Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
From version 231.1
edited by Theodore Xu
on 2023/04/23 15:42
on 2023/04/23 15:42
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. AiXia1 +XWiki.Hunter - Content
-
... ... @@ -520,7 +520,7 @@ 520 520 The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. 521 521 522 522 523 -= **Micro850_FreeTag Protocol(new)** = 523 +== **Micro850_FreeTag Protocol(new)** == 524 524 525 525 This example introduces the establishment of Ethernet communication between Wecon V-box and 2080-LC50-48QWB,Micro850. It is introduced through three parts: PLC software configuration, V-box software configuration. 526 526 ... ... @@ -582,7 +582,7 @@ 582 582 (% style="text-align:center" %) 583 583 [[image:V-NET_Client_communication.png]] 584 584 585 -Export variables from PLC, select CSV file, comma delimited. After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png"]]iconaddlabel.585 +Export variables from PLC, select CSV file, comma delimited.(% id="cke_bm_1950S" style="display:none" %) 586 586 587 587 (% style="text-align:center" %) 588 588 [[image:export1.png]] ... ... @@ -590,8 +590,10 @@ 590 590 (% style="text-align:center" %) 591 591 [[image:CCW.Shell_E5Cwj4tUL3.png]] 592 592 593 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png"]]icon add label. 594 + 593 593 (% style="text-align:center" %) 594 -[[image:V-NET_Client_ iKKKhcgxm1.png]]596 +[[image:V-NET_Client_TNBuqy7T5r.png]] 595 595 596 596 **3)Engineering production** 597 597 ... ... @@ -661,6 +661,69 @@ 661 661 **✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details. 662 662 {{/info}} 663 663 666 += Create communication with EMERSON PLC = 667 + 668 +== **RTU Slave Protocol** == 669 + 670 +Supported series: EC10 series 671 + 672 +**1)V-BOX setting** 673 + 674 +|**Items**|**Settings**|**Note** 675 +|Protocol|Emerson 984 RTU Slave MODBUS| 676 +|Connection|RS485| 677 +|Baud rate|19200| 678 +|Data bit|8| 679 +|Parity|EVEN| 680 +|Stop bit|1| 681 +|Device station No.|1|Need to be same as the PLC setting 682 + 683 +(% class="wikigeneratedid" %) 684 +**2)PLC Setting** 685 + 686 +(% class="wikigeneratedid" %) 687 +Remember to use the Control Star to enable the Modbus RTU communication for port 1 in system block before dowload into PLC. 688 + 689 +(% style="text-align:center" %) 690 +[[image:ControlStarSystemBlock.png]] 691 + 692 +(% style="text-align:center" %) 693 +[[image:ControlStarCommunicate.png]] 694 + 695 +(% style="text-align:center" %) 696 +[[image:ControlStarModbus.png]] 697 + 698 +(% class="wikigeneratedid" %) 699 +**3)Address List** 700 + 701 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 702 +|(% colspan="1" rowspan="12" %)Bit|Y|YOOO|0~~377| 703 +|X|XOOO|0~~377| 704 +|M0|M0DDDD|0~~2047| 705 +|M1|M1DDDDD|2048~~10239| 706 +|SM0|SM0DDD|0~~255| 707 +|SM1|SM1DDD|256~~511| 708 +|S0|S0DDDD|0~~1023| 709 +|S1|S1DDDD|1024~~4095| 710 +|T0|T0DDD|0~~255| 711 +|T1|T1DDD|256~~511| 712 +|C0|C0DDD|0~~255| 713 +|C1|C1DDD|256~~306| 714 +|(% colspan="1" rowspan="7" %)Word|D|DDDDD|0~~7999| 715 +|Z|ZDD|0~~15| 716 +|TW0|TW0DDD|0~~255| 717 +|TW1|TW1DDD|256~~511| 718 +|SD0|SD0DDD|0~~255| 719 +|SD1|SD1DDD|256~~511| 720 +|CW|CWDDD|0~~306| 721 +|(% colspan="1" rowspan="2" %)Double Word|CW0|CW0DDD|200~~255| 722 +|CW1|CW1DDDDD|256~~99999| 723 + 724 +**4) Cable Wiring** 725 + 726 +(% style="text-align:center" %) 727 +[[image:Emerson.png]] 728 + 664 664 = Create communication with **Siemens PLC** = 665 665 666 666 == **S7-200 Smart Ethernet Protocol** ==
- ControlStarCommunicate.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.0 KB - Content
- ControlStarModbus.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content
- ControlStarSystemBlock.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.3 KB - Content
- Emerson.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- V-NET_Client_TNBuqy7T5r.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.7 KB - Content