585 585  (% style="text-align:center" %)
586 586  [[image:export1.png]]
... ... @@ -588,8 +588,10 @@
588 588  (% style="text-align:center" %)
589 589  [[image:CCW.Shell_E5Cwj4tUL3.png]]
590 590  
595 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png"]]icon add label.
596 +
591 591  (% style="text-align:center" %)
592 -[[image:V-NET_Client_iKKKhcgxm1.png]]
598 +[[image:V-NET_Client_TNBuqy7T5r.png]]
593 593  
594 594  **3)Engineering production**
595 595  
... ... @@ -659,6 +659,102 @@
659 659  **✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details.
660 660  {{/info}}
661 661  
668 += Create communication with EMERSON PLC =
669 +
670 +== **RTU Slave Protocol** ==
671 +
672 +Supported series: EC10 series
673 +
674 +**1)V-BOX setting**
675 +
676 +|**Items**|**Settings**|**Note**
677 +|Protocol|Emerson 984 RTU Slave MODBUS|
678 +|Connection|RS485|
679 +|Baud rate|19200|
680 +|Data bit|8|
681 +|Parity|EVEN|
682 +|Stop bit|1|
683 +|Device station No.|1|Need to be same as the PLC setting
684 +
685 +(% class="wikigeneratedid" %)
686 +**2)PLC Setting**
687 +
688 +(% class="wikigeneratedid" %)
689 +Remember to use the Control Star to enable the Modbus RTU communication for port 1 in system block before dowload into PLC.
690 +
691 +(% style="text-align:center" %)
692 +[[image:ControlStarSystemBlock.png]]
693 +
694 +(% style="text-align:center" %)
695 +[[image:ControlStarCommunicate.png]]
696 +
697 +(% style="text-align:center" %)
698 +[[image:ControlStarModbus.png]]
699 +
700 +(% class="wikigeneratedid" %)
701 +**3)Address List**
702 +
703 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
704 +|(% colspan="1" rowspan="12" %)Bit|Y|YOOO|0~~377|
705 +|X|XOOO|0~~377|
706 +|M0|M0DDDD|0~~2047|
707 +|M1|M1DDDDD|2048~~10239|
708 +|SM0|SM0DDD|0~~255|
709 +|SM1|SM1DDD|256~~511|
710 +|S0|S0DDDD|0~~1023|
711 +|S1|S1DDDD|1024~~4095|
712 +|T0|T0DDD|0~~255|
713 +|T1|T1DDD|256~~511|
714 +|C0|C0DDD|0~~255|
715 +|C1|C1DDD|256~~306|
716 +|(% colspan="1" rowspan="7" %)Word|D|DDDDD|0~~7999|
717 +|Z|ZDD|0~~15|
718 +|TW0|TW0DDD|0~~255|
719 +|TW1|TW1DDD|256~~511|
720 +|SD0|SD0DDD|0~~255|
721 +|SD1|SD1DDD|256~~511|
722 +|CW|CWDDD|0~~306|
723 +|(% colspan="1" rowspan="2" %)Double Word|CW0|CW0DDD|200~~255|
724 +|CW1|CW1DDDDD|256~~99999|
725 +
726 +**4) Cable Wiring**
727 +
728 +(% style="text-align:center" %)
729 +[[image:Emerson.png]]
730 +
731 += Create communication with HollySys PLC =
732 +
733 +== **LK Modbus RTU** ==
734 +
735 +Supported Series: HollySys LK series PLC
736 +
737 +**1)V-BOX setting**
738 +
739 +|**Items**|**Settings**|**Note**
740 +|Protocol|HollySys LK Modbus RTU|
741 +|Connection|RS485|
742 +|Baud rate|38400|
743 +|Data bit|8|
744 +|Parity|None|
745 +|Stop bit|1|
746 +|Device station No.|1|
747 +
748 +**2)Address List**
749 +
750 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
751 +|Bit|QX|QXDDDDD.dd|0~~65535.15|
752 +|Bit|IX|IXDDDDD.dd|0~~65535.15|
753 +|Bit|MX|MXDDDDD.dd|0~~65535.15|
754 +|Word|QW|QWDDDDD|0~~99999|
755 +|Word|IW|IWDDDDD|0~~99999|
756 +|Word|MW|MWDDDDD|0~~99999|
757 +|Word|MD|MDDDDDD|0~~99999|
758 +
759 +**3)Cable Wiring**
760 +
761 +(% style="text-align:center" %)
762 +[[image:Hollysys485-2.png]]
763 +
662 662  = Create communication with **Siemens PLC** =
663 663  
664 664  == **S7-200 Smart Ethernet Protocol** ==
ControlStarCommunicate.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +26.0 KB
Content
ControlStarModbus.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content
ControlStarSystemBlock.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +46.3 KB
Content
Emerson.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
Hollysys485-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.5 KB
Content
Hollysys485box.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +13.4 KB
Content
V-NET_Client_TNBuqy7T5r.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +26.7 KB
Content