Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 231.1
edited by Theodore Xu
on 2023/04/23 15:42
Change comment: There is no comment for this version
To version 142.1
edited by Ben
on 2022/08/31 16:02
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.AiXia
1 +XWiki.Ben
Content
... ... @@ -176,116 +176,16 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 -= Create communication with Allen-Bradley(**Rockwell**)** PLC** =
179 += Create communication with **Rockwell PLC** =
180 180  
181 -== **DF1 Advanced Protocol** ==
181 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
182 182  
183 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5
184 -
185 -**1) V-Box Settings**
186 -
187 -|=Item|=Recommended |=Note
188 -|=Protocol|Allen Bradley DF1 Advanced|
189 -|=Connection|RS232|
190 -|=Baud rate|19200|
191 -|=Stop bits|1|
192 -|=Data bits|8|
193 -|=Parity|None|
194 -|=PLC Station No.|1|
195 -|=HMI Station No.|0|
196 -
197 -**2) Address List**
198 -
199 -|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note
200 -|(% colspan="1" rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1
201 -|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0
202 -|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2
203 -|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3
204 -|BN|BNddddd.dd|0.0~~99255.15|(((
205 -Bit data file B0~~B99
206 -
207 -First two digits is for file number
208 -
209 -For example, BN13001.00 represents file number B13, address 001, the 0th bit.
210 -)))
211 -|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7
212 -|NN|NNddddd.dd|0.0~~99255.15|(((
213 -Integer data file bit format N0~~N99
214 -
215 -First two digits is for file number
216 -
217 -For example, NN13001.00 represents file number N13, address 001, the 0th bit.
218 -)))
219 -|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2
220 -|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value)
221 -|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value)
222 -|TNS|TNSddddd|0~~99255|(((
223 -Timer Preset Value
224 -
225 -First two digits is for file number
226 -
227 -For example, TNS99255 represents file number T99, address 255.
228 -)))
229 -|TNP|TNPddddd|0~~99255|(((
230 -Timer Accumulator Value
231 -
232 -First two digits is for file number
233 -
234 -For example, TNP99255 represents file number T99, address 255.
235 -)))
236 -|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value)
237 -|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value)
238 -|CNS|CNSddddd|0~~99255|(((
239 -Counter Preset Value
240 -
241 -First two digits is for file number
242 -
243 -For example, CNS99255 represents file number C99, address 255.
244 -)))
245 -|CNP|CNPddddd|0~~99255|(((
246 -Counter Accumulator Value
247 -
248 -First two digits is for file number
249 -
250 -For example, CNP99255 represents file number C99, address 255.
251 -)))
252 -|N7|N7ddd|0~~255|Only able to communicate with file number N7
253 -|NN|NNddd|0~~99255|(((
254 -Integer data file
255 -
256 -First two digits is for file number
257 -
258 -For example, NN99255 represents file number N99, address 255.
259 -)))
260 -|(% colspan="1" rowspan="3" %)Double Word|F8|F8ddd|0~~255|(((
261 -Only able to communicate with file number N7
262 -)))
263 -|FN|FNddddd|0~~99255|(((
264 -Floating point data file
265 -
266 -First two digits is for file number
267 -
268 -For example, FN99255 represents file number F99, address 255.
269 -)))
270 -|LN|LNddddd|0~~99255|Long
271 -
272 -**3) Cable Wiring**
273 -
274 -(% style="text-align:center" %)
275 -[[image:ABRS232.gif]]
276 -
277 -(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %)
278 -(% id="cke_bm_5621S" style="display:none" %)** **
279 -
280 -== **MicroLogix Protocol** ==
281 -
282 -(% class="wikigeneratedid" %)
283 283  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
284 284  
285 -**1)V-BOX setting**
185 +**1)PLC Settings**
286 286  
287 287  |**Item**|**Settings**|**Note**
288 -|Protocol|Allen-Bradley DF1 Advanced|
188 +|Protocol|Allen-Bradlley DF1 Advanced|
289 289  |Connection|RS232|
290 290  |Baud rate|19200|
291 291  |Data bit|8|
... ... @@ -520,147 +520,11 @@
520 520  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
521 521  
522 522  
523 -= **Micro850_FreeTag Protocol(new)** =
423 +== **Allen-Bradley Ethernet DF1** ==
524 524  
525 -This example introduces the establishment of Ethernet communication between Wecon V-box and 2080-LC50-48QWB,Micro850. It is introduced through three parts: PLC software configuration, V-box software configuration.
526 -
527 -(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
528 -(((
529 -**Software configuration of PLC**
530 -)))
531 -
532 -(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %)
533 -(((
534 -**1)PLC programming software:Connected Components Workbench™**
535 -
536 -(% style="text-align:center" %)
537 -[[image:software.png]]
538 -
539 -**2)New PLC project**
540 -
541 -Click New Project and select the PLC model.
542 -
543 -(% style="text-align:center" %)
544 -[[image:project create.png]]
545 -
546 -**3)Set Ethernet parameters**
547 -
548 -Follow the steps below to configure Ethernet parameters
549 -
550 -PLC IP address:192.168.39.56
551 -
552 -default gateway:192.168.39.1
553 -
554 -subnet mask:255.255.255.0
555 -
556 -(% style="text-align:center" %)
557 -[[image:Ethernet.png]]
558 -
559 -**4)connect PLC**
560 -
561 -**When downloading the setting, need to change the status of the PLC to PRG**
562 -
563 -(% style="text-align:center" %)
564 -[[image:conne ab plc.png]]
565 -
566 -**V-box software configuration**
567 -
568 -**1)V-box programming software**
569 -
570 -(% style="text-align:center" %)
571 -[[image:v-net client vers.png]]
572 -
573 -**2)Set communication port parameters**
574 -
575 -In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
576 -
577 -(% style="text-align:center" %)
578 -[[image:V-NET_Client_t2Rg2wpSoY.png]]
579 -
580 -The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
581 -
582 -(% style="text-align:center" %)
583 -[[image:V-NET_Client_communication.png]]
584 -
585 -Export variables from PLC, select CSV file, comma delimited. After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png"]]icon add label.
586 -
587 -(% style="text-align:center" %)
588 -[[image:export1.png]]
589 -
590 -(% style="text-align:center" %)
591 -[[image:CCW.Shell_E5Cwj4tUL3.png]]
592 -
593 -(% style="text-align:center" %)
594 -[[image:V-NET_Client_iKKKhcgxm1.png]]
595 -
596 -**3)Engineering production**
597 -
598 -According to your own needs, use the V-NET client software to edit the required data monitoring points.
599 -
600 -(% style="text-align:center" %)
601 -[[image:V-NET_Client_KOR0AHEA4M.png]]
602 -
603 -
604 -)))
605 -
606 -== **Ethernet DF1 Protocol** ==
607 -
608 608  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
609 609  
610 -= Create communication with **Crouzet PLC** =
611 611  
612 -== **CROUZET M3 (FBD)** ==
613 -
614 -Support Series: Crouzet Millenium 3 CD12/CB12
615 -
616 -**1)V-BOX setting**
617 -
618 -|=Item|=Recommended |=Note
619 -|=Protocol|CROUZET M3 (FBD)|
620 -|=Connection|RS232|
621 -|=Baud rate|115200|
622 -|=Stop bits|1|
623 -|=Data bits|7|
624 -|=Parity|EVEN|
625 -
626 -**2)Address List**
627 -
628 -|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note
629 -|(% rowspan="4" %)Bit|I|I DD|1~~99|Input
630 -|SLIBit|SLIBit DD.dd|1.0~~24.15|Serial Link Input
631 -|SLOBit|SLOBit DD.dd|25.0~~48.15|Serial Link Output(Read only)
632 -|State|State D|1~~1|PLC state(Read only)
633 -|(% rowspan="5" %)Word|AI|AI DD|1~~99|Analog Input
634 -|SLIn|SLIn DD|1~~24|Serial Link Input
635 -|SLOut|SLOut DD|25~~48|Serial Link Output(Read only)
636 -|Time|Time D|1~~6|(((
637 -Time1: Second
638 -
639 -Time2: Minute
640 -
641 -Time3: Hour
642 -
643 -Time4: Day
644 -
645 -Time5: Month
646 -
647 -Time6: Year
648 -)))
649 -|Order|Order D|1~~1|(((
650 -Running command(Write only)
651 -
652 -~=2: Run mode; =1: Stop mode;
653 -)))
654 -
655 -**3)Cable Wiring**
656 -
657 -(% style="text-align:center" %)
658 -[[image:CrouzetRS232 VBox.png]]
659 -
660 -{{info}}
661 -**✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details.
662 -{{/info}}
663 -
664 664  = Create communication with **Siemens PLC** =
665 665  
666 666  == **S7-200 Smart Ethernet Protocol** ==
... ... @@ -672,7 +672,7 @@
672 672  
673 673  Supported Series: Siemens S7-300 series PLC
674 674  
675 -**1)V-BOX setting**
439 +**1)PLC Setting**
676 676  
677 677  |**Items**|**Settings**|**Note**
678 678  |Protocol|Simens S7-300 Ethernet|
... ... @@ -734,7 +734,7 @@
734 734  
735 735  Supported Series: Siemens S7-400, S7-1200 and S7-1500
736 736  
737 -**1)V-BOX setting**
501 +**1)PLC Setting**
738 738  
739 739  |=**Items**|=**Settings**|=**Note**
740 740  |Protocol|Siemens S7-XXX|
... ... @@ -844,97 +844,6 @@
844 844  
845 845  [[image:image-20220824162342-2.png]]
846 846  
847 -== **LOGO Ethernet Protocol** ==
848 -
849 -Supported Series: Siemens Logo 0BA0, 0BA1 series
850 -
851 -**V-BOX Settings**
852 -
853 -
854 -|**Items**|**Settings**|**Note**
855 -|Protocol|Siemens LOGO|
856 -|Connection|Ethernet|
857 -|Port No.|102|
858 -|PLC station No.|2|
859 -
860 -**Address List**
861 -
862 -
863 -|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
864 -|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
865 -|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
866 -|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
867 -|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
868 -|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
869 -|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
870 -|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
871 -|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
872 -|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
873 -|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
874 -|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
875 -|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
876 -|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
877 -|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
878 -|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
879 -
880 -**PLC Settings in LOGO Software:**
881 -
882 -Click [Tools]~-~-[Ethernet Connections],shown as below.
883 -
884 -(% style="text-align:center" %)
885 -[[image:PIStudio.12\.PLC protocols.WebHome@12.PLC Protocol_html_8b9d2322edf89519.png]]
886 -
887 -Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
888 -
889 -(% style="text-align:center" %)
890 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228142937-4.png]]
891 -
892 -**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
893 -
894 -(% style="text-align:center" %)
895 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143047-5.png]]
896 -
897 - **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
898 -
899 -(% style="text-align:center" %)
900 -[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143246-6.png]]
901 -
902 -**V-BOX Communication Settings**
903 -
904 -Set PLC IP in [IP Address] settings;
905 -
906 -(% style="text-align:center" %)
907 -[[image:LldwDGntf4.png]]
908 -
909 -Enable V-BOX Ethernet in [Network];
910 -
911 -(% style="text-align:center" %)
912 -[[image:WgvjfWbQif.png]]
913 -
914 -TSAP setting
915 -
916 -* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful.
917 -
918 -{{code language="LUA"}}
919 -function init.main()
920 -addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
921 -addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
922 -end
923 -{{/code}}
924 -
925 -Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code.
926 -
927 -**✎Note:**
928 -
929 -* **Communication port configuration: **
930 -** Continuous length needs to be set to 0.
931 -** Integration interval needs to be set to 1. (no change may result in data errors)
932 -** Set Port and Device Station NO.
933 -** Other set as defaulted.
934 -* **Notes on the use of registers:**
935 -** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
936 -** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
937 -
938 938  = Create communication with **Mitsubishi PLC** =
939 939  
940 940  == **FX1S,1N,2N Serial Protocol** ==
... ... @@ -1031,101 +1031,6 @@
1031 1031  [[image:image-20220825100845-4.png]]
1032 1032  
1033 1033  
1034 -== **FX3U Ethernet Protocol** ==
1035 -
1036 -Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
1037 -
1038 -**1)V-BOX Settings**
1039 -
1040 -|Items|Settings|Note
1041 -|Protocol|Mitsubishi FX3U|
1042 -|Connection|Ethernet|
1043 -|Port No.|5009|Must be the same as the PLC setting
1044 -|PLC station No.|0|
1045 -
1046 -**2)Address List**
1047 -
1048 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1049 -|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377|
1050 -|Y|Y|Y OOO|0~~377|
1051 -|M|M|M DDDD|0~~7679|
1052 -|SM|SM|SM DDDD|8000~~8511|
1053 -|S|S|S DDDD|0~~4095|
1054 -|TS|TS|TS DDD|0~~511|
1055 -|CS|CS|CS DDD|0~~255|
1056 -|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199|
1057 -|TN|TN|TN DDD|0~~511|
1058 -|D|D|D DDDD|0~~7999|
1059 -|SD|SD|SD DDDD|8000~~8511|
1060 -|R|R|R DDDDD|0~~32767|
1061 -
1062 -**3)Ethernet Module Settings**
1063 -
1064 -FX3U-ENET-L module configuration
1065 -Set up the FX3U-ENET-L Ethernet module settings as follows.
1066 -Select the module location, which in this document is Module 0.
1067 -
1068 -[[image:image-20221116105850-1.png]]
1069 -
1070 -Select "Operational setting" to enter the following screen.
1071 -
1072 -The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
1073 -
1074 -[[image:image-20221116105947-1.png]]
1075 -
1076 -Select "Open setting" to enter the setting interface, the settings are as follows.
1077 -
1078 -The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
1079 -
1080 -Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
1081 -
1082 -[[image:image-20221116110802-1.png]]
1083 -
1084 -Click on "transter setup" - "PC side I/F setting", see the following figure.
1085 -
1086 -After setting, the first download must use the programming cable, as shown in the figure; after that, can
1087 -
1088 -use the IP set in the "Ethernet board" to communicate directly with the network cable.
1089 -
1090 -[[image:image-20221116110832-2.png||height="423" width="708"]]
1091 -
1092 -Read and write data from the Ethernet module
1093 -
1094 -[[image:image-20221116110907-3.png]]
1095 -
1096 -Set "Transter setup" to COM communication, and read or write operation as shown below
1097 -
1098 -[[image:image-20221116110917-4.png]]
1099 -
1100 -**4)PLC Settings (GX Works 2)**
1101 -
1102 -Create a blank FX5U project
1103 -
1104 -Find Current Connection in the navigation
1105 -
1106 -[[image:image-20221116111427-1.png||height="421" width="705"]]
1107 -
1108 -Select Connection Channel List
1109 -
1110 -Select Ethernet board communication
1111 -
1112 -[[image:image-20221116111451-2.png||height="421" width="705"]]
1113 -
1114 -Select Ethernet Module
1115 -Set the IP address of the PLC
1116 -
1117 -[[image:image-20221116111509-3.png||height="666" width="699"]]
1118 -
1119 -Read or write PLC data, in this document is read
1120 -
1121 -[[image:image-20221116111651-4.png||height="416" width="697"]]
1122 -
1123 -[[image:image-20221116111727-5.png||height="416" width="697"]]
1124 -
1125 -**4)Configure the communication protocol**
1126 -
1127 -[[image:image-20221119101946-2.png||height="395" width="695"]]
1128 -
1129 1129  == **FX5U Serial Protocol** ==
1130 1130  
1131 1131  Mitsubishi FX5U series PLC
... ... @@ -1280,10 +1280,11 @@
1280 1280  
1281 1281  [[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]]
1282 1282  
1283 -**5)Cable Wiring**
861 +**5)电缆布线**
1284 1284  
1285 1285  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1286 1286  
865 +
1287 1287  == **L02 Serial Protocol** ==
1288 1288  
1289 1289  Mitsubishi L02 series CPU built-in serial port.
... ... @@ -1417,12 +1417,6 @@
1417 1417  
1418 1418  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1419 1419  
1420 -== **Q12H Serial Protocol** ==
1421 -
1422 -This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
1423 -
1424 -[[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]
1425 -
1426 1426  == **QJ71E71 Ethernet Protocol** ==
1427 1427  
1428 1428  Mitsubishi QJ71E71 Ethernet communication module;
... ... @@ -1471,13 +1471,10 @@
1471 1471  
1472 1472  * Click [Ethernet/CC IE/MELSECNET];
1473 1473  * Please select [Ethernet] as network type;
1474 -* Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
1047 +* Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order);
1475 1475  * Select [Online] as Mode;
1476 -* [[image:image-20221119171343-2.png||height="341" width="587"]]
1477 1477  * Click [Operation setting] to set IP;
1478 1478  * Select [Binary Code] as [Communication Data Code];
1479 -* [[image:image-20221119171436-3.png||height="354" width="588"]]
1480 -* Click [Open setting]
1481 1481  * Set protocol: TCP;
1482 1482  * Set [unpassive] in [Open system];
1483 1483  * Set [receive] in [Fixed buffer];
... ... @@ -1484,16 +1484,14 @@
1484 1484  * Set [procedure Exist] in [Fixed buffer communication];
1485 1485  * Disable [Pairing open];
1486 1486  * Set [No confirm] in [Existence confirmation];
1487 -* Host station port number: 5009;
1057 +* Host station port number: 1025;
1488 1488  * Save settings;
1489 -* [[image:image-20221119171611-4.png||height="354" width="588"]]
1490 1490  * Download project into PLC and restart it
1491 1491  
1492 1492  **4)Configure the communication protocol**
1493 1493  
1494 -[[image:image-20221119171832-5.png||height="354" width="625"]]
1063 +[[image:image-20220825143728-1.png]]
1495 1495  
1496 -
1497 1497  **5)Cable Wiring**
1498 1498  
1499 1499  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
... ... @@ -1502,105 +1502,12 @@
1502 1502  
1503 1503  == **DVP Ethernet Protocol** ==
1504 1504  
1505 -Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module
1073 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1506 1506  
1507 -**1)V-BOX Settings**
1508 -
1509 -|=**Items**|=**Settings**|=**Note**
1510 -|Protocol|DELTA DVP MODBUS TCP|
1511 -|Connection|Ethernet|
1512 -|Port No.|502|
1513 -|Device No.|1|
1514 -|VBox Device No.|0|
1515 -
1516 -**2)Address List **
1517 -
1518 -|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note**
1519 -|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOO|(% style="width:225px" %)0~~377|
1520 -|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOO|(% style="width:225px" %)0~~377|
1521 -|Bit|(% style="width:191px" %)M0|(% style="width:217px" %)M0|(% style="width:168px" %)M0DDDD|(% style="width:225px" %)0~~1535|
1522 -|Bit|(% style="width:191px" %)M1|(% style="width:217px" %)M1|(% style="width:168px" %)M1DDDD|(% style="width:225px" %)1536~~4096|
1523 -|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255|
1524 -|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~255|
1525 -|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDD|(% style="width:225px" %)0~~1023|
1526 -|Word|(% style="width:191px" %)D0|(% style="width:217px" %)D0|(% style="width:168px" %)D0DDDD|(% style="width:225px" %)0~~4095|
1527 -|Word|(% style="width:191px" %)D1|(% style="width:217px" %)D1|(% style="width:168px" %)D1DDDD|(% style="width:225px" %)4096~~11999|
1528 -|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255|
1529 -|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199|
1530 -|Double Word|(% style="width:191px" %)HC|(% style="width:217px" %)HC|(% style="width:168px" %)HCDDD|(% style="width:225px" %)200~~255|
1531 -
1532 -**3) PLC Setting:**
1533 -
1534 -~1. Create new project in Delta WPL Soft, and click Setting to open the communication settings:
1535 -
1536 -(% style="text-align:center" %)
1537 -[[image:DVPEthernetWPLSoft2.png]]
1538 -
1539 -2. Set up the communication type and PLC IP:
1540 -
1541 -(% style="text-align:center" %)
1542 -[[image:DVPEthernetSetup.png]]
1543 -
1544 -(% class="wikigeneratedid" %)
1545 -3. Click OK and save the settings. Then click Communication on toolbar, then click Transfer Setup to open new window:
1546 -
1547 -(% style="text-align:center" %)
1548 -[[image:DVPEthernetTransfer.png]]
1549 -
1550 -(% class="wikigeneratedid" %)
1551 -4. Select Communication Mode as PC => PLC to download or select PC <=PLC to upload:
1552 -
1553 -(% style="text-align:center" %)
1554 -[[image:DVPEthernetPLCtoPC.png]]
1555 -
1556 -5. Click Auto-Search Ethernet Module to find the PLC on the same LAN network:
1557 -
1558 -(% style="text-align:center" %)
1559 -[[image:DVPEthernetAutoSearch.png]]
1560 -
1561 -**4) V-BOX Setting:**
1562 -
1563 -Set the same IP address according to the setting from WPL Soft:
1564 -
1565 -(% style="text-align:center" %)
1566 -[[image:DVPEthernetVNETPortocol.png]]
1567 -
1568 1568  == **DVP serial protocol** ==
1569 1569  
1570 -Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX
1077 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1571 1571  
1572 -**1)V-BOX Settings**
1573 -
1574 -|=**Items**|=**Settings**|=**Note**
1575 -|Protocol|DELTA DVP PROTOCOL|
1576 -|Connection|RS232|
1577 -|Baud Rate|9600|
1578 -|Stop Bit|1|
1579 -|Data Bit|7|
1580 -|Parity|EVEN|
1581 -|Device No.|1|
1582 -
1583 -(% class="wikigeneratedid" %)
1584 -**2)Address List**
1585 -
1586 -|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note**
1587 -|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOOOOO|(% style="width:225px" %)0~~303237|
1588 -|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOOOOO|(% style="width:225px" %)0~~303237|
1589 -|Bit|(% style="width:191px" %)M|(% style="width:217px" %)M|(% style="width:168px" %)MDDDDD|(% style="width:225px" %)0~~99999|
1590 -|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999|
1591 -|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)0~~99999|
1592 -|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDDD|(% style="width:225px" %)0~~99999|
1593 -|Word|(% style="width:191px" %)D|(% style="width:217px" %)D|(% style="width:168px" %)D DDDDD|(% style="width:225px" %)0~~99999|
1594 -|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999|
1595 -|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199|
1596 -|Double Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)200~~99999|
1597 -
1598 -(% class="wikigeneratedid" %)
1599 -**3)Wiring Diagram**
1600 -
1601 -(% style="text-align:center" %)
1602 -[[image:Delta DVP PROTOCOLSerial232.png]]
1603 -
1604 1604  == **AS Ethernet Protocol** ==
1605 1605  
1606 1606  **1)V-BOX Settings**
... ... @@ -1632,8 +1632,10 @@
1632 1632  |Word|C|C|C h|0~~511|
1633 1633  |Word|E|E|E d|0~~9|
1634 1634  
1110 +
1635 1635  **3)Configure the communication protocol**
1636 1636  
1113 +
1637 1637  [[image:image-20220831160010-4.png]]
1638 1638  
1639 1639  **4)Cable Wiring**
... ... @@ -1656,423 +1656,10 @@
1656 1656  
1657 1657  [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1658 1658  
1136 += Create communication with **Modbus RTU** =
1659 1659  
1660 -== **EC55 Series Protocol** ==
1138 +== **V-BOX as Slave** ==
1661 1661  
1662 -Supported device: EC55 temperature instrument
1663 -
1664 -**1)V-BOX Settings**
1665 -
1666 -|**Items**|**Settings**|**Note**
1667 -|Protocol|Omron EC55|
1668 -|Connection|RS485 (9600, 2, 7, EVEN)|
1669 -|Port No.|None|
1670 -|PLC station No.|0|
1671 -
1672 -**2)Address List**
1673 -
1674 -|**Type**|**Register**|**Device range**|**HMI range**|**Function**
1675 -|(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0
1676 -|C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0
1677 -|C3|0-CD(Hex)|0-205|Set Read/Write parameter for area 1
1678 -|(% rowspan="6" %)Word|80|0-13(Hex)|0-19|Set read only parameter in area 0
1679 -|81|0-4D(Hex)|0-77|Set Read/Write parameter in area 0
1680 -|83|0-CD(Hex)|0-205|Set Read/Write parameter in area 1
1681 -|CP|-|0-6|Read controller intrinsic property
1682 -|CS|-|0-2|Read controller states
1683 -|CA|-|0-17|Action command
1684 -
1685 -**3)Device Settings**
1686 -
1687 -Omron E5CC PLC configuration
1688 -
1689 -After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting.
1690 -
1691 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_3d95e093792ba98a.png?width=550&height=229&rev=1.1||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]]
1692 -
1693 -According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows
1694 -
1695 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_be583aa69dd6cf4c.png?width=550&height=242&rev=1.1||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]]
1696 -
1697 -**✎Note:** The communication settings for HMI should be consistent with this setting.
1698 -
1699 -**4)Configure the communication protocol**
1700 -
1701 -[[image:image-20220831161041-1.png]]
1702 -
1703 -**5)Cable Wiring**
1704 -
1705 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1706 -
1707 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1708 -
1709 -**✎Note:**
1710 -
1711 -* COM3 only available in PI8000/PI9000 series.
1712 -* CA address could not support continuous writing function;
1713 -* Because of CP address intrinsic property: read control intrinsic property, so please place the character input part in use. Set address with CP0 and character length 10, used to display controller type. And place a number input part, set address with CP5 (cache size). Do not place other CP type address without CP0 in screen, otherwise CP type address is invalid
1714 -* When set value into read & write address, it is necessary to switch the temperature instrument meter to the corresponding interface according to the menu of the instrument where the address locates, so that the value could be written, otherwise, the value could not be written; When the communication write setting of the instrument is turned off, the writing function is invalid. Writing function could be opened by using the 00 address of the CA register, which write 01 value.
1715 -* When continuous writing of a value to a read-write address, please make sure all continuous writing address could be written. Otherwise, if one of these addresses could not be written, then all continuous writing commands will fail.
1716 -* Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document.
1717 -* When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable.
1718 -* Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1719 -* [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1720 -
1721 -= Create communication with Xinje** PLC** =
1722 -
1723 -== **XC serial protocol** ==
1724 -
1725 -**1)V-BOX Settings**
1726 -
1727 -|**Item**|**Settings**|**Note**
1728 -|Protocol|XINJE XC MODBUS|
1729 -|Connection|RS232|
1730 -|Baud rate|19200|
1731 -|Data bit|8|
1732 -|Parity|EVEN|
1733 -|Stop bit|1|
1734 -|PLC station No.|1|
1735 -
1736 -**2)Address List**
1737 -
1738 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1739 -|Bit|M|M|M d|0~~8511|
1740 -|Bit|X|X|X o|0~~1747|
1741 -|Bit|Y|Y|Y o|0~~1747|
1742 -|Bit|S|S|S d|0~~1023|
1743 -|Bit|T|T|T d|0~~4095|
1744 -|Bit|C|C|C d|0~~634|
1745 -|Word|D|D|D d|0~~8511|
1746 -|Word|TD|TD|TD d|0~~618|
1747 -|Word|CD|CD|CD d|0~~634|
1748 -|Word|FD|FD|FD d|0~~8511|
1749 -
1750 -**3)Configure the communication protocol**
1751 -
1752 -
1753 -[[image:image-20220831163041-1.png]]
1754 -
1755 -**4)Cable Wiring**
1756 -
1757 -Figure
1758 -
1759 -[[image:image-20220831163406-2.png]][[image:image-20220831163422-3.png]]
1760 -
1761 -Pin Definition Diagram
1762 -
1763 -[[image:image-20220831163441-4.png]]
1764 -
1765 -== **XD serial protocol** ==
1766 -
1767 -**1)V-BOX Settings**
1768 -
1769 -Supported Series: Xinjie XD/XE Series PLC
1770 -
1771 -|**Item**|**Settings**|**Note**
1772 -|Protocol|XINJE XD/XC MODBUS|
1773 -|Connection|RS232|
1774 -|Baud rate|19200|
1775 -|Data bit|8|
1776 -|Parity|EVEN|
1777 -|Stop bit|1|
1778 -|PLC station No.|1|
1779 -
1780 -**2)Address List**
1781 -
1782 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1783 -|Bit|M|M|M d|0~~74999|
1784 -|Bit|X1xx|X1xx|X1xx o|0~~1177|
1785 -|Bit|X2xx|X2xx|X2xx o|0~~277|
1786 -|Bit|X|X|X o|0~~77|
1787 -|Bit|Y1xx|Y1xx|Y1xx o|0~~1177|
1788 -|Bit|Y2xx|Y2xx|Y2xx o|0~~277|
1789 -|Bit|Y|Y|Y o|0~~4095|
1790 -|Bit|SM|SM|SM d|0~~4999|(((
1791 -
1792 -)))
1793 -|Bit|T|T|T d|0~~4999|
1794 -|Bit|C|C|C d|0~~4999|
1795 -|Bit|ET|ET|ET d|0~~31|
1796 -|Bit|SE|SE|SE d|0~~31|
1797 -|Bit|HM|HM|HM d|0~~11999|
1798 -|Bit|HSC|HSC|HSC d|0~~39|
1799 -|Bit|HS|HS|HS d|0~~999|
1800 -|Bit|HT|HT|HT d|0~~1999|
1801 -|Bit|HC|HC|HC d|0~~1999|
1802 -|Bit|S|S|S d|0~~7999|
1803 -|Word|D|D|D d|0~~69999|
1804 -|Word|ID|ID|ID d|0~~99|
1805 -|Word|ID1xx|ID1xx|ID1xx d|0~~999|
1806 -|Word|ID2xx|ID2xx|ID2xx d|0~~299|
1807 -|Word|QD|QD|QD d|0~~99|
1808 -|Word|QD1xx|QD1xx|QD1xx d|0~~999|
1809 -|Word|QD2xx|QD2xx|QD2xx d|0~~299|
1810 -|Word|SD|SD|SD d|0~~4999|
1811 -|Word|TD|TD|TD d|0~~575|
1812 -|Word|CD|CD|CD d|0~~575|
1813 -|Word|ETD|ETD|ETD d|0~~31|
1814 -|Word|HD|HD|HD d|0~~24999|
1815 -|Word|HSD|HSD|HSD d|0~~1023|
1816 -|Word|HTD|HTD|HTD d|0~~95|
1817 -|Word|HCD|HCD|HCD d|0~~95|
1818 -|Word|HSCD|HSCD|HSCD d|0~~31|
1819 -|Word|FD|FD|FD d|0~~8191|
1820 -|Word|SFD|SFD|SFD d|0~~5999|
1821 -|Word|FS|FS|FS d|0~~47|
1822 -
1823 -**3)Configure the communication protocol**
1824 -
1825 -[[image:image-20220831163923-7.png]]
1826 -
1827 -
1828 -
1829 -**4)Cable Wiring**
1830 -
1831 -Figure
1832 -
1833 -[[image:image-20220831163406-2.png]][[image:image-20220831163553-6.png]]
1834 -
1835 -Pin Definition Diagram
1836 -
1837 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1838 -
1839 -= Create communication with **Schneider PLC** =
1840 -
1841 -== **Schneider MODBUS RTU** ==
1842 -
1843 -**1)V-BOX Setting**
1844 -
1845 -|=**Parameters**|=**Recommended**|=**Notes**
1846 -|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU|
1847 -|**Connection**|RS485|
1848 -|**Baud rate**|19200|
1849 -|**Data bit**|8|
1850 -|**Parity**|Even|
1851 -|**Stop bit**|1|
1852 -|**PLC station No.**|1|
1853 -
1854 -**2)Address List**
1855 -
1856 -|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
1857 -|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only)
1858 -|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils
1859 -|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal)
1860 -|W|MW|DDDDDD|0 ~~ 999999|Output register
1861 -|DW|MD|DDDDDD|0 ~~ 999999|Output register
1862 -
1863 -**3)Configure the communication protocol**
1864 -
1865 -[[image:image-20220902104329-1.png]]
1866 -
1867 -**4)Cable Wiring**
1868 -
1869 -**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector.
1870 -
1871 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
1872 -
1873 -= Create communication with Inovance** PLC** =
1874 -
1875 -== **H3U serial protocol** ==
1876 -
1877 -**1)V-BOX Settings**
1878 -
1879 -|**Item**|**Settings**|**Note**
1880 -|Protocol|INOVANCE H3U PLC|
1881 -|Connection|RS422|
1882 -|Baud rate|9600|
1883 -|Data bit|7|
1884 -|Parity|EVEN|
1885 -|Stop bit|1|
1886 -|PLC station No.|0|
1887 -
1888 -**2)Address List**
1889 -
1890 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1891 -|Bit|X|X|X o|0~~303237|
1892 -|Bit|Y|Y|Y o|0~~303237|
1893 -|Bit|M|M|M d|0~~99999|
1894 -|Bit|T|T|T d|0~~99999|
1895 -|Bit|C|C|C d|0~~99999|
1896 -|Bit|SM|SM|SM d|8000~~999|
1897 -|Bit|S|T|S d|0~~99999|
1898 -|Bit|Lamp|Lamp|Lamp d|0~~0|
1899 -|Word|X|X|X o|0~~303237|
1900 -|Word|Y|Y|Y o|0~~303237|
1901 -|Word|M|M|M d|0~~99999|
1902 -|Word|T|T|T d|0~~99999|
1903 -|Word|C|C|C d|0~~199|
1904 -|Word|D|D|D d|0~~7999|
1905 -|Word|S|S|S d|0~~99999|
1906 -|Word|SD|SD|SD d|8000~~9999|
1907 -|Word|R|R|R d|0~~32767|
1908 -
1909 -**3)Configure the communication protocol**
1910 -
1911 -[[image:image-20220831164626-1.png]]
1912 -
1913 -
1914 -
1915 -**4)Cable Wiring**
1916 -
1917 -Figure
1918 -
1919 -[[image:image-20220831164646-2.png]][[image:image-20220831164700-3.png]]
1920 -
1921 -Pin Definition Diagram
1922 -
1923 -[[image:image-20220831164731-4.png]]
1924 -
1925 -= Create communication with Panasonic** PLC** =
1926 -
1927 -== **FP serial protocol** ==
1928 -
1929 -**1)V-BOX Settings**
1930 -
1931 -|**Item**|**Settings**|**Note**
1932 -|Protocol|Panasonic FP MFWTOCOL|
1933 -|Connection|RS232|
1934 -|Baud rate|9600|
1935 -|Data bit|8|
1936 -|Parity|ODD|
1937 -|Stop bit|1|
1938 -|PLC station No.|1|
1939 -
1940 -**2)Address List**
1941 -
1942 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1943 -|Bit|X|X|X d|0~~9999|
1944 -|Bit|Y|Y|Y d|0~~9999|
1945 -|Bit|R|R|R d|0~~9999|
1946 -|Bit|T|T|T d|0~~9999|
1947 -|Bit|C|C|C d|0~~9999|
1948 -|Bit|L|L|L d|0~~9999|
1949 -|Word|WX|WX|WX d|0~~9999|
1950 -|Word|WY|WY|WY d|0~~9999|
1951 -|Word|WR|WR|WR d|0~~9999|
1952 -|Word|WL|WL|WL d|0~~9999|
1953 -|Word|LD|LD|LD d|0~~9999|
1954 -|Word|DT|DT|DT d|0~~65535|
1955 -|Word|FL|FL|FL d|0~~9999|
1956 -|Word|EV|EV|EV d|0~~9999|
1957 -|Word|SV|SV|SV d|0~~9999|
1958 -
1959 -**3)Configure the communication protocol**
1960 -
1961 -[[image:image-20220831165238-4.png]]
1962 -
1963 -
1964 -
1965 -**4)Cable Wiring**
1966 -
1967 -Figure
1968 -
1969 -[[image:image-20220831165031-3.png]][[image:image-20220831165017-2.png]]
1970 -
1971 -Pin Definition Diagram
1972 -
1973 -[[image:image-20220831165008-1.png]]
1974 -
1975 -= Create communication with LS** PLC** =
1976 -
1977 -== **XBC serial protocol** ==
1978 -
1979 -**1)V-BOX Settings**
1980 -
1981 -|**Item**|**Settings**|**Note**
1982 -|Protocol|LS XBC CNet|
1983 -|Connection|RS232|
1984 -|Baud rate|115200|
1985 -|Data bit|8|
1986 -|Parity|NONE|
1987 -|Stop bit|1|
1988 -|PLC station No.|1|
1989 -
1990 -**2)Address List**
1991 -
1992 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1993 -|Bit|P|P|P d|0~~2047|
1994 -|Bit|M|M|M d|0~~2047|
1995 -|Bit|L|L|L d|0~~11263|
1996 -|Bit|K|K|K d|0~~16183|
1997 -|Bit|F|F|F d|0~~2047|
1998 -|Bit|D|D|D d|0~~32767|
1999 -|Bit|R|R|R d|0~~32767|
2000 -|Bit|U|U|U d|0~~4095|
2001 -|Word|P|P|P d|0~~2047|
2002 -|Word|M|M|M d|0~~2047|
2003 -|Word|L|L|L d|0~~11263|
2004 -|Word|K|K|K d|0~~16183|
2005 -|Word|F|F|F d|0~~2047|
2006 -|Word|C|C|C d|0~~2047|
2007 -|Word|T|T|T d|0~~2047|
2008 -|Word|D|D|D d|0~~32767|
2009 -|Word|N|N|N d|0~~21503|
2010 -|Word|R|R|R d|0~~32767|
2011 -|Word|U|U|U d|0~~4095|
2012 -|Word|Z|Z|Z d|0~~127|
2013 -|Word|S|S|S d|0~~127|
2014 -
2015 -**3)Configure the communication protocol**
2016 -
2017 -[[image:image-20220831170147-1.png]]
2018 -
2019 -**4)Cable Wiring**
2020 -
2021 -Figure
2022 -
2023 -[[image:image-20220831170306-4.png]][[image:image-20220831170254-3.png]]
2024 -
2025 -Pin Definition Diagram
2026 -
2027 -[[image:image-20220831170215-2.png]]
2028 -
2029 -== **XGK FEnet Ethernet protocol** ==
2030 -
2031 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
2032 -
2033 -**1)V-BOX Settings**
2034 -
2035 -|**Items**|**Settings**|**Note**
2036 -|Protocol|LG XGK FEnet(Ethernet)|
2037 -|Connection|Ethernet|
2038 -|Port No.|2004|
2039 -
2040 -**2)Address List**
2041 -
2042 -|**Type**|**Register**|**Range**|**Format**|**Note**
2043 -|(% rowspan="14" %)Word|P|0~~2047|P d|
2044 -|M|0~~2047|M d|
2045 -|K|0~~2047|K d|
2046 -|F|0~~2047|F d|
2047 -|T|0~~2047|T d|
2048 -|C|0~~2047|C d|
2049 -|Z|0~~127|Z d|
2050 -|S|0~~127|S d|
2051 -|L|0~~11263|L d|
2052 -|N|0~~21503|N d|
2053 -|D|0~~32767|D d|
2054 -|R|0~~32767|R d|
2055 -|ZR|0~~65535|ZR d|
2056 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
2057 -
2058 -**✎Note:**
2059 -
2060 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
2061 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
2062 -* All bit registers are in the form of bits in word, and the range is the same as the word register;
2063 -
2064 -**3)Communication Settings**
2065 -
2066 -[[image:image-20220831171127-1.png]]
2067 -
2068 -**4)Cable Wiring**
2069 -
2070 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
2071 -
2072 -= Create communication with **Modbus ** =
2073 -
2074 -== **MODBUS RTU Slave (All function)** ==
2075 -
2076 2076  Select the protocol "Modbus RTU Slave (All Fuction)",
2077 2077  
2078 2078  Then set baud rate, port, stop bits, data bits, parity.
... ... @@ -2080,88 +2080,8 @@
2080 2080  (% style="text-align:center" %)
2081 2081  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
2082 2082  
2083 -== **Communicate with Modbus Meter** ==
1147 +== **V-BOX as Master** ==
2084 2084  
2085 -The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication.
2086 -
2087 -~1. Wiring the RS485 cable first. Because the pin 58 is A, the pin 59 is B for meter. Here we use the COM1 to connect. So the diagram like follows:
2088 -
2089 -(% style="text-align:center" %)
2090 -[[image:LinfeeTerminalDiagram.png]]
2091 -
2092 -2. Check the specific Modbus parameter in the communication menu from LED display.
2093 -
2094 -So from the following pictures, we can know the Meter Address is 85, Baud rate is 9600, CRC None.
2095 -
2096 -{{info}}
2097 -**✎Note: **Meter address usually corresponding to the Modbus Slave Station No. on the Modbus communication.
2098 -{{/info}}
2099 -
2100 -(% style="text-align:center" %)
2101 -[[image:MeterModbusAllView.png]]
2102 -
2103 -(% class="wikigeneratedid" %)
2104 -3. Set up the communication in the Configuration tab.
2105 -
2106 -(% class="wikigeneratedid" %)
2107 -Select the protocol as **ModBus RTU Slave (All Function)**. And set the communication parameters like below.
2108 -
2109 -(% style="text-align:center" %)
2110 -[[image:VNETCommunicationtabmeter.png]]
2111 -
2112 -(% class="wikigeneratedid" %)
2113 -4. Create new real-time monitoring tag accroding to Modbus manual
2114 -
2115 -(% class="wikigeneratedid" %)
2116 -Enter the address we want to read from the meter. The following table is intercept part of the manual for Linfee Modbus manual.
2117 -
2118 -(% class="wikigeneratedid" %)
2119 -**0x03/0x04 command data register address**:
2120 -
2121 -(% style="width:1142.22px" %)
2122 -|(% style="display:none" %) |=(% colspan="2" rowspan="1" style="width: 165px;" %)Address(% style="display:none" %) |=Description|=Data Format|=(% style="width: 254px;" %)Data Length(Word)|=(% style="width: 282px;" %)Remark
2123 -|(%%)(% style="display:none" %) (%%) HEX|(% style="width:107px" %)DEC|(%%)(% style="display:none" %) (%%) |(% style="width:100px" %) |(%%)(% style="display:none" %) (%%) |(% style="width:318px" %)
2124 -|(% style="width:107px" %)0x00|(% style="width:100px" %)0|Reserved| | |(% style="width:318px" %)
2125 -|(% style="width:107px" %)0x02|(% style="width:100px" %)2|Reserved| | |(% style="width:318px" %)
2126 -|(% style="width:107px" %)0x04|(% style="width:100px" %)4|Reserved| | |(% style="width:318px" %)
2127 -|(% style="width:107px" %)0x06|(% style="width:100px" %)6|Ua|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2128 -|(% style="width:107px" %)0x08|(% style="width:100px" %)8|Ub|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2129 -|(% style="width:107px" %)0x0A|(% style="width:100px" %)10|Uc|float|2|(% style="width:318px" %)Phase Voltage data, Unit V
2130 -|(% style="width:107px" %)0x0C|(% style="width:100px" %)12|Uab|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2131 -|(% style="width:107px" %)0x0E|(% style="width:100px" %)14|Ubc|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2132 -|(% style="width:107px" %)0x10|(% style="width:100px" %)16|Uca|float|2|(% style="width:318px" %)Line Voltage data, Unit V
2133 -|(% style="width:107px" %)0x12|(% style="width:100px" %)18|Ia|float|2|(% style="width:318px" %)Phase Current data, Unit A
2134 -|(% style="width:107px" %)0x14|(% style="width:100px" %)20|Ib|float|2|(% style="width:318px" %)Phase Current data, Unit A
2135 -|(% style="width:107px" %)0x16|(% style="width:100px" %)22|Ic|float|2|(% style="width:318px" %)Phase Current data, Unit A
2136 -
2137 -{{info}}
2138 -**✎Note: **We usually use the Data Type 4 for read the Modbus registers(Function Code 03)
2139 -{{/info}}
2140 -
2141 -For example, here we want to read the Phase Voltage Ua (Modbus offset 0006), the Modbus register main No. requires input decimal number, and check whether the actual address has one address offset, so the tag configured like the following screenshot:
2142 -
2143 -(% style="text-align:center" %)
2144 -[[image:VNETModbusTagSettings.png]]
2145 -
2146 -(% style="text-align:center" %)
2147 -[[image:VNETModbusTagByteSettings.png]]
2148 -
2149 -{{info}}
2150 -**✎Note: **If the read value is incorrect, please check whether need to change the Byte order.
2151 -{{/info}}
2152 -
2153 -Set the Modbus Slave Station No.
2154 -
2155 -(% style="text-align:center" %)
2156 -[[image:ModbusStationSettings.png]]
2157 -
2158 -If the communication is setup successfully, the tag will show green light.
2159 -
2160 -(% style="text-align:center" %)
2161 -[[image:Monitoringtaggreenlight.png]]
2162 -
2163 -== **MODBUS RTU Master** ==
2164 -
2165 2165  Select the protocol "Modbus RTU Master",
2166 2166  
2167 2167  Then set baud rate, port, stop bits, data bits, parity
... ... @@ -2172,8 +2172,8 @@
2172 2172  **address list**
2173 2173  
2174 2174  (% class="table-bordered" %)
2175 -|=(% scope="row" %)**Type**|=**Data Type**|=**Function code and description**
2176 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)
1159 +|**type**|**register**|**Function code and description**
1160 +|(% rowspan="11" %)|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)
2177 2177  |06 (write single register: write a binary value to a holding register)
2178 2178  |10 (write values to multiple addresses )
2179 2179  |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
... ... @@ -2196,61 +2196,6 @@
2196 2196  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
2197 2197  |0F (Write multiple bits)
2198 2198  
2199 -== **MODBUS TCP Slave (All function)** ==
2200 -
2201 -Supported series: MODBUS TCP controller
2202 -
2203 -V-B0X works as MODBUS TCP MASTER connecting with TCP SLAVE
2204 -
2205 -**1)V-BOX Setting**
2206 -
2207 -|**Items**|**Settings**|**Note**
2208 -|Protocol|MODBUS TCP Slave (All function)|
2209 -|Connection|Ethernet|
2210 -|Port No.|502|
2211 -|PLC station No.|1
2212 -
2213 -**2)Address List**
2214 -
2215 -|=**Type**|=**Data Type**|=**Function code & Description**
2216 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
2217 -|06 (write single register: write a binary value to a holding register)
2218 -|10 (write values to multiple addresses )
2219 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
2220 -|06 (write single register: write a binary value to a holding register)
2221 -|10 (write values to multiple addresses )
2222 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
2223 -|06 (write single register: write a binary value to a holding register)
2224 -|10 (write values to multiple addresses )
2225 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
2226 -|10 (write values to multiple addresses )
2227 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
2228 -|05 (Force a single coil to force the on/off state of a logic coil)
2229 -|0F (Write multiple bits, ie write continuously)
2230 -|(% rowspan="3" %)1|02 (Read the input state)
2231 -|05 (Force a single coil to force the on/off state of a logic coil)
2232 -|0F (Write multiple bits)
2233 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
2234 -|05 (Force a single coil to force the on/off state of a logic coil)
2235 -|0F (Write multiple bits)
2236 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
2237 -|0F (Write multiple bits)
2238 -
2239 -**3)Communication Settings**
2240 -
2241 -Configure V-BOX Ethernet IP in Networking Settings
2242 -
2243 -[[image:image-20220902111833-3.png]]
2244 -
2245 -
2246 -Configure PLC Ethernet IP in Communication;
2247 -
2248 -[[image:image-20220902111121-1.png]]
2249 -
2250 -**4)Cable Wiring**
2251 -
2252 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
2253 -
2254 2254  == **communicate with VB inverter** ==
2255 2255  
2256 2256  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
0Il1q9GZgk.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -24.6 KB
Content
1679563870401-671.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -39.3 KB
Content
1682233464031-639.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -15.9 KB
Content
AB.gif
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -7.3 KB
Content
ABRS232.gif
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -7.3 KB
Content
CCW.Shell_E5Cwj4tUL3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -27.1 KB
Content
CrouzetRS232 VBox.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -14.9 KB
Content
DVPEthernetAutoSearch.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -43.6 KB
Content
DVPEthernetPLCtoPC.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -8.9 KB
Content
DVPEthernetSetup.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -19.9 KB
Content
DVPEthernetTransfer.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -59.9 KB
Content
DVPEthernetVNETPortocol.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -21.4 KB
Content
DVPEthernetWPLSoft.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -97.5 KB
Content
DVPEthernetWPLSoft2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -45.2 KB
Content
Delta DVP PROTOCOLSerial232.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -10.7 KB
Content
Ethernet.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -45.5 KB
Content
LinfeeTerminalDiagram.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -8.6 KB
Content
LldwDGntf4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -24.3 KB
Content
MeterModbusAddr.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -562.5 KB
Content
MeterModbusAllView.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -1.6 MB
Content
MeterModbusBaud.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -444.0 KB
Content
MeterModbusPara.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -532.0 KB
Content
ModbusStationSettings.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -35.8 KB
Content
Monitoringtaggreenlight.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -7.5 KB
Content
V-NET_Client setting.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -41.9 KB
Content
V-NET_Client_ADD.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -51.4 KB
Content
V-NET_Client_KOR0AHEA4M.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -14.2 KB
Content
V-NET_Client_TIiAymnjkx.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -12.8 KB
Content
V-NET_Client_communication.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -25.5 KB
Content
V-NET_Client_iKKKhcgxm1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -35.9 KB
Content
V-NET_Client_t2Rg2wpSoY.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -53.7 KB
Content
VNETCommunicationtabmeter.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -31.0 KB
Content
VNETModbusTagByteSettings.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -31.2 KB
Content
VNETModbusTagSettings.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -35.7 KB
Content
WgvjfWbQif.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -36.3 KB
Content
conne ab plc.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -43.1 KB
Content
export.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -115.2 KB
Content
export1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -115.2 KB
Content
image-20220831161041-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -58.1 KB
Content
image-20220831161356-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -27.0 KB
Content
image-20220831163041-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -58.6 KB
Content
image-20220831163406-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -28.4 KB
Content
image-20220831163422-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -53.9 KB
Content
image-20220831163441-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -13.7 KB
Content
image-20220831163548-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -37.1 KB
Content
image-20220831163553-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -37.1 KB
Content
image-20220831163923-7.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -57.3 KB
Content
image-20220831164626-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -56.1 KB
Content
image-20220831164646-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -28.4 KB
Content
image-20220831164700-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -66.6 KB
Content
image-20220831164731-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -12.3 KB
Content
image-20220831165008-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -13.3 KB
Content
image-20220831165017-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -36.2 KB
Content
image-20220831165031-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -28.3 KB
Content
image-20220831165238-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -57.4 KB
Content
image-20220831170147-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -57.1 KB
Content
image-20220831170215-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -14.3 KB
Content
image-20220831170254-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -43.5 KB
Content
image-20220831170306-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -28.5 KB
Content
image-20220831171127-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -60.1 KB
Content
image-20220902104329-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -58.7 KB
Content
image-20220902111121-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -60.9 KB
Content
image-20220902111754-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -57.6 KB
Content
image-20220902111833-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -56.1 KB
Content
image-20221116105850-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -18.9 KB
Content
image-20221116105947-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -18.7 KB
Content
image-20221116110802-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -16.4 KB
Content
image-20221116110832-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -42.2 KB
Content
image-20221116110907-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -17.8 KB
Content
image-20221116110917-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -23.2 KB
Content
image-20221116111427-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -63.4 KB
Content
image-20221116111451-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -225.5 KB
Content
image-20221116111509-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -34.1 KB
Content
image-20221116111651-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -74.3 KB
Content
image-20221116111727-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -106.2 KB
Content
image-20221116114106-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -99.5 KB
Content
image-20221119101759-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -62.1 KB
Content
image-20221119101946-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -68.7 KB
Content
image-20221119171318-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -90.3 KB
Content
image-20221119171343-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -90.3 KB
Content
image-20221119171436-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -43.4 KB
Content
image-20221119171611-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -23.1 KB
Content
image-20221119171832-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -69.6 KB
Content
project create.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -65.5 KB
Content
software.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -25.8 KB
Content
v-net client vers.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -13.1 KB
Content